Mastercool 1200 CFM Blower Fan Heater Instruction Manual

September 27, 2024
Mastercool

1200 CFM Blower Fan Heater

“`html

Specifications:

  • 1200 CFM Blower Fan
  • 300 CFM Blower Fan
  • Heater Attachment for 300 CFM Blower Fan

Product Information:

The product includes a 1200 CFM Blower Fan, a 300 CFM Blower
Fan, and a Heater Attachment designed for use with the 300 CFM
Blower Fan. The blower fans are powerful tools for circulating air
in various work environments, while the heater attachment provides
additional warmth when connected to the 300 CFM Blower Fan.

Blower Fan Usage Instructions:

  1. Always inspect the work area before use and avoid using the
    blower fan near water or in damp conditions.

  2. Avoid operating the blower fan near flammable liquids or
    areas.

  3. Ensure unrestricted airflow to and from the unit to prevent
    damage.

  4. Wear safety glasses during operation, and consider using a dust
    mask in dusty environments.

  5. Maintain the power cord, avoid pulling it to unplug, and check
    for damage before each use.

  6. Secure the unit in stable environments and refrain from placing
    objects into the air intake or discharge grill.

  7. Regularly maintain the motor, air blower, and blower wheel for
    optimal performance.

  8. Disconnect the power cord before servicing or when not in
    use.

  9. Prior to use, inspect the unit for any damage and repair if
    necessary.

  10. Use appropriate receptacles based on device ratings and avoid
    running cords under carpets or rugs.

Heater Attachment Usage Instructions:

  1. Read all instructions before using the heater attachment with
    the 300 CFM Blower Fan.

  2. Avoid direct skin contact with hot surfaces and keep
    combustible materials at least 3 feet away from the heater.

  3. Exercise caution when children or disabled individuals are
    present around the heater.

  4. Always unplug the heater when not in use and never operate it
    with a damaged cord or plug.

  5. Do not use the heater outdoors or in wet indoor locations such
    as bathrooms.

  6. Connect the heater to properly grounded outlets only.

  7. Avoid inserting foreign objects into ventilation or exhaust
    openings.

FAQ:

Q: Can I use the Heater Attachment with the 1200 CFM Blower

Fan?

A: No, the Heater Attachment is specifically designed for use
with the 300 CFM Blower Fan only.

Q: How often should I clean the blower fan for optimal

performance?

A: It is recommended to clean the motor, air blower, and blower
wheel regularly as per the maintenance instructions provided.

“`

INSTRUCTION MANUAL
1200 CFM BLOWER FAN 300 CFM BLOWER FAN HEATER ATTACHMENT FOR 300 CFM BLOWER FAN
1200 CFM Blower Fan
300 CFM Blower Fan

Heater Attachment for 300 CFM Blower Fan

1200 CFM BLOWER FAN
· 120 volts, 60 Hz · Rated power: 2.0 amp · Moves air up to: 1200 CFM · For indoor or outdoor use · 3 speed switch
(high, medium, low) · Built-in overload protection · (2 pcs) 11 amp built-in
grounded receptacles · Housing material: impact
resistant ABS · 8.5 ft cord length, SJTW
14AWG · 4-position adjustment feet

300 CFM BLOWER FAN
· 120 volts, 60 Hz · Rated power: 1.0 amp · Moves air up to: 300 CFM · For indoor or outdoor use · 3 speed switch
(high, medium, low) · Built-in overload protection · (2 pcs) 11 amp built-in
grounded receptacles · Housing material: impact
resistant ABS · 8.5 ft cord length, SJTW
14AWG · 4-position adjustment feet

HEATER ATTACHMENT FOR 300 CFM BLOWER FAN
· 1320 watts, 120 volts · 11 amps, 5000 BTU · Converts blower into a heater · Clips securely onto the front
of the blower and plugs into one of the outlets on the side of the blower · 16 AWG SJT cord, grounded plug · For indoor use only

1

WARNING! BLOWER FAN: 1. Always look over the work area prior to use. Never use near or in water. Do not use in damp
or wet work areas.
2. Never use near flammable liquids or areas.
3. Do not restrict the flow of air to or from the unit, as you may cause damage to the unit.
4. Always wear safety glasses when operating the blower fan. In dusty areas a dust mask or respirator, may be necessary.
5. Always maintain the power cord. Do not unplug the unit by pulling on the cord. Always check the power cord for damage prior to use.
6. Always secure the unit if using it in an unstable environment.
7. Never place any tool or object into the air intake or the discharge grill.
8. Always maintain the unit. For optimum performance keep the motor, air blower and blower wheel clean. See maintenance instructions for proper cleaning procedure.
9. Always disconnect the power cord prior to servicing and when not in use.
10. Always inspect the unit prior to use. Check the motor, air blower, power and housing of the unit for any possible damage. If found, repair the affected area prior to use.
11. Never use 15 amp receptacle with a device that is rated higher than 15 amps.
12. Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners, or the like. Arrange the cord away from traffic area where it may be tripped over.
13. Failure to read and follow these warnings may result in serious injury.
WARNING! HEATER: THIS HEATER IS DESIGNED FOR USE WITH THE 300 CFM BLOWER FAN ONLY When using electrical appliance, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to a person, including the following: 1. Read all instructions before using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Use the blower handle to move the heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet from the front of the heater and keep them away from the side and the rear of the heater.
3. Extreme caution is necessary when any heater is used by or near children or disabled personnel and whenever the heater is left operating and unattended.
4. Always unplug heater when not in use.
5. Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped, or damaged in any manner. Return the heater to our service center for examination, electrical or mechanical adjustments, or repair.
6. Do not use outdoors.
7. This heater is not intended for use in bathrooms, and similar wet indoor locations. Never locate heater where it may fall into a bathtub or other water container.
8. Connect to properly grounded outlets only.
2

9. Do not insert or allow foreign objects to enter any ventilation or exhaust openings as this may cause an electrical shock or fire, or damage the heater.
10. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may be blocked.
11. A heater has hot, arcing, or sparking parts inside. Do not use it in areas where gasoline, paint, flammable liquids, fumes or dusts are used or stored.
12. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
13. Avoid the use of extension cords because the extension cord may overheat and cause a risk of fire.
14. Allow the heater to cool before turning off the blower. 15. SAVE THESE INSTRUCTIONS
HEATER ATTACHMENT OPERATION INSTRUCTIONS: Only attach heater to 300 CFM Blower Fan unit. Slide the heater over the blower outlet and secure the spring clip to the blower catch. The fit should be tight with no gaps.
TO OPERATE: Plug the heater power cord into the blower receptacle. TURN THE BLOWER ON FIRST and then turn on the heater with the lighted On-Off switch. When the switch is lit, the power is applied to the heater.
TO SHUT OFF: TURN THE HEATER OFF FIRST and then wait a few minutes before turning off the blower. This allows the heater to cool down and extends the life of the heater unit.
TO DISCONNECT: To disconnect the heater, turn the heater control to off. Remove the heater plug from the blower receptacle and uncouple the heater from the blower outlet.
CONTROLS: 1. Lighted On-Off Switch: Lit when power is applied to the heater. 2. Air Switch: Provides an interlock so the heater can only be operated after being mounted on
a blower and the blower is normally operating. 3. Internal Thermostat: An internal thermostat has been provided to maintain that the heater
temperatures are within normal operating ranges. 4. Power Indicator Light: Lit when the heater is normally operating. 5. Internal Thermal Fuse: If the thermostat should fail or the temperature of the heater starts to
reach a hazardous range, a one time thermal fuse protects against hazardous overthermostat conditions. This fuse is set to trip above the thermostat set point and is a factory replaceable item.
3

HEATER ATTACHMENT MAINTENANCE INSTRUCTIONS TO CLEAN: 1. Always unplug and disconnect the heater from blower before cleaning.
2. Use a soft cloth moistened with a mild soap solution for the case.
3. Use a soft brush to clean the screens.
4. NEVER IMMERSE the heater in water, or allow water to drip into the heater housing. NEVER use gasoline, benzene, thinners, or similar materials to clean the heater. They will damage the heater and could cause a fire or explosion.
HEATER ATTACHMENT GROUNDING INSTRUCTIONS This heater is for use on 120 volts. The cord has a plug and is intended for insertion into the receptacle on the 300 CFM fan blower case only. The blower has a similar configured plug. Use only with a properly grounded receptacle.

For parts or service contact the service department: 1-888-825-6989