IGT G900-001 Gas Weight User Manual
- June 3, 2024
- IGT
Table of Contents
IGT G900-001 Gas Weight
The Bluetooth version GAS VIE is composed of the Display and the Scale. There is wire connection to send the data between the display and the scale. For checking the gas level in real time, it could be realized by Mobile Application. The users need to switch on the Bluetooth in mobile phone to connect the Bluetooth inserted in gas view. The display will show the gas level in cylinder and the status of Bluetooth connection. The scale could be collecting the data of gas level and send to the display.
Appearance
Button and Interface
- Wakeup Button
- After pressing the wakeup button, the scale will collect the data of gas level and show the value of gas level by % or by kg
- Setup Button
- Free switch by Percentage(%) or by Kg to show the gas level
- Display Area
- Showing the status of data of gas level and Bluetooth connection
- Battery Jar
- Equipped with 3 pcs double A battery
Technical Parameters
Serial No.|
Item
|
Description
---|---|---
1
| Working Temperature|
﹣20~+40℃
2
| Storage Temperature|
﹣40~+85℃
3
| Working Humidity| 5%~95% (+25℃) ,There is no condensation inside the product
4
| Altitude|
≤3000m
5
| Weighing Scale| ⅢDegree
6
| Weighing Range| 1-40KG
7
| Maximum power of the whole device|
0.25W
8
| Power Supply| 3 pcs double A battery
9
| Voltage| 4.5V
10
| Service Life| MTBF (mean time between failures) ≥ 30000 h at 25 ℃
11
| Display| Response time < 1s
---|---|---
14
| Gross Weight of the whole device| <2kg
Instruction Manual
- Place the scale on a flat surface with a slope of less than 3 ° to ensure that the four legs of the scale touch the ground at the same time.
- Lift the LPG cylinder vertically and put it into the base slowly.
- Use a retractable hanging rope, one end is connected to the display terminal, and the other end is covered into the valve of the cylinder, as shown in Figure 1. In order to prevent weighing error, please do not force to smash the LPG cylinder into the scale.
Applicable Method
- Put three double A batteries into the battery jar.
- After installing the battery, press the wakeup button to awaken the display terminal.
- When there is no cylinder on the scale, the display will be showing the digit 0. When the cylinder has been placed on the scale, the display terminal will be showing the gas level in real-time.
- Press the setup button once to switch the display mode to the current gas level (Gross weight – Net weight)
- Press the setup button again to switch the display mode to percentage showing. When there is no cylinder in the scale or the cylinder is overweight, the percentage is 0%.
- The gross weight and net weight of the cylinder can be set in the mobile application. When use it at the first time, please configure the parameters in mobile application according to the actual situation.
- The display will turn off 30 seconds after the screen wakes up. Press the wakeup button again to awaken the display
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any inte rference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interferenceto radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
Read User Manual Online (PDF format)