Product Information

Specifications:

  • Model: PDDEG-S

  • Product Name: Ethernet Gateway Supervisor

  • Dimensions: 216 mm x 104 mm x 95 mm (8.50 in x 4.09 in x 3.74
    in)

  • Pollution Degree: 1A IEC Pollution Degree II

  • Operating Temperature: 0-45°C (32-113°F)

  • Humidity: 90%

  • Power Input: 100-277 V, 0.25 A

  • Overvoltage Category: IEC Overvoltage Category III

Product Usage Instructions:

Installation:

Devices must be installed in an approved enclosure by a
qualified electrician following all national and local electrical
and construction codes and regulations.

Connection:

Connect the Ethernet Gateway Supervisor to the power source and
ensure proper grounding.

Network Configuration:

For optimal performance, connect to Ethernet ports as
instructed. Refer to dynalite.com/support for port availability
details.

BMS and Lighting Integration:

It is recommended to connect the Building Management System
(BMS) and lighting systems on separate VLANs for efficient
operation.

FAQ:

Q: What are the temperature limits for communication

wires?

A: The temperature limits and current-carrying capacities for
the communication wires specified in IEC 60364-5-52 should not be
exceeded during installation.

Q: What standards does the product comply with?

A: The product complies with Canadian ICES-003: CAN
ICES-3(B)/NMB-3(B) and IEC 60364 standards for home and building
automation systems.

PDDEG-S
Ethernet Gateway Supervisor

Installation Instructions
Instructions d’installation Installationsanweisungen Instrucciones de instalación Istruzioni per l’installazione Installatie-instructies

Devices must be installed in an
approved enclosure by a qualified electrician in accordance with all
national and local electrical and
construction codes and regulations.
Les appareils doivent être installés dans un lieu jugé apte, par un électricien qualifié et conformément aux règles et normes locales et nationales en matière d’électricité et de construction.
Die Geräte müssen von einem geprüften Elektriker entsprechend allen nationalen und lokalen Elektro ­ und Bauvorschriften in einem zugelassenen Gehäuse installiert werden.

Los dispositivos se deben instalar en un recinto aprobado por un electricista cualificado de acuerdo a todos los reglamentos eléctricos y de construcción locales y nacionales pertinentes
I dispositivi devono essere installati da un elettricista qualificato in un luogo approvato, in conformità a tutti gli standard e le norme nazionali e locali vigenti in materia di impianti elettrici e costruzioni edilizie.
Apparaten moeten door een erkende elektricien worden geïnstalleerd in een goedgekeurde behuizing in overeenstemming met alle nationale en lokale elektriciteits ­ en bouwvoorschriften en wetgeving.

/

104 mm (4.09 in) 95 mm (3.74 in)

1A IEC Pollution Degree II

216 mm (8.50 in)

64 mm (2.52 in)

45 mm (1.77 in)

45 mm (1.77 in)

50° C (122° F) 0° C (32° F)

90%

68 mm (2.68 in)

1B

160 mm (6.30 in)

45 mm (1.80 in)
45 mm (1.80 in)

2

3

Ethernet 1 Ethernet 2*

SHLD GND D+ D+12 V AUX

GND

AUX < 20 m

0.3-2.5mm2 22-12 AWG

0.4 Nm 3.5 Lb-in

2 A RS-485 DyNet

RJ45 Ethernet
*Refer to dynalite.com/support for port 2 availability.

4

5

0.2-5 mm2 24-10 AWG

6

Link
Link
Connecting Connected

Ethernet 1 Ethernet 2
Cloud

Service LED
OK OK, Network busy
Booting (60 s) Fault

7 NL
100-277 V 0.25 A

IEC Overvoltage Category III

µP

SHLD GND
D+ D+12 V AUX

12V 300 mA

RS-485 DyNet

RJ45 Socket

RJ45 Socket

Ethernet 1 Ethernet 2

SELV / Class 2 (UL)

8 A BACnet Integration BACnet
(BMS LAN)
Ethernet

Lighting LAN

We recommend connecting the BMS and lighting systems on different VLANs.
8B

Ethernet

RS-485 DyNet RS-485 DyNet

8C

9

Ethernet

RS-485 DyNet

FCC and RSS-210 of IC (Industry Canada) Rules ­ This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and pursuant to RSS210 of the IC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any modifications not approved by the manufacturer of this device could void the user’s authority to operate this device.
This Class B digital apparatus complies with Canadian ICES-003: CAN ICES-3(B)/NMB-3(B). Cet appareil numerique de la Classe B est conforme a la norme NMB-003 du Canada: CAN ICES-3(B)/NMB-3(B).
Installation of a home and building automation and control system shall comply with IEC 60364 (all parts). The temperature limits and current-carrying capacities for the communication wires specified in IEC 60364-5-52 shall not be exceeded.

© 2024 Signify Holding. All rights reserved. Specifications are subject to change without notice. No representation or warranty as to the accuracy or
completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners.

www.dynalite.com
AZZ 508 0724 R14

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals