Goodman AWST36LU1305 Air Handler Wall Mount Instruction Manual

September 27, 2024
Goodman

AWST36LU1305 Air Handler Wall Mount

“`html

Product Specifications

Model: AWST / AWSF Series

  • Nomenclature: AWST 18SU1303 AA

  • Nominal Capacity Range: 18 = 1.5 Tons, 24 =
    2.0 Tons, 30 = 2.5 Tons, 36 = 3.0 Tons

  • Electric Heat (kW): 3, 5, 8, 10

  • Refrigerant: R32

  • Electrical Data: 208/230 V, 1 Phase, 60
    Hz

  • Cabinet: U – Unpainted, P – Painted

  • Cabinet Width: AW* Series S = 20.2, L =
    24.0

Product Features

SS-GAWST-F-R32

Visit www.goodmanmfg.com for
more information.

Dimensions

Small Chassis (AWSF / AWST 18-24):

  • A: 36 inches
  • B: 20 3/16 inches
  • C: 16 inches
  • D: 16 inches
  • E: 11 inches
  • Filter: 14 x 18 x 1 inches

Airflow Data

Wiring Diagram

Product Usage Instructions

FAQ

Q: How should I tilt the unit for proper
condensate drainage?

A: Once installed, the top of the unit must be
level or slightly tilted back to ensure proper condensate
drainage.

“`

AWST / AWSF Series
Wall-Mount Air Handler 1½ to 3 Tons
Contents Nomenclature …………………………………..2 Accessories ………………………………………2 Product Specifications ……………………….3 Dimensions ………………………………………6 Airflow Data ……………………………………..7 Wiring Diagram …………………………………8

Product Features
· AWST Models: Equipped with a fully adjustable TXV
· AWSF Models: Equipped with a Check Flowrator
· Direct-drive, multi-speed motors allows air volume variation for heating/cooling
· Sequence-controlled, rust-resistant nickel chromium heating elements of 3, 5, 8, and 10 kW
· Aluminum tubing coils on all models
· Cabinet air leakage less than 2.0% at 1.0 inch HO when tested in accordance with ASHRAE standard 193
· UL 60335 2-40 Compliant

· Cabinet air leakage less than 1.4% at 0.5 inch HO when tested in accordance with ASHRAE standard 193
· Factory-installed pull-type disconnect
· Thermoplastic drain pan with bottom primary and secondary drain connections
· Built-in filter rack (filter included)
· Large chassis (2½- and 3-ton units) ­ front return only
· Small chassis (1½- and 2-ton units) ­ front or bottom return
· Wall-hanging bracket provided
· AHRI Certified; ETL Listed

SS-GAWST-F-R32

  • Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. The duration of warranty coverage in Texas and Florida differs in some cases.

www.goodmanmfg.com

05/24

Nomenclature

A W S T 18 S U

1

2

3 4 5,6 7

8

13

00

B

A

9 10 11,12 13 14

Product A Corporate Air Handler
Unit Application W Wall Mount
Motor S MS-ECM
Expansion Device F Flowrator T Thermal Expansion Valve
Nominal Capacity Range 18 = 1.5 Tons 24 = 2.0 Tons 30 = 2.5 Tons 36 = 3.0 Tons

Minor Rev
Major Revision Factory Installed Electric Heat KW
3 = 3kw 5 = 5kw 8 = 8kw 10 = 10kw
Refrigerant 3 – R32
Electrical 1 208/230 V, 1 Phase, 60 Hz
Cabinet U – Unpainted
P – Painted
Cabinet Width AW* Series S = 20.2″ L = 24.0″

Accessories
Model AWSF / AWST 18-24 AWSF / AWST 30-36

Item # Wad-1 Wad-2

Description Wall access door Wall access door

2

www.goodmanmfg.com

SS-GAWST-F-R32

Product Specifications

AWST 18SU1303 AA

Nominal Ratings Cooling (BTU/h) Electric Heat (kW) Blower Diameter Width Coil Connections Liquid Suction Coil Drain Connection (FPT) Electrical Data Voltage Minimum Circuit Ampacity Max. Overcurrent Device (Amps) Minimum VAC Maximum VAC Blower Motor Full Load Amps (FLA) Horsepower (HP) Ship Weight (lbs)

18000 3
10 6
” ” ¾”
208/230 16.8/18.9
20/20 197 253
2.6 1/3 84

AWSF18 SU1305 AA
AWST18 SU1305 AA
18000 5
10 6
” ” ¾”
208/230 24.9/28.3
25/30 197 253
2.6 1/3 84

AWSF18 SU1308 AA
AWST18 SU1308 AA
18000 8
10 6
” ” ¾”
208/230 36.2/41.3
40/45 197 253
2.6 1/3 84

AWSF24 SU1305 AA
AWST24 SU1305 AA
24000 5
10 6
” ” ¾”
208/230 24.9/28.3
25/30 197 253
2.6 1/3 84

AWSF24 SU1308 AA
AWTF24 SU1308 AA
24000 8
10 6
” ” ¾”
208/230 36.2/41.3
40/45 197 253
2.6 1/3 84

AWSF24 SU1310 AA
AWST24 SU1310 AA
24000 10
10 6
” ” ¾”
208/230 46.6/53.3
50/60 197 253
2.6 1/3 84

SS-GAWST-F-R32

www.goodmanmfg.com

3

Product Specifications (Contd.)

Nominal Ratings Cooling (BTU/h) Electric Heat (kW) Blower Diameter Width Coil Connections Liquid Suction Coil Drain Connection (FPT) Electrical Data Voltage Minimum Circuit Ampacity Max. Overcurrent Device (Amps) Minimum VAC Maximum VAC Blower Motor Full Load Amps (FLA) Horsepower (HP) Ship Weight (lbs)

AWSF30 LU1305 AA
AWST30 LU1305 AA
30000 5
10 8
” ¾” ¾”
208/230 26.4/29.8
30/30 197 253
3.8 1/2 109

AWSF30 LU1308 AA
AWST30 LU1308 AA
30000 8
10 8
” ¾” ¾”
208/230 37.7/42.8
40/45 197 253
3.8 1/2 109

AWSF30 LU1310 AA
AWST30 LU1310 AA
30000 10
10 8
” ¾” ¾”
208/230 48.1/54.8
50/60 197 253
3.8 1/2 109

AWSF36 LU1305 AA
AWST36 LU1305 AA
36000 5
10 8
” ¾” ¾”
208/230 26.4/29.8
30/30 197 253
3.8 1/2 109

AWSF36 LU1308 AA
AWST36 LU1308 AA
36000 8
10 8
” ¾” ¾”
208/230 37.7/42.8
40/45 197 253
3.8 1/2 109

AWSF36 LU1310 AA
AWST36 LU1310 AA
36000 10
10 8
” ¾” ¾”
208/230 48.1/54.8
50/60 197 253
3.8 1/2 109

4

www.goodmanmfg.com

SS-GAWST-F-R32

Note – Once installed, top of unit must be level or slightly tilted back to ensure proper condensate drainage.

Dimensions

Small Chassis (AWSF / AWST 18-24)

A

36″

B

203/16″

C

16″

D

16″

E

11″

Filter

14″ x 18″ x 1″

Large Chassis (AWSF / AWST 30-36)

A

36″

B

24″

C

21″

D

19″

E

15″

Filter (30, 36, 31, 32, 37) 18″ x 20″ x 1″

SS-GAWST-F-R32

www.goodmanmfg.com

5

Dimensions (Contd.)
B

K J

TOP VIEW

E C
H I G F

D A

Fresh Air Openings

4.0″
Front

3.0″

3.0″

Bottom

L

M N

BOTTOM VIEW

A

B

C

D

E

F

G

H

I

J

K

L

M

N

AWSF/ AWST 18-24 36″ 20¼” 16″ 16″

11″

1¾”

1½”

2¼”

1″

1¾”

4″

6″ 10″

AWSF/ AWST 30-36 36″ 24″ 21″ 19″ 16″

4″

1½”

1¾”

2″

1¼”

2″

4″

8″ 12″

6

www.goodmanmfg.com

SS-GAWST-F-R32

Airlfow Data

Model

Speed Tap

T1

T2

AWSF18SU13 AA AWST18SU13 AA

T3

T4

T5

T1

T2

AWSF24SU13 AA AWST24SU13 AA

T3

T4

T5

T1

T2

AWSF30LU13 AA AWST30LU13 AA

T3

T4

T5

T1

T2

AWSF36LU13 AA AWST36LU13 AA

T3

T4

T5

Note: Airflow data indicated is at 230 V with no filter in place.

0.1″ 630 630
637 630 846 630 630 784 630 846 711 934 1094 973 1180 1114 1114 1225 1287 1360

CFM Delivered Against External Static Pressure

0.2″ 602 602 609 602 824 602 602
763 602
823 660 890 1047 928 1139 1072 1072 1191 1255 1329

0.3″ 576 576 586 576 800 576 576 742 576 800 575 850 1012 890 1102 1031 1031 1152 1219 1299

0.4″ 550 550 557 550
777 550 550
728 550
777 529 803 977 851 1069 982 982 1112 1183 1264

0.5″ 521 521 531 521 756 521 521 705 521 756 438 725 941
777 1036 924 924 1071 1146 1230

SS-GAWST-F-R32

www.goodmanmfg.com

7

SS-GAWST-F-R32

www.goodmanmfg.com

8

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Warning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

AWSF18SU13, AWST18SU13 Wiring Diagram

9

www.goodmanmfg.com

SS-GAWST-F-R32

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Warning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

AWSF24SU13, AWST24SU13 Wiring Diagram

SS-GAWST-F-R32

www.goodmanmfg.com

10

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Warning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

AWSF30LU13, AWST30LU13 Wiring Diagram

11

www.goodmanmfg.com

SS-GAWST-F-R32

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Warning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

AWSF36LU13, AWST36LU13 Wiring Diagram

Notes

Our continuing commitment to quality products may mean a change in specifications without notice.

©2024

· Houston, Texas · Printed in the USA.

12

www.goodmanmfg.com

SS-GAWST-F-R32

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals