Overview
This weekly timer with lockdown and fire alarm control is housed in a
convenient 1RU rack mount chassis. A total of 50 “event” switching times are
available through the timing functions. Each event can be set to turn on any
single day of the week or on multiple days, from 1 sec up to 24 hours. When a
timing event is activated, an MP3 audio file will be played and output through
the dual RCA line level output.
There are fourteen MP3 playback options for the timing events, which include
the Bell, Prebell, Music and folders 5-15. A Micro SD card which is supplied,
houses all the MP3 files to be played as well as storing all the timing events
(Note: The audio files must be in MP3 format). The timing events can be
programmed via supplied PC software.
The timing events can also be programmed to only trigger the Bell 24V out (and
in turn the common 24V Out), with no audio output. This is activated by
setting the output to the “relay” option in the programming setup.
The lockdown/fire controller is designed around industry standard building
emergency requirements. When connected to a paging system amplifier, building
occupants can be alerted and/or evacuated in the event of an emergency e.g.
fire, gas leak, bomb scare, earthquake. Lockdown & fire switches on the front
of the unit are fitted with safety covers to prevent accidental operation.
Warnings, bell and cancel function are triggered by the front switches, or by
the rear terminal contacts for remote activation. Switched 24V DC out
connections are provided for bell, lockdown, fire or a common out. These
contacts are for connection of override relays in remote volume controls,
warning strobes, bells etc. The lockdown and fire tones are stored on a Micro
SD card in MP3 format (emergency tones which conform to AS1670.4 are supplied)
to allow the user to provide any tones they require. The Fire mode has a voice
over option for the playback of a fire message after every playback of the
fire tone. The voice over message is also stored on the SD card and is DIP
switch enabled. The lockdown mode has a voice over option for the playback of
a lockdown message after every playback of the lockdown tone. The voice over
message is also stored on the SD card and is DIP switch enabled.
Key Features
√ Australian made
√ 10 year manufacturer warranty with local product support
√ MP3 audio format for Bell, Prebell and Music timing outputs
√ MP3 audio format Emergency Tones conform to AS 1670.4 (supplied)
√ Random play of MP3 files for Prebell and Music triggers
√ Easy PC based timing event setup
√ Local push button operation of Lockdown, Fire and Bell
√ Remote triggering of Lockdown, Fire and Bell
√ MP3 audio format Voice over message (Available in the Lockdown and the Fire
cycle)
√ Switched 24VDC output for Bell, Lockdown or Fire mode
√ Pluggable screw terminal connections
√ Auxiliary level output
√ Battery backup of current time
√ 24V DC operation
√ Standard 1U 19” rack mount case
√ Suitable for any amplifier with an auxiliary input
About Redback ® Public Address
Products Redback ® products are proudly designed, engineered and manufactured in Australia. Each unit is covered by a comprehensive 10 year parts and labour warranty. Redback ® offers rock solid reliability from over 40 years experience in the commercial sound industry. Redback ® offer locally available servicing and parts, plus the ability to offer feedback direct to the manufacturer.
Rear Panel
1 24V DC Input (2.1mm jack) | 9 Lockdown Contact | 17 Timer Backup Battery |
---|---|---|
2 24V DC Input (Back Up) | 10 Bell Contact | 18 Lockdown/Fire Volume |
3 DIP Switches | 11 Common 24V Out | 19 Bell Volume |
4 RJ45 Interface (To remote wallplate) | 12 Fire 24V Out | 20 Music Volume |
5 RJ45 Interface (To paging console) | 13 Lockdown 24V Out | 21 Voice – over |
Volume
6 Paging Mic Volume| 14 Bell 24V Out| 22 PreBell Volume
7 Cancel Contact| 15 RJ45 Interface (Not used)| 23 Audio Output (Stereo RCA)
8 Fire Contact| 16 Backup Battery Switch|
Specifications
Electrical
Output Level: | 0dBm |
---|---|
Distortion: | 0.01% |
Freq. Response: | 140Hz – 20kHz |
Signal to Noise Ratio: | -70dB typically |
Muting: | Via Microphone Switch Contact |
Power supply: | 24V DC |
MP3 File Format: | 128kbps, 44.1kHz, 32bit, VBR or CBR, Stereo (even better as |
mono).
Controls
Lockdown/Fire: | Rear Volume |
---|---|
Voice over: | Rear Volume |
Bell: | Rear Volume |
Prebell: | Rear Volume |
Music: | Rear Volume |
Power: | On/Off Switch |
Lockdown Switch: | lluminated Push Button |
Fire Switch: | Illuminated Push Button |
Bell Switch: | Illuminated Push Button |
Cancel Switch: | Push Button |
Indicators: | Power on, MP3 error, Prebell |
Connectors
Audio Output: | RCA Stereo Socket |
---|---|
Common 24V DC Out: | Screw Terminals |
Lockdown 24V DC Out : | Screw Terminals |
Fire 24V DC Out: | Screw Terminals |
Bell 24V DC Out: | Screw Terminals |
Mechanical
Dimensions:| ≈482W x 175D x 44H
Weight:| ≈2.1 kg
Colour:| Black
Made in Australia by Altronic Distributors Pty. Ltd.
Ph: (08) 9428 2199 Internet: