tp-link EAP115 Wall Plate EAP Instruction Manual

September 29, 2024
tp-link

EAP115 Wall Plate EAP

“`html

Specifications:

  • Operating Frequencies:

    • EAP115-Wall: 2412MHz – 2472MHz (20dBm)

    • EAP225-Wall / EAP230-Wall / EAP235-Wall / EAP615-Wall: 2412MHz
      – 2472MHz (20dBm), 5150MHz – 5250MHz (23dBm)

    • EAP650-Wall / EAP655-Wall / EAP615GP-Wall / EAP673-Extender:
      2412MHz – 2472MHz (20dBm), 5150MHz – 5250MHz (23dBm), 5250 MHz –
      5350 MHz (23dBm), 5470 MHz – 5725 MHz (30dBm)

Product Usage Instructions:

Safety Information:

  • Keep the device away from water, fire, humidity, or hot
    environments.

  • Do not attempt to disassemble, repair, or modify the device.
    Contact customer service for assistance.

  • Operate the device within the recommended temperature range of
    0°C to 40°C (32°F to 104°F).

Regulatory Compliance:

This product complies with FCC and CE regulations for class B
devices. Users may need to take measures to address radio
interference in domestic environments.

EU Declaration of Conformity:

The device is compliant with essential requirements of EU
directives. Refer to the original EU Declaration of Conformity on
the TP-Link website for more information.

RF Exposure Information:

The device meets EU requirements on limiting public exposure to
electromagnetic fields. Maintain a distance of 20cm between the
device and your body for compliance.

UKCA Mark:

This device is compliant with Radio Equipment Regulations in the
UK and should only be used indoors in Great Britain.

Canadian Compliance Statement:

The equipment complies with IC radiation exposure limits and
should be operated with a minimum distance of 20cm from the
body.

Korea Warning Statements:

Compliance statements specific to Korea are applicable for
certain models. Refer to product documentation for details.

Symbols on the Product Label:

Explanation of symbols found on the product label can be found
in the user manual provided with the device.

FAQ:

Q: Can this device be used outdoors?

A: No, this device is designed for indoor use only. Avoid using
it in outdoor environments to prevent damage or accidents.

Q: What should I do if I encounter radio interference

issues?

A: If you experience radio interference, try adjusting the
placement of the device or consult customer support for further
assistance.

“`

Regulatory Compliance
Wall Plate EAP
© 2024 TP-Link 1910013239 REV1.3.0

For Class B EAP with no adapter:
FCC Compliance Information Statement
Product Name: Omada EAP Model Number: EAP225-Wall / EAP235-Wall / EAP615-Wall / EAP655-Wall / EAP615GP-Wall / EAP673-Extender Responsible party: TP-Link Systems Inc. Address: 10 Mauchly, Irvine, CA 92618 Website: https://www.tp- link.com/us/ Tel: +1 626 333 0234 Fax: +1 909 527 6804 E-mail: sales.usa@tp- link.com This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. · Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. “To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter.” We, TP-Link Systems Inc., has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2024-09-05
CE Mark Warning
This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
OPERATING FREQUENCY (the maximum transmitted power)
For EAP115-Wall: 2412MHz–2472MHz(20dBm) For EAP225-Wall / EAP230-Wall / EAP235-Wall / EAP615-Wall: 2412MHz–2472MHz(20dBm) 5150MHz–5250MHz(23dBm) For EAP650-Wall / EAP655-Wall / EAP615GP-Wall / EAP673-Extender: 2412MHz–2472MHz(20dBm) 5150MHz–5250MHz(23dBm) 5250 MHz -5350 MHz (23dBm) 5470 MHz -5725 MHz (30dBm)
EU Declaration of Conformity
For EAP673-Extender and APs with adapters:

TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/53/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863. For APs without adapters: TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/53/EU, 2011/65/EU and (EU)2015/863. The original EU Declaration of Conformity may be found at https://www.tp-link.com/en/ce.
RF Exposure Information
This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation of exposure of the general public to electromagnetic fields by way of health protection. The device complies with RF specifications when the device used at 20 cm from your body.
National Restrictions
For EAP225-Wall / EAP230-Wall / EAP235-Wall / EAP615-Wall / EAP650-Wall / EAP655-Wall / EAP615GP-Wall / EAP673-Extender: Attention: This device may only be used indoors in all EU member states, EFTA countries and Northern Ireland. Frequency band: 5150 – 5250 MHz: Indoor use: Inside buildings only. Installations and use inside road vehicles and train carriages are not permitted. Limited outdoor use: If used outdoors, equipment shall not be attached to a fixed installation or to the external body of road vehicles, a fixed infrastructure or a fixed outdoor antenna. Use by unmanned aircraft systems (UAS) is limited to within the 5170 – 5250 MHz band. Frequency band: 5250 – 5350 MHz: Indoor use: Inside buildings only. Installations and use in road vehicles, trains and aircraft are not permitted. Outdoor use is not permitted. Frequency band: 5470 – 5725 MHz: Installations and use in road vehicles, trains and aircraft and use for unmanned aircraft systems (UAS) are not permitted.
UKCA Mark

UK Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Radio Equipment Regulations 2017. The original UK Declaration of Conformity may be found at https://www .tp-link.com/support/ukca
National Restrictions
Attention: This device may only be used indoors in Great Britain.
UK
Canadian Compliance Statement
For EAP615-Wall / EAP655-Wall / EAP615GP-Wall / EAP673-Extender: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1) L’appareil ne doit pas produire de brouillage; 2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Caution
For EAP225-Wall / EAP235-Wall / EAP615-Wall / EAP615GP-Wall: 1) The device for operation in the band 5150­5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; 5150 MHz to 5350 MHz is restricted to indoor operations in Hong Kong. For EAP655-Wall / EAP673-Extender: 1) The device for operation in the band 5150­5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; 5150 MHz to 5350 MHz is restricted to indoor operations in Hong Kong. DFS (Dynamic Frequency Selection) products that operate in the bands 5250- 5350 MHz, 54705600MHz, and 5650-5725MHz.

Avertissement
Pour EAP225-Wall / EAP235-Wall / EAP615-Wall / EAP615GP-Wall: 1) Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; Pour EAP655-Wall / EAP673-Extender 1) Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux; Les produits utilisant la technique d’atténuation DFS (sélection dynamique des fréquences) sur les bandes 5250- 5350 MHz, 5470-5600MHz et 5650-5725MHz.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Déclaration d’exposition aux radiations:
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
Industry Canada Statement
CAN ICES-3 (B)/NMB-3(B)
Korea Warning Statements
.
NCC Notice & BSMI Notice

EAP225-Wall / EAP230-Wall / EAP235-Wall / EAP615-Wall / EAP650-Wall / EAP655-Wall / EAP615GP-Wall

.

.

Pb

Cd

Hg

CrVI

PBB

PBDE

PCB

1. “0.1 wt %” “0.01 wt %” . 2.””. 3.”–” .

, .

Safety Information
Keep the device away from water, fire, humidity or hot environments.

Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
Do not use the device where wireless devices are not allowed. Operating Temperature: 0 ~ 40 (32 ~ 104 ) For EAP615GP-Wall / EAP673-Extender:
This product uses radios and other components that emit electromagnetic fields. Electromagnetic fields and magnets may interfere with pacemakers and other implanted medical devices. Always keep the product and its power adapter more than 15 cm (6 inches) away from any pacemakers or other implanted medical devices. If you suspect your product is interfering with your pacemaker or any other implanted medical device, turn off your product and consult your physician for information specific to your medical device.
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.
Explanation of the symbols on the product label
Note: The Equipment marking is at the bottom of the device. Symbols may vary from products. Symbol Explanation Class II equipment
Class II equipment with functional earthing Alternating current Direct current Polarity of d.c. power connector
For indoor use only

Dangerous voltage
Caution, risk of electric shock
Energy efficiency Marking
Protective earth
Earth
Frame or chassis
Functional earthing
Caution, hot surface
Caution
Operator’s manual
Stand-by
“ON”/”OFF” (push-push)
Fuse Fuse is used in neutral N RECYCLING This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment. User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or electronic equipment.

Caution, avoid listening at high volume levels for long periods

Disconnection, all power plugs

m

Switch of mini-gap construction

Switch of micro-gap construction (for US version)

µ

Switch of micro-gap / micro-disconnection construction (for other

versions except US)

Switch without contact gap (Semiconductor switching device)

Mounting Requirements
For safety, we recommend you to use the original screws in the package when mounting. The following are alternatives to mount the device on the wall:
· (For EAP115-Wall / EAP230-Wall) Use a 86 mm/standard EU wall junction box and 2 screws which comply with ANSI B1.1 4# or 6# standard and are longer than 15 mm.
· (For EAP225-Wall / EAP235-Wall) Use a 86 mm/standard EU/standrad US wall junction box and 2­4 screws which comply with ANSI B1.1 4#, 6# or 8# standard and are longer than 8.5 mm.
· (For EAP615-Wall / EAP650-Wall / EAP655-Wall / EAP615GP-Wall) Use a 86 mm/standard EU/standrad US wall junction box and 2­4 screws which comply with ANSI B1.1 4#, 6# or 8# standard and are longer than 10 mm.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals