MeacoFan 1056 Air Circulator Instruction Manual

June 5, 2024
MEACO

MeacoFan 1056 Air Circulator

  1. MeacoFan-1056 Air-Circulator

Please read this instruction manual before using the air circulator and keep safe for future reference.

SAFETY INFORMATION

This air circulator must not be used in rooms under the following conditions:

  • Potentially explosive atmosphere
  • Aggressive atmospheres
  • Featuring a high concentration of solvents
  • An extremely high ratio of dust

Magnets: The air circulator and the remote control both contain magnets. Please note the following: Pacemakers and defibrillators may be affected by magnets. If this affects you then please do not put the remote control in a pocket and warn anyone who is likely to use the air circulator or the remote that it has a magnet. Credit cards and data cards can also be affected by magnets and should not be placed near to the air circulator or the fan.

Keep Children Away: Do not allow children to play with or around this unit, which could result in injury. Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Keep Unit Grounded: Always operate the unit with a grounding plug and a grounded electrical outlet. A grounding plug is an essential safety feature that helps reduce the risk of shock or fire.

Protect Power Cord from Damage: Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same type and amperage rating.
Extension Cords: Extension cords must be grounded and able to deliver the appropriate voltages to the unit.
Handle with Care: Do not drop, throw or crash the air circulator. Rough treatment can damage the components or wiring and create a hazardous condition.
Run on Stable Surface: Always operate the unit on a stable, level surface, for example the floor or a strong counter, so that the air circulator cannot fall and cause injury.
Keep Out of Water: Never operate the unit in pooled or standing water, as this may create a risk of injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become wet, thoroughly dry them before using the unit. If in doubt do not use the air circulator and consult a qualified electrician or a Meaco approved engineer.
Keep Air Intakes Clear: Do not clog or block the air intakes by placing the air circulator too close to curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result in a fire or electrical hazard.
Keep Electrical Components Dry: Never allow water inside the air circulator’s electrical components. If these areas become wet for any reason, thoroughly dry them before using the air circulator. If in doubt, do not use the air circulator and consult a qualified electrician or a Meaco approved engineer.
The operator must make the operating instruction available for the user and make sure that the user does understand the manual.

GENERAL ADVICE

  • Before putting your air circulator into operation for the first time, the instruction manual should be studied carefully.
  • After receiving the air circulator, you should check the unit for any transport damage. In case of damage, you should inform the sender immediately.
  • Keep the packaging for the air circulator in a safe place in order to be able to despatch the unit safely if it requires a service. In order to save space, you can simply cut through the adhesive tape using a knife and fold the cardboard box.

PRODUCT IDENTIFICATIONMeacoFan-1056 Air-Circulator-1

  1. Magnetic remote-control holder
  2. Front guard
  3. Spinner
  4. Fan blades
  5. Handle
  6. Rear guard
  7. Fan motor
  8. Control panel
  9. Base
  10. Mains lead tidy
  11. Remote control

The handle is made from artificial materials and does not contain any animal products. ** The remote control is supplied with a CR2025 DC3v battery. Please remove the tab from the battery before use.

CONTROL PANEL

MeacoFan-1056 Air-Circulator-2

Please note all the buttons are touch sensitive and bleep when pressed.

POWER BUTTON
When plugged in the fan will bleep once and display the room temperature on the display, this is standby mode. To turn the fan on press the power button. The fan will bleep and start to operate. To turn the fan off press the power button again, you will hear a longer bleep and the fan will slow down and stop.
SPEED BUTTON
Press the speed button to adjust the air flow fan speed. There are 12 fan speeds available. As long as the fan remains plugged in, the fan will remember the last fan speed used. The speed can be adjusted on the control panel or via the remote control.
VERTICAL AND HORIZONTAL OSCILLATION BUTTONS (OSC)
Press the oscillation buttons to start and stop the sideways oscillation left and right or up and down. Press the button once to turn the oscillation on and press the button again to stop the motion, in doing so you can fix the direction of the fan.
TIMER BUTTON
When the fan is in standby mode use the timer button to set an interval, in one-hour segments, between 1 and 12 hours after which the fan will turn ON. Once you have reached the desired number of hours on the display the number will flash four times and then set.
When the fan is turned on and running, use the timer button to set an interval, in one-hour segments, between 1 and 12 hours after which the fan will turn OFF. Once you have reached the desired number of hours on the display the number will flash four times and then set.
To turn the timer off, press the timer button until 00 is displayed.
ECO BUTTON
Press the ECO button to turn ECO mode ON/OFF. In ECO mode the fan speed will automatically change as per the table on the following page. The room temperature will appear on the display.

ECO Mode

Room temperature Fan speed
<23°C 2
23 to 25°C 4
25 to 27°C 6
27 to 29°C 8
29 to 31°C 9
31 to 33°C 10
>33°C 12

REMOTE CONTROL

MeacoFan-1056 Air-Circulator-3

The following functions are only available via the remote control. All other buttons on the remote-control work in the same way as the control panel (see page 4). The remote control has a range of approximately three metres. Before using the remote control, remove the plastic tab.

LIGHT BUTTON
Press the light button to turn the lights on the display ON/OFF.

INCREASE FAN SPEED
Press the increase fan speed button to increase the air flow fan speed between 1 and 12.

DECREASE FAN SPEED
Press the decrease fan speed button to decrease the air flow fan speed between 1 and 12.

PRE-ON TIMER
Press the pre-on timer button to set an interval, in one-hour segments, between 1 and 12 hours after which the fan will turn ON. This can only be used when the fan is in standby mode.

PRE-OFF TIMER
Press the pre-off timer button to set an interval, in one-hour segments, between 1 and 12 hours after which the fan will turn OFF. This can only be used when the fan is on and running.

ELECTRICAL CONNECTIONS AND OPERATING CONDITIONS

This air circulator was designed to operate in a 220-240V / 50Hz electrical installation. Make sure that the electric sockets are connected to earth and that all safety precautions are taken. This air circulator can be operated within an ambient temperature range from +5°C to +40°C and with a non- condensing relative humidity.

SPECIFICATIONS

Operating conditions

|

+5°C to +40°C

---|---

Humidity operating range

|

Non-condensing

Fan motor type

|

DC

Maximum air flow

|

1056 cubic metres per hour

*Maximum air velocity (c)

|

6m/sec

*Rated voltage and frequency

|

220 – 240V / 50Hz

Power consumption

|

9.5 to 23.5 watts

*Standby power consumption (PSB)

|

0.671 watts

Oscillation swing angles

|

60° vertically and 80° horizontally

*Fan sound power level (LWA)

|

20 to 60dB(A)

*Service value (SV)

|

0.62 (m³/min)/watts

*Fan power input (P)

|

26 watts

*Maximum fan flow rate (F)

|

17.6m³/min

Dimensions (HWD)

|

403 x 285 x 305mm

Nett / Gross weight

|

3.2 / 4.7 Kgs

CLEANING AND MAINTENANCE

Always turn the fan off and unplug it from the socket before cleaning.
Use a soft dry cloth to clean the external and internal parts of the fan. Do not allow the fan to get wet. In order to access the fan blades, follow the steps below:

  1. Using a screwdriver, unscrew the two small screws at the top back of the fan. They are located directly below each end of the handle.
  2.  Squeeze the two tabs to the left and right of the screws and pull away. At the front of the fan blades there is a locking cap – unscrew the cap in a clockwise motion to remove the fan blades.MeacoFan-1056 Air-Circulator-5
  3. Clean the fan blades and the internal part of the fan using a soft dry cloth. Reverse the procedure to put the fan back together. Make sure the locking cap is tightened securely.

REPLACING THE REMOTE-CONTROL BATTERY

If the remote control fails to work whilst close to the fan, the battery will need replacing. The battery is a CR2025 and can be replaced following the steps in the diagram below.MeacoFan-1056 Air-
Circulator-7

STORAGE

When storing the fan use the cable compartment at the back of the fan to store the mains cable. The cable compartment cover may be stiff to remove at first – use the small lever at the top to pull it away from the fan.
We recommend storing the fan its plastic bag or original box to protect the fan from dust.
Remember the fan can also be used in winter to help distribute warm air more effectively within a room.

TROUBLESHOOTING

TROUBLE CAUSE SOLUTION

The display shows ‘00’ or ‘99’

|

There is a problem with the circuit

|

Please contact Solenco

The fan does not oscillate

|

The MPCB needs resetting

|

Unplug the fan from the mains for 40 minutes

Increased noise level

|

The fan blades are dirty

|

Clean the fan blades (see page 8)

The fan blades or fan motor is loose

|

Tighten the locking cap (see page 8)

There is a fault with the fan motor

|

Please contact Solenco

The motor can be heard on the lower fan speeds

|

As the fan is so quiet it is expected to hear the motor on the lower fan speeds. As the fan speed increases, the noise of the motor will reduce

|

This is not a fault and is normal

The fan does not start up

|

The fan is in standby mode

|

Press the power button again

The fan is making a clicking noise

|

The fan needs lubricating

|

Run the fan on the highest fan speed for 4 hours

The remote does not work

|

The battery needs replacing

|

Replace the battery (see page 9)

The remote is being used more than 3m away from the fan

|

Use the remote closer to the fan and make sure it is pointing directly at the fan base

There is a ‘h’ on the display

|

‘h’ stands for hours and will be seen on the display when the timer is being set

|

Press the timer button until ‘00’ is shown on the display – this will remove the timer

WARRANTY AND CUSTOMER SERVICE

There is a two-year manufacturer’s warranty on your air circulator from the date of purchase. Please register your purchase at https://www.meaco.com/pages /register-your-warranty. Registering also allows us to keep you update with any important developments concerning your product.
Within the two-year manufacturer’s warranty, all manufacturing defects will be repaired free of charge.
The following applies:

  1. Any repairs or replacement of components during the warranty period will not result in an extension of the warranty period.
  2. The warranty will expire if any alterations have been made, not genuine components have been fitted or if the air circulator has been repaired by a third party.
  3. Components subject to normal wear and tear are not covered by the warranty.
  4. The warranty is only valid on presentation of the original, unaltered, and date-stamped purchased receipt.
  5. The warranty does not cover damage caused by actions that deviate from those as described in the user’s manual or by neglect.
  6. The warranty does not cover faults caused by dirt or by third-party products.
  7. The warranty does not cover accidental damage.
  8. All claims for compensation, including consequential damage, will not be entertained.
  9. Using a third-party switching device that turns the air circulator on or off via the mains will invalidate the warranty.

For the full list of the warranty terms and conditions please visit: garantivillkor, https://www.meaco.com/pages/warranty-terms.
To prevent unnecessary expenses, we recommend that you always carefully read the user’s manual first. If this does not provide a solution, please call Solenco and they will be happy to help.

This air circulator has been imported into SA by: Solenco South Africa
Unit 4 Fairview Industrial Park Leadwood Crescent
Fairview, Gqeberha, 6070
Telephone: 0861 388 878
Email: [email protected]
Website: https://www.solencosa.co.za/
Manufactures details: [email protected].

If your air circulator develops a fault at any time, please contact us and we will always try and help you as best we can. Please keep hold of the original box and packaging your unit arrived in just in case we need to collect the air circulator from you for a repair/service in the future.

This marking indicates that this product should not be disposed with other household wastes throughout South Africa. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.