T S EC-EASYWIRE4CC Checkpoint Easywire Connector Cable Instruction Manual

June 3, 2024
T S

T S EC-EASYWIRE4CC Checkpoint Easywire Connector Cable Instruction Manual
VISION TM-CC Close-Coupled Projector Ceiling Mount

Installation Instructions

  1. The EC-EASYWIRE kit along with multiple numbers of the EC-EASYWIRE4CC may be used to easily connect and gang up to 8 of any of the ChekPoint electronic sensor faucet.
    Installation Instructions

  2. The EC-EASYWIRE kit consists of a 100-240 VAC transformer with a 76” long power cord which plugs into a standard wall outlet (Figure 1).
    Installation Instructions

  3. The EC-EASYWIRE4CC kit consists of a 48” long power cord with 2 male connectors and one female connector used to make the connections as noted in the diagram in Figure 2. In utilizing the EASYWIRE method, multiple ECEASYWIRE4CC (ordered separately from the EC-EASYWIRE) must be used to connect and gang the ChekPoint electronic sensor faucets. The multiple number of EC-EASYWIRE4CC needed is one less than the number of ChekPoint faucets.
    Installation Instructions
    For example, if you are ganging eight (8) ChekPoint faucets together, you will need to order seven (7) of the EC-EASYWIRE4CC and one (1) EC-EASYWIRE. All ChekPoint models are able to be installed using the EASYWIRE method.

  4. The EC-EASYWIRE5EXT kit is a 60” extension which can be used in between the multiple EC-EASYWIRE4CC and also the controllers (Figure 3).
    Installation Instructions

SENSOR RANGE SETUP

Models with blue below deck control modules

The sensor range is preset at the factory during assembly but can be further adjusted by using the steps below.

  1. The sensing distance is adjustable from ¾” (2cm) to 6 11/16” (17cm). If there is a disruption in power, the sensor range is saved and will revert to the last setting when power is restored.
  2. The faucet sensor range is set by simply using the on/off button on the front of the control module. Do not attempt to open the control module box.
  3. Push and hold the on/off button; water will fl ow. After holding the button 5 to 7 seconds, the water fl ow will stop and the red LED in the sensor lens will turn on solid.
  4.  Release the on/off button. The red LED will turn off signaling that the sensor is ready for set-up for the next 15 seconds.
  5. Hold your hand still in front of the sensor at the desired sensor distance. The red LED will fl ash roughly 5 times then remain on for 2 seconds indicating the new range has been set.
  6. If step 5 is not done within 15 seconds, the red LED will blink quickly then stop indicating the sensor range has NOT been changed. Start over at step 3 to change the sensor range

EC-3122:

The EC-3122 uses a digital infrared, distance adjustable sensor which has a default range set at the factory. Should this range need to be changed, follow the steps below. The sensing distance is adjustable from 3/4” (2cm) to 6 11/16” (17cm).

  1. Shut off the water at the hot and cold supply stops.
  2. Place the magnet provided to the upper right side of the sensor lens and move it closer to the lens.
  3. Hold the magnet in place for 3 to 5 seconds. The red sensor LED will come on for set-up mode.
  4. Remove the magnet and the sensor LED will go out.
  5. Place a hand to the desired sensor range, hold in place and the LED will light up. (The recommended sensor range is 3/8” [1 cm] in front of the spout).
  6. Place the magnet to the right side of the sensor lens and move it closer to the lens until it starts blinking 5 times.
  7. Remove your hand and magnet from the sensor area.
  8. Turn on the water at the hot and cold supply stops.
  9. Move a hand into the range set in step 5 which will activate the sensor (the LED will blink once) and water will begin to fl ow.
  10. If after removing your hand from the sensor range, the water continues to fl ow for longer than 2 seconds, then the sensor range will need to be reset to a shorter distance.
    Sensor Range Setup

EC-3130 & EC-3132:

The EC-3130 and EC-3132 faucets have an adjustable sensor with a default range set at the factory. Should this range need to be changed, follow the steps below and refer to Figure 4. The sensing distance is adjustable from 3/4” (2cm) to 6 11/16” (17cm).

  1. Place the magnet provided on the upper right corner of the sensor for 5 seconds. When the magnet is in place the solenoid will open.
  2. After 5 seconds when the solenoid closes and the LED turns on, remove the magnet.
  3. The LED will turn off indicating the sensor is now in set-up mode. Note: the sensor will remain in set up mode for approximately 15 seconds. Then the LED will fl ash 3 times before the sensor range returns to its previous setting.
  4. While in set-up mode, hold your hand at the desired distance from the sensor for 3 seconds. The LED will blink.
  5. After the 3 seconds, the blinking LED will stay on for a few seconds then turn off .
  6. When the LED turns off , the new range setting is saved
  7. Even if the faucet loses power such as when the battery is replaced, the setting saved above will be kept
    Sensor Range Setup

Limited Three Year Warranty

T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this three-year warranty period, if the product is found to be defective, T&S shall, at its options, repair and/or replace it. To obtain warranty service, products must be returned to.

T&S Brass and Bronze Works, Inc.
Attn: Warranty Repair Department
2 Saddleback Cove
Travelers Rest, SC 29690

Shipping, freight, insurance, and other transportation charges of the product to T&S and the return of repaired or replaced product to the purchaser are the responsibility of the purchaser. Repair and/or replacement shall be made within a reasonable time after receipt by T&S of the returned product. This warranty does not cover Items which have received secondary fi nishing or have been altered or modifi ed after purchase, or for defects caused by physical abuse to or misuse of the product, or shipment of the products.

Any express warranty not provided herein, and any remedy for Breach of Contract which might arise, is hereby excluded and disclaimed. Any implied warranties of merchantability or fi tness for a particular purpose are limited to three years in duration. Under no circumstances shall T&S be liable for loss of use or any special consequential costs, expenses or damages.

Some states do not allow limitations on how long and implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Specifi c rights under this warranty and other rights vary from state to state.

Attention California Residents:
“WARNING: This product contains chemicals known to the State of California to cause cancer, and birth defects or other reproductive harm.”

Support

&S Brass and Bronze Works, Inc. · 2 Saddleback Cove · P.O. Box 1088 · Travelers Rest, SC 29690
www.tsbrass.com · E-mail: tsbrass@tsbrass.com · Phone 800-476-4103 · Fax 800-868-0084
West Coast Sales and Distribution · 4596 Ish Drive · Unit 220
Simi Valley, CA 93063 · Phone 800-423-0150
098-017998-45 Rev. 2
Drawn TEH 10-21-15
Checked DMH 11-03-15
Approved JHB 11-25-15