BRISTAN RS2 SHCDIV C Renaissance Thermostatic Recessed Dual Control Shower Valve Instruction Manual

June 4, 2024
BRISTAN

RS2 SHCDIV C Renaissance Thermostatic Recessed Dual Control Shower Valve

Installation Instructions & User Guide
Please leave these instructions with the end user

Specifications

Dynamic Water Pressure

Min: 0.2 bar

Water Pressure

Max: 5.0 bar

guide pressure

Maximum Static Pressure: 10.0 bar

Cold Water Supply

Cold Water Supply

Min: 5°C Max: 25°C

Hot Water Supply

guide vamp

65°C Recommended

IMPORTANT The inlet hot water must be at least 10°C above the required blend temperature.

Inlet Dimensions

Tools You’ll Need

tools

Prior to Installation

Please leave these instructions with the end user
All products manufactured and supplied by Bristan are safe to use
provided that they are installed, operated and receive regular
maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999
and current by-laws. For full Installation Requirements & Notes (IRN)
please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease
of future maintenance. Before installing this product the water supply
must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/
servicing purposes.
Before drilling into walls, check that there are no hidden electrical
wires, cables or water supply pipes. This can be checked with the
aid of an electronic detector.
If power tools are used do not forget to:
– Wear eye protection
– Unplug equipment after use
This product must not be modified in any way
as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791

Cavity Dimensions (mm)

Cavity Depth: 35mm

Concealing Plate
Adjustment Range: 30mm

Pack Contents

valve connectionadjustment spindle

General Cleaning

Bristan products are made from premium materials, with
hand polishing and electroplated finishes.

Your taps or shower should be regularly cleaned with warm water, a mild pH- neutral liquid soap, and polished with a soft cloth. Any residues from soap, toiletries etc. should be rinsed off straight after use.

Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.

Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts.

Operation

Wall Outlet Installation

Choose the location for the wall outlet and create a 25-30mm hole in the wall. Ensure your shower accessories have enough reach from that position.
Finish the wall surface.

Servicing Intervals

To reduce the build up of lime scale and to ensure this shower works to its maximum performance we recommend this shower is serviced every 6-12 months depending on the hardness of your water

With rear access

Fit the wall outlet, ensuring the
washers are fitted either side of
the wall.

Without rear access

Follow Step 6 in the Installation Steps, fitting a 1/2” female connection at the hole in the wall (not supplied).

Screw the wall outlet into the 1/2” female connection, using a suitable thread sealant ensuring the rubber seal is fitted to the back of the wall outlet.

maintenance

Troubleshooting

Symptom Cause Remedy

No flow or
low flow rate

| Partially closed isolation valve.|

Open isolation valve.

Instantaneous water heater cycles on and off
as flow rate or pressure is too low.|

Increase water flow rate or
pressure through system.

Head of water is below the
minimum distance required.|

Refer to the specification for the
minimum distance required.

Are the water supply pressures balanced?|

If pressures are unbalanced, a pressure reducing valve
should be used for optimum performance.

Hot or cold water being drawn off elsewhere
causing pressure changes or instantaneous
boiler temperature changes.|

Do not use other water outlets when using the shower.

Airlock or partial blockage in the supply
pipework.|

Flush through pipework and filters to ensure removal
of debris and any airlocks.

Hot/Cold water supply has failed|

Check the hot and cold feeds. The shower will not
work if either fails.

Maximum
Water
Temperature
too Hot/Cold| Maximum Water Temperature
needs adjusting.|

Refer to the Temperature Setting section to set your
desired maximum temperature.

Outlet Water
Temperature
too Hot/Cold

| Filter/pipe blockage|

Flush through pipework and filters to ensure
removal of debris and any airlocks.

Installtion conditions outside
operating parameters.|

Refer to the specification for the
minimum distance required.

Hot water temperature is less than 10°C
above the required blend temperature|

Adjust hot water temperature or wait for water to
reheat if a stored water system is used.

Instantaneous water not igniting because the
water flow rate is too low.|

Increase water flow rate through the system. Refer to the
Maintenance section to clean/check the cartridge and filters
for any damage. Contact your boiler manufacturer.

Instantaneous water not igniting because the
water pressure is too low.|

Refer to the specification for system requirements.
Increase water pressure through the system.
Contact your boiler manufacturer.

Only hot/
cold water
from Shower
Valve

| Inlet water supplies are reversed.|

Check the water inlet connections are the correct way
around: Hot on the left, Cold on the right when viewed from
the front. Rework pipework as necessary.

Filter/pipe blockage|

Flush through pipework and filters to ensure removal of
debris and any airlocks.

Water
dripping
from shower

| This is normal for a short time after using the
shower.|

This is caused by residual water tension, the build up of
water in the shower.

If water continues to drip,
possibly due to the cartridge|

Remove cartridge and clean, refer to ‘Maintenance’ section
before starting any maintenance.

Shower does
not turn on

| Closed isolation valve.|

Open isolation valve.

Mains water supply turned off.|

Turn on mains water supply.

Our Guarantee

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273
where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service- centre/guarantees.

Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l., 14 Rue Strachen
6933 Mensdorf, Luxembourg.

Customer Service: +44330 026 6273
Web: www.bristan.com