INVIXIUM Titan Inguide 20jul21-Digital User Guide

June 3, 2024
INVIXIUM

INVIXIUM LOGO Titan Inguide 20jul21-Digital
User Guide
INVIXIUM Titan Inguide 20jul21-Digital

Invixium Customer Portal

INVIXIUM Titan Inguide 20jul21-Digital - Invixium Customer
Portal

Stay up to date with:

▪ Latest Updates
▪ Best Practices
▪ Datasheets
▪ Installation Guides
▪ Feature Description Documents| ▪ Videos
▪ FAQs
▪ Tutorials
▪ And more…
---|---

Visit https://www.invixium.com/support/

In the Box

INVIXIUM Titan Inguide 20jul21-Digital - In the Box

Getting Started

INVIXIUM Titan Inguide 20jul21-Digital - FIG1

  1. Remove the Mounting Plate, Wired Back Cover and screws from the IXM INSTALL KIT.

  2. Install the Mounting Plate at the desired location.
    Invixium recommends 115 cms from the floor to the bottom of the device.

  3. Make the necessary connections to the Wired Back Cover (refer to Get Wired Pages).

  4. Unscrew and remove the Temporary Back Cover from the IXM device and connect the Wired Back Cover using the same screws.

  5. Hang your IXM device on the Mounting Plate and secure it on the bottom with the screw provided.

Get Wired Glossary

ACP| Access Control Panel| SGND| Signal Ground| INVIXIUM
Titan Inguide 20jul21-Digital - Top Connector
---|---|---|---|---
COM| Common| SPI| Specific Purpose Input
DAC| Door Access Control| SPO| Specific Purpose Output
EGND| Door Strike Power| T| Termination
DSP| Earth Ground| TX| Transmitter
ETH| Ethernet| USB| Universal Serial Bus
GND| Ground| VBUS| USB Supply
NC| Normally Closed| VIN-| Power Ground
NO| Normally Open| VIN+| Power (12VDC)
RLY| Relay| WDATA| Wiegand Data
RX| Receiver| WGND| Wiegand Ground

Get Wired Top Connector

Wire Color Wire Label Pin(s)
Green/Red RESERVED 1
Orange/White RS232_RX 2
Green/Red RESERVED 3
Purple/White RS232_TX 4
Green/Yellow EGND 5
Black/Red SGND 6
Blue/Red RS485_T 7
Blue RS485_D+ 8
Green/Red RESERVED 9
Blue/Black RS485_D- 10
White/Red RLY_NC 11
Green/White WDATA_IN0 12
Grey RLY_COM 13
White/Black WDATA_IN1 14
Grey/Red RLY_NO 15
Green WDATA_OUT0 16
Red V_INPUT+ 17
White WDATA_OUT1 18
Black V_INPUT- 19
Black/Green WGND 20
Green/Red RESERVED 21
Green/Red RESERVED 22

RJ 45
Receptacle| TCP/IP|         23-30

Get Wired Bottom Connector

Wire Color Wire Label Pin(s)
Purple DAC_SUPPLY 1
Orange/Yellow SPO1 2
Green/Red RESERVED 3
Yellow/Green SPO2 4
Green/Red RESERVED 5
Green/Orange SPO3 6
Brown ACP_LED1 7
Black/Orange SPO_GND 8
Yellow ACP_LED2 9
Yellow/Cyan SPI1 10
Black/Yellow ACP_LED_GND 11
Cyan/Brown SPI2 12
White/Purple DAC_IN1 13
Brown/Yellow SPI3 14
Purple/Yellow DAC_IN2 15
Black/Cyan SPI_GND 16
Blue/White DAC_IN3 17
Orange DAC_OUT 18
Black/White DAC_IN_GND 19
Green/Red RESERVED 20
Green/Red RESERVED 21
Green/Red RESERVED 22
Red/White USB0_VBUS 23
Red/Grey USB1_VBUS 24
White/Black USB0_D- 25
White/Grey USB1_D- 26
Green/Black USB0_D+ 27
Green/Grey USB1_D+ 28
Black/Red USB0_GND 29
Black/Red USB1_GND 30

Earth Ground

For protection against Electrostatic Discharge, Invixium recommends the use of a ground connection between each IXM device to a high quality Earth Ground available at the install site.
Connect to Earth Ground in the following way:

  1. Connect the green and yellow earthing wire from the wired back cover (top connector PIN 5) to the building earthing.
  2. Connect the open end of earth ground wire provided in the Install Kit Box to the building earthing as well.
  3. Screw the lug end of the earth ground wire to the metal mounting plate.

Ensure all Earth Ground connections are made to each device prior to turning on the power.

HDMI Output

TITAN’s wired back cover is equipped with an HDMI Out Port that can be used for real time Video Surveillance for standalone installations. When the HDMI out is connected to a monitor via an HDMI cable (sold separately), the monitor screen will show the user the TITAN Field of View when in surveillance mode.
For security purposes, the HDMI cable can be connected to a monitor behind the door i.e. on the inside, to see what is happening on the outside.

INVIXIUM Titan Inguide 20jul21-Digital - FIG6

Power, Ethernet and Wi-Fi

Ensure that a regulated, filtered and dedicated power source provides a minimum of 3A @ 12 VDC per device, when using an external power supply. PoE+ connectivity is also available on all TITAN models.
When using PoE+, an IEEE 802.3at compliant Active Midspan Injector is required (sold separately). Refer to table for Invixium recommended PoE Injector specs. Full PoE deployments should include a centralized PoE PSE.
For Ethernet communication, a specific range of allowable IP addresses can be set for improved security.
For Wi-Fi communication on the TITAN, standard 802.11ac protocol is supported. DHCP is enabled as a factory default.
WEP, WPA and WPA2 encryption options are available.
INVIXIUM recommends the use of battery back up or a UPS with built-in surge protection.
WARNING: Product Warranty is void if improper power (under or over) is supplied to the device.

INVIXIUM recommended PoE+ Injector Specs

Input  Voltage 100-240 VAC, 50-60 Hz
 Input Current 0.75 A
Output Voltage 40-56 VDC
Output Current 0.625 A
Power 30 Watts

RS-485 Configuration

For RS-485 networks, ensure that IXM devices are wired in a daisy chain configuration, up to a maximum of 31 devices. At a baud rate of 9600 bps, make certain that the maximum cable length is not longer than 1200 m (4000 ft).

INVIXIUM Titan Inguide 20jul21-Digital - FIG8

R = 120 ohms for Standard RS-485 Cabling
R = 100 ohms for CAT5/6 Cabling

Top Connecter RS-485

SGND| -6|
---|---|---
RS-485+| -8
RS-485-| -10

Serial Communication and USB

For Serial Communication, IXM devices are also equipped with RS-232 and USB capabilities. Refer to Get Wired Bottom Connector page for RS-232 connections.
The USB port can be used to connect a Flash Drive via Micro USB OTG cable and perform functions like upgrading firmware, downloading transaction logs and configuration files.
The USB port can also be used to connect to a PC running IXM WEB via Micro USB cable.

INVIXIUM Titan Inguide 20jul21-Digital - FIG10

Wiegand

IXM devices have the option to use the Standard 26-bit Wiegand format or a Custom Wiegand format (up to 512 bits) to suit any Access Control System.
All IXM devices are set to Standard 26-bit format as a factory default.INVIXIUM Titan Inguide 20jul21-Digital - FIG11

Access Control Panel Connections

INVIXIUM Titan Inguide 20jul21-Digital - FIG12

ACP_LED signals can be used if available on the Access Control Panel.
IXM devices support up to 2 wires + GND for LED status.

Top Connector Wiegand

WDATA_OUT0 (16)
WDATA_OUT1 (18)
WGND (20)

Bottom Connector LED

ACP_LED1 (7)
ACP_LED2 (9)
ACP_LED_GND (11)

Door Access Control Connections (Electric Lock)

INVIXIUM Titan Inguide 20jul21-Digital - FIG15

Max Relay rating = 2A @ 24VDC
NOTE: A separate power supply is required for the door strike

Top Connector DAC

RLY_COM (13)
RLY_NO (15)

Bottom Connector DAC

DAC_IN1 (13)
DAC_IN2 (15)
DAC_OUT (18)

Door Access Control Connections (Magnetic Lock)

INVIXIUM Titan Inguide 20jul21-Digital - fig31

Max Relay rating = 2A @ 24VDC
NOTE: A separate power supply is required for the door strike

Top Connector DAC

RLY_NC (11)
RLY_COM (13)

Bottom Connector DAC

DAC_IN1 (13)
DAC_IN2 (15)
DAC_OUT (18)

Door Access Control Connections (Device Powers Door Strike)

INVIXIUM Titan Inguide 20jul21-Digital - FIG18

Max Relay rating = 2A @ 24VDC
Device can supply 500mA@12V or 250mA@24V
Top Connector DAC

RLY_COM (13)
RLY_NO (15)

Bottom Connector DAC

DAC_SUPPLY (1)
DAC_IN1 (13)
DAC_IN2 (15)
DAC_OUT (18)

Face Enrollment Best Practices

Invixium recommends standing at a distance of 2 to 3 feet from the device when enrolling a face.
Make sure your entire face is within the frame corners, which will turn green upon correct positioning.
The user should look straight at the camera when enrolling their face. Avoid looking in other directions or turning your head during enrollment.

INVIXIUM Titan Inguide 20jul21-Digital - FIG21

Fingerprint Enrollment Best Practices

Invixium recommends using the index and middle fingers for enrollment.
Make sure your finger is flat and centered on the sensor scanning area.
The finger should not be at an angle and should be straight when placing on the sensor.
Ensure that the finger is not too dry or too wet. Moisten your  finger during enrollment ifrequired.INVIXIUM Titan Inguide 20jul21-Digital -
FIG22

Finger Vein Enrollment Best Practices

Invixium recommends using the index and middle fingers for enrollment.
Make sure your finger tip is resting on the finger guide at the back of the sensor cavity.
The finger should be completely straight for the best finger vein scan.
Ensure that the finger is not turned or rotated in any direction.INVIXIUM
Titan Inguide 20jul21-Digital - FIG23

Finger Placement Best Practices

  1. Proper finger placement is crucial for good enrollment score and faster authentication.
  2. Place your finger straight on the sensor as shown below, while covering the finerprint sensor with the top third of your finger as shown on the Fingerprint Enrollment Best Practices page.
  3. For the finger vein sensor, place your finger straight so that the tip of your finger is resting on the guide at the far end of the sensor cavity as shown on the Finger Vein Best Practices page.INVIXIUM Titan Inguide 20jul21-Digital - FIG24

Card Placement

  1. The location of the card reader on the IXM TITAN is different than the other models.
  2. For IXM TITAN, the card reader is placed behind the emblem at the bottom part of the LCD.
  3. See below for the correct card placement while using the IXM TITAN.INVIXIUM Titan Inguide 20jul21-Digital - FIG25

Software Installation

  1. Go to www.invixium.com >> IXM WEB >> Get IXM WEB.
  2. Follow the instructions on the screen. Enter your details and click submit. You will then be sent an email with the latest IXM WEB package.
  3. Extract the compressed file and run IXM WEB.exe. Invixium recommends selecting Install for easier installation.
  4. When installation is complete, click Exit. The IXM WEB icon will now be on your desktop.
  5. Use the IXM WEB icon to run IXM WEB in your default web browser.
  6. Contact support@invixium.com in case of any issues.

INGUIDE

This is a Quick Start Guide. For a detailed guide please refer the Invixium Installation Guide.
For technical or customer support issues, please contact your Local Authorized Reseller first.
Visit the Customer Portal for more Invixium resources at www.invixium.com/support

Contact Invixium Support at:
support@invixium.com
+1 844 INVIXIUM (468 4948)
invixium_support

INVIXIUM LOGO

Enjoy the Experience.
Some features may vary based on device models.
Copyright © 2021, INVIXIUM. All rights reserved.
invixium.com
© 2019 Google Inc. All rights reserved. Chrome ™ browser is a trademark of Google Inc.
Firefox logo ® is a registered trademark of the Mozilla Foundation.
Windows® , Internet Explorer® and Edge® are trademarks of the Microsoft group of companies.
Safari® is a trademark of Apple Inc.
P/N XAD-00E-255-01G

Documents / Resources

| INVIXIUM Titan Inguide 20jul21-Digital [pdf] User Guide
Titan Inguide 20jul21-Digital
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals