HINKLEY 58064 Flash Mount Instruction Manual

June 3, 2024
HINKLEY

HINKLEY logo 58064 Flash Mount
Instruction ManualHINKLEY 58064 Flash Mount

58064 Flash Mount

HINKLEY
DRAWING 1 – MOUNTINGHINKLEY 58064
Flash Mount fig 2 Drawin g 3– Glass AssemblyHINKLEY 58064 Flash Mount fig 3

Mounting Instructions

Item No: 5E1064-58063-58062
start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.
  4. Prepare gem strap (A) for mounting, by threading the two screws (B) provided into the back of the gull wing bracket on gem strap (A) – see Drawing 1. • Be sure that holes into which the screws are threaded match the spacing of the mounting holes (D) in the back plate (E) – see Drawing 2.
  5. Mount gem strap (A) to junction box (J) using two screws (C) not provided.

Safety Warning: read wiring and grounding instructions (1.5. 18) and any additional directions, Turn power supply off during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.

  1. Mount fixture by slipping the holes (D) in the backplate (E) over the screws (B) in the mounting strap (A) – see Drawing 2.
  2. Hold fixture against wall and thread barrel knobs (F) onto end of screw (B) showing through the backplate (E). Tighten barrel knobs against backplate to secure fixture to wall.

To install glass (Y) let glass rest on glass holder (Z)

I.S.18 wiring grounding instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 1 – Flush Mount
HINKLEY 58064 Flash Mount fig 4

Wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures
Drawing 2 – Chain Hung
HINKLEY 58064 Flash Mount fig
5

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – – – see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    ˜If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Drawing 3 – Post-Mount
HINKLEY 58064 Flash Mount fig 6

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

HINKLEY logoHINKLEY 33000 Pin Oak Parkway,
Avon Lake, OH 44012
800.446.5539 / 440.653.5500
hinkley.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals