madimack F300i InverFLOW ECO Inverter Pool Pump Installation Guide

September 25, 2024
madimack

INSTALLATION MANUAL Powered by

F300i InverFLOW ECO Inverter Pool Pump

PLEASE READ THE MANUAL CAREFULLY BEFORE INSTALLATION & OPERATION AND RETAIN IT FOR FUTURE REFERENCE.

Adherence to the directions for use in this manual is extremely important for health and safety. Failure to strictly adhere to the requirements in this manual may result in personal injury, property damage and affect your ability to make a claim under the manufacturer’s warranty provided with your product. Products must be used, installed and operated in accordance with this manual. You may not be able to claim on the manufactur- er’s warranty in the event that your product fault is due to failure to adhere this manual.

INSULATED WET END PUMP.
USE COPPER CONDUCTORS ONLY.
FOR USE WITH SWIMMING POOLS, HOT TUBS, AND SPAS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
CAUTION: THIS PUMP IS FOR USE WITH PERMANENTLY-INSTALLED POOLS ONLY — DO NOT USE WITH STORABLE POOLS.

IMPORTANT SAFETY INSTRUCTIONS

This guide provides installation and operation instructions for this pump. If you have any other questions about this equipment, please consult your Supplier.

1.1 When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

  • READ AND FOLLOW ALL INSTRUCTIONS.
  • WARNING — To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
  • WARNING — Risk of Electric Shock. Connect only to a branch circuit protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI.
  • The unit must be connected only to a supply circurt that is protected by a ground-fault circuit interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI Is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service representative before using it.
  • WARNING — To reduce the risk of electric shock, replace the damaged cord immediately.
  • CAUTION — This pump is for use with permanently-installed pools and may also be used with hot tubs and spas if so marked. Do not use It with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.
  • Do not install within an outer enclosure or beneath the skirt of a hot tub or spa.
  • A solid copper bonding conductor not smaller than 8 AWG (1/32″) shall be connected from the accessible wire connector on the motor to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within 5 feet (1.5 m) of the inside walls of a swimming pool, spa, or hot tub, when the motor is installed within 5 feet of the inside walls of the swimming pool, spa, or hot tub.
  • For Use with Swimming Pools, Hot Tubs, and Spas.
  • CAUTION: This Pump is for Use with Permanently-Installed Pools Only – Do Not Use with Storable Pools.
  • CAUTION: To reduce the risk of electric shock, install at least 6 feet from the inside walls of a pool. Do not use an extension cord.
  • CAUTION: To ensure continued protection against shock hazard, use only identical replacement parts when servicing.
  • This pump is for use with permanently installed in-ground or above-ground swimming pools and may also be used with hot tubs and spas with a water temperature under 50°C
  • Due to the fixed installation method, this pump is not suggested to be used on above-ground pools that can be readily disassembled for storage.
  • The pump is not submersible.
  • Never open the inside of the drive motor enclosure.
  • SAVE THESE INSTRUCTIONS.

WARNING:

  • Fill the pump with water before starting. Do not run the pump dry. In case of dry run, mechanical seal will be damaged and the pump will start leaking.
  • Before servicing the pump, switch power OFF to the pump by disconnecting the main circuit to the pump and release all pressure from pump and piping system.
  • Never tighten or loosen screws while the pump is operating.
  • Ensure that the inlet and outlet of the pump are unblocked with foreign matter.

TECHNICAL SPECIFICATIONS

Model THP HP Voltage (V/Hz) Qmax (US GPM) Hmax (Ft)
INVFLO300NA 0.85 1 220-240/50/60 92 52
INVFLO400NA 1.10 1.33 112 59
INVFLO500NA 1.50 1.8
123 66

OVERALL DIMENSION

INSTALLATION

4.1 Tools required

4.2 Pump Location
The pump should be installed in an area with at least 6″ distance around the unit away from any obstacles and away from any corrosive products.

  1. Install the pump as close to the pool as possible, to reduce friction loss and improve efficiency, use short, direct suction and return piping.
  2. To avoid direct sunshine, heat or rain, it is recommended to place the pump indoors or in the shade.
  3. DO NOT install the pump in a damp or non-ventilated location. Keep pump and motor at least 6″ away from obstacles, pump motors require free circulation of air for cooling.
  4. The pump should be installed horizontally and fixed in the hole on the support with screws to prevent unnecessary noise and vibration.

4.4 Valves and Fittings
It is recommended to install isolation valves on the suction and return lines for easier maintenance of the pool pump.
Elbows should be no closer than 14″ to the inlet. Do not install 90° elbows directly into the pump inlet/outlet. Joints must be tight.

4.3 Piping
Suction and return connections on the pool pumps are 2″ pressure pipe dimensions.

  1. For optimization of the pool plumbing, it is recommended to use a pipe with size of 2″. When installing the inlet and outlet fittings (joints), use the special sealant for PVC material.

  2. The dimension of suction line should be the same or larger than the inlet line diameter, to avoid pump sucking air, which will affect the efficiency of the pump.

  3. Plumbing on the suction side of the pump should be as short as possible.

  4. For most installations we recommend installing a valve on both the pump suction and return lines, which is more convenient for routine maintenance. However, we also recommend that are valve, elbow, or tee installed on the suction line should be no close to the front of the pump than seven times the suction line diameter

  5. Pump outlet piping system should be equipped with a check valve to prevent the pump from the impact of medium recirculation and pump-stopping water hammer.

  6. The pump inlet/ outlet union size: optional with imperial 1.5″ or 2″.

  7. Below water level system should have an isolation valves installed on suction and return line for maintenance; however, the suction gate valve should be no closer than seven times the suction pipe diameter as described in this section.

  8. A check valve should be installed if there are long pipe runs above water level or if is significant height between the return line and the outlet of the pump.

  9. Be sure to install check valves when plumbing in parallel with other pumps. This helps prevent reverse rotation of the impeller and motor.

4.5 Check before initial startup

  1. Check whether pump shaft rotates freely;
  2. Check whether power supply voltage and frequency conform to the nameplate;
  3. Facing the fan blade, the direction of motor rotation should be clockwise;
  4. It is forbidden to run the pump without water.

4.6 Application conditions

Ambient temperature Indoor installation, temperature range: -14°F∼104°F
Water temperature 41 °F∼122°F
Salt pools Up to 0.5%, i.e. 5g/L(5000 ppm)
Humidity ≤ 90% RH, (68°F±7°F )
Altitude Not exceed 3280ft above sea level
Installation The pump can be installed max. 6ft above water level
Insulation Class F. IP55

SETTING AND OPERATION

5.1 Display on control panel:

1 Running capacity / power display
2 Running capacity / power indicator
3 Timer indicator 1/2/3/4
Unlock
--- ---
UP To change the value of the setting.
DOWN
Timer setting / power reading
On/ Off

5.2 Startup
When the power is switched on, the screen will fully light up for 3 seconds, the device code will be displayed, and then it will enter the normal working state. When the screen is locked, only the button will light up; Press and hold for more than 3 seconds to unlock the screen. The screen will for more automatically lock up when there is no operation for more than 1 minute and the brightness of the screen will be reduced to 1/3 of the normal display. Short press to wake up the screen and observe the relevant operating parameters.

5.3 Self- priming
When switched on for the first time after installation, the pump will start self-priming.
When the pump performs self-priming, it will count down from 1500s and stop automatically when the system detects the pump is full of water, then the system will recheck for 120s again to make sure the self-priming is completed.
User can exit self-priming manually by pressing for more than 3 seconds. The pump will enter the default Manual- Inverter mode at the initial startup. If the user exits the self- priming in the subsequent startup, the pump will return to the previous state before the last shutdown.

Remark:
The pump is delivered with self-priming enabled. Each time the pump restarts, it will perform self-priming automatically. Users can enter the parameter setting to disable the default self-priming function (see 5.7)

If the default self-priming function is disabled, and the pump has not been used for a long time, the water level in the strainer basket may drop. Users can manually activate the self-priming function by pressing both for 3 seconds, the adjustable period is from 600s to 1500s (default value is 600s). After the manual self-priming is completed, the pump will return to the previous state before activating the manual self-priming.

User can press for more than 3 seconds to exit the manual self-priming.

5.4 Running Capacity Setting

1 Hold for more than 3 seconds to unlock the screen.
2 Press to start. The pump will run at 80% of the running capacity at the

initial startup after the self-priming.
3| | Press or to set the running capacity between 30°4-100%, each step by 5%. For the purpose of backwashing, users can set a high running capacity according to the size of filter.
4| | Hold for more than 3 seconds to read the real-time power.

Note:
a. When the running capacity is adjusted, the system will save the latest parameter automatically.
b.When setting 100% speed, the pump will increase the speed automatically if the pipeline resistance is high, but will not exceed the rated power of each model.

5.5 Timer mode
The pump’s on/off and running capacity could be commanded by timer, which could be programmed daily as needed. Maximum 4 timers can be set on the control panel.

1 Enter timer setting by pressing .
2 Press or to set the local time.

Press to confirm and move to timer-1
3| When enter the timer-1 setting, the timer indicator 1 will light up. “StA”will be shown on the screen.
Press to proceed and then press or to set the start time of timer-1 (with 30 minutes for each step), press to confirm.
4| When the start time of timer 1 is confirmed, “End”will be shown on the screen. Press to proceed and then press or to set the end time of timer-1 (with 30 minutes for each step), press to confirm.
5| When the end time of timer 1 is confirmed, “SPd” will be shown on the screen. Press to proceed and then press or to set the running capacity of timer-1 (30%-100%, each step by 5%), press to confirm.
6| When the timer 1 setting is completed, repeat steps 3 – 5 to complete the setting of timer 2 – 4.

NOTE:
When timer mode is activated, if the set time period contains the current time, the pump will start running according to the set running capacity and the corresponding timer indicator (1 or 2 or 3 or 4) will stay on, and the set running capacity will be shown on the screen. If the set time period does not contain the current time, the timer indicator (1 or 2 or 3 or 4) that isabout to start running will light up and flash, and the current time will be shown on the screen.
All 4 time periods should be set in chronological order.
Overlap setting of time will be considered invalid, the pump will only run based on the previous valid setting.
During the timer setting, if users want to return to the previous setting item, hold both for 3 seconds. If users don’t need 4 timers, they can hold for 3 seconds after completing the setting of the specific timer, the system will automatically save the current set value and activate the timer mode.
When the timer mode is on, users can check the setting of each timer. Press to select the specific timer (1 or 2 or 3 or 4), and the corresponding timer indicator will light up. Then press to check the start time, end time, and running capacity setting of the selected timer.
Users can hold for 3 seconds to read the real-time power and exit timer mode by holding for 3 seconds.

Restore factory setting. Under off mode, hold both for 3 seconds.
Check the software version. Under off mode, hold both for 3 seconds.
Manual priming. Under ON mode, hold both for 3 seconds.
Enter parameter setting as shown. Under OFF mode, hold both for 3 seconds to

enter the parameter setting. The parameter address (on the left) and default setting value (on the right) will flash alternately on
the screen. Users can press or to adjust thecurrent value, and hole both  for 3 seconds to the next parameter address. It will exit the parameter setting after 10 seconds
Parameter Address| Description| Default Setting| Setting Range
---|---|---|---
1| Digital input 2| 100%| 30∼100%, by 5% increments
2| Digital input 3| 80%| 30∼100%, by 5% increments
3| Digital input 4| 40%| 30∼100%, by 5% increments
4| Self-priming/Backwash capacity| 100%| 80∼100%, by 5% increments
5| Enable or disable the priming that occurs at start.| 25| 25: enables
0: disables
6| Self-primming| 2 min| 1-15 min by  1min

EXTERNAL CONTROL

External control can be enabled via following contacts. If more than one external control is enabled, the priority is as below: Digital Input > RS485.

Name| Color| Description| Setting Range| Default Setting
---|---|---|---|---
PIN 1| Red| Digital Input 4| 30-100%, by 5% increments| 40%
PIN 2| Black| Digital Input 3| 30-100%, by 5% increments| 80%
PIN 3| White| Digital Input 2| 30-100%, by 5% increments| 100%
PIN 4| Grey| Digital Input 1| | Pump Stop
PIN 5| Yellow| Digital Ground| | Ground
PIN 6| Green| RS485 A| |
PIN 7| Brown| RS485 B| |

a. Digital input
Running capacity is determined by the state of digital input, (5 pin)
When PIN4 connect with PIN5, the pump will be mandatory to stop; if disconnected, the digital controller will be invalid;
When PIN3 connect with PIN5, the pump will be mandatory to run at 100%; if disconnected, the control priority will be back on panel control;
When PIN2 connect with PIN5, the pump will be mandatory to run at 80%; if disconnected, the control priority will be back on panel control;
When PINT connect with PIN5, the pump will be mandatory to run at 40%; if disconnected, the control priority will be back on panel control;
The capacity of inputs (PIN1/PIN2/PIN3) could be modified according to the parameter setting.

b. RS485
To connect with PIN6 and PIN7, the pump could be controlled via Modbus 485 communication protocol.

ELECTRICAL CABLE REPLACEMENT AND INTERNAL CONNECTIONS

PROTECTION AND FAILURE

8.1 High Temperature Warning and Speed Reduction
During normal operation (except backwash/self-priming), when the pump control system reaches the high temperature warning trigger threshold (178°F), it enters the high temperature warning state; when the temperature drops from the high temperature warning release threshold (172.4°F), the high temperature warning state is released. The display area alternately displays AL01 and running speed or flow.

  1. If AL01 displayed for the first time, the running capacity will be automatically reduced as below:
    a. If current operating capacity is higher than 85%, the running capacity will be automatically reduced by 15%;
    b. If current operating capacity is higher than 70%, the running capacity will be automatically reduced by 10%;
    c. If current operating capacity is lower than 70%, the running capacity will be automatically reduced by 5%.

  2. Suggestion for non-first displayed of AL01: check the module temperature every 2 minutes. Compared with the temperature in the previous period, for every 1-degree Celsius increase, the speed will decrease by 5%.

8.2 Undervoltage protection
When the device detects that the input voltage is less than 197V, the device will limit the current running speed.
When input voltage is less than or equal to 180V, the running capacity will be limited to 70%;
When the input voltage range is within 180V~190V, the running capacity will be limited to 75%;
When the input voltage range is within 190V~197V, the running capacity will be limited to 85%.

8.3 Troubleshooting

Problem Possible causes and solution
Pump does not start. • Power Supply fault, disconnected or defective wiring.

• Fuses blown or thermal overload open.
• Check the rotation of the motor shaft for free movement and lack of obstruction.
• Because of long time lying idle. Unplug the power supply and manually rotate motor rear shaft a few times with a screwdriver.
Pump does not prime.| • Make sure the pump basket is filled with water and the 0-ring of cover is clean.
• Loose connections on the suction side.
• Strainer basket or skimmer basket loaded with debris. •
• Suction side clogged.
• Distance between pump inlet and liquid level is higher than 2m, height of pump installation should be lowered.
Low Water Flow.| • Pump does not prime.
• Air entering suction piping.
• Basket full of debris.
• Inadequate water level in pool.
Pump being noisy| • Air leak in suction piping, cavitation caused by restricted or undersized suction line or leak at any joint, low water level in pool, and restricted discharge return lines.
• Vibration caused by improper installation, etc.
• Damaged motor bearing or impeller (need to contact the supplier for repair).

8.4 Error code

Item Error Code Description
1 E001 Abnormal input voltage
2 E002 Output over current
3 E003 No water Protection
4 E101 Heat sink over heat
5 El 02 Heat sink sensor error
6 El 03 Master driver board error
7 El 04 Phase protection
8 El 05 AC current sampling circuit failure
g El 06 DC abnormal voltage
10 El 07 PFC protection
11 El 08 Motor power overload
12 E201 Circuit board error
13 E203 RTC time reading error
14 E204 Display Board EEPROM reading failure
15 E205 Communication Error
16 E209 Loss of prime

Note:
1. When E002/E101/E103 is displayed, the device will resume working automatically, however when it appears a fourth time,

MAINTENANCE

Empty the strainer basket frequently. The basket should be inspected through the transparent lid and emptied when there is an evident stack of rubbish inside. The following instructions should be followed:

  1. Disconnected the power supply.

  2. Unscrew the strainer basket lid anti-clockwise and remove.

  3. Lift up the strainer basket.

  4. Empty the trapped refuse from the basket, rinse out the debris if necessary.
    Note: Do not knock the plastic basket on a hard surface as it will cause damage

  5. Inspect the basket for signs of damage, replace it.

  6. Check the lid O-ring for stretching, tears, cracks or any other damage

  7. Replace the lid, hand tightening is sufficient.
    Note: Periodically inspect and clean the strainer basket will help prolong its life.

DISPOSAL

Observe all safety and warning information during installation and operation.

DISPOSAL CONSIDERATIONS
The transport and protective packaging has been selected from materials which are environmentally friendly for disposal, and can normally be recycled.
Recycling the packaging reduces the use of raw materials in the manufacturing process and also reduces the amount of waste in landfill sites. Ensure that any plastic wrappings, bags etc, are disposed of safely and kept out of the reach of babies and young children. Danger of suffocation.

DISPOSING OF YOUR ELECTRICAL PRODUCT
Electrical devices marked with this label may not be disposed of in domestic waste at the end of their service life.
Electrical and electronic appliances often contain valuable materials. They also contain specific materials, compounds and components, which were essential for their correct function and safety. These could be hazardous to human health and to the environment if disposed of with your domestic waste or if handled incorrectly. Please do not, therefore, dispose of your old appliance with your household waste.
Please dispose of those materials by contacting your local authorities and ask for the correct method of disposal. Please ensure that your old appliance poses no risk to children while being stored prior to disposal.
By disposing of this product in accordance with the regulations, you protect the environment and the health of those around you from negative consequences.

DIAGRAM

11.1 Exploded view

Explosive
Diagram Code
| Part Name| Quantity
---|---|---
1| T union| 2
2| O-ring (2 7/16×11/64 inch)| 2
3| Union nut| 2
4| Strainer basket| 1
5| O-ring (for Transparent Lid) (5 3/64×1 3/64 inch)| 1
6| Transparent Lid| 1
7| Nut for lid| 1
8| Drain plug| 2
9| O-ring (25/64×1/8 inch)| 2
10| O-ring (2 7/8×9/64 inch)| 1
11| Turntable ring| 1
12| Spring washer| 1
13| Impeller| 1
14| Pump body gasket| 1
15| Stainless-Steel hex head bolt| 8
16| Parallel key| 1
17| Inverter controller| 1
18| Fan cover| 1
19| Cross recess head screw| 3
20| Motor| 1
21| Base| 1
22| Sealplate| 1
23| Mechanical seal| 1
24| O-ring (43/64×7/64 inch)| 1
25| Nut for impeller| 1
26| Diffuser| 1
27| Pump body| 1
28| Reducing Bushing| 2

WARRANTY & EXCLUSIONS

STANDARD CONDITIONS – USA and Canada
Madimack Pty Ltd distributes pool products and provides the following warranties:

STATUTORY RIGHTS
The benefits to the consumer under this warranty are in addition to other rights and remedies of the consumer under the laws in relation to the goods and services to which the warranty relates.
Our goods come with guarantees that cannot be excluded under Australian Consumer Law. You may be entitled to a replacement or refund for a major failure and compensation for any other loss or damage. You are also entitled to have the goods repaired if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

LIMITED WARRANTY
Madimack warrants that its products are free from defects in materials and manufacture for a period of 3 years from the date of purchase, unless otherwise specified.
Please visit www.madimack.com.au for all warranty terms and conditions
Madimack will, at its discretion, repair or replace any product proven to be defective during the warranty period for either materials or manufacture. Alternatively, Madimack will pay the cost of repair or replacement within 90 days of receiving the defective product, subject to unforeseen delays. This warranty is applicable for domestic installations only, is personal to the original purchaser, and does not transfer to any subsequent purchasers.

EXCLUSIONS
To the extent permitted by law, Madimack excludes all statutory or implied conditions and warranties, as well as any other liability that may arise under statute or at law, including without limitation liability for breach of contract, negligence, or any other cause of action.
The following exclusions apply:

  • Incorrect installation or operation of the unit resulting from failure to follow the provided instructions.
  • Damage caused to the due to misuse or any means other than a manufacturer defect. Repairs or servicing performed by unauthorized dealers or service stations.
  • Damage caused by an unauthorized service station repairs.
  • Faults in the machine’s operation caused by the use of non-specified accessories.
  • General wear and tear of consumable items.

LIMITATION OF LIABILITY
To the extent permitted by law, Madimack’s liability under any condition or warranty that cannot be legally excluded in relation to the supply of goods and services is limited to one of the following options:

  • Repairing the goods.
  • Replacing the goods with equivalent products or services.
  • Paying the cost of replacing the goods or providing equivalent products or services again.
  • Paying the costs of repairing the goods.

PROCEDURE FOR WARRANTY CLAIMS
Making a claim
The following steps should be taken when making a warranty claim with Madimack Pty Ltd.

  1. Owners experiencing issues with their system are to contact Madimack Pty Ltd service departments online portal to and provide the requested information, www.madimack.com.au
  2. A service agent will review the provided information and will contact you on the provided phone number to try and solve the issue.
  3. If the issue cannot be dealt with over the phone, owners will be supplied with details of service agent in their area
  4. Owners will need to contact and deal with service agents directly in relation to the booking in and payments of works related to the service or repair of their Madimack Pool Heat Pump.
  5. Owners can claim reimbursement for costs of works covered under the product warranty when completed by an approved Madimack Service Agent. When making a claim, owners will need to provide the following documents.
    – Proof that you are the original system owner original invoice showing owner name and property address. approved service agent.
    – Copy of invoice from an approved Madimack approved service agent.
    – For a major defect a copy of the report for major defects from approved Madimack Service agent.

In the event of a warranty claim, the faulty product should be returned to the place of purchase or, to an authorised service and warranty agent repair centre.
You are responsible for arranging the removal of the defective product and the installation of the repaired or replacement product.
This includes all transportation costs and any applicable insurance fees associated with transporting the products to the supplier and the replaced or repaired product from the supplier.

All returns require Madimack’s written approval and must be accompanied by either:
A service support ticket authorized by Customer Service Manager or Authorised Agent, or A “Return Goods Authorisation”

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals