SAFETY INFORMATION

  • RISK OF ELECTRIC SHOCK – Use only in dry locations and only indoors.
  • DO NOT plug into another relocatable power tap.
  • DO NOT “daisy chain” surge protectors.
  • DO NOT plug into 220V outlet or power source
  • DO NOT use with any aquarium equipment.
  • DO NOT connect to an ungrounded outlet
  • DO NOT install this device if there is not at least 30 feet (10 meters), or more of wire between the electrical outlet and electrical service panel.
  • This device features internal protection that will disconnect the surge protective component at the end of its useful life (PROTECTED LED WILL TURN OFF) , but will maintain power to outlet – WHICH WILL BE UNPROTECTED. If you don’t want your equipment at risk, the surge protector will need to be replaced.
  • DO NOT use in any circumstance that would affect the operation or reliability of life support equipment, any medical applications, or patient care.

PRODUCT FEATURES

  1. Dual USB Charging Ports: 5V 2.4 Amp Total USB-A ports for charging compatible devices
  2. PROTECTED LED—If illuminated, the unit is working properly. If not illuminated your connected equipment is not being protected. Contact ELAC Customer Support
  3. AC Outlets—Plug Equipment directly into these outlets. Do not use an extension cord, UPS, or power strip.

USING YOUR SURGE PROTECTOR

  1. Ensure the power is off on the devices you will connecting to the AC outlets on the surge protector.
  2. Plug the surge protector into a properly grounded AC wall outlet.
  3. Check that the PROTECTED blue LED light is illuminated. (If not the surge protector is not operating properly and will not protect your connected devices).
  4. Plug your equipment into the outlets on the surge protector and power on your devices as usual.
  5. USB devices can be charged/powered by simply connecting the USB power cord to USB ports on the surge protector. The USB ports deliver 5V and up to 2.4amps of power.

TECHNICAL SPECIFICATIONS

  • Number of Outlets: 6
  • Number of USB Ports: 2—5V total 2.4A
  • AC Outlets: All 6 filtered with surge protection
  • Protection Modes: L-N, L-G, N-G
  • Thermal Fuse: Yes
  • Maximum Current: 15 Amps
  • Line Voltage: 120V @ 60Hz
  • Certification: UL 1449, UL 498A, FCC, ICES
  • Max Energy Dissipation: 540 Joules
  • Max Spike Voltage / Current: 6,000V / 36,000A
  • Response Time: 1 Nanosecond
  • Filtration: EMI / RFI 40dB

EMI / RFI Noise Filtration
AC power from your power company can become noisy on its way to your home and ultimately to your equipment. Static electricity, certain appliances in your home can all introduce noise into you homes electricity. All 6 outlets of the PB-62S offer 40db of noise reduction providing your sensitive electronics with clean power.

Dual USB Charging Ports
Delivering up to 2.4 amps, the PB-62S not only protects your sensitive electronics from AC surges but also offers the convenience of USB charging. Simply connect your USB devices to the USB ports on the front of the PB-62S.

Surge Protection
Power surges can originate both inside and outside the home. When your home loses power or the power company performs a grid switch a surge of power can enter your home. When higher power devices, such as an air conditioner, hair dryer, or electric oven are turned on and off can also cause a spike of voltage throughout your homes electrical system. The PB-62S offers up to 540 Joules of surge protection and reacts to surges in 1 nanosecond.

Protection LED
The protection LED on the front of the PB-62S lets you know your electronics are protected.

PB-62S SPECIFICATIONS

LINE VOLTAGE 120 Volts
MAX CURRENT RATING 15 Amps
NUMBER OF AC OUTLETS 6 Total
NUMBER OF USB PORTS 2 (2A amps total)
INDICATOR LEDS Protected
SURGE ENERGY JOULE RATING 5401
RESPONSE TIME 1 Nanosecond
MAX SPIKE CURRENT 36,000 Amps
MAX SPIKE VOLTAGE 6,000 Volts
L-N, L-G, N-G PROTECTION Yes
THERMAL FUSING Yes
NOISE FILTER EMI /RFI 40 dB
COMPLIANCE IL 1449, UL 498A, FCC, IEC

This surge protector is designed to protect your electronic equipment from AC power surges up to its rated specifications only. If an electrical surge above the rated specifications of this surge protector enter this device, connected devices may not be protected. Please understand that electrical surges can enter electronics devices through any interconnected conductive connections. These interconnections can include coax lines, phone lines, ethernet lines, AV connections and any other conductive material.

* For full details regarding the Connected Equipment Guarantee please visit www.elac.com

$50,000 Connected
**Equipment Guarantee***

ELAC PROTEK CONNECTED EQUIPMENT GUARANTEE

ELAC Americas Inc.
1938 N. Batavia Street, Suite K, Orange, California 92865 USA Connected Products Guarantee for Protek Surge Suppressors

In addition to the applicable Limited Warranty, ELAC Americas Inc. (“ELAC”) provides this Connected Products Guarantee in the event that damage is caused to equipment while it is plugged into the covered Protek Surge Suppressor (“Suppressor”), and the damage is determined to have been caused by a Suppressor defect in materials or workmanship.

You are agreeing to all of the terms and conditions of this Guarantee when you purchase a Suppressor, and if you do not agree to these terms and conditions you should return the Suppressor for a refund.

Conditions to Guarantee

  • This Guarantee is only available to Suppressor customers in the United States.
  • All Claims must be made within fifteen (15) days after the date of the incident when the damage was caused, even if the damage was discovered at a later date.
  • Suppressor’s serial number must not have been removed or defaced.
  • Suppressor must not have been modified or altered, or been subject to abuse or faulty equipment.
  • Customer’s use of Suppressor must have been in compliance with all instructions, conditions, and warnings provided or published by ELAC, including without limitation the Suppressor user manual.
  • Suppressor must have been undamaged and in its original condition at the time of the incident when the damage was caused.
  • Suppressor must be determined by ELAC to be defective in materials or workmanship, and the damage to connected products must have been proximately caused by the defect(s).
  • Damage to connected products must have been caused while plugged into a Suppressor, when there was a spike or surge on a connected properly installed 120V AC power line.
  • Damage to connected products that is caused by an AC power surge above rated specifications for the Suppressor is not covered.
  • The Suppressor must have been directly (e.g. not through a plug or extension cord) plugged into a properly-wired and grounded outlet at the time of the incident, and all connected products must have been directly plugged into such Suppressor (e.g. not through a plug, extension cord, or daisy-chain of suppressors) .
  • The environmental conditions for use of the Suppressor and connected products must be suitable for normal use and operation.
  • This Guarantee only covers connected products for personal, home applications and not commercial use.
  • Damage to Suppressor and/or connected products that is caused by environmental conditions such as flood, fire, rain, extreme temperatures, or pests will not be covered.
  • Suppressor must not have been repaired by a non-authorized repair facility prior to the incident when damage was caused.

Claim Limitations

  • This Guarantee does not cover, and ELAC will not be responsible for, liability or damages related to personal injury or death.
  • This Guarantee does not cover, and ELAC will not be responsible for, liability or damage to software, data, or electronic records.
  • This Guarantee does not cover, and ELAC will not be responsible for, lost profits or business interruption.

How to Make a Claim

Contact ELAC at 714-252-8843 or at customerservice@elac.us to make a claim under this Guarantee (“Claim”).

Customer is required to provide ELAC with reasonably requested information or items necessary to validate the Claim. Please have the following information ready when you contact ELAC:

  • Proof of purchase of Suppressor (Copy or original sales receipt).
  • Model number of the Suppressor.
  • Manufacturer and Model number(s) of damaged equipment.
  • Specifics regarding the date, time, location, power supplier, and other conditions relating to the incident when the equipment was damaged.
  • Any other guarantees, insurance policies, or sources of reimbursement available to customer.
  • Estimate of loss or damage to connected products.

Customer will be required to return the Suppressor for inspection before a Claim is approved, and may be required to return connected products and/or make the incident site available for inspection. Shipping costs shall be borne by Customer and will be in accordance with ELAC’s instructions.

Valuation of Claim

  • ELAC’s entire liability, and Customer’s sole recovery, under this Guarantee, shall be limited to the recovery as set forth in this Valuation of Claim section.
  • If the Customer’s Claim is accepted, at ELAC’s discretion, ELAC will either (a) repair, (b) replace, or (c) reimburse Customer for the Value of connected products in accordance with the following formula. Once ELAC has satisfied the Claim, at ELAC’s request, Customer agrees to transfer all connected products to ELAC.
  • The value of the Claim for connected products (“Value”) shall be calculated as follows:
    • The lower of (i) the Maximum Claim Value amount set forth in Exhibit A (for the particular model Suppressor); (ii) the lowest price that the same or similar items can be purchased new in the United States; (iii) the average price that the same or similar items can be purchased used in the United States; or (iii) the price of the item in the Orion Blue Book (or a similar used price list selected at ELAC’s discretion); where such amount determined by (i) – (iii) shall be decreased by all amounts Customer has or is entitled to receive from other sources of coverage, such as insurance or extended warranties.
  • This Guarantee is not “first dollar” coverage, and therefore ELAC’s responsibility and liability is reduced by amounts Customer is entitled to recover from other sources.
Disclaimers

OTHER THAN THIS GUARANTEE AND THE APPLICABLE LIMITED WARRANTY, ELAC MAKES NO OTHER WARRANTIES, AND HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS. ANY IMPLIED WARRANTIES THAT ARE IMPOSED BY LAW ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY.

Some jurisdictions do not allow the exclusion of implied warranties, so this disclaimer may not apply to you.

IN NO EVENT WILL ELAC, NOR ITS PARENTS, SUBSIDIARIES, OR AFFILIATES OR SUPPLIERS BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY INCIDENTAL, CONSEQUENTIAL, SPECIAL, INDIRECT, PUNITIVE, LOST PROFIT, BUSINESS INTERRUPTION OR EXEMPLARY DAMAGES, WHETHER FOR CONTRACT, TORT OR OTHERWISE, EVEN IF ELAC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Binding Arbitration
Customer and ELAC acknowledge and agree that any claim, dispute or controversy arising out of or relating to this Guarantee or the applicable Limited Warranty shall be resolved EXCLUSIVELY and FINALLY by binding arbitration administered by the American Arbitration Association’s Consumer Arbitration Rules.

The application of the United Nations Convention of Contracts for the International Sale of Goods is excluded.

EXHIBIT A
MAXIMUM CLAIM VALUE AMOUNTS

Model

|

Maximum Claim Value

---|---
PB-62S| $50,000
PB-30S| $50,000
PB-82S| $100,000
PB-62W| $100,000
PB-12W| $100,000
PR-71S| $500,000
PR-81B| $500,000
PR-91W| $500,000

Copyright 2021 ELAC Americas Inc.