PREM-I-AIR EH1413 4.3kW Portable Air Conditioner User Manual

June 3, 2024
PREM I AIR

EH1413
Portable Air Conditioner

Split-unit air conditioner
4.3kW (15000 BTU/hour) cooling capacity
User Manual

EH1413 4.3kW Portable Air Conditioner

IMPORTANT
installer and Users please note:
These instructions should be read carefully and left with the user of the product for future reference.
BEFORE USE
Inspect the product including its cable and plug for any signs of damage. If the product is damaged, DO NOT use it, and contact your supplier immediately.
INSTALLATION
Transport and store in an upright position. Leave the appliance in an upright position for at least 3 hours before first use.

PRODUCT SAFETY

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction conceming use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance
  • Ensure that there is at least 300 mm (1′) between the sides of the appliance and any flammable materials
  • Ensure that there is at least 900 mm (3′) from the top of the appliance and any flammable materials.
  • Do not place on soft surfaces.
  • For indoor use only
  • Not suitable for use in boats, caravans or similar locations.
  • Do not use in bathrooms, or in wet locations.
  • Do not place the mains lead beneath a carpet or rug.
  • Do not use the product in locations where paint, petrol or other flammable liquids are used or stored.
  • Do not use unless correctly installed
  • Do not use without the Air Filter Installed
  • Dono insert any object into the appliance through the grilles. This may damage the product or result in electric shock.
  • Do not obstruct the air intake and exhaust vents on either internal or external appliance.

WARNINGS FOR YOUR SAFETY

  • Do not store or use petrol or other flammable vapours & liquids in the vicinity of this appliance
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flame, an operating gas appliance or an operating electrical heater, etc.)
  • Do not pierce or burn the appliance.
  • Be aware that the refrigerant may not contain an odour.
  • The appliance should be installed, operated and stored in a room with a floor area larger than 10 m’.
  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation shall be left with the appliance.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid FGAS certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safety in accordance with FGAS regulations.
  • The after service shall only be performed by a qualified engineer. The maintenance and repair requiring the assistance of skilled or qualified personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

Select a location for the internal unit – it should be clese to a door or opening window to allow the exterior unit to be placed outside, but not too close to a wall  2836 Ver. 2 – 03/22 to avoid obstructing the air flow. Allow 30cm (8″) around the appliance on all sides, to achieve optimum efficiency and lowest operating noise. The external unit
is suitable for permanent installation outdoors.
Pass the extemal unit through the open door or window, and then close the door or window to the minimum gap that will allow the flexible hose through.
If the appliance is to be used frequently in the same location, then the bracket can be attached to the exterior wall, and the external appliance can be hung on the bracket. See installation diagram below.

The intemal and external units must remain connected by the flexible hose at all times. The flexible hose may only be disconnected by persons with the necessary qualifications under the “F Gas Regulations’.

INSTALLATION AND OPERATION

If the remote control is to be used, install two AAA batteries into the battery compartment, ensuring the correct polarity. Plug the mains lead into a 13 Amp mains socket.
If connecting via an extension lead, make sure that the lead is rated at 13 Amps or more, and that it is fully unwound. Switch the appliance on at the mains socket. Press the “( )” button to start the appliance
Select the mode by pressing the “MODE” button. The available modes are:

  • AUTO: Automatic mode: selects the optimum fan speed to maintain the selected room temperature.

  • HI/MED/LO: Selects high, medium or Low fan speed.
    o Set the required room temperature using the THERMO CONTROL buttons. The set temperature is displayed on the LED display. Cooling modes only.

  • DEHUM: Dehumidifier setting; in this mode there is no cooling and the fan speed is selected automatically.

  • FAN: Fan only mode with no cooling.

AUTO SWING: Selects up and down movement of the louvers.
THERMO CONTROL: The default temperature setting is 25°C, use these buttons to select the desired room temperature (16°C – 30°C). When the temperature teaches the desired figure the compressor will stop and the unit will operate as fan only till the temperature rises sufficiently for the compressor to restart.
TIMER: The timer can operate as countdown until the unit turns off or as a countdown until the unit turns on.

  • TIMING OFF: To set the hour you want the unit to turn off, press the TIMER SET button when the unit is “ON”. And the TIMING OFF indicator will illuminate, set the the time till the unit switches off by repeatedly pressing the TIMER SET button (1 hour intervals). When the set time has elapsed the unit will switch OFF. Pressing the power “(” button at any time whilst the timer is set will cancel the timer setting and the unit will turn OFF.
  • TIMING ON: To set the hour you want the unit to tum ON, press the TIMER SET button when the unit is “OFF”. And the TIMING ON indicator will illuminate, set the time till the unit switches ON by repeatedly pressing the TIMER SET button (1 hour intervals). When the set time has elapsed the unit will switch ON. Pressing the power “ ” button at any time whilst the timer is set will cancel the timer setting and the unit will turn ON.
    The timer function can be cancelled at any time by pressing the RESET button.

If the DRAIN WATER indicator illuminates, place a container underneath the end of the water drain tube (on the back of the intemal appliance) and remove the bung. Allow the water to drain out, and then replace the bung.

USING THE REMOTE CONTROL

The operating modes are selected in exactly the same way as using the contro! panel on the main appliance. To operate the remote control, make sure that it control is pointed at the window in the front panel labelled “REMOTE”.

  1. ON/OFF Button
  2. MODE Button
  3. FAN Speed Button
  4. TEMPERATURE CONTROL Button
  5. TIMER Setting Button
  6. AUTO SWING Button

MAINTENANCE

Before cleaning, turn the appliance off using the button on the control panel (NEVER switch off the power at the mains socket whilst the appliance is running). Wait until the appliance stop and then disconnect from the mains supply. The case may then be cleaned using a damp cloth with a drop of washing-up liquid to remove any dust or dirt from the case. Do no use stronger detergents or solvents as these may damage the plastic.
Using a dry 1° (25 mm) paint-brush, remove any dust from the grilles.
Every two weeks, clean the air filter; the filter is located at the back of the appliance towards the top. Remove the filter, and wash with hand-hot water with a drop of detergent. Dry thoroughly before replacing.
Using the EH1413 with a blocked filter will severely reduce its efficiency, and using without the filter may lead to a build-up of a dust on the heat exchangers, which may constitute a fire hazard.
This unit contains a highly flammable refrigerant gas and as such any repair, re- gassing of this unit should ONLY be performed by qualified personnel with required certification and experience. There is a high risk of fire or explosion if any repair is attempted by unqualified personnel.

LONG TERM STORAGE

  • Drain the water from internal unit through the drain tube on the rear
  • Run the unit for 3-4 hours on FAN only operation to fully dry the inside of the unit
  • Carefully wrap the power lead away
  • Clean all the filters and cabinet
  • Cover the unit to protect from dust
  • Store the unit in a cool dry place in an upright position, away from sunlight

lf the mains lead is damaged, it must be replaced by the manufacturer or an authorised service centre. If the mains plug needs to be replaced, proceed as follows:

  • Connect the brown wire to the terminal labelled “L’.
  • Connect the blue wire to the terminal labelled “N”
  • Connect the green/yellow wire to the terminal labelled with the earth symbol or “E”.
  • Make sure that the cord-grip is positioned correctly (over the outer sheath of the cable) and it fully tightened.

OPERATING COSTS

At time of going to press, the average cost of electricity is £0.14 per appliance ({kilowatt-hour). The amount you are being charged will be shown on your electricity bill.
At this cost, the EH1413 will cost a maximum of £0.17 per hour to run; the actual amount will depend on the .t temperature, and t. room temperature.
GENERAL SAFETY REQUIREMENTS
Domestic wiring must be t.t. periodically by a qualified electrician at least on. every 10 years or at every change of oc.pancy. For office and retail premi.s, and buildings such as village halls, the wiring must be inspected at I.st once every 5 years. It is recommended that all building be fitted with smoke alarms (it is mandatory for new buildings).
PAT TESTING.
When used in an office environm.t we re.mrnend that this product should be safety-tested yearly by a qualifi. electrician (PAT Tested). :Vnevirro=end that It is PAT tested regularly when u.d in a domestic
DISPOSAL AND RECYCLING
You rnust not dispose of this applian. with domestic household waste. Most local authorities have specific collect. system for appliances and disposal is fr. of charge to the end-user. When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for dispo.l. This air conditioner contains R32 refrigerant gas. At the end of its life the disposal of this product must be in accordance with local regulations.
FAULT-FINDING
If the EH1413 is not operating, proceed as folbws: Check that the mains plug is firmly in the socket, and that the socket is switched ON. When the appliance if switch. on there will be a delay of about 1 minute before it starts to operate.

  • Appliance stops running: Target temperature .s been reached. Timer has been set.
  • In cooling rnode, no cool air is produced: Room temperature is lower than set temperature The appliance is defrosting (this will take a few minutes, and afterwards, it will resume operation)
  • Remote control does not work: Check batteries are correctly installed, and are not exhausted. Make sure that the remote control is pointed towards the appliance when being used. 

TECHNICAL SPECIFICATION

Dimensions (internal unit): 470.335×695 mm
Dimensions (external unit): 510×230.490 mm
Weight (internal unit): 38 kg
Weight (external unit): 12 kg
Cooling capacity: 4.3 kW (15000 BTU/h)
Power supply: 230 V—
Power consumption: 1.37 kW
SEER (For Cooling) 47
Dehumidifying capacity: 45 litres/day
Operating current: 5.4A
Air volume: 490 m3/hour
Refrigerant: R32(970 g)
Noise(max) Indoor 57dB (A) Outdoor 62dB (A)

SERVICE WARRANTY

Prem-i-Air guarantees the product free from defects in materials and workmanship for a period of twelve months.
Should this appliance be operated under conditions other than those recommended, at voltages other than the voltage indicated on the appliance, or any attempts made to service or modify the appliance, then the warranty will be rendered void.
The product you buy may sometimes differ slightly from illustrations. This warranty is in addition to, and does not affect, your statutory rights.
If you have any problems with this product, please call our Help Desk on (0845) 459 4816.

Prem-i-Air Appliances Ltd., Lancots Lane, Sutton, St.
Helens, Merseyside.
WAQ 3EX, UK
www.prem-i-air.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals