Product Information: HID Long Range Reader
Specifications:
- Model: HID Long Range Reader
- Connection: Wiegand Converter Box
- Terminal Descriptions:
- P1-1 Beeper Input (BEEP)
- P1-2 LED Input (GRN)
- P1-3 Ground (GND)
- P1-4 +VDC
- P1-5 Unused (DRAIN)
- P1-6 LED Input (RED)
- P1-7 Hold Input (HOLD)
Product Usage Instructions:
Wiring Connection:
The HID Long Range Reader connects to an indicator through a
Wiegand Converter Box.
Wiring Schematic:
Refer to Figure 1 for the HID Long Range Reader Wiring
Schematic.
Reader Connections:
Wiegand Terminal | HID Terminal | Description |
---|---|---|
P2-1 | GPIO4 | RS485-Y / TXA |
Wiegand Converter Box Wiring:
For detailed wiring connections, refer to Figure 3 of the
manual.
FAQs:
Q: How do I connect the HID Long Range Reader to power?
A: Connect the HID READER to a customer-supplied 120 VAC power
source as shown in the wiring diagram.
“`
HID Long Range Reader
Wiring Connection Addendum
The HID Long Range Reader connects to an indicator through a Wiegand Converter
Box.
INDICATOR RS-232
WIEGAND CONVERTER BOX Figure 3 on page 2
Figure 1. HID Long Range Reader Wiring Schematic
HID LONG RANGE READER
Table 1
HID Terminal
Description
P1-1 Beeper Input (BEEP) P1-2 LED Input (GRN P1-3 Ground (GND)
P1-4 +VDC
P1-5 Unused (DRAIN) P1-6 LED Input (RED) P1-7 Hold Input (HOLD)
Wiegand Terminal
HID Terminal
Description
GND +V –
P2-1 GPIO4 (RS485-Y / TXA) P2-2 GPIO3 (RS485-Z / TXB) P2-3 Wiegand Data 0 / Data (DATA0/DATA) P2-4 Wiegand Data 1 / Clock (DATA1/CLK) P2-5 Open Collector Output / Tamper (OC/TMPR) P2-6 GPIO2 (RS485 – RX8) P2-7 GPIO1 (RS485-RXA)
Table 1. HID Long Reader Connections
Wiegand Terminal
DATA 0 DATA 1 –
September 18, 2024
1
2
P2
3 4
5
6
7
1
2
P1
3 4
5
6
7
Figure 2. HID Long Range Reader Wiring
PN 225932 Rev A
HID Long Range Reader Wiring Connections
CUSTOMER SUPPLIED 120 VAC
GROUND HOT
NEUTRAL
HID READER
RS-232 COMMUNICATIONS
+V GND
DATA 1 DATA 0
RX GND
10
Figure 3. Wiegand Converter Box Wiring Diagram