FIRMAN P05703 Gas Start Portable Generator User Guide
- June 3, 2024
- FIRMAN
Table of Contents
FIRMAN P05703 Gas Start Portable Generator
Quick Reference Guide
WARNING This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand the operator’s manual before using this product. All pages references to the operator’s manual.
Unpack Generator
Remove the generator, accessories, Inserts and literature from the carton. i any item Is missing or damaged, contact our product service deparment at 1-844-347-6261.
Included ltems
Install the wheel kit
Slide the axle pin(A) through the wheel(B) and mount point on the frame and
flat washer(D).
Secure them with cotter pin(C).
Attach the support leg (G) to the generator frame with flange bolt (E) (M8X16) and flange lock nut(F) (M8).
Secure handle (K) to the frame using bolt (H) (MBx50) and flange nut (F (M8).
Battery Cable Connection
NOTE: The generator comes equipped with the positive (red) and negative (black) cables already attached to battery terminals.
- Cut wire tie that is binding the black battery cables A and B.
- Insert the male connector of cable A into female connector of cable B.
Add Lubricant and Fuel
- Use a funnel to pour provided engine oil into the engine. Fil to the upper mark of the oil dipstick H.
- Use clean/fresh regular UNLEADED gasoline with a minimum 87 octane.
Start Generator
Move generator outside to a flat, level surface, away from doors, wind ows and vents.
WARNING
Do not overload generator or electrical cords. Consult operation manual.
Tun fuel valve under tank to ON (1) position
Turn engine switch located on control panel to RUN ()position
LFlip the battery switch to the ON (L) position
Remote Start
Push and release the START button
Electic Start
- Move choke lever located on engine to START position
- Flip the engine switch to the START (1I) position
- Move choke lever to RUN Position
Recoll Start
- Move choke lever located on engine to START position
- Pull cord starter to start engine
- Move choke lever to RUN Position
Plug In ltems to be powered, using only grounded extension cords
Shutdown and Storage
-
Remove any load from the generator
-
Push and release the “STOP” button on the remote control.
SKIP THIS STEP, IF YOU ARE NOT USING REMOTE START -
Run the generator at no load for 2 minutes and then turn engine switch to OFF (O) position
-
Flip the battery switch to the OFF O) position
-
Turn fuel valve to OFF (O) Dosition
NOTE
THE BATTERY SWITCH ALWAYS SHOULD BE IN “OFF” (0) POSITION AT THE ENO OF USE TO
PREVENT BATTERY DRAIN.
If generator Is to be stored for longer than 30 days, ralar to The operator’s manual for further Instruction.