HMS-1000 NAZ Solar Electric
“`html
Product Information
Specifications:
-
Model: HMS-1000-2T-NA Series
-
Applicable Models: HMS-700/800/900/1000-2T-NA
microinverters -
Cable Type: AC Trunk Cable
-
Cable Gauge: 12/10 AWG
Product Usage Instructions
1. Installation Steps:
Step 1. Plan and Install the Microinverter:
-
Mark the position of each microinverter on the rail according
to the PV module layout. -
Fix the screws on the rail.
-
Hang the microinverter on the screws, and tighten the screws.
Ensure the silver cover side of the microinverter faces the
panel.
Step 2. Plan and Build the AC Bus Cable:
-
Select the appropriate AC Trunk Cable according to the spacing
between microinverters. -
Determine the number of microinverters per AC branch and
prepare AC Trunk Connectors accordingly. -
Take out segments of AC Trunk Cable to create AC branches.
-
Disassemble the AC Trunk Connector using the Unlock Tool.
-
Install the AC Trunk End Cap at one side of the cable.
-
Install AC end cable on the other side connected to the
distribution box. -
Attach the AC Trunk Cable to the mounting rail and secure with
tie wraps.
Step 3. Complete the AC Connection:
-
Push the AC Sub Connector from microinverter to the AC Trunk
Connector until it clicks. -
Connect the AC end cable to the distribution box and wire it to
the grid network. -
Plug the AC Trunk Port Cap in any vacant AC Trunk Port for
protection against water and dust.
FAQ (Frequently Asked Questions)
Q: Are all accessories included in the package?
A: No, all accessories listed are not included in the package
and should be purchased separately.
Q: How do I remove the inverter AC cable from the AC Trunk
Connector?
A: Use the AC Trunk Port Disconnect Tool and insert it into the
side of the AC Sub Connector to complete the removal process.
“`
1. Accessories
HMS-1000-2T-NA Series Quick Installation Guide
*Applicable to HMS-700/800/900/1000-2T-NA microinverters
Item A
Description AC Trunk Cable, 12/10 AWG Cable
B
M8 x 25 screws (Prepared by the installer)
C
Grounding Electrode
D
AC Trunk Connector
E
AC Trunk Port Cap
F
AC Trunk Port Disconnect Tool
G
AC Trunk End Cap
H
AC Trunk Connector Unlock Tool
A
BC
*Note: All accessories above are not included in the package and should be purchased separately.
2. Installation Steps
The order of Step 1 and Step 2 can be reversed according to your planned
needs.
Step 1. Plan and Install the Microinverter
A ) Mark the position of each microinverter on the rail according to the PV
module layout.
D
EF GH
B ) Fix the screws on the rail.
C ) Hang the microinverter on the screws, and tighten the screws. The silver
cover side of the microinverter should be facing the panel.
Mounting Torque : 9 N·m
Note: 1. There is an earth wire inside the wire cable and the grounding can be
done directly by this wire. If external grounding is needed, the grounding
electrode, as shown on the right, can be used to bond the mounting bracket to
the racking. Torque each grounding cleat screw to 2 N·m. 2. Install the
microinverter and all DC connections under the PV module to avoid direct
sunlight, rain exposure, snow buildup, UV, etc. 3. Leave at least 2 cm of
space around the microinverter enclosure to ensure ventilation and heat
dissipation. 4. Mounting torque of the 8 mm screws should be 9 N·m.Please do
not over-torque. 5. Do not pull or hold the AC cable with your hand. Hold the
handle instead.
Step 2. Plan and build the AC Bus Cable
AC Trunk Cable is used to connect the microinverter to distribution box.
A ) Select the appropriate AC Trunk Cable according to the spacing between
microinverters. The connector spacing of the AC Trunk Cable should be close to
spacing between microinverters to ensure that they are well-matched. (Hoymiles
provides AC Trunk Cable with different AC Trunk Connector spacing)
B ) Determine how many microinverters you plan to install on each AC branch
and prepare AC Trunk Connectors accordingly.
C ) Take out segments of AC Trunk Cable as you need to make AC branch. 1 )
Disassemble the AC Trunk Connector and remove the cable.
– Use the AC Trunk Connector Unlock Tool to unlock the connector upper cover.
– Loosen the three screws with screwdriver. Untighten the cap and remove the
cable.
2 ) Install the AC Trunk End Cap at one side of AC Trunk Cable (the end of AC
Trunk Cable)
– Insert the AC Trunk End cap and screw the cap back to port, and then tighten
the cap.
– Plug the upper cover back to the Trunk connector.
click
4.0±0.5N·m
Region: North America AP040440 REV1.2 © 2022 Hoymiles Power Electronics Inc.
01
3 ) Install AC end cable on the other side of AC Trunk Cable (connected to the distribution box)
– Unlock the port upper cover, loosen the screws with screwdriver and remove the extra cable. (Skip this step if there is no cable at this side.)
– Prepare a segment of AC cable with suitable length to connect to the
distribution box, with stripping requirements fulfilled.
– Insert the cable into the cap in a way that the L, N and PE lines are in
corresponding slots.
8±1mm
40±5mm L PE N
– Tighten the screws and tighten the cap back to the port.
4.0±0.5N·m
0.4±0.1N·m
– Plug the upper cover back to the Trunk connector.
click
Note: 1. Tightening torque of the cap: 4.0±0.5 N·m. Please do not over-torque.
2. Torque of locking screw: 0.4±0.1 N·m. 3. Do not damage the sealing ring in
the AC Trunk Connector during disassembly and assembly. D ) Repeat the above
steps, lay out the cable on the rail as appropriate so that the microinverters
can be connected to the Trunk connectors.
E ) Attach the AC Trunk Cable to the mounting rail and fix the cable with tie wraps.
Step 3. Complete the AC Connection
A ) Push the AC Sub Connector from microin-
verter to the AC Trunk Connector until it clicks
click
B ) Connect the AC end cable to the distribution box, and wire it to the local
grid network.
C ) Please plug the AC Trunk Port Cap in any vacant AC Trunk Port to make it
water and dust-proof.
Note: 1. Make sure that the AC Trunk Connectors are kept away from any water-
channeling surface. 2. In case you need to remove the inverter AC cable from
AC Trunk Connector, please use the AC Trunk Port Disconnect Tool and insert
the tool into the side of AC Sub Connector to complete the removal.
Step 4. Create an Installation Map
A ) Peel the removable serial number label from each microinverter.
B ) Affix the serial number label to the respective location on the
installation map (please refer to the User Manual).
Step 5. Connect PV Modules
A ) Mount the PV modules above the microinverter.
B ) Connect the PV modules’ DC cables to the DC input side of the
microinverter.
To sheet __
click
Please Make N for North
COLUMN
1
2
ROW
To sheet __
Hoymiles Microinverter Installation Map
Panel type: Azimuth: Tilt: Sheetof
Customer Information:
3
4
5
6
7
8
9
10
11
12
AP040228 V1.3 DTU Serial Number
13
14
15
16
A
B C D
To sheet __
To sheet __
Step 6. Energize the System
A) Turn on the AC breaker for the branch circuit. B) Turn on the main AC
breaker for the house. Your system will start to generate power in about two
minutes.
Step 7. Set up Monitoring System
Please refer to the “DTU User Manual”, “DTU Quick Installation Guide”, and
“Quick Installation Guide for S-Miles Cloud” to install the DTU and set up
monitoring system.
Product information is subject to change without notice. (Please download reference manuals at www.hoymiles.com).
Region: North America AP040440 REV1.2 © 2022 Hoymiles Power Electronics Inc.