Xiamen Joint JNT-EVL002 Electric Vehicle AC Charger User Manual
- September 28, 2024
- Xiamen Joint
Table of Contents
Electric Vehicle AC Charger
JNT-EVL002/48AC/01C/BK/RF/WF Series(NA)-User Manual
USER MANUAL
WARNING & CAUTION
1. Important Safety Instructions
1.1 Overall Warnings & Cautions
WARNING: To avoid fire, injury or death, carefully read and follow the
instructions during installation, operation and maintenance.
– DO NOT put fingers into the electric vehicle connector.
– DO NOT use this product if the flexible power cord or EV cable is
frayed, insulation-broken, or any other signs of damage.
– DO NOT use this product if the enclosure or the EV connector is broken,
cracked, open, or shows any other indication of damage.
– DO NOT remove cover or attempt to open the enclosure because of risk of
electric shock.
WARNING: This device should be supervised when used around children.
WARNING: This device must be grounded.
WARNING: To avoid a risk of fire or electric shock, do not use this device with an extension cord.
WARNING: The suitability of the use of flexible cord in accordance with CE code, part I, rule 4-012, is to be determined by the local inspection authority.
WARNING: To reduce the risk of fire, connect only to a circuit provided branch circuit over-current protection in accordance with the CSA C22.1-15 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code (USA).
Circuit Breaker Options table
Output Amperage (A)
| 16A| 32A| 40A| 48A| 70A| 80A
---|---|---|---|---|---|---
Circuit Breaker Options (A)| 20A| 40A| 50A| 60A| 90A|
100A
1.2 Installation Requirements
WARNING: Disconnect electrical power prior to installing the charging station.
WARNING: Be sure to preview the user manual and ensure local building and electrical codes are reviewed before installing the AC charger.
WARNING: The AC charger should be installed by a qualified technician according to the user manual and local safety regulations.
CAUTION: Use appropriate protection when connecting to the main power distribution cable.
CAUTION: Type B, C or D breaker with the rating current for table should be installed in the upstream AC distribution box.
CAUTION: The device shall be mounted at height between 2 feet and 4 feet from ground.
CAUTION: Please keep the charger in a clean area with low humidity. Not recommended to be installed in coastal environments with high humidity or high dust.
1.3 Daily Maintenance
CAUTION: Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger, and notify the professionals to carry out maintenance before next use.
CAUTION: Please use the charger properly. Do not hit or press hard on the enclosure. If it is damaged, please contact a professional technician.
CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials.
CAUTION: Do not put heavy objects on the charger to avoid danger.
2. Product Introductions
CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials.
2.1 Basic Interface
-
LED Light Indication
-
RFID Swipe Area
-
SAE J1772
AC Charging Connector -
Rear AC Power Inlet
-
AC Power Inlet
-
LAN Cable Inlet
-
Charging Cable Inlet
-
Rear Notch
2.2 Dimensions
2.3 Specifications
JNT-EVL002/48AC/01C/BK/RF/WF
POWER
Input Rating|
208~240V AC
Output Current & Power|
9.6KW (40A)
|
11.5 kW (48A)
Power Wiring|
L1 / L2 / GND
Input Cord|
NEMA14-50 Plug
|
Hard-wire
Mains frequency|
50 / 60 Hz
Connector Type|
SAEJ1772 Type1 18ft (25ft optional)
Ground Fault Detection|
CCID 20
Protection|
UVP, OVP, RCD (CCID 20), SPD, Ground Fault Protection, OCP, OTP, Control Pilot Fault Protection
USER INTERFACE
Status Indication|
LED indication
User Interface|
L-Charge APP
Connectivity|
Bluetooth, Wi-Fi (2.4G), Ethernet
User Authentication|
Plug & Charge, RFID Card, APP
Card Reader|
RFID, ISO14443A, ISO14443B, 13.56MHz
Software Update|
OTA
CERTIFICATION & STANDARDS
Safety & Compliance|
UL991, UL1998, UL 2231, UL2594
Certification|
ETL / FCC / Energy Star
Warranty|
36 months
GENERAL
Color|
White, Black (Customizable)
Enclosure Rating|
NEMA 4 (IP65), IK08
Operating Altitude|
<6561ft(2000m)
Operating Temperature|
-22°F ~ +122°F (-30°C ~ +50°C)
Storage Temperature|
-40°F ~ +185°F (-40°C ~ +85°C)
Operating Humidity|
5~95%
Mounting|
Wall mount / Pedestal (optional)
Product Dimensions|
11.7″ × 8.2″ × 3.96″ (297.2 × 208.3 × 100.58mm)
3. Verify Contents
Ensure you have this installation guide and these parts:
AC Charger ×1 User Manual ×1
Wall-Mounted Bracket ×1 M4 Anti-Theft Round Head Screws ×1
M6 Hexagonal Expansion Screws ×4 Allen Wrench ×1
Mounting Template ×1 RFID Card ×2
Cable Ramp ×1 ST3.5*16 Screws ×2
M32 Conduit Fitting ×1 AD34.5 Conduit Fitting (Optional) ×1
4. Gather Tools
Tools required before installing the Wall-Mounted charger, gather the following tools:
- Wire stripper
- Adjustable Wrench
- Voltmeter or digital multi-meter (for measuring AC voltage at the installation site)
- Level
- Pencil or marker
- Drill
- Phillips screwdriver
(1) (2) (3)
(4) (5) (6) (7)
Note: The above tools are very important, please gather them all.
5. Plan The Mounting
WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight.
CAUTION: Not recommended to be installed in coastal environments with high humidity or high dust.
Select the appropriate mounting location with electrical capacity:
I. Ensure the owner has chosen a mounting location that allows the charging
cable to reach the car’s charging port while still providing slack.
II. The device must be anchored into mounting such as 3.14″ x 5.11″ stud or a
solid wall.
6. Wall mounting
STEP 1
Make sure the installation wall is vertical, and use the Mounting template to drill four screw holes with a diameter of 0.33″(8.5mm) and a depth of 2.17″~2.36″(55mm~60mm) at a height of 47.24″~51.18″(1200-1300mm) from the ground according to the hole positions.
- Ground
STEP 2
Push the bracket down to remove the wall hanger.
STEP 3
Use 4 Hexagonal Expansion Screws to secure the wall-mounted bracket on the wall, Use an wrench to tighten the screw nuts on the expansion screws.
STEP 4
Align the rear notch of charger with the wall-mounted bracket and alignment the screw holes at the bottom, and secure it using M4 Anti-Theft Round Head Screws.
STEP 5
Overall outlook picture after installation:
Wall-mounted cable winding Plug holder(optional)
Pedestal(optional)
7. Wire The Circuit
WARNING: This device must be grounded. Disconnect electrical power prior to installing the charging station.
WARNING: Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or serviceman if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product if it doesn’t fit the outlet, have a proper outlet installed by a qualified electrician.
CAUTION: Use appropriate protection when connecting to the main power distribution cable.
This step is only to Hard-wire wiring and requires user-supplied AC input cables.
For safe use of electricity, please set circuit breaker protection in the input part of EV Charger.
Circuit Breaker Options table
Output Amperage (A)
| 16A| 32A| 40A| 48A| 70A| 80A
---|---|---|---|---|---|---
Circuit Breaker Options (A)| 20A| 40A| 50A| 60A| 90A|
100A
STEP 1
Use a allen wrench to loosen the two screws located at the bottom of the charging station. press down on the front cover and slide it down, remove the front cover.
STEP 2
Remove the cover from the charger using the appropriate tools (such as coin).
- COIN
STEP 3
Remove the waterproof plug from the charger cable inlet, Connect and Lock the M32 Conduit Fitting Part1 and Part2 (including the washer) to the Inlet as shown below.
Note:
- You need to bring your own AC input cable.
- Select the AD34.5 or M32 Conduit Fitting based on the AC input cable type, If you use AD34.5 Conduit Fitting, perform the same steps as above.
STEP 4
Take out the AC input cable and strip the TPU cover by 5.52″ (140mm), and then strip individual wires by 0.47″ (12mm). use ferrules on stranded wires and press it by wire crimper.
(ferrules)
STEP 5
First, pass the AC input cable through the M32 Conduit Fitting Part 3 ( (3) ), then continue through Part 1 and Part 2. Connect the wires (L1, L2, GND) and tighten each connector screw to 2 N.m (17.7 in.lbs).
STEP 6
Lock the M32 Conduit Fitting Part 3 ( (3) ), Press the AC input cable with cable ramp and secure it with two screws (3.5*16).
STEP 7
If you use Ethernet networking, you can plug the Ethernet cable into the RJ45 port.
STEP 8
Align the cover with its position on the charging station. Secure the cover in place using the appropriate tools (such as coin).
- COIN
STEP 9
Align the upper slot of the charger with the front cover, press the front cover upward, align with the bottom hole, and fix the screw.
8. Light Codes
8.1 After Start UP
Device Status
| Light Codes
---|---
Power On|
Blue, green and red run clockwise
Standby
| Solid Blue
Plug The Charging Connector|
Solid Green
Swipe Card
| Green Blinking
Charging In Progress|
Green Breathing
Finished / Stopped Charging
| Solid Green
Reservation Charging|
Blue, green and red blinking alternately
OTA
| Blue Breathing
Device Unavailable|
Blue Blinking
Fault
|
Red
8.2 Error and Warning Messages
No.
| Fault Status| Red Light| Remark
---|---|---|---
1| Meter Fault| 1 flash followed by 3 sec pause|
Auto Recover
2
| CP Fault| 2 flashes followed by 3 sec pause| Unplug the Connector to Recover
3| UVP| 3 flashes followed by 3 sec pause|
Auto Recover
4
| OVP| 4 flashes followed by 3 sec pause| Auto Recover
5| OTP| 5 flashes followed by 3 sec pause|
Auto Recover
6
| OCP| 6 flashes followed by 3 sec pause| Unplug the Connector to Recover
7| Ground Fault| 7 flashes followed by 3 sec pause|
Unplug the Connector to Recover
8
| Relay Fault| 8 flashes followed by 3 sec pause| Unplug the Connector to
Recover
9| RCD Abnormal| 9 flashes followed by 3 sec pause|
Unplug the Connector to Recover
10
| RCD Self-Test Fault| 10 flashes followed by 3 sec pause| Reboot to Recover
11| Relay Self-Test Fault| 11 flashes followed by 3 sec pause|
Reboot to Recover
9. FCC Declaration
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference, and this device must accept
any interference received, including interference that may cause undesired
operation.
Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WIFI module: Containing FCC ID: 2AC7Z-ESP32WROOM32U
To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended.
10. Warranty and Maintenance
- The warranty period for this charger is three years.
- During the warranty period for any malfunction under normal use according to the User Manual (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms:
- The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product.
- Those who are unable to provide valid proof of purchase.
- Those who exceed the manufacturer’s specified warranty period.
- Those who damage the product due to not following the product service instruction for use, maintenance and storage.
- Damage or malfunction caused by external object entering.
- Unauthorized repair, disassembly or modification.
- Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.).
- Malfunction and damage caused by other unavoidable external factors. Malfunction and damage caused by improper use of equipment, such as water or other solutions entering into the equipment.
- Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment.
The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reasonableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages.
Version 1
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>