CONDUCTIX wampfler Enable Plug for Interface M12 Instruction Manual
- June 3, 2024
- Conductix Wampfler
Table of Contents
Enable Plug for Interface M12
Instruction Manual
Order number
91000-400-3089971
Enable Plug for Interface M12
IMPORTANT:
This document describes the component specified on the cover only. The
manual does not include details about the interaction of the component with
other IPT® components within a system.
System related details are found in the system manuals. Please refer to those
documents before starting any work on the system or on components within the
system or before operating the system.
We reserve the right to carry out technical modifications of illustrations and
statements in this instruction manual.
References to other IPT documents specifying the document number, do not
include the revision index. Refer to the project handbook for a list of
relevant documents.
Unless otherwise specified, all dimensions refer to the metric system, i.e.
lengths are always in mm unless specified in other dimensions.
Document subject to change without prior notice.
© Conductix-Wampfler GmbH 2009
Symbols and hints
Warning of voltage
This symbol can be found in several places in the operating instructions where
special care has to be taken due to voltage which is a potential danger to the
life of people. Please observe these instructions and be careful in those
cases. Please carry out all health and safety regulations to ensure safety to
other users as well. Always disconnect the system from the main supply prior
to carrying out any work on the energy supply system.
Attention – some hints
This sign draws the attention to parts of the operating instructions where the
regulations and advice and correct operational sequence must be observed to
avoid any damage or destruction to the energy supply system and its
components.
Temperature
This sign draws the attention to parts of the operating instructions where
special care must be taken on account of heating of surfaces or on account of
inductive heating of ferromagnetic material and where other special measures
have to be taken. Please pass on the corresponding advice to other users too.
Advisory information for the user
When opened, components of an IPT® system can contain lethal voltage depending
on the state of operation.
Non-permissible removal of required components, improper operation, faulty
installation or operation involves risk of severe injuries to persons and
damage to components.
All electric installation and commissioning works as well as repair works and
disassembly have to be carried out by qualified staff (IEC 364 respectively
CENELEC HD 384 or DIN VDE 0100 and IEC 664 or DIN VDE 0110 and national safety
rules).
Qualified staff according to the safety regulations, are persons that are
familiar with the installation, assembly, commissioning and operation of the
energy supply system and that have the appropriate qualifications.
Conductix-Wampfler GmbH cannot be held responsible for damage or breakdown
that may have been caused by not observing this manual.
Operation, Maintenance and repair
Enable plugs for Interface M12 are not designed for independent operation.
They have to be operated in conjunction with corresponding IPT® -Rail
components. Therefore no specific details about the operation are given here.
There are no specific maintenance or repair work required.
Disassembly/re-use
If it is necessary to exchange the Enable Plugs for Interface M12 due to
damage or to install it in another place, verify that no damage will occur
during disassembly.
All electric work have to be carried out by qualified staff (IEC 364
respectively. CENELEC HD 384 or DIN VDE 0100 and IEC 664 or DIN VDE 0110 and
national safety rules).
Qualified staff according to the safety regulations are persons that are
familiar with the installation, assembly, commissioning and operation of the
energy supply system and that have the appropriate qualifications.
4.1 Safety advice for disassembly and disposal
- Disconnect IPT® system from the mains voltage
- Make sure the system cannot be powered up again accidentally
- After disconnecting the track supply from the supply voltage wait at least 5 minutes for internal discharging
- Dismount
- Dispose of components in a specific way → Recycling.
4.2 Recycling
The unit contains components that have to be disposed of in a specific way. If
it is not used any longer, it will have to be recycled properly.
Intended purpose
The intended purpose of the enable plug is for use in conjunction with other
IPT components.
The intended purpose of the enable plug is to bridge pin 1 and 4, i.e. for use
in conjunction with 3050777 (but not exclusively).
Please note that the enable plug also shorts all the other pins together
except for pin 2 and therefore may not be used with an extension cable if the
signal on the other pins (relay) are needed.
Left: Intended use: external wiring of Interface M12
Right: If no external wiring of Interface M12 is possible enable contacts
need to be bridged
e.g. Pickup 91212-332-3050777
Dimensions
Sequence of replacement
Conductix-Wampfler GmbH
Rheinstraße 27 + 33
79576 Weil am Rhein – Märkt
Germany
Phone: +49 (0) 7621 662-0
Fax: +49 (0) 7621 662-144
info.de@conductix.com
www.conductix.com
Importer for the United Kingdom:
Conductix-Wampfler Ltd.
1, Michigan Avenue
Salford
M50 2GY
United Kingdom
Phone: +44 161 8480161
Fax: +44 161 8737017
info.uk@conductix.com
www.conductix.com
BAL9100-0121c-EN
www.conductix.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>