Product Information
The HG60FX, HG75FX-M, and HG90FX-M are gas cooktop appliances designed for household and similar applications. They are suitable for use in staff kitchen areas, farmhouses, hotels, motels, bed and breakfast establishments, and other residential-type environments.
The cooktops come with various burners including an auxiliary burner, semi- rapid burner, triple crown burner (wok on 5 burner models), and double crown burner (wok on 4 burner models). The burners provide different power levels for efficient cooking.
The cooktops comply with several Directives including EEC 2009/142/CE (Gas), EEC 2006/95/CE (Low Voltage), EEC 2004/108/CE (Electromagnetic Compatibility), and EEC 2004/1935/CE (Contact with Foods).
Important Notice: The manufacturer does not take responsibility for damages caused by incorrect installation or improper use of the equipment. It is essential to read and follow the user manual for proper installation and usage instructions.
Specifications
Burner | Power (MJ/h) | NG | LPG | Cookware Diameter Range |
---|---|---|---|---|
Auxiliary | 3.4 | 3.4 | 10 – 14 cm | |
Semi-rapid | 6.3 | 5.6 | 16 – 18 cm | |
Triple Crown (wok on 5 burner models) | 18.0 | 15.0 | 24 – 26 cm | |
Double Crown (wok on 4 burner models) | 10.3 | 9.6 | 20 – 22 cm |
Product Usage Instructions
Installation and Setup
- Ensure that the installation, adjustment, and adaptation to the available gas type are carried out by authorized personnel in accordance with the regulations.
- Follow the specific instructions provided in the installation section of the user manual.
Using the Burners
The symbols silk-screen printed on the side of the knob indicate the
correspondence between the knob and the burner.
Automatic Start-up with Valves
To start the burner using automatic start-up:
- Turn the corresponding knob anticlockwise up to the maximum position (large flame, fig.1/1/A).
- Press the knob.
- Once the burner has been started up, keep the knob pressed for about 6 seconds.
Note: The triple ring (wok) burner only switches on in the maximum flame position.
Cookware Requirements
It is important to use cookware with the specified sizes for each burner. Ensure that the cookware is always correctly centered over the burner.
Using oversized cookware can potentially cause heat damage to your benchtop and/or control knobs, which will not be covered under warranty.
For cookware with a diameter of 120mm or below, use the mini-trivet supplied. Refer to the fitment instructions on page 15 of the user manual.
FAQ
Q: What should I do if I have a problem with the cooktop?
If you encounter a problem with the cooktop, refer to the table below for
potential solutions:
You may be able to solve the problem on your own and avoid paying for a
service call. However, if the problem is listed below, even within the
warranty period, you will have to pay for a service call.
GENERAL NOTICE
We invite you to read this instruction booklet carefully, before installing
and using the equipment. It is very important that you keep this booklet
together with the equipment for any future consultation.
If this equipment should be sold or transferred to another person, make sure
that the new user receives the booklet, so that they can learn how to operate
the appliance and read the corresponding notice.
This is a Class 3 appliance.
This appliance complies with the following Directives:
EEC 2009/142/CE (Gas) EEC 2004/108/CE (Electromagnetic Compatibility)
EEC 2006/95/CE (Low Voltage) EEC 2004/1935/CE (Contact with foods)
WARNING
- The installation must be carried out by authorised personnel, in conformity with the regulations in force.
- CAUTION: The surface temperature of underbench components exceeds 95°C. To avoid a hazard, underbench access must be restricted. Refer to the installation instructions.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- Before powering the equipment, check that it is properly adjusted for the type of gas at disposal (see the “installation” paragraph).
- If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
- Before carrying out the maintenance or cleaning the equipment, cut off power supply and allow it cool down.
- Make sure that air circulates around the gas equipment. Insufficient ventilation produces a lack of oxygen.
- In case of an intense or prolonged use of the equipment, it may be necessary to improve aeration, for example by opening a window or increasing rangehood venting power, if it exists.
- The products of combustion must be discharged outside through a suction hood or an electric fan (see the “installation” paragraph).
- For any possible operation or modification, apply to an authorized Technical Assistance Centre and demand original spare parts.
- Where this appliance is installed in marine craft or in caravans, it shall not be used as a space heater.
- Not for use in marine craft, caravans or mobile homes unless each burner is fitted with a flame safeguard.
- Do not spray aerosols in the vicinity of the appliance while it is in operation.
- Do not store or use flammable materials or items in the vicinity of this appliance.
DO NOT MODIFY THIS APPLIANCE.
Servicing shall be carried out only by authorised personnel.
The product label, with the serial number, is fixed to the underside of hob.
An additional label should be adhered to adjacent cabinetry for easy access-
refer installation instructions.
The manufacturer refuses all responsibility for possible damages to things or
people, resulting from incorrect installation or from an improper, incorrect
or unreasonable use of this equipment.
INSTRUCTIONS FOR THE USER
It is necessary that all the operations regarding the installation, adjustment and adaptation to the type of gas available are carried out by authorised personnel, in conformity with the regulations in force. The specific instructions are described in the booklet section intended for the installer.
Conditions of Use
This appliance is intended to be used in household and similar applications
such as:
- Staff kitchen areas in shops, offices and other working environments
- Farm Houses
- By clients in hotels, motels and other residential type environments
- Bed and breakfast type environment
USING THE BURNERS
The symbols silk-screen printed on the side of the knob indicate the
correspondence between the knob and the burner.
Automatic start-up with valves
Turn the corresponding knob anticlockwise up to the maximum position (large
flame, fig.1/1/A) and press the knob.
Once the burner has been started up, keep the knob pressed for about 6
seconds.
ATTENTION: the triple ring (wok) burner switches on only in the maximum flame position
Using the burners
In order to obtain the maximum yield without waste of gas, it is important
that the diameter of the pot is suitable for the burner potential (see the
following table), so as to avoid that the flame going out (fig. 2).
Use the maximum capacity to quickly make liquids reach boiling temperature,
and the reduced capacity to heat food or maintain boiling. All of the
operating positions must be chosen between the maximum and the minimum ones,
never between the minimum position and the closing point.
The gas supply can be interrupted by turning the knob clockwise up to the
closing position. If there is no power supply, it is possible to light the
burners with matches, setting the knob to the start-up point (large flame,
fig. 1).
BURNERS
| Power (MJ/h)| *Ø of cookware ()**
---|---|---
NG| LPG
Auxiliary| 3,4| 3,4| 10 – 14 cm
Semi-rapid| 6,3| 5,6| 16 – 18 cm
Triple crown (wok on 5 burner models)|
18,0
|
15,0
|
24 – 26 cm
Double crown (wok on 4 burner models)|
10,3
|
9,6
|
20 – 22 cm
(*) For cookware with diameter 120mm or below use mini-trivet supplied, refer fitment instructions on page 15.
It is important to use cookware with the sizes specified and ensure the cookware is always correctly centred over the burner. Using oversize cookware can potentially cause heat damage to your benchtop and/or control knobs which will not be covered under warranty.
Notice
- When the equipment is not working, always check that the knobs are in the closing position (see fig.1).
- If the flame should blow out accidentally, the safety valve will automatically stop the gas supply, after a few seconds. To restore operation, set the knob to the lighting point (large flame, fig. 1) and press.
- While cooking with fat or oil, pay the utmost attention as these substances can catch fire when overheated.
- Do not place unstable or deformed pots on the burner, so as to prevent them from overturning or overflowing.
- Handles should be turned away from the front of the bench to avoid accidents.
- When the burner is started up, check that the flame is regular and, before taking pots away, always lower the flame or put it out.
- Burner 3 Injector
- Flame safeguard sensor
- Ignition spark plug
If you have a problem with the cooktop, check the table below. You may be able to solve the problem and this will save you from paying for a service call. You will have to pay for a service call even in the warranty period if the problem is one listed below
FAULT | POSSIBLE CAUSES | REMEDY |
---|---|---|
Burner will not light even though the sparker is working. | Knob not held down | |
long enough in ‘High’ position for flame safeguard to engage | Repeat lighting |
procedure and hold knob down for 6 seconds in ‘High’ position (refer page 3)
Gas supply valve turned off| Turn on gas supply to appliance
Wrong knob turned| Ensure the knob you are turning corresponds to the burner
you want to light
Port blockage in ignition area| Ensure that ports in ignition area are clean
and dry
Ignition spark plugs wet or dirty| Dry or clean ignition spark plugs
Injector blocked| Ensure the injector remains free of any foreign material. If
necessary, use a thin piece of wire to clear the orifice.
No spark is obtained when control knob is activated| Electricity supply is
disconnected or switched off”| Switch on electricity or check fuses
Ignition spark plugs wet or dirty| Dry or clean ignition spark plugs
Flames uneven or tending to lift| Flame ports blocked or wet| Clean or dry
flame ports
Burner incorrectly fitted| Ensure this component is fitted correctly
Flames not staying on when knob released| Knob not held down long enough in
‘High’ position for flame safeguard (where fitted) to engage| Repeat lighting
procedure and hold knob down for 6 seconds in ‘High’ position (refer page 3)
Knob not set between ‘High’ and ‘Low’| Knob MUST be set between these
positions
Dirt or spillage on flame safeguard sensor (where fitted)| Clean flame safe
guard sensor tip
Low heat, slow cooking| Incorrect cooking pot or pan being used| Refer to
table page 3
Benchtop or knobs overheating| Incorrect cooking pot or pan used| Check table
on page 3 for correct pot or pan to be used
Pot or pan not located on burner properly| Ensure pot or pan is centrally
located on burner
Cooktop stainless steel discoloured| Pot or pan being is too large| Ensure pot
sizes used are as per user manual requirements. Clean with STEEL POWER
(available through spare parts).
Outer ring of wok burner goes out when set to low| This is not a failure. This
is a function of the dual wok burner to give a very low power flame option| No
remedy – burner is functioning as intended
If the above points have been checked and there is still a problem with the cooktop, please call the Service Centre.
CLEANING
Before any operation, disconnect the appliance from the electrical supply.
Don’t use a steam cleaner for the cleaning the hob.
It is advisable to clean the appliance when it is cold.
Enamelled parts
The enamelled parts must be washed with a sponge and soapy water or with a
light detergent.
Do not use abrasive or corrosive products.
Do not leave substances, such as lemon or tomato juice, salt water, vinegar,
coffee and milk on the enamelled surfaces for a long time.
Stainless steel parts
Stainless steel can be stained if it remains in contact with highly alkaline
water or aggressive detergents for an extended period of time.
All grades of stainless steel may stain, discolour or attain an adhering layer
of grime in normal operation. To achieve optimum surface appearance stainless
steel must be kept clean regularly using the following cleaning procedures,
this ensuring good performance and long service life.
Wash with warm soapy water and rinse with clean water. Where the stainless
steel has become extremely dirty with signs of surface discolouration (due to
periods of neglect or misuse) use a stainless steel cleaner
DO NOT use abrasive scourers or steel wool. When removing these stains be sure
to follow the polish of brushing lines.
Burners and racks
These parts can be removed to make cleaning easier.
The burners must be washed with a sponge and soapy water or with a light
detergent, wiped well and placed in their housing perfectly. Make sure that
the flame-dividing ducts are not clogged. Check that the feeler of the safety
valve and the start-up electrode are always cleaned, so as to ensure optimum
operation.
Gas taps
The possible lubrication of the taps must be carried out by authorised
personnel, exclusively.
In case of malfunctions of the gas taps call customer service
Important notice:
The operations indicated below must be followed by authorised personnel
exclusively, in conformity with the regulations in force.
The manufacturing firm refuses all responsibility for damages to people,
animals or things, resulting from the failure to comply with such provisions.
This appliance shall be installed only by authorised persons and in accordance
with the manufacturer’s installation instructions, local gas fitting
regulations, municipal building codes, electrical wiring regulations, and any
other statutory regulations. For Australia and New Zealand this appliance must
be installed by an authorised person in compliance with AS/NZS 5601.1 Gas
installations part 1: general installations, and AS/NZS 5601.2 Gas
installations part 2: LP GAS installations in caravans and boats for
nonpropulsive purposes. For outside of Australia/New Zealand refer to the
relevant installation code for gas appliances in your country.
INSTALLATION
The installation kit contains the following:
- 1 natural gas regulator
- 1 elbow
- 1 manifold
- 2 fibre sealing washers
- 4 brackets for assembly
- 4 bracket screws
- 1 pack of cooktop to benchtop seals
- 1 duplicate rating label
- For conversion to LPG
- 1 Universal LPG sticker
- 4 or 5 injectors
Additional accessory for cooking with vessels diameter 120mm or below
- 1 mini trivet
- 1 wok trivet
Installing the top
The appliance is designed to be embedded into heat-resistant benchtop capable
of withstanding 85°C.
Adjacent walls, cupboards and protection for combustible materials.
Ensure that the appliance is installed in accordance with clauses 6.2.5 and
6.10.1.1 of AS/NZS 5601.1, or clauses 6.9.1 and 6.9.5 of AS/NZS 5601.2 with
regard to clearances to combustible surfaces and materials, and clearances to
rangehoods and exhaust fans.
Clearance of 200mm from the periphery of burners to vertical combustible
surfaces is required. Clearances to combustible surfaces may be reduced only
if combustible surfaces are protected in accordance with clause 6.10.1.2 of
AS/NZS 5601.1, or clause 6.9.2 of AS/NZS 5601.2.
The equipment must not be installed near inflammable materials, such as
curtains, cloths,etc. Make a cut out in the benchtop, with the dimensions
indicated in fig.3, at a distance of at least 50 mm from the appliance border
to the adjacent walls.
MODEL | L (mm) | P (mm) | D (mm) |
---|---|---|---|
HG60FX | 560 | 480 | 60 |
HG75FX-M | 720 | 480 | 60 |
HG90FX-M | 860 | 480 | 60 |
Any possible wall unit over the cook-top must be placed at a distance of at least 760 mm from the top.
IMPORTANT:
A separation panel at least 10mm from the bottom of the cooktop must be
included during installation to prevent access to the underside of the
appliance. This panel can be made of any non-combustible rigid material. Refer
(fig. 4).
If the hob is going to be installed on the top of an oven, precautions must be
taken to guarantee an installation in accordance with current accident
prevention standards. Pay particular attention to the position of the electric
cable and gas pipe: they must not touch any hot parts of the oven.
Moreover, if the hob is going to be installed on the top of a built in oven
without forced cooling ventilation, proper air vents must be installed to
guarantee an adequate ventilation, with the lower air entering with a cross
section of at least 200cm2, and the higher air exiting with a cross section of
at least 60 cm2.
Fastening the top
Every cook-top is equipped with a special washer.
A set of hooks is also supplied for mounting the cook-top.
Depending on the type of mounting surface, the suitable type of mounting hook is supplied (hook A or hook B).
For the installation proceed as follows:
- Remove all loose components from the top.
- Turn the appliance upside down lay it’s edges on foam packaging blocks to prevent damage to the ignition spark plugs and lay the seal S along the external border (fig. 5).
- Introduce and place the cook-top in the hole made in the piece of furniture, then fasten it with the screws and fastening brackets supplied (fig.6).
WARNING: Failure to fix the cooktop to the bench could result in
loosening of the gas connection through movement of the cooktop and a gas leak
may result.
A duplicate rating label is included with these instructions. Ensure this is
attached to a readily accessible surface, so that the cooktop can be easily
identified in the case of a service call.
INSTALLATION ROOM
This appliance is not provided with a device for exhausting the products of
combustion.
Therefore, it is necessary to discharge these outside.
The room where this appliance is installed must have a natural air inflow, so
as to ensure a regular gas combustion and room ventilation: the necessary air
volume must not be lower than 20m3.
Air must come from permanent openings made on the room walls that communicate
with the outside.
The section of these openings shall correspond to at least 200 cm2.
OPERATION ON N.G / S.N.G.
Regulator
An appliance regulator is provided. The regulator must be positioned so that
the pressure test nipple is accessible when the appliance is installed.
Connect the gas supply to the 1/2″ B.S.P. internal thread inlet of the
regulator. Refer to page 8 for connection point position.
Regulators are supplied pre-adjusted and configured by the component maker for
use with Natural Gas. The appliance installer is not required to make an
adjustment to obtain the correct outlet pressure setting.
An arrow on the base of the regulator indicates the direction of gas flow when
the inlet and outlet of the regulator is orientated correctly. When the
regulator has been fitted check for leaks from the connections with soapy
water.
Gas Connection
This appliance is supplied for use with Natural Gas. However, it can be
converted for use with LPG. Refer to LP conversion chapter.
Supply pipe sizing
The total hourly gas consumption for the appliance is shown on the data label.
The required supply pressure (i.e. at inlet to appliance regulator) for each
gas type is shown on the data label, and given in page “TECHNICAL
CHARACTERISTIC TABLES”. Use this information in conjunction with the length of
run, number of elbows, tees and bends, the available service pressure and the
supply requirements of other installed appliances to determine a suitable pipe
size. For assistance in this matter refer to the appropriate section of the
Installation Code AS5601.
An AGA certified class B or D flexible connection may be used to connect the cooktop in accordance with the AS5601 and in particular section 4.8. Where a hose assembly is used and the cooktop is in the installed position, the hose assembly shall be suitable for connection to a fixed consumer piping outlet located at a point 800 – 850mm above the floor and in the region outside the width of the appliance to a distance of 250mm. The point of connection to consumer piping must be accessible with appliance installed.
Elbow positioning
It is possible to reposition the elbow if required by loosening the locking
nut and elbow by using two spanners. Re-tighten the entire assembly after the
elbow has been repositioned. When fitting elbow to appliance, ensure that the
sealing washer is fitted.
Regulator
An appliance regulator is provided. The regulator must be positioned so that
the pressure test nipple is accessible when the appliance is installed.
Connect the gas supply to the ½” B.S.P. internal thread inlet of the
regulator. Refer page 10 for connection point position.
Assembly of Regulator
- The assembly of the regulator to the cooktop manifold is achieved via the elbow union and sealing washersupplied.
- The ½” parallel thread connects to the manifold, and the sealing washer is placed between the manifold end and the flat face on the elbow.
- The ½” tapered thread connects to the outlet of the regulator, and is sealed on the thread using approved thread sealing tape or approved thread sealing compound.
- The inlet of the regulator is a ½” parallel thread and is connected to consumer piping or hose assembly.
- Regulators are supplied pre-adjusted and configured by the component maker for use with Natural Gas.
- The appliance installer is not required to make an adjustment to obtain the correct outlet pressure setting.
- An arrow on the base of the regulator indicates the direction of gas flow when the inlet and outlet of the regulator is orientated correctly. When the regulator has been fitted check for leaks from the connections with soapy water.
Checking the gas supply
- Check the manometer zero point is correct.
- Connect the manometer to the cooktop pressure point. This is located on the regulator.
- Turn on the gas supply and electricity and try to ignite the gas. NOTE! lt will take additional time to light the gas for the first time as air needs to be purged from the pipes.
- With the appliance operating check the outlet pressure
- when all burners of the appliance are operating at maximum,
- when the smallest burner of the appliance is operating at minimum.
Under these conditions the outlet pressure should not vary from the nominal
outlet pressure of 1.00kPa by more than ± 0.20kPa
If the regulator appears to not perform satisfactorily, then check the
following points:
- If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed, or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line. If this is suspected then it may be necessary to repeat fhe checks whilst measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 1.13 – 5kPa.
- Check that the regulafor has been fitted to the gas supply line in the correct orientation, the arrow on the base of the body indicates the direction of gas flow.
Once these checks have been completed, if the regulator still fails to perform in a satisfactory manner it should be replaced.
Electrical connection
The appliance is supplied with a standard 10 Amp service cord terminated by a
3-pin plug for connection to a standard household socket. The electrical
supply is required to power the electronic ignition system.
NOTE: It will be necessary for servicing purposes to disconnect the electrical power supply. The power point should therefore be accessible after the appliance is installed, as specified in the local wiring regulations.
TESTING APPLIANCE OPERATION
After installation the installer must fully test the appliance and ensure it
operates correctly before handing it over to the customer.
GAS CONVERSIONS AND ADJUSTMENTS
Data Label
This appliance is suitable for Natural Gas and Universal LPG; ensure that the
available gas supply matches the Data Label.
When converting from Natural Gas to Universal LPG ensure that the NG regulator
is removed and replaced with the Test Point Assembly. An AGA Approved gas
regulator suitable for a supply pressure of 2.75kPa should be part of the gas
tank supply and the test point pressure should be adjusted to 2.75kPa.
Replacing the injectors
If the equipment is adjusted for a type of gas that is different from the one
available, it is necessary to replace the burner injectors.
The choice of the injectors to replace must be made according to the table of
the “technical characteristics” as enclosed.
Act as follows:
- remove the racks and burners.
- by means of a straight spanner L, unscrew the injectors U (fig.7 – 7/A) and substitute it with the corresponding one. Please note the wok burner on models HG75FX-M and HG90FX-M has three injectors (refer U1 & U2 of Figure 7/A for positions)
- tighten the injectors strongly.
After changing the injectors, it is necessary to eliminate residual natural
gas in the system.
To do this you have to turn to the maximum position then press the knob of
each burner and wait few seconds.
Adjusting the burners
The lowest flame point must always be properly adjusted and the flame must
remain on even if there is an abrupt shift from the maximum to the minimum
position.
If this is not so, it is necessary to adjust the lowest flame point as
follows:
- start the burner up
- turn the tap up to the minimum position (small flame)
- remove the knob from the tap rod
- introduce a flat-tip screwdriver in the hole F of the tap (fig.8) and turn the by-pass screw up to a proper adjustment of the lowest flame point.
For the models with triple crown is possible adjust the lowest flame point for
the external or internal ring. Is sufficient to turn the screws indicated in
fig. 8/A.
As regards U-LPG gas burners, the by-pass screw must be tightened completely.
MAINTENANCE
Maintenance Schedule
No regular maintenance is required for the hotplates except cleaning.
Replacing the power supply cable
If the power supply cable should be replaced, it is necessary to use a cable
with a section of 3×0.75mm2, type H05VV-F or H05RR-F, complying with the
regulations in force.
The connection to the terminal board must be effected as shown in fig.9 – 9/A:
- brown cable L (phase)
- blue cable N (neutral)
- green-yellow cable (ground
Stainless steel can be stained if it remains in contact with highly alkaline
water or aggressive detergents for an extended period of time.
All grades of stainless steel may stain, discolour or attain an adhering layer
of grime in normal operation. To achieve optimum surface appearance stainless
steel must be kept clean regularly using the following cleaning procedures,
this ensuring good performance and long service life.
Wash with warm soapy water and rinse with clean water. Where the stainless
steel has become extremely dirty with signs of surface discolouration (due to
periods of neglect or misuse) use a stainless steel cleaner DO NOT use
abrasive scourers or steel wool. When removing these stains be sure to follow
the polish of brushing lines.
TECHNICAL CHARACTERISTIC TABLES
BURNERS| GAS| NORMAL PRESSURE| INJECTOR DIAMETER| TAPE BY PASS DIAMETER| ****
NOMINAL HEAT INPUT
(MJ/h)
---|---|---|---|---|---
N°| DESCRIPTION| KPa| 1/100 mm| 1/100 mm
2
| ****
SEMI-RAPID
| Universal LPG| 2.75| 65| 31| 5.6
Natural| 1.00| 110| 1/2 turn| 6.3
3
| ****
AUXILIARY
| Universal LPG| 2.75| 52| 27| 3.4
Natural| 1.00| 80| 1/4 turn| 3.4
4
| ****
TRIPLE (WOK) CROWN
| Universal LPG| 2.75| 50 / 68 (x2)| 60| 15.0
Natural
| ****
1.00
| ****
75 / 130 (x2)
| 1/3 turn inner / 1 turn outer| ****
18.0
5
| DOUBLE (WOK) CROWN| Universal LPG| 2.75| 85| 60| 9.6
Natural| 1.00| 145| Adjust.| 10.3
WIRING DIAGRAM
INSTRUCTIONS FOR USING THE MINI TRIVET
Please note the step of the trivet fingers on the wok burner main trivet. (applicable for models HG75FX-M and HG90FX-M) To avoid spillages lift and move cooking receptacles to and from this burner rather than sliding across the trivets
Warranty
FOR SALES IN AUSTRALIA AND NEW ZEALAND ALL AEG BRANDED APPLIANCES
This document sets out the terms and conditions of the product warranties for AEG Appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference should you require service for your Appliance.
- In this warranty: (a) ‘acceptable quality’ as referred to in clause 10 of this warranty has the same meaning referred to in the ACL; (b) ‘ACL’ means Schedule 2 to the Competition and Consumer Act 2010; (c) ‘Appliance’ means any AEG product purchased by you and accompanied by this document; (d) ‘ASC’ means AEG authorised service centres; (e) AEG is the brand controlled by Electrolux Home Products Pty Ltd of 163 O’Riordan Street, Mascot NSW 2020, ABN 51 004 762 341 in respect of Appliances purchased in Australia and Electrolux (NZ) Limited (collectively ‘Electrolux’) of 3-5 Niall Burgess Road, Mount Wellington, in respect of Appliances purchased in New Zealand; (f) ‘major failure’ as referred to in clause 10 of this warranty has the same meaning referred to in the ACL and includes a situation when an Appliance cannot be repaired or it is uneconomic for Electrolux, at its discretion, to repair an Appliance during the Warranty Period; (g) ‘Warranty Period’ means the Appliance is warranted against manufacturing defects in Australia and New Zealand for 60 months, following the date of original purchase of the Appliance; (h) ‘you’ means the purchaser of the Appliance not having purchased the Appliance for re-sale, and ‘your’ has a corresponding meaning.
- This warranty only applies to Appliances purchased and used in Australia or New Zealand in normal domestic applications and is in addition to (and does not exclude, restrict, or modify in any way) any non-excludable statutory warranties in Australia or New Zealand.
- During the Warranty Period Electrolux or its ASC will, at no extra charge if your Appliance is readily accessible for service, without special equipment and subject to these terms and conditions, repair or replace any parts which it considers to be defective. Electrolux or its ASC may use remanufactured parts to repair your Appliance. You agree that any replaced Appliances or parts become the property of Electrolux. This warranty does not apply to light globes, batteries, filters or similar perishable parts.
- Parts and Appliances not supplied by Electrolux are not covered by this warranty.
- To the extent permitted by law, you will bear the cost of transportation, travel and delivery of the Appliance to and from Electrolux or its ASC. If you reside outside of the service area, you will bear the cost of: (a) travel of an authorised representative; (b) transportation and delivery of the Appliance to and from Electrolux or its ASC. In all instances, unless the Appliance is transported by Electrolux or an AEG authorised representative, the Appliance is transported at the owner’s cost and risk while in transit to and from Electrolux or its ASC.
- Proof of purchase is required before you can make a claim under this warranty.
- You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship. Electrolux is not liable in the following situations (which are not exhaustive): (a) the Appliance is damaged by: (i) accident (ii) misuse or abuse, including failure to properly maintain or service (iii) normal wear and tear (iv) power surges, electrical storm damage or incorrect power supply (v) incomplete or improper installation (vi) incorrect, improper or inappropriate operation (vii) insect or vermin infestation (viii) failure to comply with any additional instructions supplied with the Appliance; (b) the Appliance is modified without authority from Electrolux in writing; (c) the Appliance’s serial number or warranty seal has been removed or defaced; (d) the Appliance was serviced or repaired by anyone other than Electrolux, an authorised repairer or ASC.
- This warranty, the contract to which it relates and the relationship between you and Electrolux are governed by the law applicable where the Appliance was purchased. Where the Appliance was purchased in New Zealand for commercial purposes the Consumer Guarantee Act does not apply
- To the extent permitted by law and subject to your non-excludable statutory rights and warranties, AEG excludes all warranties and liabilities (other than as contained in this document) including liability for any loss or damage whether direct or indirect arising from your purchase, use or non use of the Appliance.
- For AEG Appliances and services in Australia, the Appliances come with a guarantee that cannot be excluded under the ACL. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the Appliance repaired or replaced if the Appliance fails to be of acceptable quality and the failure does not amount to a major failure. The benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to the Appliances or services to which the warranty relates.
- At all times during the Warranty Period, Electrolux shall, at its discretion, determine whether repair, replacement or refund will apply if an Appliance has a valid warranty claim applicable to it.
- For Appliances and services provided in New Zealand, the Appliances come with a guarantee pursuant to the provisions of the Consumer Guarantees Act, the Sale of Goods Act and the Fair Trading Act.
- To enquire about claiming under this warranty, please follow these steps: (a) carefully check the operating instructions, user manual and the terms of this warranty; (b) have the model and serial number of the Appliance available; (c) have the proof of purchase (e.g. an invoice) available; (d) telephone the numbers shown below.
- You accept that if you make a warranty claim, Electrolux and its ASC may exchange information in relation to you to enable Electrolux to meet its obligations under this warranty.
Important Notice
Before calling for service, please ensure that the steps listed in clause 13
above have been followed.
FOR SERVICE
or to find the address of your nearest state service centre in Australia PlEASE CAll 1300 363 664
OR EMAIlcustomercare@aegaustralia.com.au
For the cost of a local call (Australia only)
| SERVICE AUSTRAlIA
| FOR SPARE PARTS
or to find the address of your nearest state spare parts centre in Australia PlEASE CAll 13 13 50
OR EMAIlcustomercare@aegaustralia.com.au
For the cost of a local call (Australia only)
---|---|---
FOR SERVICE
or to find the address of your nearest authorised service centre in New Zealand FREE CAll 0800 10 66 10
OR EMAIlcustomercare@electrolux.co.nz
(New Zealand only)
| SERVICE NEW ZEAlAND
| FOR SPARE PARTS
or to find the address of your nearest state spare parts centre in New Zealand FREE CAll 0800 10 66 20
OR EMAIlcustomercare@electrolux.co.nz
(New Zealand only)
---|---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>