Thank you very much for purchasing our air conditioner.Please read this owner`s manual carefully before using your air conditioner.

INTRODUCTION
IMPORTANT SAFETY INSTRUCTION …………………………………………………………………1 ELECTRICAL REQUIREMENTS ………………………………………………………………………..2 PACKING LIST ………………………………………………………………………………………………3 INSTALLATION & ASSEMBLY INSTRUCTIONS ……………………………………………………..4 USING YOUR AIR CONDITIONER ……………………………………………………………………..8 OPERATING YOUR AIR CONDITIONER ………………………………………………………………10 CARE AND CLEANING …………………………………………………………………………………… 11 TROUBLESHOOTING …………………………………………………………………………………….12

1

8K/10K/12K/14K Cooling 8K Cooling & Heating

10K/12K/14K Cooling & Heating

2

IMAG E

PAP T

QUANTIT Y

Through-The-Wall Air Conditioner

1

or

Remote Control

1

Trim Frame 1 (Left&Right legs)

2

Trim Frame 2 (Top&Bottom legs)

2

Grille Aluminum

1

Dimensio n
1”x3/4”x14” 1”x3/8”x14” 1”x3/8”x25” 1”x1 1/2”x25” 1”x1 1/2”x14” 1”x1 1/2”x84” 3 3/4”x1 1/2” x4” 3/4”x1 1/2”x17”

Rear plastic net

1

1/2″ Long Hex-head Screw

4

Grounding wire with tooth washer

1

PAP T

QUANTIT Y

Seal sponge

2

Seal sponge

2

Seal sponge

3

Seal sponge

3

Seal sponge

2

Seal sponge

1

Seal cotton

4

Seal cotton

2

3

Universal Wall-Sleeve Dimensions
1. Identify the wall-sleeve brand for your preparing, from the below chart.

Brand
Frigidaire White-Westinghouse Carrier(52 Series) GE/Hotpoint/Amana Whirlpool Fedders/Emerson/Friedrich(WSE) Sears/Kenmore Carrier(51S Series) Emerson/Fedders Friedrich(USC)

Brand
15 1/4”
15 5/8” 16 1/2” 16 3/4” 16 7/8” 15 3/4” 15 1/2”

Wall-sleeve Dimensions
Brand

Brand

25 1/2”

16” 17 1/2” or 22”

26” 25 7/8”
27”
25 3/4”
26 3/4” 25 7/8”

16 7/8” 17 1/8” or 23” 16 3/4” or 193/4”
18 5/8”
15” 16 3/4”

NOTE ·All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear
grille that securely attached to the sleeve, or rear flange that serves as a stop for the air conditioner. ·For new or replacement installations, a Frigidaire Sleeve Kit (EA108T) is recommended.
CAUTION When installation is complete, replacement unit must have rearward slope as shown in Fig 1.
2. Remove old Air Conditioner from wall sleeve and prepare as followings: — Clean interior (Do not disturb seals). — Check the wall sleeve is securely fastened in wall before installing. Add more nails or screws if needed. — Repair painted surface if needed.
3. If the ground wire hole does not exist, drill a 3/16” pilot hole for the grounding screw through the left hand side of the sleeve, in a clear area about 3 inches max. back from the front edge as below. Pull the loose end of the ground wire out of the front of the sleeve and bend it away from the opening. This will be attached to the air conditioner once installed.

4. Install new unit into wall sleeve. 5. To attach ground wire to the new unit, remove the screw from the left side front. 6. Assemble and install the Trim Frame.
4

NOTE ·This units increased performance characteristics is the result of having two rear intakes. ·It is very important that these installation instructions are followed so your unit can operate at maximum
efficiency. ·If there is an existing sleeve and rear grille, please check whether the dimension is suitable or not, otherwise
replace them. Existing Frigidaire sleeves may have older single sided intake grilles,as pictured below · Remove t he existing grille ansdave the mount ing screws . · Pl acet he gr i l li encl uded wi t hyour newai r condi t i oner
t owar ds t hiens i de r eaorf t hes l eeve. ·At t ach t henew gr i l l bey al i gni ngt he f ourmount i ng hol es . · Re- in s er tt he s el f – t appi nsgcr ews i nt ot he nyl onr et ai n
2. Grille Removal Important: Single intake grille must be removed when used with dual intake TTW unit. Warning: When removing grille, protect from falling by securing with a leash. This can be fastened from cord or strapping looped through the grille and secured with a knot. Holding the grille by the leash with one hand the retaining screws can be removed and the grille can be brought inside through the front of the sleeve.
5

Direct Unit Mounting In cases where the dual intake grille cannot be mounted directly to the sleeve it is desirable to attach the grille to the back of the TTW unit to the hole predrilled in the unit. 1. Attach the 2 seals(1”x3/8”x14”), as Fig. 1.
2. Position the grille over the rear of the unit making sure that: a.The double set of screw holes are at the bottom. b.The intake fins on either side are pointed away from the unit. 3. Align the top of the grille with the top of the unit. The overhang on each side is equal. 4. If the unit has not been predrilled (some models),carefully drill 4-1/8” holes through the grille and into the side
flange of the unit approximately 1 1/2” to 2” fromthe top and bottom, as Fig 2 or 3. (Be careful not to break the copper pipe)
5. Install 4-#8 self-tapping screws to affix the grille to the unit. 6. Insert the unit into the sleeve. Grille to Sleeve Attachment In cases where the dual intake grille fits inside the sleeve and the grille flange overlaps the sleeve flange, direct attachment may be possible. IMPORTANT If the suitable grille is not used, it may lead to product damage and possible failure.
6

Seal Installation 1. 1”x3/8”x25” long seal in the center at the top of the sleeve. Remove the back paper and press into position. 2. 1”x3/8”x14” seals to the left and right sides of the sleeve. 3. Cut 1”x3/8”x25” long seals to 14” long each and attach to the vertical sections of the grille as shown. 4. 1/2”x3 1/2”x1 1/2” centering blocks one on each side wall. Place in center of side wall with the tapered end
facing the opening. 5. Gently slide unit into sleeve.
Ground Wire Installation 1. Install screw end of ground wire into inside of sleeve according to preparation instruction. 2. Before sliding unit all the way back remove second screw from left side of unit. 3. Remove plastic washer from screw. 4. Screw the other end of the ground wire into the unit as shown. Make sure the toothed washer is against the
cabinet. 5. Slide unit completely to the rear.
Non-Frigidaire Dual Intake Grille In case where the existing sleeve is a non- Frigidaire sleeve but is installed with a dual intake grille. The existing grille may be left in place. Make sure the outer 3 1/2” to 4 1/2” louvers are angled from the left and right sides of the sleeve toward the center, as Fig.

  1. This provides proper flow of outside air into the unit. From the installation kit, apply two 1”x3/4”x14” seals along the flat metal flange of the condenser, as Fig. 2.
    7

Insert the unit with the seal into the sleeve pushing it all the way to rear making sure the seals are against the rear grille. The seals are necessary to reduce recirculation of hot air into the intakes which would reduce system reduce system performance.
An option is to purchase 3/4” diamond cut aluminum grille and cut it to fit inside the sleeve. Secure it with screws. Attach the dual intake grill directly to the back of the unit. Slide the entire unit into the sleeve and seal with the stuffing seal supplied with the kit.
Trim Kit Installation Instructions 1. Install the 1”x1”x84” long stuffer seal between the wall sleeve and the unit. A flat-bladed screwdriver or putty
knife is needed. 2. Assemble the trim frame by inserting the top and bottom pieces into side pieces and snapping into place. 3. Pull the cord through the trim frame and slide the trim over the unit until flush with the wall.
Energy saving suggestion: In order to reach the maximum energy saving and comfortable, it is necessary to use an appropriately sized cover to provide additional insulation and air sealing when the unit is not in use during the off-using-season.
8

For Cooling model

1

2

AUTO SPEED

AUTO MODE

3

98 76 54

For Heating model

1

2

AUTO SPEED

HEAT

AUTO MODE

3

98 76 54

1. Digital Display: Without timer setting,the operation mode is Cooling,Dry, Fan and Auto,and the set temperature will be displayed.

Time will be displayed under timer setting.

and Button: Use these buttons on the

control panel and remote to increase or decrease

the Set Temperature or Timer.

Temperature range: 61 ~88 or 16 ~31 .

3. Power Button: Turn the air conditioner on and off.

4. Mode Button: Press the mode button to cycle through the various modes: Cool, Dry, Fan and Auto, or Heat.

Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces humidity. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated. Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated. Fan Mode: The Fan Mode works in only ventilation. Press MODE button to set the FAN mode. With pressing FAN SPEED button the speed changes in the following sequence: Hi, Med and Lo in FAN mode. The remote control also stores the speed that was set in the previous mode of operation. Auto Mode: In AUTO mode the unit automatically chooses the fan speed and the mode of operation (COOL,DRY or FAN).In this mode the fan speed and the temperature are set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.). Heat Mode: The heating function allows the air conditioner to heat the room. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated.

5. Timer Button: Use these buttons on the control

panel and remote to set the Timer. Timer Off: The timed stop is programmed by

pressing TIMER button. Set the rest time by

pressing the button

or

until the rest

time displayed is to your demand then press TIMER button again. Timer On: When the unit is off, press TIMER

button at the first time, set the temperature with

pressing the button

or

. Press TIMER

button at the second time, set the rest time with

pressing the button

or

. Press TIMER

button a third time, confirm the setting, then the

display will show the time the machine will automatically turn on

Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the

buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above.

The SET light will turn on while setting. To cancel the set function, press the TIMER

button again.

9

6. Eco Button: When the unit is in ECO mode, the 10.Directional Louvers: To direct the airflow,

light will turn on. In ECO mode, the unit will

horizontal wheel to control the horizontal direction,

turn-off once the room is cooled to the user set

air deflector to control the vertical direction.

temperature. The fan will also be off at this point.

The unit will turn back on when the room

temperature rises above the user set temperature.

Before the compressor stars, the fan motor will

run for a while, then it will stop for a while-and will repeat to provide a much more comfortable-feeling

air deflector

horizontal wheel

air deflector

and save energy.

7. Sleep Button: Press the SLEEP button, the Sleep Light will be on after 10s, and all the left lights will be off. In SLEEP mode, the air-conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. For cooling mode, the set temperature will automatically raise by 1 F every 30-60 minutes and at most change six times until the set temperature is 82 F. For heating mode, the set temperature will automatically decrease by 1 F every 30-60 minutes and at most change six times until the set temperature is 75 F. And every running time depends on the set temperature.
8. Fan Speed Button: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL mode and choose Hi, Med, Lo in FAN mode.

9. Filter Button: The Led (light ) will illuminate after 500 hours of operation as a reminder to clean the Air cleaning the filter,press the Check Filter button and the light will turn off.

10

1

2

3

4

7

5

8

6

9

10

3

HEAT

*For mark 6 button, it is AUTO MODE for coolling only, and it is HEAT for heating model.
1. Power: Turn the air conditioner on and off.
2. Cool: Press the COOL button to COOL mode.
3. and : Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61 ~88 or 16 ~31 .
4. Sleep: Press the SLEEP button, the Sleep Light will be on after 10s, and all the left lights will be off. In SLEEP mode, the air-conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise by 1 every 30-60 minutes and at most change six times until the set temperature is 28 . And every running time depends on the set temperature.

5. Timer: Use these buttons on the control panel

and remote to set the Timer.

Timer Off: The timed stop is programmed by

pressing TIMER button. Set the rest time by

pressing the button

or

until the rest

time displayed is to your demand then press

TIMER button again.

Timer On: When the unit is off, press TIMER

button at the first time, set the temperature with

pressing the button

or

. Press TIMER

button at the second time, set the rest time with

pressing the button

or

. Press TIMER

button at the third time, confirm the setting,

then the display will show the time the machine will

automatically turn on.

Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the setted function, press the TIMER button again. 6. a.Auto Mode: In AUTO mode the unit automatically chooses the fan speed and the mode of operation (COOL,DRY or FAN).In this mode the fan speed and the temperature are set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.). It is for cooling only model.
b.HEAT: Press the HEAT button to HEAT mode. It is for heating model.

7. Fan Speed: Press the FAN SPEED button to choose the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL mode and choose Hi, Med, Lo in FAN mode.
8. Display: Press the DISPLAY button to switch on/off all lights or LED display.

9. Eco: When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn-off once the room is cooled to the user set temperature. The fan will also be off at this point. The unit will turn back on when the room temperature rises above the user set temperature.Before the compressor stars, the fan motor will run for a while, then it will stop for a while-and will repeat to provide a much more comfortable-feeling and save energy.
10. Fan Only: Press the Fan Only button to FAN ONLY mode.