KEISER 1133XX Leg Extension Pro User Manual

June 3, 2024
KEISER

KEISER 1133XX Leg Extension Pro

KEISER-1133XX-Leg-Extension-Pro-product

Keiser, the Keiser logo, and other trademarks associated with Keiser products referred to in this publication are trademarks of Keiser Corporation. © 2020 Keiser Corporation. All rights reserved. Distribution and copying of this document, use and communication of its contents is not permitted without written authorization from Keiser Corporation. The content of this document is furnished for informational use only, may be subject to change without notice, and should not be construed as a commitment by Keiser Corporation. Every effort has been made to ensure that the information in this manual is accurate. Keiser Corporation is not responsible for printing or clerical errors.

GENERAL INFORMATION

INTRODUCTION
Congratulations on the purchase of your new Keiser Air300 Leg Extension Pro and welcome to the Keiser family. Keiser’s Dynamic Variable Resistance safely builds strength at any speed, which is key to building maximum power. For your safety, and to ensure the best experience and maximum gains, it is critical that you read and understand this manual before you begin using the Air300 Leg Extension Pro. If you have any questions regarding the operation of the Air300 Leg Extension Pro after reading this manual, our Keiser Customer Support team will be happy to assist by telephone at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at [email protected]. Yours in Health, Keiser Corporation

REGISTER YOUR PURCHASE
Register your Air300 Leg Extension Pro to stay informed of safety notifications and for faster, more accurate warranty service. Scan the QR Code to the right to access the interactive online warranty registration form or visit: https://www.keiser.com/forms/warrantyregistration

SERIAL NUMBER INFORMATION
Please take a moment at this time to record the serial number in the space provided below. Serial No.:

Serial Number Information

A| Manufacturer name, logo, and address
B| Country of manufacture
C| Patent information notification
D| CE mark
E| TÜV SÜD Mark
F| Quality management ISO standard
G| Maximum User Weight Limit
H| Directive and standards compliance
I| European Authorized Representative
J| Serial number and date of manufacture
K| Model number and product description
L| WEEE Directive Mark

Serial Number Location on the Air300 Leg Extension Pro

KEISER-1133XX-Leg-Extension-Pro-fig-2

IMPORTANT SAFETY INFORMATION

It is the sole responsibility of the purchaser of Keiser Corporation equipment to instruct all individuals, whether they are the enduser or supervising personnel, on proper usage of the equipment.  Keiser Corporation recommends that all users of its equipment be informed of the following information before use.

  1. Read these instructions.
  2. Heed all warnings.
  3. Follow these instructions.
  4. Consult your physician before beginning any exercise program.
  5. The Air300 Leg Extension Pro is intended for use in training areas of organizations where access and control are specifically regulated by a person responsible for determining the suitability of use and maintenance.
  6. Maximum user weight limit: 441 lbs (200 kg).
  7. Use the Air300 Leg Extension Pro indoor in a climate-controlled environment only. Keep away from areas of extreme humidity.
  8. The use of this Air300 Leg Extension Pro for any purpose not explicitly specified by the manufacturer in this manual is prohibited.
  9. Wear proper exercise clothing and shoes for exercise. Avoid wearing loose clothing that might catch on any moving parts. Tie long hair back and up away from the Seat Back adjustment mechanism.
  10. The Air300 Leg Extension Pro is not a toy. Children shall not play with the Air300 Leg Extension Pro. Children under 14 years old should not use the Air300 Leg Extension Pro. Keep children and pets clear from the Air300 Leg Extension Pro at all times, especially while in use. Cleaning and user maintenance shall not be performed by children.
  11. The Air300 Leg Extension Pro can be used by children age 14 years and above. Persons with mental disabilities, reduced physical, mental, or sensory capabilities, or lack of experience or knowledge should not use the Air300 Leg Extension Pro without constant supervision by a spotter/supervisor.
  12. Proper warm-up required to help prevent injury. This Air300 Leg Extension Pro should only be used with proper instructions. Always maintain good form and control during exercise. If you feel pain or are unable to maintain good form, stop immediately. Failure to follow these instructions could result in injury.
  13. Always maintain control of the Leg Cushions (Exercise Arms) during exercise. The sudden release of the Exercise Arms during exercise will cause the Exercise Arms to recoil uncontrollably and could result in serious injury or property damage. Bring the Exercise Arms to the start position in a controlled manner to safely exit the equipment. If at any time you are not able to control your legs during exercise, push the left (“-”)Thumb Button to reduce the resistance.
  14. Never perform Power Test without a proper warm-up. This high resistance/high-speed test should only be performed with proper instructions (see page 14 “Power Test” for complete instruction). Always maintain good form and control during the test. If you feel pain or are unable to maintain good form, stop immediately. Failure to follow these instructions could result in injury.
  15. Never make adjustments to the machine during exercise as this may cause muscle strain. Always return the Exercise Arm to the start position before making any adjustments to help prevent injury.
  16. The highest level of safety can only be ensured if the equipment is regularly inspected for damage and wear. Always check the equipment before use for proper function and any damaged, worn, or broken parts. Immediately replace damaged, worn, or broken parts. Do not use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser-certified technician.
  17. Use only replacement parts supplied/recommended by Keiser Corporation. Attempting to repair or replace any damaged, worn, or broken parts on your own is not recommended. A Keiser-certified technician should be consulted.
  18. The use of any exercise equipment, including, without limitation, Keiser’s strength training equipment in which resistance can be changed at any time during the repetition, without proper instruction and supervision violates the terms of the agreement for the purchase of such products. The ability to add resistance anytime during a repetition, including, without limitation, the ability to do a heavy negative may be dangerous, especially for anyone that does not recognize or respect the potential danger.
  19. Users, agents, and/or anyone directing the use of the Air300 Leg Extension Pro shall determine the suitability of the Air300 Leg Extension Pro for its intended use, and said parties are specifically put on notice that they shall assume all risk and liability in connection herewith.
  20. If you do not understand these instructions or have doubts about the safety of the installation, assembly, or use of this product, contact Keiser Customer Support:

1 559 256 8000
[email protected]
keiser.com/support
Telephone and Live Chat Monday—Friday 9 am to 5 pm PST

CONVENTIONS USED
This Operation Manual contains the following marks:

  • WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
  • CAUTION : Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
  • IMPORTANT : Indicates information considered critical, but not hazard-related.
SAFETY AND NOTIFICATION LABELS

KEISER-1133XX-Leg-Extension-Pro-fig-3

TECHNICAL SPECIFICATIONS

EQUIPMENT SPECIFICATIONS
See Figure 2 for Air300 Leg Extension Pro dimensions and weight.

  • Resistance Range 0 – 236 lbs (0 – 107 kg), change resistance in 1 lb/kg increments
  • Independent Exercise Arms
  • 135° Range of Motion
  • Adjustable Seat Back
  • Maximum user weight limit 441 lbs (200 kg)

KEISER-1133XX-Leg-Extension-Pro-fig-5

TECHNICAL DATA
AIR STORAGE TANKS The equipment contains two air storage tanks (air accumulator) with the following operating parameters:

  • Maximum working pressure : 125 psi (8.6 bar)
  • Maximum working temperature : 104ºF (40ºC)
  • Minimum working temperature : 32ºF (0ºC)
  • Maximum vessel capacity : 72 in3 (1.18 L) per tank

POWER

  • 1.5V D Alkaline Batteries (quantity 2, Keiser PN 966500)
  • 3V CR2032 Lithium Coin Cell Battery (quantity 1)

Permanently attached, not serviceable. Contact Keiser Customer Support for service.

KEISER CHIP SYSTEM
The eChip insertion slot receives the Keiser eChip (electronic memory chip) for data transfer and storage

INSTALLATION AND PLACEMENT

No assembly required. Place the Air300 Leg Extension Pro on a flat, level surface. Make sure the base of the frame makes full contact with the floor. If gaps are present, relocate the equipment to an even surface. CONNECT THE EQUIPMENT TO THE KEISER AIR SYSTEM

WARNING : Never connect equipment to an air source capable of exceeding 120 psi / 8.27 bar. Over pressurizing Keiser pneumatic equipment may cause tubing to burst, breakage of equipment, abnormal operation, or serious injury. Use only clean, dry, regulated compressed air at the rated pressure range of 100–120 psi / 6.89–8.27 bar.

  1. Plug the Compressor into the appropriate power source to power the Compressor ON (allow the Compressor to build up to a minimum of 100 psi / 6.89 bar; Keiser Compressor and Keiser Air System not included, sold separately).
  2. Connect the 1/4-inch Quick Disconnect (QD) from the equipment into the Keiser Air Supply

TRAINING SPACE
Figure 4. Training Space for the Air300 Leg Extension Pro The equipment footprint is 40 inches x 39 inches (1,016 mm x 991 mm). The minimum recommended free space around the equipment is 24 inches (610 mm) for the front and sides.

KEISER-1133XX-Leg-Extension-Pro-fig-7

OPERATION

EQUIPMENT OVERVIEW

KEISER-1133XX-Leg-Extension-Pro-fig-8

  1. Power Display
  2. Exercise Arms
  3. Leg Cushions
  4. Anti-Slip Steps
  5. Cylinders
  6. Belts
  7. Quick Disconnect (QD) with Tube
  8. Air Tanks
  9. Processor Box
  10. Seat Lever
  11. Increase/Decrease (+/) Thumb Buttons
  12. eChip
  13. Seat Back
  14. Seat
  15. Instruction Placard (not shown)

POWER DISPLAY

KEISER-1133XX-Leg-Extension-Pro-fig-9

When using the eChip, ensure that it is fully inserted into the slot as shown.

CAUTION
Rate monitoring systems may be inaccurate. Over exercising may result in serious injury or death. If you feel faint stop exercising immediately. “Peak Power” not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters Use of the exercise Target program requires medical supervision and compliance with exercise testing guidelines.

DISPLAY FEATURES
  1. LINE 1 – RESISTANCE
    The Resistance window displays the current resistance or OFF. Adjust the resistance using the (+/-) Thumb Buttons located on either side of the Seat. When the window displays OFF, the machine enters a low power consumption sleep mode to increase battery life. Normal operation may be resumed by pressing either Thumb Button or by inserting the eChip. If this window displays the low battery signal (“Lo-bA”), the batteries are getting weak and should be replaced soon (D batteries, quantity 2; refer to page 16 “Battery Replacement” for complete instructions).

  2. LINE 2 – SET OR REPETITIONS
    This window displays the current repetition count except immediately after an eChip is first inserted, in which case it displays the current set. The set count may range from 1 to 9 and is signaled by the appearance of three horizontal bars in the left digit. The number of sets is defined as the number of sets of exercises performed in a four-hour period. Once four hours have passed, the machine assumes that the user is returning for a new visit. The repetition count may range from 0 to 99. The repetition count may be reset by momentarily pressing both increase and decrease (+/-)Thumb Buttons simultaneously. In Power Test mode, the window will display the repetition count per test section (refer to page 14 “Power Test” for complete instructions).

  3. LINE 3- TARGET REPS
    The Target Reps window displays the number of repetitions performed on the corresponding set of the previous visit, if that set was a normal workout set and an eChip is inserted. If the corresponding set of the previous visit was a Power Test, the display will show “Pr.” When in Power Test mode, the window will display “P1” during the low resistance test set and “P2” during the high resistance test set (refer to page 14 “Power Test” for complete instructions).

  4. LINE 4 – CURRENT POWER / PERCENT OF PEAK POWER
    The Current Power window can display 4 different values. During an exercise set, it displays the percent of peak power achieved for the most recent repetition. At the end of a Power Test, this window displays the resistance to use to achieve maximum power. When an eChip is inserted and the previous corresponding set was a normal workout set, it displays the resistance used for that set. When an eChip is inserted, and the previous corresponding set was a Power Test, it displays the resistance to use to achieve maximum power. When the calculated resistance to achieve maximum power is being displayed, it flashes. In summary, during an exercise set, this window displays the power for the current rep, at the end of a Power Test it is the resistance to use for training at maximum power; when an eChip is inserted it is the resistance to set into the window above before exercising.

  5. LINE 5 – PEAK POWER
    The Peak Power window displays the highest power that has occurred during this workout or since the data was last reset.

  6. LINE 6 – MACHINE ADJUSTMENT
    When using the eChip, the Seat position (fore or aft position, 16 settings) can be tracked and recorded. Press the arrows located directly above/below each window to input settings.
    NOTE : The adjustment may only be changed immediately after the eChip is inserted and before the third repetition has occurred. Once three repetitions are performed, the machine adjustments cannot be changed until the eChip has been removed and reinserted. The machine adjustment applies to a machine and cannot be changed from set to set.

  7. LINE 7 – eCHIP READER
    The eChip Reader, located at the bottom right of the Power Display, receives and reads your eChip data.

  8. LINE 8 – eCHIP
    The eChip collects workout data and can store up to 24 separate equipment models (up to 4 equipment position settings per model) and up to 240 separate workout sets across Keiser Air and Infinity Series. Designed as an electronic replacement for the hand-written exercise card, the eChip enables recall and set-up of the exercise equipment upon the next workout. The Keiser eChip software allows saved eChip data to be viewed, stored, and exported (.csv file format) for analysis.
    NOTE: Three user eChips (red color) come standard with your Air300 Leg Extension Pro. The Keiser USB Power Kit (a USB adapter to transfer data from your eChip to your computer and Time Set eChips to set the time zone/time on your Air300 Leg Extension Pro) is available. For parts order, contact Keiser Customer Support (see back cover for contact information). Keiser eChip software system requirements, download, and user manual available at keiser.com/support (search: eChip).

PROPER OPERATION CHECK
Check equipment condition and function before every workout:

  • A Thumb Buttons and Display — press Thumb Buttons to check for proper “+ / -” operation and the Display powers on*.
  • B. Upholstery — Seat and Seat Back have no excessive wear and are free of rips or tears.
  • C. Seat Lever — engages and functions properly.
  • D. Air Leaks — No air leaks audible in the system.
  • E. Stability — equipment is level to a solid, flat surface.
  • F. Exercise Arms — Move freely; no loose parts in the linkage system, no excessive wear on any rubber stops.

KEISER-1133XX-Leg-Extension-Pro-fig-10

Immediately replace damaged, worn, or broken parts. Do not use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser- certified technician.

  • “Lo-bA” = Batteries are low, replace immediately. If batteries are dead (depleted), the Power Display remains blank (see Battery Replacement procedure, page 16).

HOW TO USE THE AIR300 LEG EXTENSION PRO

  1. Pull the Seat Back forward, or lift the lever to move backward, so your knees align with the machine pivot point.
  2. Grasp the Handgrips and adjust the resistance with the Thumb Buttons.

KEISER-1133XX-Leg-Extension-Pro-fig-11

How to Use the Air300 Leg Extension Pro

CAUTION

  • Consult your physician before beginning any exercise program.
  • This equipment should only be used with proper instructions.
  • Proper warm-up required to help prevent serious injury.
  • Always maintain good form and control during exercise.
  • If you feel pain, faintness, or are unable to maintain good form, stop immediately.
  • Use caution when increasing/decreasing resistance during exercise.
  • Never make adjustments to the machine during exercise. Failure to do so could result in serious injury.

CONCENTRIC PHASE (UPWARD MOVEMENT)

  • Extend your legs at the knee.
  • Move your feet up and at the same time to full knee extension; move legs at the same level.
  • Keep your back supported by the Seat Back during movement.

ECCENTRIC PHASE (DOWNWARD MOVEMENT)

  • Return the Exercise Arms to the start position in a smooth, controlled manner.
  • Slower speed during downward movement is recommended.
  • Maintain control of the load; keep the Exercise Arms off the stops throughout the exercise.

BREATHING

  • Exhale during the concentric phase (upward movement).
  • Inhale during the eccentric phase (downward movement).

TRAINING TIPS

  • Maintain the natural curvature of your spine.
  • Avoid rocking your body to create momentum when moving heavy loads.
  • Hold the Handgrips for stability during movement.
  • To perform exercise one leg at a time, keep your resting foot under the other Leg Cushion for added stability during movement.
POWER TEST

CAUTION

  • Test should only be performed with proper instruction.
  • Never perform Power Test without proper warm-up.
  • Always maintain good form and control throughout test.
  • Rate monitoring systems may be inaccurate. Over exercising may result in serious injury or death. If you feel faint stop exercising immediately.
  • “Current Power,” “Peak Power,” and “Percent of Peak Power” are not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
  • The use of any exercise program requires medical consultation and compliance with exercise testing guidelines.

TEST PROTOCOL — The Power Test (KEISER Six-Rep Test) is used to determine the resistance at which you achieve MAXIMUM POWER. The test consists of two sets:

KEISER-1133XX-Leg-Extension-Pro-fig-13

Perform all repetitions at the highest possible speed at the given resistance; speed is essential in power output.

Note : The Power Test may be performed with or without an eChip. Follow the Power Test instructions below:

  1. START TEST : Press and hold both Thumb Buttons until “6 r” (Test Mode) displays in the RESISTANCE window, then release the Thumb Buttons. NOTE: TARGET REPS window displays “P1” (Power Test Set 1).

  2. SET RESISTANCE, LOW LEVEL Set the resistance to 10% of your maximum.

  3. POWER TEST, SET 1 (P1) Do one repetition at maximum speed. Pause 10 seconds. Repeat two more times.KEISER-1133XX-Leg-Extension-Pro-fig-14

  4. SET RESISTANCE, HIGH LEVEL Increase the resistance to a high level (80-90% of your maximum). NOTE: TARGET REPS window displays “P2” (Power Test Set 2).

  5. POWER TEST, SET 2 (P2) Do one repetition at maximum speed. Pause 10 seconds.
    Repeat 2 more times.

  6. TEST COMPLETE
    The flashing number is your Resistance setting for Maximum Power.KEISER-
1133XX-Leg-Extension-Pro-fig-15

TROUBLESHOOT : “Er” numbers 1 – 4 displayed in the CURRENT POWER window indicates not enough difference in resistance between the low and high sets. Try again with a greater difference in resistance between the low and high sets. To restart the Power Test, (a) reinsert eChip, if the eChip is being used, or (b) begin at Step 1 to repeat the procedure.

MAINTENANCE

CAUTION : SERVICE AND REPAIR SHALL ONLY BE PERFORMED BY KEISER-CERTIFIED TECHNICIANS. Failure to follow these instructions can result in serious injury.

PREVENTATIVE MAINTENANCE SCHEDULE

CAUTION : THE HIGHEST LEVEL OF EQUIPMENT SAFETY CAN ONLY BE ENSURED IF THE EQUIPMENT IS REGULARLY INSPECTED FOR DAMAGE AND WEAR. Immediately replace damaged, worn, or broken parts. Do not use the Air300 Leg Extension Pro until all repairs have been completed and tested by a Keiser-certified technician.

KEISER-1133XX-Leg-Extension-Pro-fig-20

IMPORTANT : Do not use household or industrial cleaners as they contain caustic chemicals that can destroy the paint finish and cause corrosion. Use only mild soap/detergent (neutral, non-caustic) to clean

BATTERY REPLACEMENT
Do not operate the equipment during battery replacement procedure. “Lo-bA” = Batteries are low, replace immediately.

NOTE : If batteries are dead (depleted), the Power Display remains blank. To replace the batteries, refer to Figure 10 and follow the instructions below (no tools required).

  1. Unscrew the Brass Nut on the Processor Box. Pull and remove the cover.
  2. Remove the 2 D batteries by carefully pulling out the Battery Sleeve (follow manufacturer’s recommendations for handling, maintaining, and disposing of batteries).
  3. Observe the correct polarity position (see +/- marking inside the battery compartment), insert the 2 new D batteries into the battery sleeve and install.
  4. Replace the Processor Box cover and screw the Brass Nut finger tight

When the batteries are replaced, the Power Display will run through a test sequence (you will see a series of numbers flashing). Once the test sequence stops and the Power Display shows “OFF,” the Air300 Leg Extension Pro is ready for use.

CAUTION
Do not dispose of batteries in a fire. The batteries may explode. Do not open or mutilate batteries. They contain an electrolyte which is toxic and  harmful to the skin and eyes Replace batteries with the same number and type of batteries as originally installed in the equipment. Recycle batteries in accordance with local recycling procedures.

ANNUAL MAINTENANCE
The following routine maintenance is recommended annually or at the time batteries are replaced

  1. Clean:
  2. Wipe any accumulated dust around the Frame and the Belt System, including the Air Tanks and Cylinders, using a clean shop cloth.
  3. Replace the Mufflers if discoloration is present.
  4. Tool required : 11/16 inch Wrench or Adjustable Wrench.
  5. Replace the Air Filter if element is dirty (element turns a bright pink or red color):
  6. Tools required : Small Needle Nose Pliers, Cutter Tool (to cut off flared end of tubes).
  7. Visual inspection of Air Lines and Communication Wires:
  8. Air Lines have no kinks, tears, or breaks; Communication Wires have no exposed wires or visible damage.
  9. Lubricate Cylinder Rods:
  10. Wipe the Cylinder Rods clean and coat lightly with clean, SAE 30 motor oil, or with a silicon-based spray.
  11. Visual inspection of Belts and Linkage:
  12. Belts are free of cracks, frayed edges, or otherwise excessive wear; bolts are tightened properly.
  13. Visual inspection of moving components:
  14. Seat Lever functions properly and the adjustment mechanism engages properly. Check Exercise Arms are fully functional; all externally visible nuts and bolts are tightened properly.

WARNING : HIGH-PRESSURE AIR. DISCONNECT THE EQUIPMENT FROM THE AIR SUPPLY AND RELEASE ALL THE AIR IN THE EQUIPMENT (“— ” THUMB BUTTON) BEFORE PERFORMING ROUTINE MAINTENANCE.

REGULATORY AND COMPLIANCE NOTICES

Standards| ISO/EN 20957-1 Accuracy Class A (High accuracy) and Usage Class S (Studio, commercial use); IEC/EN 60601-1 and IEC/EN 60601-1-2.
---|---
Marks|

SAFETY NOTIFICATIONS
  • Displayed watts testing parameters : “Current Power,” “Peak Power,” and “Percent of Peak Power” are not suitable for use in applications where the health and safety of a patient may be dependent on the accuracy of those parameters.
  • Clinical Settings Note : In clinical settings, patients may operate this equipment in accordance with this user manual and the instructions and guidance provided by the healthcare personnel responsible for supervising their treatment and care. However, patients shall not perform preventive maintenance, repairs or replace batteries on equipment installed in clinical facilities.

TYPE/DEGREE OF PROTECTION| CLASSIFICATION/IDENTIFICATION/WARNINGS| SYMBOL
---|---|---
The degree of protection against electric shock| Device is powered by two D cell alkaline batteries. Electrical safety evaluation conducted by TÜV SÜD per IEC/EN 60601-1 requirement.|
The degree of protection against the ingress of liquids| Not protected| N/A
The degree of safety in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide| Not suitable| N/A
The mode of operation| Continuous| N/A
Information regarding potential electromagnetic or other interference and advice regarding avoidance| The Air300 Leg Extension Pro use electromagnetic and RF energy only for its internal function. Therefore, its EMC and RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.| N/A
EMC Notices, Statement of Compliance| See Electromagnetic Compatibility (EMC) section, page 19.| N/A
ID of specified optional external power

supplies or battery chargers

| The Air300 Leg Extension Pro does not require an external power supply.| N/A
ID of any risks associated with the disposal of waste products, residues, including disposal of the equipment itself at the end of its useful life.| The Air300 Leg Extension Pro contains electronic circuit assemblies, 2 alkaline D cell batteries, and a sealed lithium coin cell battery that may require compliance with specific local disposal or recycling procedures.|

The specification of the environmental

conditions of transport and storage

| Use indoor in climate-controlled environment only. Keep away from areas of extreme humidity.

NOTICE: Equipment not tested at extreme high/low

temperatures.

| N/A

ELECTROMAGNETIC COMPATIBILITY (EMC)
EMC Notices — Statement of Compliance This product has been determined to be compliant with the applicable standards, regulations, and directives for the countries where the product is marketed. Compliance documentation, such as Declaration of Compliance for the product, are available upon request by contacting [email protected]. Please include the product, model number identifiers, and serial number and country that compliance information is needed in request. Korea

“This equipment is for home use and has acquired electromagnetic conformity registration, so it can be used not only in residential areas but also other areas.”

US FCC COMPLIANCE STATEMENT

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference  will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

DISPOSAL
This equipment contains electrical or electronic components, alkaline batteries, and a sealed lithium coin cell battery that must be disposed of properly to comply with the EU Directive on disposal of waste electrical and electronic equipment (EU WEEE Directive 2002/96/EC). Contact an appropriate waste disposal company upon the equipment’s end of service life. Disposal must be in accordance with respective national regulation. Wear parts: After being replaced, wear parts must be disposed of according to country-specific waste laws. If you have any questions about equipment disposal, please contact your local dealer or Keiser Customer Support (see back cover for contact information).

WARRANTY STATEMENT

View or print your Air300 Leg Extension Pro warranty online at keiser.com/support/warranty. If you have any questions about your warranty, please contact Keiser Customer Support at 1 559 256 8000 and via live chat at keiser.com/support (Monday—Friday, 9 am to 5 pm Pacific Time), or by email at [email protected]. Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in the country of installation, or direct from Keiser’s international division.

European Authorized Representative
KEISER EUROPE SP. Z O.O. ul. Starodworska 1 Gdańsk 80-137 Polska

UK Responsible Person (UKRP)
KEISER UK Ltd. Unit 3, Hampton Industrial Estate Hampton St., Tetbury Gloucestershire, GL8 8LD  United Kingdom

CUSTOMER SUPPORT
If you have any questions regarding the operation of the A300 Leg Extension Pro after reading this manual, contact Keiser Customer Support

KEISER CORPORATION
2470 S. Cherry Ave. Fresno, CA 93706

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KEISER User Manuals

Related Manuals