Leonton EG5-1600-M12XB-67, EG5-1600-M12XB-T67 Device User Manual
- June 3, 2024
- Leonton
Table of Contents
Leonton EG5-1600-M12XB-67, EG5-1600-M12XB-T67 Device
© Copyright 2021 Leonton Technologies Co., Ltd. All Rights Reserved
This document contains information, which is protected by copyright.
Reproduction, adaptation or translation without prior permission is
prohibited, except as allowed under the copyright laws.
Disclaimer
Leonton Technologies, Co. Ltd. provides this manual without warranty of any
kind, expressed or implied, including but not limited to the implied
warranties of merchantability and fitness for a particular purpose. Leonton
Technologies, Co. Ltd. may make improvements and/or changes to the product
and/or specifications of the product described in this manual, without prior
notice. Leonton Technologies, Co. Ltd. will not be liable for any technical
inaccuracies or typographical errors found in this guide. Changes are
periodically made to the information contained herein and will be incorporated
into later versions of the manual. The information contained is subject to
change without prior notice.
FCC Notice
This equipment has been tested and found to comply with the limits for a
Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy. It may cause harmful interference to radio
communications if the equipment is not installed and used in accordance with
the instructions. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
OVERVIEW
This series is rated IP67 and installation by Wall Mounting. Each unit of this
industrial gigabit managed Ethernet switch provided 16*10/100/1000Base-Tx,
suitable for Ethernet conversion applications.
In order to prevent unregulated voltage, this series provides high EFT and ESD
protection. This also allows it to function in harsh environments, as well as
support power redundancy with a dual power input design with reverse polarity
protection.
With one model having an operating temperature of -10°C ~ 65°C, and another
with a wide operating temperature of -40°C ~ 70°C, this series is designed to
meet any needs for industrial automation application and harsh environments.
Key Features
Interface & Performance
- Copper port support auto MDI/MDI-X function
- Embedded 16*10/100/1000Base-T(X)
- Store-and-forward switching architecture
- 32K MAC Address Table
- Supports 9.6Kbytes Jumbo Frame
- 32Mbits memory buffer
Power Input
- Dual 24-55VDC redundant power inputs through M12 5-Pin K-Coded male connector, with SELV output certified by UL61010-2-201
- Max. current 1.18A
Certification
- CE/FCC
Operating Temperature
- Standard operating temperature model: -10°C ~ 65°C
- Extended operating temperature model (–T): -40°C ~ 70°C
Case/Installation
- IP67 protection
- Wall mount design
- Installation in a pollution degree 2 industrial environment
- Aluminum case
Package Contents
- 1 – EG5-1600-M12XB-(T)-67 – Unit weight: 4.034 kg (8.89 lb), Shipping weight: 4.756 kg (10.49 lb)
- 1 – M12 Protective Cap Set
- 1 – Quick installation guide
Safety Precaution
Attention
If the DC voltage is supplied by an external circuit, please use a protection
device on the power supply input. Supply by UL Listed industrial use power.
The industrial Ethernet switch’s hardware specs, ports, cabling information,
and wiring installation will be described within this user manual.
Attention
Si la tension CC est fournie par un circuit externe, veuillez utiliser un
dispositif de protection sur l’entrée d’alimentation. Fourniture par courant
industriel homologué UL. Les spécifications matérielles, les ports, les
informations de câblage et l’installation du câblage du convertisseur de média
industriel seront décrits dans ce manuel d’utilisation.
Warning Labels
The caution label means that you should check the certain information on user
manual when working with the device. (Shown in Figure 1.1)
Étiquettes d’avertissement
L’étiquette d’avertissement signifie que vous devez vérifier certaines
informations sur le manuel d’utilisation lorsque vous travaillez avec
l’appareil. (Montré dans la Figure 1.2)
HARDWARE DESCRIPTION
Physical Dimensions
Figure 2.1, below, shows the physical dimensions of EG5-1600-M12XB-67 series.
(W x H x D) is 295mm x 160mm x 101.3mm
Front Panel
The front panel of the EG5-1600-M12XB-67 series industrial gigabit Managed
Ethernet Switch is shown below in Figure 2.2. On the front panel, it provides
16 M12 connectors in a polka dot pattern to ensure easier plugging and safer
operation. The LED indicates various status by different colors and shapes of
the light. Besides, this series supports console, USB, DI/DO and dual DC power
inputs (24-55VDC) with M12 type connectors.
LED Indicators
There are LED light indicators located on the front panel of the industrial
switch that display the power status and network status. Each LED indicator
has a different color and has its own specific meaning, see below in Table
2.1.
LED | Color | Description |
---|
P1
|
Green
| On| Power input 1 is active
Off| Power input 1 is inactive
P2
|
Green
| On| Power input 2 is active
Off| Power input 2 is inactive
Status
| Green| On| No event happened after the last reset or reboot
Red| On| 1. System booting
2. Event happened by software setting
Red| Flashing| Firmware Upgrade
Master
|
Green
| On| ERPS Owner Mode (Ring Master) is ready
Off| ERPS Owner Mode is not active
Ring
|
Green
| On| ERPS Ring Network is active and work well
Flashing| ERPS Ring works abnormally or misconfigure
Off| ERPS Ring Network is not active
L/A
Port 01-16
|
Green
| On| Connected to the network with 1000Mbps
Flashing| Networking is active
Off| Not connected to network
Amber
| On| Connected to the network with 10/100Mbps
Flashing| Networking is active
Off| Not connected to network
M12 Interface (Auto MDI/MDIX)
- Connection Format: M12 8-Pin X-Coded Female Connector
- Transmission rate: 10/100/1000 Mbit/s
Prepare the M12 8-Pin X-Coded Ethernet Port mating cable for Ethernet connection. The M12 X-Coded Ethernet ports are auto-sensing for 10Base-T, 100Base-TX, or 1000Base-T devices connections. Auto MDI/MDIX means that you can connect to another switch or workstation without changing straight-through or crossover cabling. See pin assignment shown in Table 2.2
M12 8-Pin X-Coded Female Connector
| Pinouts| 10/100Base-T(X) Signal| 1000Base-T Signal
1| Transmit Data + (TX+)| BI_DA+
2| Transmit Data – (TX-)| BI_DA-
3| Receive Data + (RX+)| BI_DB+
4| Receive Data – (RX-)| BI_DB-
5| | BI_DD+
6| | BI_DD-
7| | BI_DC-
8| | BI_DC+
Table 2.2
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
Connection of Cables
Use the twisted-pair cable, category 5e or the above cabling for M12 port
connections. The cable between the Ethernet switch and the link partner
(switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
- Minimum Wire Gauge: 24AWG
- Maximum Transmission Length: 100m (328ft)
Caution: Please use with copper conductors only
Caution: Use conductors with insulation rated for at least 60°C
Attention: AVERTISSEMENT: EMPLOYER DES CONDUCTEURS POUR AU MOINS 60°C
Caution: Base the conductor Ampacity on a maximum termination temperature of 60°C
USB Port
- It is a M12 4-Pin A-Coded female connector
- USB Port is for configuration backup/restore
- M12 connector
M12 4-Pin A-Coded female Connector
| Pinouts| Function
1| DN
2| VBUS
3| GND
4| DP
Console Port
- It is a M12 5-Pin A-Coded female connector
- Baud rate 115,200bps, 8, N, 1
- M12 connector
M12 5-Pin A-Coded female Connector
| Pinouts| Function
1| NC
2| TX
3| RX
4| NC
5| GND
Power Inputs
This industrial Ethernet switch provides dual DC power inputs for redundancy
through M12 5-pin K-Coded male connector. Prepare the M12 5-pin K-Coded cable
for power connection. Table 2.3 shows the pin assignment.
M12 5-Pin K-Coded Male Connector
| Pinouts| Function
1| V1+
2| V1-
3| V2-
4| V2+
5| GND
Table 2.3
Connection of Cables
- Minimum Wire Gauge: 18AWG
Please follow the below steps to insert the power wire.
Step 1. Insert the positive and negative power wires into the power
connector on the industrial Ethernet switch with Power 1 (V1+, V1-), and Power
2 (V2+, V2-).
Step 2. Tighten the screw nut to prevent the connector from loosening
Relay Contact and Digital Input
The Ethernet switch is equipped a M12 5-Pin A-Coded male connector with a
normally closed relay contact for fault alarm and a digital input (DI). The
pin assignment of this connector is shown in Table 2.4.
M12 5-Pin A-Coded Male Connector
| Pinouts| Function| Description
1| DI+ Relay Com| Common
2| DI+| Digital Input +
3| DI-| Digital Input –
4| DI- Relay (N.C.)| Normally Closed
5| NA| Not Assigned
Connection of Cables
- Minimum Wire Gauge: 24AWG
Relay Contact
Relay is opened if any event listed below happens
- The current PoE outputs of all connected PDs exceed 240 Watts (for PoE models)
- Power 1 or Power 2 was inactive
- If any one of all PoE ports exceeds 30Watts (for PoE models)
- Event happened by software setting
Relay is closed under the conditions below
- No event after reboot
- No event after reset the switch
A connection of relay contact for fault alarm is shown below in Figure 2.3.
When the Ethernet switch is operating normally, the relay contact is a closed circuit. When the switch has any fault status (PoE overload or power failure), the relay contact circuit is opened and the FAULT LED lights up. In addition, even after even after the abnormal situation has been removed, the relay contact is still open and FAULT LED remains active, unless using the digital input to reset that. See the next section for information on Digital Input.
Digital Input (DI)
The digital input is used for monitoring two external events via an external
voltage source. When the voltage level on digital input pins changes from high
voltage to low voltage, the DI function will be triggered. Table 2.5 is shown
a detail specification of the digital input.
Specification | Description |
---|---|
Level 0 (Low) | -30~8VDC |
states)
Level 1 (High)| 10~30VDC| Normal Status (inactive trigger states)
Nominal input voltage| 24VDC|
Max. input voltage| 30VDC|
Nominal input current| 5mA (typical)|
Max. input current| 8mA|
Grounding Note
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the ground
screw to the grounding surface prior to connecting devices. The grounding
screw symbol is shown blow in Figure 2.4.
Caution: Using a shielded cable achieves better electromagnetic compatibility.
Bypass Function
This Ethernet switch supports bypass function by two Ethernet ports (P8 and
P16). When one of the Ethernet switches loses power, Ethernet ports (P8 and
P16) will bypass the power lost Ethernet switch to prevent the network from
disconnecting.
Take Figure 2.5 for example, if Switch B has power failure, the bypass function will be activated automatically, and it will bypass Switch B and bridge P8 to P16 of Switch B, so that the data transmission path (from Switch A to C) can remain connected and unaffected.
Reset to Default
Please perform the below steps to reset the switch to factory default setting.
Step 1. Reverse the Tx & Rx of the Console Cable and plug it into the
console port.
Step 2. Restart the power.
Step 3. The switch will start rebooting with the port LEDs flashing.
Step 4. When the Status LED turns into Green, the process is completed.
Step 5. Remove the reversed console cable.
MOUNTING INSTALLATION
Wall Mounting
Follow the steps below to mount the industrial Ethernet switch to a wall using
the screw holes as shown below in Figure 3.1.
Follow the steps below to learn how to hang the industrial Switch.
Step 1. Prepare 4 screws for mounting the switch to a wall.
Note: Recommended use the M5 screws.
Step 2. Based on the Figure 3.2: Physical Dimensions which is shown the positions of 4 screw holes on the left and right side of the switch to make 4 screw holes on a wall accordingly.
Step 3. Insert the screws through the screw holes on the switch and screw the switch into the wall. Shown above in Figure 3.1.
Step 4. To remove the switch from the wall, do the opposite from the
steps above.
Note: Make sure disconnect all cables from the switch before removing the
unit from the wall.
HARDWARE INSTALLATION
Installation Steps
This section will explain how to install EG5-1600-M12XB-67 series.
Installation Steps
Step 1. Unpack the industrial Ethernet switch from the original packing box.
Step 2. To hang the industrial Ethernet switch on a wall, please refer to the Mounting Installation section.
Step 3. Power on the industrial Ethernet switch and then the power LED light will turn on.
- If you need help on how to wire power, please refer to the Power Inputs section.
- Please refer to the LED Indicators section for LED light indication.
Step 4. Prepare the M12 cable for Ethernet connection.
Step 5. Insert one side of the M12 cable into switch’s Ethernet port and on the other side into the networking device’s Ethernet port. The Ethernet port’s (L/A) LED on the industrial Ethernet switch will turn on when the cable is connected to the networking device.
- Please refer to the LED Indicators section for LED light indication.
Step 6. When all connections are set and the LED lights all show normal, the installation is complete.
Caution: If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Caution: The installation that the safety to any system incorporating the equipment is the responsibility of the assembler of the system.
Caution: This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic.
Caution : This device is intended for use indoor and at altitudes up to 2000 meters.
Caution: Ambient Relative Humidity should be within the range of 5 and 95% (non-condensing)
TROUBLESHOOTING
- Verify you have the right power cord or adapter. Never use a power supply or adapter with a non-compliant DC output voltage or it will burn the equipment.
- Select the proper UTP or STP cable in order to construct the network. Use an unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 5e for 10M/100/1000Mbps. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
- Diagnosing LED Indicators: To assist in identifying problems, the Switch can be easily monitored with the LED indicators which help to identity if any problems exist.
- Please refer to the LED Indicators section for LED light indication.
- If the power indicator LED does not turn on when the power cord is plugged in, the user may have a problem with the power cord. Check for loose power connections, power losses or surges at the power outlet.
- Please contact Leonton for technical support service, if the problem still cannot be resolved.
- If the industrial Switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit, please check the system’s Ethernet devices’ configuration or status.
For any repair or maintenance needs, please contact us.
LEONTON TECHNOLOGIES, CO., LTD 9F-1, No.43, Fuxing Rd., Xindian Dist.,New
Taipei City, 231, Taiwan
TEL: +886 2 22183113
FAX: +886 2 22187391