ignition Co6 V2 IP65 270W RGBW LED Flood RGBW Owner’s Manual
- September 27, 2024
- ignition
Table of Contents
Co6 V2 IP65 270W RGBW LED Flood RGBW
Product Information
Specifications
-
Product Name: Co6 V2 LED Flood IP65 270W RGBW LED
Floodlight -
Model: Co6 V2
-
IP Rating: IP65
-
Power: 270W
-
Color: RGBW
Product Usage Instructions
Safety Instructions
Intended Use: The Co6 V2 LED Flood IP65 270W
RGBW LED Floodlight is designed for professional use as an
electronic lighting effect using LED technology. It is not suitable
for household use. Follow the instructions in the user manual to
prevent personal injury or property damage.
Operating Life: To extend the operating life of
the device, take regular breaks and avoid frequent switching on and
off. Do not use the device for continuous operation.
Safety Precautions: Ensure safety by using a
proper insulated triple-core mains cable with a safety plug. Do not
modify the cable or plug. In case of isolation damage, disconnect
the power supply immediately and seek repair from a qualified
electrician.
FAQ (Frequently Asked Questions)
Q: Can this LED floodlight be used in households?
A: No, the Co6 V2 LED Flood IP65 270W RGBW LED
Floodlight is designed for professional use and is not suitable for
households.
Q: What should I do in case of isolation damage to the mains
cable?
A: In case of isolation damage, disconnect the
power supply immediately and arrange for repair by a qualified
electrician. Do not use the device until it has been repaired.
Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
User Manual
Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0)
9546 9223-0 Internet: www.thomann.de
13.09.2024, ID: 477575 (V3)
Table of contents
Table of contents
1 General information……………………………………………………………………………………………….. 5 1.1 Symbols and
signal words………………………………………………………………………………. 5
2 Safety instructions………………………………………………………………………………………………….. 6 3
Features……………………………………………………………………………………………………………………… 8 4
Installation………………………………………………………………………………………………………………… 9 5 Starting
up………………………………………………………………………………………………………………. 11 6 Connections and
controls…………………………………………………………………………………… 12 7
Operating………………………………………………………………………………………………………………… 13
7.1 Starting the device…………………………………………………………………………………………. 13 7.2 Main
menu………………………………………………………………………………………………………. 13 7.2.1 “DMX”
mode…………………………………………………………………………………………………. 17 7.2.2 “Slave”
mode………………………………………………………………………………………………… 17 7.2.3 “Stand-alone”
mode……………………………………………………………………………………. 18 7.3 Menu
overview……………………………………………………………………………………………….. 18 7.4 Functions in 2-channel
DMX mode……………………………………………………………… 19 7.5 Functions in 3-channel DMX mode
1………………………………………………………….. 19 7.6 Functions in 3-channel DMX mode
2………………………………………………………….. 20 7.7 Functions in 4-channel DMX
mode……………………………………………………………… 20 7.8 Functions in 6-channel DMX
mode……………………………………………………………… 21 7.9 Functions in 12-channel DMX
mode…………………………………………………………… 21 7.10 Functions in 14-channel DMX
mode…………………………………………………………. 21 7.11 Functions in 26-channel DMX
mode…………………………………………………………. 24 8 Technical
specifications………………………………………………………………………………………. 27 9 Plug and connection
assignments……………………………………………………………………. 28 10
Troubleshooting……………………………………………………………………………………………………. 29 11
Cleaning…………………………………………………………………………………………………………………… 30 12 Protecting the
environment………………………………………………………………………………. 31
3 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
4 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
General information
1 General information
This document contains important instructions for the safe operation of the
product. Read and follow the safety instructions and all other instructions.
Keep the document for future reference. Make sure that it is available to all
those using the product. If you sell the product to another user, be sure that
they also receive this document.
Our products and documentation are subject to a process of continuous develop-
ment. They are therefore subject to change. Please refer to the latest version
of the documentation, which is ready for download under www.thomann.de.
1.1 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal words that are used in this document.
Signal word DANGER!
WARNING!
NOTICE!
Meaning
This combination of symbol and signal word indicates an immediate dangerous
situation that will result in death or serious injury if it is not avoided.
This combination of symbol and signal word indicates a possible dangerous
situation that can result in death or serious injury if it is not avoided.
This combination of symbol and signal word indicates a possible dangerous
situation that can result in mate- rial and environmental damage if it is not
avoided.
Warning signs
Type of danger Warning high-voltage.
Warning dangerous optical radiation.
Warning suspended load.
Warning danger zone.
5 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Safety instructions
2 Safety instructions
Intended use
This device is intended for use as an electronic lighting effect by means of
LED tech- nology. The device is designed for professional use only and is not
suitable for use in households. Use the device only as described in this user
manual. Any other use or use under other operating conditions is considered to
be improper and may result in personal injury or property damage. No liability
will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial,
and intel- lectual abilities and having corresponding knowledge and
experience. Other persons may use this device only if they are supervised or
instructed by a person who is responsible for their safety.
Extend the operating life of the device by regular breaks and by avoiding frequent switching on and off. The device is not suitable for continuous operation.
Safety
DANGER! Risk of injury and choking hazard for children! Children can suffocate
on packaging material and small parts. Children can injure themselves when
handling the device. Never allow children to play with the packaging material
and the device. Always store packaging material out of the reach of babies and
small children. Always dispose of packaging material properly when it is not
in use. Never allow children to use the device without supervision. Keep small
parts away from children and make sure that the device does not shed any small
parts (such knobs) that children could play with.
DANGER! Danger to life due to electric current! A short circuit could lead to
a fire hazard and risk of death. Always use proper ready-made insulated
triple-core mains cable with a safety plug. Do not modify the mains cable or
the plug. In case of isolation damage, disconnect immediately the power supply
and arrange repair. If in doubt, seek advice from a qualified electrician.
DANGER! Danger to life due to electric current! Within the device there are
areas where high voltages may be present. Never remove any covers. There are
no user-serviceable parts inside. Do not use the device when covers, safety
equipment or optical components are missing or damaged.
WARNING! Risk of eye damage caused by high light intensity! The device
generates highly intense light radiation. Looking directly into the light
source can damage the eyes. Never look directly into the light source.
WARNING! Risk of epileptic fit due to flashing lights! The device emits
flashing lights (strobe effects). Flashing lights can trigger epileptic fits
in specific people. If you are at risk of epilepsy, avoid spending longer
periods of time subjected to flashing lights and looking into strobing light.
WARNING! Risk of injury from falling spotlights and barn doors that were
inadequately secured! If spotlights and barn doors are not properly secured
when mounted, they can cause severe injury and considerable damage by falling.
When installing and operating, make sure to follow the standards and
regulations that apply in your country. Always secure spotlights with a
secondary safety attachment, such as a safety cable or a safety chain. Always
secure the barn door with a safety cable on the spotlight. The safety cable
must run outside the barn door to not interfere with the light emission.
NOTICE! Risk of fire due to covered vents and neighbouring heat sources! If
the vents of the device are covered or the device is operated in the immediate
vicinity of other heat sources, the device can overheat and burst into flames.
Never cover the device or the vents. Do not install the device in the
immediate vicinity of other heat sources. Never operate the device in the
immediate vicinity of naked flames.
6 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Safety instructions
NOTICE! Risk of overheating and risk of fire when operated with closed barn
doors! If the spotlight is operated with the barn doors closed, there is a
risk of overheating and fire. In addition, even short-term opera- tion with
the barn doors closed can reduce the service life of the LEDs. Operate the
device only with open barn doors. NOTICE! Damage to the device due to high
voltages! The device can be damaged if it is operated with the incorrect
voltage or if high voltage peaks occur. In the worst case, excess voltages can
also cause a risk of injury and fires. Make sure that the voltage
specification on the device matches the local power grid before plugging in
the device. Only operate the device from professionally installed mains
sockets that are protected by a residual current circuit breaker (FI). Ensure
that the power cord plug is easily accessible at all times if it is the only
device to safely disconnect the device from the mains supply. As a precaution,
disconnect the device from the power grid when storms are approaching or it
the device will not be used for a longer period. NOTICE! Risk of fire by
exceeding the maximum current! The device can supply power to other devices of
identical design and connected in series. If too many devices are connected,
the maximum permitted power consumption can be exceeded, which can cause the
device to overheat and burst into flames. Only connect devices of identical
design to the device. When deciding how many devices you can connect in
series, make sure that the maximum output current specified on the device and
in the “Technical specifications” chapter of the user manual is not exceeded.
Only use power cords with a cable cross-section designed for the required
current intensity when connecting the devices in series. NOTICE! Possible
staining due to plasticiser in rubber feet! The plasticiser contained in the
rubber feet of this product may react with the coating of the floor and cause
permanent dark stains after some time. If necessary, use a suitable mat or
felt slide to prevent direct contact between the device’s rubber feet and the
floor.
7 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Features
3 Features
Information about protection class IP65
Special features of the device:
n 18 × RGBW LEDs (15 W each) n Three separately controllable LED rows n
Operation in stand-alone and DMX mode (7 different modes) n Simple operation
via display and buttons on the device n Pre-programmed automatic shows n
Automatic colour gradients n Selectable dimmer curves n Selectable repetition
frequency up to 25 kHz n Master/slave mode n Robust aluminium housing n Due to
International Protection Rating IP65, temporary outdoor operation is also
possible n W-DMX module for wireless DMX control n Barn doors, diffusion
filter and one omega bracket included
For technological reasons, the light output of LEDs decreases over their
lifetime. This effect increases with higher operating temperature. You can
extend the service life of the illuminants by providing adequate ventilation
and operating the LEDs with the lowest possible brightness.
Equipment with protection class IP65 are dust-tight and completely protected
against contact (first code number). They are also protected against splash
water from any angle (second code digit). That is why this equipment can also
be used out- doors. Event technology equipment is generally only designed for
temporary use however (event lighting) and not for permanent use outdoors.
The specified protection class does not make a statement about the weather
resist- ance of the equipment (resistance to changing ambient conditions as
well as against the effects of sunlight and UV rays).
The seals and screw connections of the equipment must be checked regularly to
ensure a fault-free operation. In cases of doubt, consult a specialist
workshop in due time.
8 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
4 Installation
Installation
Unpack and check carefully there is no transportation damage before using the
unit. Keep the equipment packaging. To fully protect the product against
vibration, dust and moisture during transportation or storage use the original
packaging or your own packaging material suitable for transport or storage,
respectively.
WARNING! Risk of injury from falling spotlights and barn doors that were inad-
equately secured! If spotlights and barn doors are not properly secured when
mounted, they can cause severe injury and considerable damage by falling. When
installing and operating, make sure to follow the standards and regulations
that apply in your country. Always secure spotlights with a secondary safety
attachment, such as a safety cable or a safety chain. Always secure the barn
door with a safety cable on the spotlight. The safety cable must run outside
the barn door to not interfere with the light emission.
NOTICE! Data transfer errors due to improper wiring! If the DMX connections
are wired incorrectly, this can cause errors during the data transfer. Do not
connect the DMX input and output to audio devices, e.g. mixers or amplifiers.
Use special DMX cables for the wiring instead of normal microphone cables.
NOTICE! Risk of overheating and fire due to inadequate distance and bad
ventilation! If the distance between the light source and the illuminated
surface is too short or the device is badly ventilated, the device can
overheat and cause fires. Make sure that illuminated surfaces are more than 2
m away. Do not operate the device in ambient temperatures above 40 °C. Always
ensure sufficient ventilation at the operating location.
NOTICE! Risk of overheating and risk of fire when operated with closed barn
doors! If the spotlight is operated with the barn doors closed, there is a
risk of overheating and fire. In addition, even short-term operation with the
barn doors closed can reduce the service life of the LEDs. Operate the device
only with open barn doors.
9 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Installation
Mounting options
NOTICE! Potential property damage due to unsuitable stands! If the device is
mounted on an unsuitable stand, there is a risk that the stand will fall over
and cause damage.
Only use stands whose maximum bearing capacity is at least as high as the
weight of the device. Always ensure that the stand is stable.
You can install the device in hanging or standing positions. When in use, the
device must always be attached to a solid surface or an approved mount.
Lift the device only at its base. Lifting it via the spotlight head may result
in damage to the device.
The quick lock openings on the bottom of the housing are used for secure
attach- ment of the supplied omega bracket. This is where the flight adapters
are attached. The safety cable must be threaded through the cut-outs on the
bottom of the housing.
Always work from a stable platform whenever installing, moving or servicing
the device. While you do this, the area underneath the device must be cordoned
off.
ö
1 Openings for safety cable 2 Quick-lock openings for omega bracket
Please note that this device must not be connected to a dimmer.
10 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
5 Starting up
Connections in DMX mode
Starting up
Create all connections while the device is off. Use the shortest possible
high-quality cables for all connections. Take care when running the cables to
prevent tripping hazards.
Connect the DMX input of the device to the DMX output of a DMX controller or
another DMX device. Connect the output of the first DMX device to the input of
the second one, and so on to form a daisy chain. Always ensure that the output
of the last DMX device in the daisy chain is terminated with a resistor (110 ,
¼ W).
Connections in Master / Slave
mode
When you configure a group of devices in `Master / Slave’ mode, the first unit will control the others. This feature is especially useful to start a show without much pro- gramming. Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the DMX output of the first slave unit to the DMX input of the second slave unit and so on.
11 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Connections and controls
6 Connections and controls
ö #
$ &
%
1 Adjustable LED panel 2 Locking screw for the LED panel 3 Radio antenna 4
[W-DMX LED] | LED indicates whether wireless control via DMX is activated. 5
Control panel with display membrane button
[MODE] | Activates the main menu and toggles between menu items. Closes an
open submenu. [UP] | Navigates upwards in a menu list. Increases the displayed
value by one. [DOWN] | Navigates downwards in a menu list. Decreases the
displayed value by one. [ENTER] | Selects an option of the respective
operating mode. Confirms the set value.
Rear panel
ö
%
$
100-240V~50/60Hz PUSH
1 [POWER IN] | Lockable panel plug (Power Twist TR1 IP65, male) for the power supply of the device 2 [POWER OUT] | Lockable panel socket (Power Twist TR1 IP65, female) for the power supply of a further device 3 [DMX OUT] | DMX output (3-pin XLR panel socket, IP65 design) 4 [DMX IN] | DMX input (3-pin XLR panel plug, IP65 design)
12 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Operating
7 Operating
7.1 Starting the device
Connect the device to the mains to start operation. After a few seconds, the
display indicates that a reset is in progress. The device is now operational.
The display shows the operating mode that was selected before the device was
switched off.
If the DMX mode is set without a DMX signal being present, the display
flashes.
7.2 Main menu
1. If the display is in standby, unlock it: Press [UP], [DOWN], [UP], [DOWN]
and then [ENTER].
2. Press [MODE] to activate the main menu. 3. Press [UP] or [DOWN] to select
a submenu. 4. When the display shows the required submenu, confirm with
[ENTER]. 5. To close the main menu, press [MODE].
If you do not press any key for about 30 seconds, the main menu will be
reactivated automatically. All previous settings are retained even when you
disconnect the device from the power grid. To restart with the default values,
use the `Factory Reset’ function.
The following table shows the setting options in the menu:
Main menu
DMX Address’
MODE’
Menu level 2 Meaning Set DMX address’
DMX Signal Select’ DMX Mode’
Slave’
Menu level 3
Menu level 4
001…512
Setting the DMX address
Selection of the DMX transmission type
`DMX’
DMX via cable
`Wireless DMX’
DMX via radio transmission
Selecting a DMX mode
`DMX 2Ch’
2-channel DMX mode
`DMX 3Ch1′
3-channel DMX mode 1
`DMX 3Ch2′
3-channel DMX mode 2
`DMX 4Ch’
4-channel DMX mode
`DMX 6Ch’
6-channel DMX mode
`DMX 12Ch’
12-channel DMX mode
`DMX 14Ch’
14-channel DMX mode
`DMX 26Ch’
26-channel DMX mode
`Slave’
“Slave” mode
13 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
Main menu
Menu level 2 Meaning Auto’
Static’
14 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Menu level 3 Auto Fading’
Auto Jumping’ Dimmer’
Strobe’
Red’
Green’ Blue’
White’ `Rainbow Effect’
Menu level 4
0…255 0…255 0…255
Strobe effect 0…5 6…10 11…33
34…56
57…79
80…102
103…127
128…250
251…255 0…255
0…255
0…255
0…255
Rainbow effect 0…5 6…21 22…37 38…53 54…69 70…85 86…101 102…117 118…133 134…149
Automatic fade effect Automatic jump effect Setting the overall brightness
Open strobe Closed strobe Random pulse effect with increasing speed Random
ramp-up effect with increasing speed Random ramp-down effect with increasing
speed Random strobe effect with increasing speed Strobe-break effect with
decreasing dura- tion of interruptions Strobe effect with increasing speed
Open strobe Red intensity (0% to 100%) Green intensity (0% to 100%) Blue
intensity (0% to 100%) White intensity (0% to 100%)
Effect off Rainbow effect 1 Rainbow effect 2 Rainbow effect 3 Rainbow effect 4
Rainbow effect 5 Rainbow effect 6 Rainbow effect 7 Rainbow effect 8 Rainbow
effect 9
Main menu
Menu level 2 Meaning
`Color Macro’
Operating
Menu level 3 Auto’
Auto speed’
Menu level 4
150…165 166…181 182…197 198…213 214…229 230…255 Automatic show 0…5 6…30 31…55
56…80 81…105 106…130 131…155 156…180 181…205 206…230 231…255 0…255
Auto Fade’ Pre-defined colour
Red’ Amber’
Yellow Warm’ Yellow’
Green’ Turquoise’
Cyan’ Blue’
Lavender’ Mauve’
Magenta’ Pink’
Warm White’
0…255
Red Amber Yellow amber Yellow Green Turquoise Cyan Blue Lavender Mauve Magenta
Pink Warm white
Rainbow effect 10 Rainbow effect 11 Rainbow effect 12 Rainbow effect 13
Rainbow effect 14 Rainbow effect 15
No automatic show Automatic show 1 Automatic show 2 Automatic show 3 Automatic
show 4 Automatic show 5 Automatic show 6 Automatic show 7 Automatic show 8
Automatic show 9 Automatic show 10 Running speed of the automatic show,
increasing Fade speed for auto- matic shows
15 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
Main menu `Settings’
Menu level 2 Meaning Display Rev’
Display’ DMX Fail’
Dimmer Curve’
Dimmer Response’
LED Frequency’
White Balance’
Fan Set’
`Wireless DMX’
Menu level 3
Menu level 4
`White’
White
`Cold White’
Cold white
Display inversion
`ON’
On. The display is rotated by 180°
`OFF’
Off. Normal display
Automatic shut-down of the display when device not in use
`ON’
Disabled
`OFF’
Enabled
Device behaviour on DMX signal failure
`Hold’
Retain most recent settings
`Blackout’
Blackout
Dimmer curve
`Linear’
Linear
`Exp’
Exponential
`Log’
Logarithmic
`S-Curve’
S-shaped
Dimmer characteristic
`LED’
Dimmer characteristic “LED” (3 s delay)
`Halogen’
Dimmer characteristic “Halogen” (5 s delay)
`800 Hz’
Refresh rate of the LEDs: 800 Hz
`1200 Hz’
Refresh rate of the LEDs: 1200 Hz
`2000 Hz’
Refresh rate of the LEDs: 2000 Hz
`3600 Hz’
Refresh rate of the LEDs: 3600 Hz
`25 KHz’
Refresh rate of the LEDs: 25 kHz
White balance
`Red’
0…255
Red proportion
`Green’
0…255
Green proportion
`Blue’
0…255
Blue proportion
`White’
0…255
White proportion
Fan speed
`Regular’
If the temperature exceeds the threshold, the fan speed will increase.
`Silent’
If the temperature exceeds the threshold, the light output is reduced; fan speed remains the same.
Resetting the wireless DMX connection
16 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Operating
Main menu `System Info’
Menu level 2 Meaning
Test’
Factory Reset’ Key lock’
Firmware’ Temperature’
Time info’
Menu level 3
Menu level 4
`Reset Wireless DMX
`No’
Memory’
The wireless DMX con- nection is not reset
`Yes’
The wireless DMX con-
nection is reset
Automatic self test
`OFF’
Off
`ON’
On
Reset to factory defaults
`OFF’
Off
`ON’
Starting
Key lock
`OFF’
Off
`ON’
Enabled
To unlock the keys, press [ENTER], [UP], [DOWN], [UP], [DOWN] and then [ENTER].
Show firmware version of the device
`LED Temp’
Show device temperature
`Temp Unit’
Unit selection for device temperature
`Fahrenheit’
`Celsius’
Operating hours display
`Power on’
Total operating hours
`Last run hrs’
Operating hours since last power up
7.2.1 “DMX” mode
In “DMX” mode, the display shows the set DMX mode in its top row and the DMX
start address set in the lower part. The display flashes if no DMX signal is
received.
If the device is controlled via “W-DMX”, the [W-DMX] LED on the front of the
device flashes. The display shows the signal strength in the top row.
7.2.2 “Slave” mode
no signal
weak signal
medium signal
strong signal
In “Slave” mode, the lower section of the display shows `Operating Mode: SLAVE’ . The display flashes if no control signal is received.
17 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
7.2.3 “Stand-alone” mode
In “Stand-alone” mode, the lower section of the display shows the current
device set- ting:
n Operating Mode: AUTO Fading’ : Automatic fade effect n
Operating Mode:
AUTO Jumping’ : Automatic jump effect n Operating Mode: STATIC’ : Freely mixable colour with optional rainbow and strobe effect or automatic show n
Operating Mode: Color Macro’ : Selecting a
pre-defined colour macro
7.3 Menu overview
DMX Address Set DMX Address
001 512
Mode DMX Signal Select
DMX Mode
Slave Auto
DMX Wireless DMX
DMX 2CH DMX 3CH1 DMX 3CH2 DMX 4CH DMX 6CH DMX 12CH DMX 14CH DMX 26CH
Slave Auto Fading Auto Jumping
Static
000 255 000 255
Dimmer Strobe
Red Green Blue White Rainbow Effect Auto Auto Speed Auto Fade
000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255
Color Macro
Red Amber Yellow Amber Yellow Green Turquois Cyan
Blue Lavender
Mauve Magenta
Pink Warm White
White Cold White
Settings
Display Rev
ON
LED Frequency
800Hz
OFF
1200Hz
Display
ON
2000Hz
OFF
3600Hz
DMX Fail
Hold Blackout
White Balance
25KHz Red
0 255
Dimmer Curve
Linear
Green
0 255
Exp
Blue
0 255
Log
White
0 255
S-Curve
Fan Set
Regular
Dimmer Response
LED
Silent
Halogen
Wireless DMX
Reset Wireless DMX Memory
Yes
No
TEST
ON
OFF
Factory Reset
Yes
No
Keylock
ON
OFF
System Info Firmware Temperature
Time Info
Software Version Vxxx LED Temp Temp Unit
Power on Last Run Hrs
xxxC Fahrenheit
Celsius xxx(Hours) xxx(Hours)
18 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
7.4 Functions in 2-channel DMX mode
Channel 1 2
Value 0…255 Colour macro 0…5 6…13 14…21 22…29 30…37 38…45 46…53 54…61 62…69 70…77 78…85 86…93 94…101 102…109 110…117 118…125 126…127 128…191 192…255
Function Dimmer (0% to 100%)
Blackout Red Amber Yellow amber Yellow Green Turquoise Cyan Blue Lavender
Mauve Magenta Pink Warm white, 3200 K White, 5600 K Cold white, 7200 K Colour
change halted Colour change effect, increasing speed Colour transition effect,
increasing speed
7.5 Functions in 3-channel DMX mode 1
Channel 1 2
3
Value
Function
0…255
Dimmer (0 % to 100 %)
Stroboscope functions
0…5
Open strobe
6…10
Closed strobe
11…250
Strobe effect with increasing speed
251…255
Open strobe
Colour macro
0…5
Blackout
6…13
Red
Operating
19 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
Channel
Value 14…21 22…29 30…37 38…45 46…53 54…61 62…69 70…77 78…85 86…93 94…101 102…109 110…117 118…125 126…127 128…191 192…255
Function Amber Yellowish-amber coloured Yellow Green Turquoise Cyan Blue Lavender Mauve Magenta Pink Warm white, 3200 K White, 5600 K Cold white, 7200 K Colour change halted Colour change effect, increasing speed Colour transition effect, increasing speed
7.6 Functions in 3-channel DMX mode 2
Channel 1 2 3
Value 0…255 0…255 0…255
Function Intensity red (0 % to 100 %) Intensity green (0 % to 100 %) Intensity blue (0 % to 100 %)
7.7 Functions in 4-channel DMX mode
Channel 1 2 3 4
Value 0…255 0…255 0…255 0…255
Function Intensity red (0 % to 100 %) Intensity green (0 % to 100 %) Intensity blue (0 % to 100 %) Intensity white (0 % to 100 %)
20 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
7.8 Functions in 6-channel DMX mode
Channel 1 2
3 4 5 6
Value
Function
0…255
Dimmer (0 % to 100 %)
Stroboscope functions
0…5
Open strobe
6…10
Closed strobe
11…250
Strobe effect with increasing speed
251…255
Open strobe
0…255
Intensity red (0 % to 100 %)
0…255
Intensity green (0 % to 100 %)
0…255
Intensity blue (0 % to 100 %)
0…255
Intensity white (0 % to 100 %)
7.9 Functions in 12-channel DMX mode
Channel 1 2 3 4 5 6 7 8 9 10 11 12
Value 0…255 0…255 0…255 0…255 0…255 0…255 0…255 0…255 0…255 0…255 0…255 0…255
Function Intensity red (0 % to 100 %), LED row 1 Intensity green (0 % to 100 %), LED row 1 Intensity blue (0 % to 100 %), LED row 1 Intensity white (0 % to 100 %), LED row 1 Intensity red (0 % to 100 %), LED row 2 Intensity green (0 % to 100 %), LED row 2 Intensity blue (0 % to 100 %), LED row 2 Intensity white (0 % to 100 %), LED row 2 Intensity red (0 % to 100 %), LED row 3 Intensity green (0 % to 100 %), LED row 3 Intensity blue (0 % to 100 %), LED row 3 Intensity white (0 % to 100 %), LED row 3
7.10 Functions in 14-channel DMX mode
Channel 1 2 3
Value
Function
0…255
Dimmer (0 % to 100 %)
0…255
Fine adjustment of the dimmer (0 % 100 %)
Stroboscope functions
0…5
Open strobe
Operating
21 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
Channel
4 5 6 7 8
9
Value 6…10 11…33 34…56 57…79 80…102 103…127 128…250 251…255 0…255 0…255 0…255 0…255 Colour macro 0…5 6…13 14…21 22…29 30…37 38…45 46…53 54…61 62…69 70…77 78…85 86…93 94…101 102…109 110…117 118…125 126…127 128…191 192…255 Rainbow effect 0…5 6…21 22…37
Function Closed strobe Random Pulse effect with increasing speed Random Ramp-
up effect with increasing speed Random Ramp-down effect with increasing speed
Random strobe effect with increasing speed Strobe-break effect with decreasing
duration of interruptions Strobe effect with increasing speed Open strobe
Intensity red (0 % to 100 %) Intensity green (0 % to 100 %) Intensity blue (0
% to 100 %) Intensity white (0 % to 100 %)
Blackout Red Amber Yellowish-amber coloured Yellow Green Turquoise Cyan Blue
Lavender Mauve Magenta Pink Warm white, 3200 K White, 5600 K Cold white, 7200
K Colour change halted Colour change effect, increasing speed Colour
transition effect, increasing speed
Effect off Rainbow effect 1 Rainbow effect 2
22 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Operating
Channel
10
11 12 13 14
Value
Function
38…53
Rainbow effect 3
54…69
Rainbow effect 4
70…85
Rainbow effect 5
86…101
Rainbow effect 6
102…117
Rainbow effect 7
118…133
Rainbow effect 8
134…149
Rainbow effect 9
150…165
Rainbow effect 10
166…181
Rainbow effect 11
182…197
Rainbow effect 12
198…213
Rainbow effect 13
214…229
Rainbow effect 14
230…255
Rainbow effect 15
Automatic show
0…5
No automatic show
6…30
Automatic show 1
31…55
Automatic show 2
56…80
Automatic show 3
81…105
Automatic show 4
106…130
Automatic show 5
131…155
Automatic show 6
156…180
Automatic show 7
181…205
Automatic show 8
206…230
Automatic show 9
231…255
Automatic show 10
0…255
Running speed automatic show, increasing
0…255
Automatic Fade effect
Dimmer curve
0…5
No function
6…63
Linear
64…127
Exponential
128…191
Logarithmic
192…255
S-shaped
Special functions. Settings are enabled or retained if the corresponding DMX value is held for five seconds.
0…5
No function
6…63
Dimmer characteristic `LED’ (3 s delay)
23 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
Channel
Value 64…127 128…191 192…255
Function Dimmer characteristic Halogen’ (5 s delay) Fan speed setting
Silent’ activated (3 s delay) Fan speed setting `Silent’ deactivated (3 s
delay)
7.11 Functions in 26-channel DMX mode
Channel 1 2 3
4 5 6 7 8
Value
Function
0…255
Dimmer (0 % to 100 %)
0…255
Fine adjustment of the dimmer (0 % 100 %)
Stroboscope functions
0…5
Open strobe
6…10
Closed strobe
11…33
Random Pulse effect with increasing speed
34…56
Random Ramp-up effect with increasing speed
57…79
Random Ramp-down effect with increasing speed
80…102
Random strobe effect with increasing speed
103…127
Strobe-break effect with decreasing duration of interruptions
128…250
Strobe effect with increasing speed
251…255
Open strobe
0…255
Intensity red (0 % to 100 %)
0…255
Intensity green (0 % to 100 %)
0…255
Intensity blue (0 % to 100 %)
0…255
Intensity white (0 % to 100 %)
Colour macro
0…5
Blackout
6…13
Red
14…21
Amber
22…29
Yellowish-amber coloured
30…37
Yellow
38…45
Green
46…53
Turquoise
54…61
Cyan
62…69
Blue
70…77
Lavender
78…85
Mauve
86…93
Magenta
24 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Channel 9
10
Value
Function
94…101
Pink
102…109
Warm white, 3200 K
110…117
White, 5600 K
118…125
Cold white, 7200 K
126…127
Colour change halted
128…191
Colour change effect, increasing speed
192…255
Colour transition effect, increasing speed
Rainbow effect
0…5
Effect off
6…21
Rainbow effect 1
22…37
Rainbow effect 2
38…53
Rainbow effect 3
54…69
Rainbow effect 4
70…85
Rainbow effect 5
86…101
Rainbow effect 6
102…117
Rainbow effect 7
118…133
Rainbow effect 8
134…149
Rainbow effect 9
150…165
Rainbow effect 10
166…181
Rainbow effect 11
182…197
Rainbow effect 12
198…213
Rainbow effect 13
214…229
Rainbow effect 14
230…255
Rainbow effect 15
Automatic show
0…5
No automatic show
6…30
Automatic show 1
31…55
Automatic show 2
56…80
Automatic show 3
81…105
Automatic show 4
106…130
Automatic show 5
131…155
Automatic show 6
156…180
Automatic show 7
181…205
Automatic show 8
206…230
Automatic show 9
231…255
Automatic show 10
Operating
25 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Operating
Channel 11 12 13
14
15 16 17 18 19 20 21 22 23 24 25 26
Value
Function
0…255
Running speed automatic show, increasing
0…255
Automatic Fade effect
Dimmer curve
0…5
No function
6…63
Linear
64…127
Exponential
128…191
Logarithmic
192…255
S-shaped
Special functions. Settings are enabled or retained if the corresponding DMX value is held for five seconds.
0…5
No function
6…63
Dimmer characteristic `LED’ (3 s delay)
64…127
Dimmer characteristic `Halogen’ (5 s delay)
128…191
Fan speed setting `Silent’ activated (3 s delay)
192…255
Fan speed setting `Silent’ deactivated (3 s delay)
0…255
Intensity red (0 % to 100 %), LED row 1
0…255
Intensity green (0 % to 100 %), LED row 1
0…255
Intensity blue (0 % to 100 %), LED row 1
0…255
Intensity white (0 % to 100 %), LED row 1
0…255
Intensity red (0 % to 100 %), LED row 2
0…255
Intensity green (0 % to 100 %), LED row 2
0…255
Intensity blue (0 % to 100 %), LED row 2
0…255
Intensity white (0 % to 100 %), LED row 2
0…255
Intensity red (0 % to 100 %), LED row 3
0…255
Intensity green (0 % to 100 %), LED row 3
0…255
Intensity blue (0 % to 100 %), LED row 3
0…255
Intensity white (0 % to 100 %), LED row 3
26 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Technical specifications
8 Technical specifications
265 mm 102 mm
170 mm
389 mm 346 mm 320 mm
139 mm
Light source
18 × RGBW-LED, 15 W each
Optical properties
Beam angle
25° (with filter 40°)
Control
DMX, W-DMX, buttons and display on the unit
Number of DMX channels 2, 3, 4, 6, 12, 14 or 26
Input connections
Power supply
1 × Lockable panel plug (Power Twist TR1 IP65)
DMX control
1 × XLR panel plug, 3-pin, IP65 design
Output connections
Power supply for further devices
1 × Lockable panel socket (Power Twist TR1 IP65)
Output current, max.: 6 A
DMX control
1 × XLR panel socket, 3-pin, IP65 design
W-DMX
Frequency range
2.400 GHz…2.4835 GHz
Max. transmission power
10 mW or 10 dBm
Range
50 m
Power consumption
250 W
Inrush current
60 A, 375 µs
Supply voltage
100 – 240 V 50/60 Hz
International Protection IP65 Rating
Mounting options
hanging, standing, omega bracket
Dimensions (W × H × D) 389 mm × 265 mm × 170 mm (panel horizontal)
Weight
8.2 kg
Ambient conditions
Temperature range
20 °C…+40 °C
Relative humidity
20%…80% (non-condensing)
96 mm
Further information
Outdoor housing design Colour mix LED type Floor housing Fanless Remote control Wireless DMX Housing colour
Flood light RGBW x-in-1 Yes No Not possible Yes Black
27 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Plug and connection assignments
9 Plug and connection assignments
Introduction
This chapter will help you select the right cables and plugs to connect your
valuable equipment so that a perfect light experience is guaranteed.
Please take our tips, because especially in Sound & Light’ caution is indicated: Even if a plug fits into a socket, the result of an incorrect connection may be a destroyed DMX controller, a short circuit or
just’ a not
working light show!
DMX connections
The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suit- able XLR plug.
Pin Configuration
1
Ground, shielding
2
Signal inverted (DMX, `cold signal’)
3
Signal (DMX+, `hot signal’)
28 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Troubleshooting
10 Troubleshooting
NOTICE! Data transfer errors due to improper wiring! If the DMX connections
are wired incorrectly, this can cause errors during the data transfer.
Do not connect the DMX input and output to audio devices, e.g. mixers or
amplifiers.
Use special DMX cables for the wiring instead of normal microphone cables.
In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting:
Symptom The device is not working, no light One colour does not work or the
colours differ when using multiple lamps.
No response to the DMX controller
The devices do not connect to the W-DMX transmitter or do not respond to the
W-DMX signal. The device responds slowly or not at all to the W-DMX signal.
Unintended light effects
Remedy
Check the mains connection and main fuse.
Check the settings in the White Balance’ menu. If the function is missing, values may be set to
000′ .
If the colour rendering is different, set all values for the colours in the
White Balance’ menu to
255′ . You can then fine-tune the colour rendering.
1. Check the DMX connectors and cables for proper connection.
2. Check the address settings and the DMX polarity.
3. Try using another DMX controller.
4. Check whether the DMX cables run near or parallel to high-voltage cables
that may cause damage or interference to a DMX interface circuit.
5. Press Mode until the display shows ADDRESS XXX’ . 6\. Check whether
DMX’ (with wired connection) is selected in the DMX Signal Select’ menu. Check whether
Wireless DMX’ is selected in the DMX Signal Select’ menu. Reset the connection by performing a reset in the
Reset Wireless DMX Memory’
menu. The devices must then be reassigned to the transmitter by pressing the
[Link] button on the transmitter.
Check the transmission mode of the W-DMX transmitter. Test the connection with
the G5, G4S or G3 mode (if possible). Please note that the W-DMX must be reset
on all devices after the transmitter has been changed.
Make sure that the DMX channel assignments of the devices do not overlap, and
that the DMX start address of devices with independent control is always
higher by the number of channels that have been set for the DMX mode on
another device.
If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de.
29 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Cleaning
11 Cleaning
Optical lenses
Clean the optical lenses, that are accessible from the outside, regularly in
order to optimize the light output. The frequency of cleaning depends on the
operating envi- ronment: wet, smoky or particularly dirty surroundings can
cause more accumulation of dirt on the optics of the device.
n Clean with a soft cloth using our lamp and lens cleaner (item no. 280122). n
Always dry the parts carefully.
30 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Protecting the environment
12 Protecting the environment
Disposal of the packing material
Environmentally friendly materials have been chosen for the packaging. These
mate- rials can be sent for normal recycling. Ensure that plastic bags,
packaging, etc. are dis- posed of in the proper manner.
Do not dispose of these materials with your normal household waste, but make
sure that they are collected for recycling. Please follow the instructions and
markings on the packaging.
Observe the disposal note regarding documentation in France.
Disposal of your old device
This product is subject to the European Waste Electrical and Electronic
Equipment Directive (WEEE) as amended.
Do not dispose of your old device with your normal household waste; instead,
deliver it for controlled disposal by an approved waste disposal firm or
through your local waste facility. If in doubt, consult your local waste
management facility. You can also return the device to a retailer if they
offer to take the device back for free or if they are legally obliged to do
so. When disposing of the device, comply with the rules and regulations that
apply in your country. You can also return your old device to Tho- mann GmbH
at no charge. Check the current conditions on www.thomann.de.
Proper disposal protects the environment as well as the health of your fellow
human beings. This is because the proper handling of old devices negates the
potential neg- ative effects of hazardous substances, and because it conserves
resources by recy- cling them.
Also note that waste avoidance is a valuable contribution to environmental
protec- tion. Repairing a device or passing it on to another user is an
ecologically valuable alternative to disposal.
If your old device contains personal data, delete those data before disposing
of it.
31 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Notes
32 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Notes
33 Co6 V2 LED Flood IP65 270W RGBW
LED Floodlight
Notes
34 Co6 V2 LED Flood IP65 270W RGBW LED Floodlight
Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>