CONTROLbyWEB X-422 Davis Weather Suite Controller User Guide
- June 3, 2024
- CONTROLbyWEB
Table of Contents
CONTROLbyWEB X-422 Davis Weather Suite Controller
Remove the Davis Board
- Install the Davis Instruments 1Ss. Ensure that all cables are routed to the ISS transmitter compartment.
- Install a grounded cable to the base of the weather station structure.
- Remove the four mounting screws that secure the ISS Transmitter Board, and remove the cover and board.
- Keep the screws and cover for later use.
Install the X-422
- Install the X-422 board (Ethernet port located towards the top) and cover with the four mounting screws.
- Insert Ethernet cable and/or power supply cable through the access port.
- Insert and connect each of the sensor cables to their respective modular connector.
- Install optional auxillary/barometric pressure sensors inside the enclosure and attach the leads to the terminal connector.
- Connect the Ethernet cable to a grounded surge protector and install a grounded wire to the negative voltage input (Vin-) terminal connector. See reverse side for required grounding instructions.
Accessing the Setup Pages
- Connect the module to power using POE and/or 9-28VDC and connect to a network.
- Set up the computer on the same network as the module. Io do this, set the IP address of the computer to 192.168.1.50 with a netmask of 255.255.255.0
- Configure the module using a web browser by typing the following into the address bar of a web browser: http://192.168.1.2/setup.html
- Log in to the setup pages using the default username: admin and default password: web relay (alllower case).
- Set the permanent IP address in the Network tab.
- Restart the module (remove power, re-apply power). After restarting the module, set the computer back to its original settings and access the module at its new IP address.
FACTORY DEFAULT SETTINGS
- IP Address: 192.168.1.2
- Subnet Mask: 255.255.255.0
- Weather Monitor Web Address: http://192.168.1.2
- Setup Web Address: http://192.168.1.2/setup.html
- Setup Username: admin
- Setup Password: webrelay (alllower case)
- Weather Monitor Password: (Optional)
How To Safely Ground the X-422
- Ensure that your weather station structure is properly connected to earth ground. Follow all local codes and work with licensed professionals.
- Inside the ISS Transmitter Compartment, connect the X-422 negative voltage input (Vin-) terminal connector to ground.
- Mount an Ethernet surge protector with an appropriate outdoor rated housing to the weather station mount, as close as possible to the ISS Transmitter Compartment.
- Connect the Ethernet surge protector to ground. Note: failure to use or properly ground the surge protector will void the warranty.
- Connect an Ethernet cable from the X-422 to the Ethernet surge protector.
- Connect an Ethernet cable from the network or POE switch to the Ethernet surge protector.
- If using shielded network cable, connect only one end of the shield to ground.
Model and mount structure shown may not be representative of your exact weather station.