FRYCLONE 259DISP50 Fryer Oil Disposal Units User Manual
- June 3, 2024
- FRYCLONE
Table of Contents
FRYCLONE 259DISP50 Fryer Oil Disposal Units
STANDARD FEATURES & BENEFITS
-
Locking Back Casters
Hold the unit steady during use, while front casters swivel for easy mobility. -
Strainer
Catches debris from fryer, separating it from the oil and preventing pump clogs. -
High-Temperature Flexible Hose with Swept Faucet
Eliminates heavy lifting while transferring oil from the disposal unit into collection containers. -
Sturdy Manual Hand Pump
Reinforced construction for reliable use.
SAFETY WARNINGS
- WARNING: Do not pour hot oil into the oil shuttle. Let oil cool for 45+ minutes after use.
- WARNING: Always use a splash-proof apron and gloves to avoid burns.
- WARNING: Make sure oil transporter is lying flat before opening the drain.
- WARNING: Make sure lid is fully closed and secured before tilting & transporting.
- WARNING: Do not fill oil past max fill line indicated inside the body of the shuttle.
SPECIFICATIONS
ITEM # | 259DISP50 | 259DISP100 |
---|---|---|
WIDTH | 11½” | 17″ |
DEPTH | 28¾” | 32½” |
HEIGHT | 15¾” | 17″ |
CAPACITY | 50 LB. | 100 lb. |
POWER TYPE | Manual | Manual |
IDEAL USE | Servicing 1-2 Fryers | Servicing 2-4 Fryers |
TYPE | Disposal Caddy | Disposal Caddy |
GENERAL OPERATING INSTRUCTIONS
-
Make sure the disposer is fully dry before use.
-
Make sure the fryer is off and the oil has had sufficient time to cool
-
Open the lid, and lock back casters so the shuttle doesn’t move.
-
Verify that the crumb screen and rubber gasket on the inside cover are in place and position the unit so that the opening is directly under the frypot drainpipe.
-
Slowly open the drain valve. Regulate flow with the drain valve to prevent splashing.
NOTE: DO NOT overflow the disposal unit. -
Once the fryer is completely drained, carefully move the unit away from the fryer and allow the cover to be closed.
-
Latch the cover in the closed position and unlock the casters.
-
Using the handle, carefully roll the unit to the disposal area.
-
At the disposal site, turn the pump handle clockwise. (The pump should start discharging oil after a few turns.)
-
Continue turning the handle until the reservoir is empty.
-
Clean Fryclone disposer with hot water and ammonia weekly. Let air dry.
-
Make sure the unit is fully dry before re-using.
WARNING
Do not use this unit to dispose of water or boil-out solution. The
introduction of water or solvents into the unit will permanently damage the
pump.