INTRODUCTION AND SAFETY
F2 Fires Limited and Paul Agnew Designs have created this stove to exceed our
customers’ expectations. Functionality, design and high quality are the main
priorities for our entire range of superior appliances and related products.
It is our extensive experience and knowledge that ensures your home will be
warm and cosy for many years to come. Sitting in the light and warmth of the
fire ,you will understand that we simply Create Atmosphere.
This manual is for the 5kW Accona Stove, which is designed to be used as a
Freestanding stove. Throughout this manual, we will refer to this model as the
‘appliance’. To further appreciate your new appliance please read the
following carefully:
This appliance is designed, tested and manufactured as a closed stove for
burning wood to BSEN13240standard, smoke less fuel and anthracite. F2 Fires
recommends that this appliance Is installed by a HETAS registered installation
engineer or a competent person only and failure to comply will invalidate your
warranty.
Safety – Installation
Installation of your appliance must comply with all local building
regulations, including those referring to UK National and European Standards.
We advise prior to any installation that a full site survey is conducted by a
qualified installation engineer, recognized within an industry standard such
as NACS or HETAS, to check the suitability of your chimney and appliance
beforehand.
Within the UK, Document J of the Building Regulations contains further
information regarding the installation of solid fuel appliances. This can be
viewed by searching for ‘Planning Approved Document J’ online at www.gov.uk
within the United Kingdom. You should also check the relevant planning and
building regulations in your own country and your local area, as they may
differ from UK National regulations.
Safety – Ventilation
In order for smoke to be drawn up the chimney, the correct amount of
ventilation is required. A chimney requires air movement to work correctly,
which is not possible if there is an inadequate source of air. Prior to
installation, you should ensure that your appliance has the correct conditions
in order to operate as intended.
Other heating appliances that also require air for combustion should not be
used in the same room as this appliance, unless adequate additional
ventilation is provided.
For combustion and the evacuation of dangerous flue gases ,this appliance
requires a supply of air. Without adequate air supply, the appliance will not
operate correctly and smoke may escape back out into your house.
Any air inlet grilles should be positioned so that they are not liable to
becoming blocked. Ongoing maintenance of the air inlet systems is essential to
ensure the continued safe operation of this appliance.
An air extraction device should not be used in the same room as this
appliance, unless adequate additional ventilation is provided. Extractor fans
when operating in the same room or space as the appliance may cause problems
with the extraction of dangerous flue gases.
We recommend that you discuss your ventilation and installation requirements
with your local F2Fires authorized retailer if you have any doubts or queries.
Images within this manual will not necessarily be exactly as the model
referenced, and may be subject to change.
Safety – Clean air act 1993and smoke control areas
Under the Clean Air Act, local authorities may declare the whole or part of the district of the authority to be a Smoke Control Area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler, if located in a designated smoke control area. It is also an offence to acquire an “unauthorized fuel” for use within a smoke control area unless it is used in an “exempt” appliance (“exempted” from the controls which generally apply in the smoke control area).
In England, appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. In Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the
Regulatory Reform (Scotland) Act 2014.Similarly, In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture ,Environment and Rural Affairsunder Section 16of the Environmental Better regulation Act (Northern Ireland) 2016.In Wales appliances are exempted by regulations made by Welsh Ministers. Further information on the requirements of the Clean Air Act can be found by searching for ‘Smoke control area rules ‘online at www.gov.uk within the United Kingdom.
Your local authority is responsible for implementing the Clean Air Act 1993including designation and supervision of smoke control area sand you can contact them for details of Clean Air Act requirements.
Our appliance – the 5kW Accona multifuel stove, has been recommended as suitable for use in smoke control areas when burning wood logs. All appliances have been fitted with a modified air control to prevent closure of the secondary air control beyond 6mm (30%) open.
Please note the following guidance :
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel
charge, excessive smoke emission can occur. Refueling must be carried out onto
a sufficient quantity of glowing embers and ash that the new fuel charge will
ignite in a reasonable period. If there are too few embers in the fire bed,
add suitable kindling to prevent excessivesmoke.
Fuel overloading
The maximum amount of fuel specified in this manual should not be exceeded,
overloading can cause excess smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be
operated with the appliance door left open except as directed in the
instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess
smoke. The appliance must not be operated with air controls, appliance dampers
or door left open except as directed in the instructions.
BEFORE YOU START
First, check the load bearing capacity of your floor
Before installing the appliance, you must ensure that the load bearing
capacity of the floor is equal to the weight of the appliance, as well as any
flue pipes and connections. The weight of the appliance is75kg approximately
when empty. Remember to also account for the additional weight once the
appliance contains the internal components and fuel. Ensure the suitability
of your hearth
The appliance should be installed on a minimum 12mm thick, non-combustible
hearth. The hearth should extend to a minimum distance of 225mm in front of
the appliance and 150mm to each side, measured from the door of the combustion
chamber. Please refer to document J of the building regulations for further
information on hearth requirements. Check clearance to combustibles
The minimum clearance to combustible materials is 450mm on
bothsidesoftheappliance,150mmtotherearoftheappliance when additional collar
convector panel is used.
A minimum of 50mm clearance should be left at the back and
sides of the appliance to allow free air movement and for heat to enter the
room. The are should be a minimum clearance
around the 5”flue pipe of 175mm radius above the appliance.
Inspect your chimney
An existing chimney or a new flue installation should be given a visual
inspection to check that it is in good order, clear of obstructions and is of
a suitable size and type for the appliance. It is essential to first sweep the
flue before fitting the appliance or lining a chimney. Inspect your
airflow
In order for smoke to be drawn up the chimney, ventilation into the room is
required. Normally, sufficient air will come into a room naturally, however in
some modern passive homes, there may be a need for additional ventilation. A
chimney requires air movement to work, which may not possible if there is an
inadequate source of air. Prior to installation, you should ensure you have
the correct conditions in order to operate this appliance.
Item check list
Cast Stove Body
The appliance is a single unit and is very heavy. See Lifting warnings below.
Allen Key
For making door adjustments if necessary.
Glove
For ensuring safe operation of the handle when the appliance is hot.
Safety check list
TAKE CAREWHEN LIFTING- 80kg
This product weighs 80kg. Take necessary precautions and care when lifting and
handling this appliance. A minimum of two competent people will be required to
lift and manipulate this appliance into position. Firstly, ensure the area is
clear and free from obstructions. Check the appliance is secure and stable
when moving and that you are wearing adequate safety gear.
ENSUREYOU HAVE AN APPROVED CARBONMONOXIDE ALARM FITTED
An approved carbon monoxide alarm with a 7-year life sealed or replaceable
battery must be installed before any Solid Fuel appliance is installed. Carbon
monoxide alarms need to meet European safety standards and must be audible.
They must be fitted in accordance with the manufacturer’s instructions. Please
Note: Regular maintenance and chimney sweeping is still essential.
The appliance must not be modified in any way Any changes will invalidate your warranty and may damage the appliance or cause an unforeseen safety issue. Any replacement parts that you may require over the lifetime of the appliance must be official F2 Fires appliance parts ONLY.
Considerations
Test the chimney thoroughly
We recommend that a smoke test is carried out to check for gas tightness
within your flue and for chimney draughts. Lining and insulating your chimney
before installation is highly recommended. Ensure there is adequate access to
the chimney to allow for sweeping on a regular basis.
Consider additional ventilation
We strongly recommend that you consider ventilation requirements before
installation of your appliance. If your appliance smokes or does not burn very
keenly, but improves noticeably when you open a window, this is a sign that
you need to install additional ventilation. See Ventilation – Introduction and
Safety section for more information.
Suitability
Make sure that the area in which the appliance is to be fitted is suitable for
this appliance. Walls adjacent to the appliance should be of a suitable non-
combustible construction material, preferably brick, as this appliance can
reach external temperatures of up to and above 300°C. Check adequate
precautions are taken to prevent touching hot appliances. Always use adequate
heat proof protection, such as the supplied glove, when operating the metal
handle as it will become hot during use and for some time afterwards.
Air Damper
It is recommended that chimneys with a strong up draught be fitted with a flue
damper or draught stabiliser to allow the chimney draught to regulate
properly. No damper should close the flue way completely – not less than 20%
of the total chimney or flue pipe should remain open at all times.
INSTALLATION AND TESTING
Adjusting the handle
Adjustment points on the appliance
The door handle has a sophisticated adjustment system, however, it comprises
of only 4 parts and can be adjusted very simply from the outside. Over time,
the door rope will flatten and the seal may start to let uncontrolled air into
the appliance. This may allow unwanted air into the combustion box and could
increase the speed of the burn. This will affect the controllability of the
appliance and at this point, you should adjust the handle;
Insert the supplied Allen key into the hole in the side of the door containing
the set-screw. Turn it anti-clockwise to slacken the set-screw until the door
handle becomes loose. Once loose ,turn the handle the correct way as shown in
the drawing to the left. On completion, slowly re-tighten the set-screwuntil
the handle
is set properly and the door shuts tightly again.
Fitting and connections
Adjustment points on the appliance
This is a free standing appliance designed to be suitable for 12mm hearths.
Once the flue is in position the appliance should be secure. However if the
floor surface is uneven, additional fixings are supplied to allow the
adjustment of the four feet. Always ensure the appliance is level and secure
after adjustments are made. Flue connections
This appliance has a top outlet. The minimum flue draught required for nominal
heat output is 12Pascals.
At nominal heat output, the flue gas temperature will be in the region of
242°C. The appliance should never be connected to a shared flue. Seal the flue
connections with fire cement or a high temperature rope seal. The flue
blanking plate should be positioned over whichever outlet is not being used.
A register plate (not supplied)maybe required to seal off the throat of the
fireplace and has a hole for a flue pipe. It also provides access for sweeping
and ,if required, has a connection for a bracket to support the flue .A 5”
(127mm)flue pipe is required from the appliance to the register plate. Consult
your installation engineer if you require one.
Testing
Testing points
This appliance has a flue test point which has various functions:
- Helping to ensure correct installation and aiding the installer to set up the Accon a with the flue-pull in order to match the manufacturer’s recommendations. See Safety – Ventilation.
- For measuring the flue-pull during servicing to check for soot or tar buildup in the chimney.
The test point is situated discreetly at the top right hand side of the appliance. The M8 screw can be removed and a flue test meter can be placed in the hole in order to measure the flue-pull. On completion, always ensure the M8 screw is re-fitted.
OPERATION
Lighting
Before lighting the appliance
Before lighting the appliance for the first time, please ensure all firebrick
linings and other internal components are in position and that all packaging
has been removed.
When lighting your appliance for the first time, it should not be stoked
excessively as the materials must be given time to adapt to the effects of
heat. Your appliance has been painted with specialist High Temperature paint
and oven cured during the manufacturing process. However upon initial lighting
of the appliance, further curing may occur and a slight smell may be evident.
We recommend that windows and doors are left open during this time, which will
allow the smell to dissipate.
Step 1 Place rolled up crumpled paper at the back of the appliance. Next, place a small amount of tinder/kindling on top of the paper followed by a few larger pieces of wood. Light the paper and close the door. NEVER USE FLAMMABLE LIQUIDS
Step 2 Open the front air control (Primary air) fully, using the glove provided. On the SP model, turn the spinner anti-clockwise to open. On the SL model, push the slider to the right to open.
Step 3 Allow the fire to burn until all the pieces of wood are alight and burning. The top air intake (Secondary air) can be used if additional air is needed. Push the slider to the left to open. More larger pieces of fuel can now be added. Be careful not to add so much fuel that it is in danger of overflowing the fuel bar or touching the glass.
Step 4 Once the fire is established, both air controls can be reduced in order to maintain a steady burn rate dependent on your fuel type. On the SP model, turn the spinner clockwise to close. On the SL model, push the slider to the left to close. Push the top air intake to the right.
REMEMBER:
You should never run the appliance with the door open.
HOT SURFACESDURING OPERATION
All parts of the appliance will become hot during use. Always use the glove
provided to operate any element on the appliance, especially the air control
and the door handle. Once lit, ensure that adequate precautions are taken to
ensure that others ,including children, pets and combustibles cannot come into
contact with any of the appliances’ hot surfaces.
How to light and sustain a fire
First stage
The fire is usually smokiest just after lighting due to the coldness of the
wood and appliance, which can take heat away from the flames. During this
stage, ensure that the primary air inlet is fully open to increase the flame
temperature and initial heat. Heat will escape straight into the flue system,
however, this is a necessary part of starting an efficient fire. The inbuilt
tertiary air supply inside the appliance is non-adjustable. Using the primary
and secondary inlets allows you to increase air above and beyond what the
inbuilt tertiary air system supplies.
Initial heat
The additional heat at the first stage will prime the chimney, producing a
strong draught. It will also help to keep the chimney or flue clean by
loosening anything deposited during a previous fire. The hot initial burn also
drives moisture from the firewood and gives an ignition source for the smoke
that is released from the wood.
Adding fuel
When adding fuel, only make small, gradual changes .Do not add too much fuel
at once. Adding fuel gradually will help to maintain a steady optimum
temperature and burning rate so that the appliance burns efficiently and
cleanly . Adding too much fuel will also dramatically reduce the temperature
inside the firebox. After adding large pieces of fuel, it is recommended that
you increase the air opening slightly so that the new fuel begins to burn and
the appliance returns to optimum operational temperature.
This also applies to the air control. Adjusting it gradually will help
maintain a steady combustion rate. In most instances,you will arriveat the
best combustion air settings yourself,as the height and diameter of the
chimney, as well as the quality of the fuel used are decisive factors in
determining your appliance’s efficiency.
Small hot fires are more efficient than large slumbering ones. Most of the
energy in burning wood is released as a bright flame.The turbulence in the
flames createsgood mixing between the combustion air and the gases that are
released from the wood as it heats up.The heat of the fire ignites and burns
these gases.In contrast,the dense smoke from a slow, smouldering fire is
potential heat energy that can escape up the chimney and either cling to the
chimney flue or pollute the atmosphere with unburnt carbons.
To gain the most heat from each burn,the fuel should be flaming throughout the burn cycleuntil it is reduced to ash.Should any regular slow-burning occur,it is always good practice to burn a hot fire at regular intervals to keep the chimney clean and dry.When refuelling, always place the fuel towards the back of the appliance where it will burn at a higher temperature.
The removal of ashes
The ashes should only be removed when the fire is out and has been left to
cool completely. The log retaining bar can be removed for easier access by
lifting it up. Wood burns well on a thin layer of ash and leaving this behind
when cleaning will provide protection for the base and insulating bricks, thus
prolonging their life.
NEVER attempt to remove the ashes when the stove is hot or warm.DO NOT attempt to remove ashes directly after use. Allow the stove and ashes to cool down fully before attempting any maintenance. As he scan remain hot even when they appear to be no longer lit. Please ensure you use the correct tools to dispose of them safely, and if you are unsure, allow them to cool further before attempting to remove them.
Types of fuel
Wood
Wood needs to be well seasoned before it is burnt. For the best performance,
you should use kiln dried wood or seasoned wood with no more than 20% moisture
content. As a general guide, wood should be cut to length, split and then
stacked under cove outside with the sides open to the air, for at least
12months.You can tell that wood is ready for burning when radial cracks appear
at the end of the logs.
It is then good practice to store the wood in a log basket inside your
property for a few days prior to its use. The internal width of the firebox of
the Accona is 300mm, therefore firewood should be no longer than this and a
little shorter to aid refueling.
Smokeless Fuel
There are several types of smokeless fuel, we recommend only smokeless coal,
coke or briquettes that are HETAS approved and authorized for use in smokeless
zones. Smokeless fuels can give over 30% more heat and last over 30% longer
than traditional house coals, whilst at the same time emitting up to 80% less
smoke and 25% less Carbon Dioxide, making it much kinder to the environment.
Smokeless fuels have an excellent heat output and a very long fire life, that
easily lasts through the night. Smokeless fuels are not difficult to light and
produce little ash.
Anthracite
Anthracite is a natural hard, shiny form of coal that is naturally
smokeless.Although anthracite can take longer to light, it can burn for
verylong periods producing a large amount of heat per volume It can be a
higher price-per-bag than other fuels,but anthracite can work out to be one of
the more cost effective fuels long term.
We recommend the small-nut size. Smaller anthracite nuts pack together tighter to create a more intense and long lasting fire bed which is popular with those looking for efficient heat. Anthracite is a high performance fuel which burns with a high heat and low flame, and leaves little ash behind. Suitable for burning in smoke control areas.
Restrictions
- DO NOT burn unseasoned wood in your appliance.
- DO NOT burn particle board, lacquered, painted or treated wood, plastics, rubber or liquid fuels.
- DO NOT use starter fluids or liquid fuels to start a fire
- DO NOT burn waste. This appliance should not be used as an incinerator.
Should the fire be used to burn any of the restricted materials mentioned above, it will not only invalidate your warranty but may damage the appliance or cause an unforeseen safety issue.
MAINTENANCE
Any maintenance of the appliance should only be carried out when the appliance is COLD.Daily maintenance should be limited to vacuum cleaning the appliance externally or brushing down with a soft brush. Never use spirits to clean the appliance as this may damage the paint surface.Regularly check the flue exit from the appliance to make sure there is no buildup of deposits that may restrict the exit of the flue gases.
Chimney sweeping
The chimney should be swept a minimum of once per year. This must be carried
out by a registered and competent person. If the appliance is used more
regularly, the chimney should be swept accordingly. Your appliance should also
be given a visual inspection everytime the chimney is swept.
These checks should include the rope seals,door handle, firebricks and baffle.
Any buildup of soot and ashes within the appliance should be removed,the cause
determined and rectified.
Fire bricks
The fire bricks are manufactured from vermiculite. Vermiculite is a non-
combustible fire resistant board, with excellent thermal insulation properties
and is safeto handle.As vermiculite isa porous material,it may overtime become
worn or damaged.Please handle with care,especiallywhen re-fuelling the
appliance.The insulation only needs replacing once it has deteriorated to an
extent that it is no longer protecting the body of the appliance from the
flames.Cracksin the vermiculite are normal and will not interfere with the
efficiency of the appliance.
The vermiculite insulation is not covered by the manufacturer’s warranty and
may need replacing over time.
Door glass
Blackening of the door glassis usually a result of burning damp wood (See
Problem solving – Blackened glass). The longer staining is left to build up on
the glass,the harder it becomes to clean it off. We recommend wiping the
glassafter each fire to prevent any buildup of deposits over time.
Thisis best done using a paper towel or newspaper to avoid scratching the
glass.Using a piece of newspaper to wipe the inside of the window glass before
lighting the appliance each time will alsohelp to prevent the gradual buildup
of deposits and make future cleaning much easier. For more stubborn stains, a
suitable stove glass cleaner will be available from your authorised F2
Firesdealer.
Glassis not covered by the manufacturer’s warranty and may need replacing if
it becomes damaged.
Surface
The high temperature paint finish should require no further treatment.
However,any damage or wear on small areasof the paint finish may be remedied
by using our high temperature aerosolpaints.We recommend Calfire Stove Bright®
paints,as other paints may not be suitable to such high temperatures and
substrates.Pleaseread the instructions on the aerosolcarefully before applying
and ensure the appliance is completely cold.
NEVER attempt any kind of maintenance when the stove is hot or warm. DO NOT attempt to clean the glass directly after use. Allow the stove to cool down fully before attempting any maintenance or cleaning.
OPERATIONAL ISSUES
Problem solving
Problem | Possible causes and solutions |
---|---|
Blackened glass |
- The wood is too damp. Only use wood that has been stored for at least 12months under cover and ideally with a moisture content of less than 20%.(See How to light and sustain a fire – Types of fuel)
- Insufficient intake of air from the air control. Open the air controls further to determine the correct balance for your fuel type.(See Operation – Lighting)
- Insufficient ventilation.The appliance is being run at too low a temperature.(See Operation – Lighting, Operational issues- Running temperature, Safety – Ventilation)
Smoke in the room when fueling|
- Poor chimney performance. Consult a chimney sweep or your installation engineer.
- Check the position of any fitted flue damper to make sure it is in the ‘open’ position.
- Never open the door when there are high flames on the fuel.Wait until the fuel is burning low before refuelling.
Uncontrollable combustion|
- If there is excessive chimney draught, you may need to fit a draught stabilizer in the flue pipe. Consult a chimney sweep or your installation engineer.
- Door not closed tightly, Adjust the set-screwing the handle. (See Installation and testing – Adjusting the handle)
- Damaged door seal. Consult your installation engineer or approved dealer about fitting a new rope seal.
Running temperature
Thermometers are available that attach to the flue pipe directly above the appliance and aid in running the appliance at the correct temperature. Your installation engineer should advise you of the correct settings after installation and testing is complete,by using this test procedure.
150°C-300°C
Perfect. The flue gasesshould be within this temperature range for the safest
and most efficient operation of your appliance.
Below 150°C
Too low. Thiswill cause the condensation of wood gasesand the buildup of tar
in the chimney. It can also dirty the glasswith excesssoot and resultsin the
inefficient burning of fuel.
Above 300°C
Too hot. Heat will be wasted up the chimney. Excessheat may damage the
appliance over time or ignite the existing accumulation of tar,which can
result in a chimney fire (SeeWarning below).
Overheating
Should the appliance be allowed to get too hot and overheat, you should close
the Primary and Secondary air controls fully, using the glove provided. Keep
the fire door closed and allow the fire to burn down and the temperature to
drop before allowing air back in gradually (See Above 300°C above).
Chimney Fire
In the event of a chimney fire, always dial 999 and ask for the Fire Service.
If safe to do so, fully close all air controls and keep the appliance door
closed. Move any combustibles away from the appliance and chimney .Check any
other rooms that the chimney passes through and move any combustibles away
from the chimney breast. Before using the appliance again after a chimney fire
,the chimney should be thoroughly cleaned and inspected by a qualified person
to ensure further damage has not occurred.
SPECIFICATIONS
Dimensions
- Width 430mm
- Height 570mm
- Depth 394mm
- Firebox width 3 0 0 m m
- Weight
- Appliance 75kg
- Packaging 5kg
- Combined 80kg
Operating parameters
-
Nominal heat output
5kW -
Ideal operating temperature range
150 – 300°C -
Efficiency 79.3% Wood, 80% Anthracite
Your stove is guaranteed for 2 yearsfrom date of purchase
See page 19 for extended warranty details.
This document must be completed by the installer; this constitutes a ‘Hearth Notice’ for purposes of the England and Wales Building Regulations 2000.
To be completed by the Installation Engineer:
Model
|
---|---
Serialnumber
|
Installer’sname
|
Registrationnumber
|
Date|
Who certifies that this installation is safe,has been demonstrated to the householder, conforms to current building regulations,has at least a 12Paflue draught measurement and has been through these instructions with the owner of the appliance.
Commissioned by (Signature) | Pascal Measurement |
---|---|
TO FIND A QUALIFIED INSTALLER,FUEL SUPPLIER or CHIMNEY SWEEP, CONTACT:
UK|TheSolidFuelAssociation,95HighStreet,ClayCross,Chesterfield,Derbyshire,S459DZ,England|Tel:0845-601-4406
|www.solidfuel.co.uk ROI|Irish Nationwide
Fireplace Organisation, P.O. Box 11563,Finglas,Dublin11,CountyDublin,Ireland
|Tel:086-236-6553 |www.fireplace.ie
Installer notes
Warranty
If you have purchased your stove from a F2 Stoves registered retailer, then
your stove will carry a 2 year warranty as standard. The 2 year warranty can
be further extended to a total warranty period of 5 years by registering your
F2 Stove within one month of the later of the purchase date or installation
date. Accordingly, the start date for the warranty period is the date of
purchase. During the registration process, the Registered Retailer details
will be required for your Extended Warranty to be activated. Any product
purchased outside of our registered Retailer Network will carry a standard 12
month, non-extendable warranty. It is a condition of the Extended Warranty
that the installation complies with the relevant Building Regulations and is
carried out by a suitably trained and qualified individual (HETAS in the UK or
equivalent in other countries) with the certificate of installation and proof
of purchase supplied.
Parts classed as consumable items subject to wear or in contact with high
temperatures, glass, rope seals, firebricks, grate and baffles are excluded
from the warranty. Cracks to cast iron parts caused by aggressive and high
temperatures due to over firing or the use of fuels not specified in these
instrucons are not covered by the stoves warranty.
Technical support
UK Distributor
Eurostove Ltd
Unit H1
Mendip Industrial Estate Rooksbridge
Somerset
BS26 2UG
Tel: +44(0)1934 750500 Fax: +44(0)1173 156207
technical@eurostove.co.uk
www.eurostove.co.uk
F2 Fires Limited UK Tel: +44(0)1254205739 | Fax:+44(0)1254790878 info@f2fires.co.uk | www.f2fires.co.uk
References
- content.As
- Eurostove
- Paul Agnew Designs
- Fireplace.ie is for sale | www.premiumdomains.ie
- Welcome to GOV.UK
- Solid Fuel Association - Advice for consumers & professionals
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>