Installation Instructions
DN Size
| 65 2 1/2”| 80 3”| 100 4”| 125 5”|
150 6”| 200 8”
---|---|---|---|---|---|---
Sp [kPa] / [psi]
| ΔH = 0-400 kPa / 0-58 psi| 45 / 6.5
ΔH = 400-1200 kPa / 58-174 psi|
65 / 9.4
Kv min / Cv min
| 4 / 5
Kv m / Cv m|
75 / 87
| 110 / 127| 180 / 208| 270 / 312| 400 / 462| 600 / 694
qmax [m3 /h] / [gpm]
| 53 / 233| 78 / 343| 127 / 559| 191 / 841| 283 / 1246|
424 / 1867
Sp = Sealing pressure, the increase of ΔpL in kPa (psi) when a Δp
controller controls ΔpL from Kvmin (Cvmin) down to zero flow
Kvmin (Cvmin) = m3 /h (gpm) at a pressure drop of 1 bar (1 psi) and
minimum opening corresponding to the p-band.
Kvm (Cvm) = m3 /h (gpm) at a pressure drop of 1 bar (1 psi) and maximum
opening corresponding to the p-band.
qmax = The maximum recommended flow through a Δp controller.
ΔH = Available differential pressure.
| 10-50| 30-150| 80-400| kPa
---|---|---|---|---
10| 30| 80
1 – 7| 4 – 21| 2 – 58| psi
1| 4| 12
**| DN| 65| 80| 100| 125| 150| 200
---|---|---|---|---|---|---|---
H [mm]| 274| 281| 303| 313| 331| 361
Size| 2 1/2”| 3”| 4”| 5”| 6”| 8”
H [in.]**| 10.7| 11.1| 11.9| 12.3| 13| 14.2