INTRODUCTION

The new E3 electronic Modulevel incorporates many advances not previously available in a displacer transmitter. This exciting product offers communications via a variety of platforms; three-button keypad and two-line × eight-character LCD display, HART® communications, AMS, PACTware or FOUNDATION fieldbus™. The use of the distinctive Eclipse® dual-compartment angled housing results in a sleek, modernized look, as well as, decreased size and weight. The E3 Modulevel is ideal for retrofitting onto an existing Modulevel or into an existing Modulevel or other manufacturer’s chamber.

E3 Transmitter Head Onto Existing Electronic Modulevel

The E3 transmitter head can be retrofitted onto all existing EZ, Smart EZ, ES II and E3 sensing units. Order part number Z39-4101-Hxx, where the ninth and tenth digits are identical to those of the applicable E3 model number (see bulletin BE 48-135).MAGNETROL-E3-Modulevel-Retrofits-
FIG2

Remove the old transmitter head and install the new head on the existing enclosing tube (see bulletin 48-697). User calibration must be performed with E3 head on old sensing unit.

E31 or E32 Head Into Existing Modulevel Chamber

MAGNETROL-E3-Modulevel-
Retrofits-FIG3

A top mounted E3 Modulevel can be mounted into an existing side/side or side/bottom configuration torque tube chamber.* The unit must be specially modified with a compatible head flange and stem length adjusted for the torque tube chamber. Order model XE31 or XE32, X=torque-tube flange, special stem length. Remove the old torque tube top works and displacer from the chamber and mount the new E3 as you would any top mounted model (see bulletin BE 48-635). Simple configuration must be performed (no calibration required).

E31 or E32 Head Into Existing Torque Tube Transmitter Chamber

A top mounted E3 Modulevel can be mounted into an existing side/side or side/bottom configuration torque tube chamber.* The unit must be specially modified with a compatible head flange and stem length adjusted for the torque tube chamber. Order model XE31 or XE32, X=torque-tube flange, special stem length. Remove the old torque tube top works and displacer from the chamber and mount the new E3 as you would any top mounted model (see bulletin BE 48-635). Simple configuration must be performed (no calibration required).MAGNETROL-E3-Modulevel-Retrofits-FIG5

E3 cannot be retrofit onto a Fisher 249C chamber

BULLETIN N°: BE 48-698.0
EFFECTIVE: DECEMBER 2009
SUPERSEDES: New

EUROPE Heikensstraat 6, 9240 Zele, België -Belgique
Tél. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • info.magnetrolbe@ametek.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals