beurer NA 20 Nasal Aspirator Instruction Manual

June 3, 2024
Beurer

NA 20 Nasal Aspirator
Instruction Manual

NA 20 Nasal Aspirator

** Read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
Dear customer,**
Thank you for choosing a product from our range Our name stands for high- quality, thoroughly tested products for applications in the areas of heat, gentle therapy, blood  ressure/diagnosis, weight,massage and air,
With kind regards,
Your Beurer team

Included in delivery

Check that the exterior of the delivery cardboard packaging is intact and make sure that all components are present, See device and accessories description, page 22,

  • 1 x nasal aspirator
  • 1 x wide silicone attachment
  • 1 x slim silicone attachment
  • 2 x 1.5 V AA batteries
  • These instructions for use

Getting to know your device

With the new NA 20 nasal aspirator you can gently and effectively remove nasal secretions from infants, toddlers and children (hence- forth referred to as children).
The nasal aspirator can be used again once it has been prepared Preparation involves disinfecting the included silicone attachments, including nasal secretion container,  ubber   eal and valve, as well as the device surface using a conventional disinfectant.
Please note that the entire head unit (including silicone attachments and nasal secretion container) should be replaced if the device is used by more than one person. We  ecommend that you replace the entire head unit after one year. The nasal aspirator has the following features:

  • Easy to use (single-button design)
  • Soft and flexible silicone attachments for safe and comfortable application
  • Powerful motor with a maximum suction pressure of 500 mmHg (66 kPa)
  • Compact design; ideal for use on the move
  • Quiet operation. Can also be used while the child is sleeping
  • Patented backflow prevention – no backflow from the nasal secretion container possible
  • Battery-operated
  • Hygienic: head unit, silicone attachments and nasal secretion container can be removed and cleaned separately. The nasal secretion container and the silicone attachments can be boiled.

Signs and symbols

The following symbols appear in these instructions for use and on the device:

| WARNING Warning notice indicating a risk of injury or damage to health.
---|---
| IMPORTANT Safety note indicating possible damage to the device/accessory.
| Note Note on important information.
| Observe the instructions for use
| Application part, type BF
| Disposal in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE
IP 22| Protected against foreign objects 12,5 mm and against water dripping at an angle
0598| This product satisfies the requirements of the applicable European and national directives.
| Manufacturer
| Permissible storage and transport temperature and humidity
| Permissible operating temperature and humidity
| Dispose of packaging in an environmentally friendly manner

Intended use
The device is designed for using intermittent suction to remove nasal secretion and mucus in children (age 0-12 years) at home environment.

Warnings and safety notes

WARNING

  • Before use, ensure that the device and accessories show no visible damage. If you have any doubts, do not use the device and contact your retailer or the specified Customer Service address.
  • The device is not a substitute for medical consultation and treatment. Always consult your doctor immediately in the event of pain or illness.
  • If the child has a nasal condition, consult your GP before using the device.
  • Do not use the device on people with nosebleeds.
  • Do not use the device on people with acute head, facial or neck injuries
  • Do not use the device on people with coagulation or blood disorders.
  • Only use the device as described in the instructions for use. Failure to observe the warnings can lead to mechanical trauma such as nosebleeds, bleeding of the mucous membrane, discomfort or pain.
  • Do not use excessive force when inserting the silicone attachment into the nose.
  • Please observe the general hygiene measures when using the device.
  • Clean the silicone attachment before each use.
  • If the device does not work properly, stop using it immediately.
  • Should discomfort or pain arise while the device is in operation, stop using it immediately.
  • During operation, ensure that the baby does not hold their breath, close their mouth or swallow their saliva. This could create a vacuum, which can damage the eardrum.
  • This device is not intended for use by children or people withrestricted physical, sensory (egg reduced sensitivity to pain) ormental skills or a lack of experience and/or lack of knowledge,unless they are supervised by a person who is responsible for theirsafety or are instructed by such a person in how to use the device
  • Keep packaging material away from children (risk of suffocation).
  • Do not use any additional parts that are not recommended bythe manufacturer.
  • Never submerge the device in water and do not use it in the bathroom. Under no circumstances may liquid enter the device.
  • Never open the device, modify it or repair it; otherwise proper operation can no longer be guaranteed. Failure to comply with this instruction can be dangerous, and will also invalidate the warranty
  • If the device has been dropped, exposed to high levels of mois ture or suffered any other damage, it must no longer be used. If in doubt, contact Customer Services or the retailer.

IMPORTANT

  • Protect the device from impacts, moisture, dirt, marked temperature fluctuations and direct sunlight. Do not drop the device.
  • If the batteries are empty or you do not intend to use the device for longer periods, remove the batteries from the device. This prvents damage which could occur due to leakage.

WARNING
Notes on handling batteries

  • If your skin or eyes come into contact with battery fluid, rinse the affected area with water and seek medical assistance.
  • Choking hazard! Children could swallow and choke on bat teries. Store batteries out of the reach of children.
  • Observe the plus (+) and minus (–) polarity signs. If a battery has leaked, put on protective gloves and clean the battery comparment with a dry cloth.
  • Protect batteries from excessive heat.
  • Risk of explosion! Do not throw batteries into a fire.
  • Do not charge or short-circuit batteries
  • If the device is not to be used for a relatively long period, take the batteries out of the battery compartment.
  • Use identical or equivalent battery types only.
  • Always replace all batteries at the same time.
  • Do not use rechargeable batteries.
  • Do not disassemble, open or crush the batteries.

Device description

  1. Silicone attachment
  2. Head unit
  3. ON/OFF button ****
  4. Battery compartment
  5. Nasal secretion container
  6. Wide silicone attachment Suitable for removal of solid nasal secretions
  7. Slim silicone attachment Suitable for removal of more liquid nasal secretions

Initial use
Inserting the batteries
In order to use the device, you first need to insert the supplied batteries (2 x 1.5 V AA batteries).

  1. Pull the cover off the battery compartment on the device. Use the notch on the underside of the device to do this. Hold the device vertically to prevent the batteries from falling out.

  2. Insert both batteries into the battery compartment according to the specified polarity (+/-) .

  3. Place the cover back onto the battery compartment until you feel it click into place.

Use
To start treatment, proceed as follows:

  1. Select your desired silicone attachment.

Wide silicone attachment
Suitable for removal of more solid nasal  secretions| Slim silicone attachment
Suitable for removal of more fluid  asal secretions
2. Position the selected silicone attachment onto the tip of the device. Ensure that the silicone attachment is fully placed on the tip of the head unit.

  1. Check that the device is functioning correctly before inserting it into the nose. To do so, briefly press and hold the ON/OFF button

  2. Hold or place the child to be treated in an upright position or in a position where they are leaning slightly back. Do not use the device when the child to be treated is lying down. Carefully guide the tip of the silicone attachment into the nostril or against the nasal septum. The tip of the silicone attachment does not need to be fully inserted into the nose.During the treatment, hold the device at an angle of 20° to 60°  from the face.

  3. Press and hold the ON/OFF button to switch on the device. Now suck the nasal secretions out of the nose. Ensure that no nasal secretions get inside the valve.

  4. Repeat the process as necessary on the other nostril. Should the child experience discomfort or pain, stop using the device immediately. Stop use once the nasal secretion  ontainer is filled up to the “MAX” line, at the latest

  5. To end use, release the ON/OFF button.

  6. Clean the device after every use (see “8. Cleaning and disinfection” on page 25).

Cleaning and disinfection

IMPORTANT
Clean the device after every use, as otherwise it can become clogged and will no longer be able to guarantee smooth, hygienic operation.

  1. Remove the silicone attachment used and the head unit from the device.

  2. Twist the nasal secretion container anti- clockwise (a half rotation). Then pull it down and off.

  3. We also recommend removing the rubber seal (1) as well as the valve (2) from the head unit, so that no bacteria can accumulate there

  4. Clean the silicone attachment, nasal secretion container, rubber seal and valve with hot water and some mild soap. Do not use any harsh cleaning products. To disinfect the silicone attachment and the nasal secretion container, place them in boiling water for 3 to 5 minutes. Contact between the parts and the hot base of the pan should be avoided. Place the individual components subsequent on a dry, clean and absorbent surface and allow to dry completely (for at least 4 hours)

  5. Clean the head unit exclusively with water. Do not use soap or chemical cleaners, as these can clog the tip of the head unit.

  6. Only clean the main device with a clean, dry cloth. Do not use any corrosive cleaning products, solutions or benzenes.The device must not be cleaned with water or submerged in water

  7. Using a dirty or damaged valve can decrease the suction pressure of the nasal aspirator. The valve must be replaced as soon as you notice it is dirty or damaged. Additionally, the valve must be completely dry after cleaning in order for the device to function. The suction power is impaired/non-existent even if there is a small amount of residual moisture remaining

  8. Dry all parts carefully using a soft cloth. Do not reassemble the parts until they are completely dry. Store the device away from sunlight, dust and moisture.

Disposal

Disposal of the device
For environmental reasons, do not dispose of the device in the household waste at the end of its useful
life. Dispose of the device at a suitable local collection or recycling point in your country. Dispose of the device in accordance with EC Directive – WEEE (Waste   lectrical and Electronic Equipment). If you have any questions, please contact the  local authorities responsible for waste disposal.
Disposal of the batteries

  • The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers. You are legally required to dispose of the batteries
  • The codes below are printed on batteries containing harmful substances:

Pb = Battery contains lead
Cd = Battery contains cadmium
Hg = Battery contains mercury

Technical data

Type NA 20
Dimensions (LxWxH) 169 x43 x 75 mm
Weight 138 g (without batteries)
Maximum suction pressure 500 mmHg (66 kPa)
Sound pressure < 75dB (measured at a distance of 30cm)
Material Housing and head unit: ABS Nasal secretion container: PC Silicone

attachment: Silicone
Battery operation| 2 x 1.5 V type AA, Mignon (LR6) Battery life in continuous operation > 90 minutes
Expected service life| 3 years
Operating conditions| Temperature: 16°C to 35°C. (61°F to 95°F).
Humidity: <85%. Ambient pressure: 700 hPa to 1060 hPa.
Storage and trans port conditions| Temperature: -25°C to +55°C (-13°F to 131°F) Humidity: <85%. Ambient pressure: 700 hPa to 1060 hPa

Subject to technical changes.
The serial number is located on the device or in the battery compartment.
This device and its accessories comply with the EU Directive2014/30/EU and the European standard EN 60601-1-2 (in accord ance with CISPR 11, EN 61000-3-2, 61000-3-3, 61000-4-2, 61000-
4-3, 61000-4-4, 61000-4-5, 61000-4-6, 61000-4-8, 61000-4-11) andis subject to particular precautions with regard to electromagnetic compatibility.
The device is suitable for use in all environments listed in these instructions for use, including domestic environments.Please note that portable and mobile HF communication systems may interfere with this device.
Notes on electromagnetic compatibility

  • The device is suitable for use in all environments listed in these instructions for use, including domestic environments
  • The use of the device may be limited in the presence of electromagnetic disturbances. This could result in issues such as error messages or the failure of the display/device
  • Avoid using this device directly next to other devices or stacked on top of other devices, as this could lead to faulty operation. If, however, it is necessary to use the device in the manner stated, this device as well as the other devices must be monitored to ensure they are working properly
  • The use of accessories other than those specified or provided by the manufacturer of this device can lead to an increase in electro- magnetic emissions or a decrease in the device’s electromagnetic immunity; this can result in faulty operation
  • Failure to comply with the above can impair the performance of the device.

Replacement parts and wearing parts

Designation Material REF
Silicone attachments Silicone 95048

Head unit (incl valve, rubber seal, nasal secretion container and silicone attachments)| ABS, PTFE, PC, silicone| 95049

What if there are problems?

Problem/ questions Possible causes Solution
The suction power is impaired/non-existent. Batteries are not inserted
properly. Check whether the batteries have been inserted the correct  way

round.
Batteries are flat.| Replace the batteries and try again.
The grey rubber seal on the lower end of the   ead unit for sealing the nasal secretion container is  missing.| Check whether the grey rubber seal  as been fitted.
The nasal secretion container is not correctly inserted.| Check whether the 3 raised lines on the head unit are in the  same position as those on the nasal secretion container.
The valve still has some residual moisture, even if just a  small  mount, after  cleaning.| Ensure that the valve is completely dry  fter cleaning in order for the device to function

Warranty/service
Further information on the guarantee and guarantee conditions can be found in the guarantee leaflet supplied.
Distributed by:
Beurer GmbH 218 89077 Ulm (Germany)
www.beurer.com 
www.beurer-gesundheitsratgeber.com
www.beurer-healthguide.com
AVITA Corporation
9F No,78, Sec, 1
Kwang-Fu Rd.
San-Chung District
24158 New Taipei City (Taiwan)

Medical Device Safety Service GmbH
Schiffgraben 41,30175 Hannover (Germany)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals