GDU-Tech K02 Docking Station Instruction Manual
- September 23, 2024
- GDU-Tech
Table of Contents
- K02 Docking Station
- Specifications:
- Product Information:
- Highlights:
- Components of the Docking Station:
- Debug Box Components and Functions:
- Hatch Cover:
- 1. Door Switch Control:
- 2. Position Control:
- 3. Battery Installation:
- 4. Power Supply:
- 5. Forced Start:
- 6. Release:
- 7. Emergency Stop:
- Q: Can minors under 18 use this product?
- Q: What happens when the release button is pressed?
K02 Docking Station
“`html
Specifications:
- Product: Docking Station
- Model: 2024.06
- Type: Automatic Drone Docking Station Management System
Product Information:
Highlights:
The Docking Station is a specialized electronic product designed
for automatic drone docking.
Components of the Docking Station:
- Debug box with various control buttons
- Hatch cover with built-in heating wire for deicing
Debug Box Components and Functions:
-
Door Switch Control: Button to control the
door switch -
Position Control: Button to control the
position of the robot arm -
Battery Installation: Button to put the
battery into the compartment -
Power Supply: Button to control the power
supply of the docking station -
Forced Start: Start the station with UPS power
supply if no mains power -
Release: Button to manually open the hatch
cover -
Emergency Stop: Button for emergency stop
Hatch Cover:
The hatch cover joint includes a heating wire for deicing
purposes at low temperatures.
Product Usage Instructions:
1. Door Switch Control:
Use the button to control the opening and closing of the
door.
2. Position Control:
Press the button to adjust the position of the robot arm as
needed.
3. Battery Installation:
Short press once to lift the robot arm; press again to place the
battery in the compartment.
4. Power Supply:
The docking station can be powered on/off using the power supply
button.
5. Forced Start:
If there is no mains power, use the UPS power supply for
starting the docking station.
6. Release:
To manually open the hatch cover, press the release button.
7. Emergency Stop:
In case of emergencies, press the emergency stop button to halt
all operations immediately.
FAQ:
Q: Can minors under 18 use this product?
A: No, minors under the age of 18 should not use this product
due to safety reasons.
Q: What happens when the release button is pressed?
A: Pressing the release button allows manual opening of the
hatch cover.
“`
Docking Station
User manual
2024.06
Contents
Instructions ………………………………………………………………………………………………………………………………………………. 1
Warning ………………………………………………………………………………………………………………………………………………….1 Disclaimer
……………………………………………………………………………………………………………………………………………… 1
Product Introduction ………………………………………………………………………………………………………………………………… 2
Highlights ……………………………………………………………………………………………………………………………………………….2
Docking Station ………………………………………………………………………………………………………………………………………… 3
List of items …………………………………………………………………………………………………………………………………………… 3 Debug
box ……………………………………………………………………………………………………………………………………………… 4 Emergency stop
……………………………………………………………………………………………………………………………………….4 Hatch cover
……………………………………………………………………………………………………………………………………………. 5 Docking station LED
indicator …………………………………………………………………………………………………………………. 5 Docking station
environment perception …………………………………………………………………………………………………….5 Monitoring
camera and fill light ………………………………………………………………………………………………………………..6 Anemometer
……………………………………………………………………………………………………………………………………………6 Rain gauge
………………………………………………………………………………………………………………………………………………6 Temperature and
humidity sensor …………………………………………………………………………………………………………….. 7 Water immersion
sensor ………………………………………………………………………………………………………………………….. 7 Light sensor
…………………………………………………………………………………………………………………………………………….7 Landing platform
……………………………………………………………………………………………………………………………………..8 Air conditioning system
……………………………………………………………………………………………………………………………8 Docking station RTK
………………………………………………………………………………………………………………………………. 9 Docking station protection
level ……………………………………………………………………………………………………………….. 9
Automatic Drone Docking Station Management System
………………………………………………………………………….. 12
System login ………………………………………………………………………………………………………………………………………….12 Docking
station control …………………………………………………………………………………………………………………………..12
Docking station list ……………………………………………………………………………………………………………………………. 13
Aircraft list ………………………………………………………………………………………………………………………………………..13 Task
list …………………………………………………………………………………………………………………………………………….14 Aircraft control
…………………………………………………………………………………………………………………………………. 14 Route management
…………………………………………………………………………………………………………………………………15 Add a new route
…………………………………………………………………………………………………………………………………15 View route
…………………………………………………………………………………………………………………………………………16 Delete route
……………………………………………………………………………………………………………………………………….16 Task management
…………………………………………………………………………………………………………………………………. 17 Create a new task
………………………………………………………………………………………………………………………………. 17 View tasks
…………………………………………………………………………………………………………………………………………18 Delete task
…………………………………………………………………………………………………………………………………………18 Data center
…………………………………………………………………………………………………………………………………………… 19 View task results
package ……………………………………………………………………………………………………………………19 Delete mission results
package …………………………………………………………………………………………………………….19
Appendix ………………………………………………………………………………………………………………………………………………… 20
Instructions
Warning
Thank you for using this product. This is a specialized electronic product.
Incorrect operation may cause damage to items, personal injury or even death.
The legal consequences caused by this shall be borne by the user. Minors under
the age of 18 shall not use this product. To ensure user experience and your
personal safety, please read the following documents carefully before using
this product: Docking Station User Manual Item List This manual is subject to
update without further notice.
Disclaimer
Before using this product, please carefully read and follow this document and
all safety instructions provided by GDU-TECH, otherwise it may cause harm to
you and the people around you, as well as the product and its surrounding
items. Once you use this product, it will be deemed that you have carefully
read, understood, recognized and accepted all the terms and contents of this
document and all related documents of this product. The user promises to bear
full responsibility for the use of this product and the possible consequences.
The user promises to use this product only for legitimate purposes and agree
to the relevant rules of this clause. GDU-TECH is not responsible for any
damage, injury or any legal liability caused by the direct or indirect use of
this product. For issues not covered in this statement, please refer to the
relevant laws and regulations of the local country. If this statement
conflicts with the relevant laws and regulations of the local country, the
latter shall prevail.
1
Product Introduction
The docking station is a fully automatic unattended operation platform
supporting battery replacement and quick response to operations. The fuselage
has been miniaturized and integrated to include a wide-angle monitoring
camera, anemometer, rain gauge, communication antenna, RTK module, UPS power
supply, etc. The docking station boasts strong environmental adaptability,
with an operating environment temperature of -20 to +50. It has a built-in
lightning protection function, with the protection level up to IP55. Equipped
with a battery replacement module, the drone can automatically replace the
battery to resume operation. In addition, the built-in air conditioning system
can quickly cool the battery. The operation coverage radius is up to 8km. It
weighs about 115kg and occupies less than 1m2, supporting quick installation
and deployment. The Low-Altitude Flight Management Center is a UAV mission
management platform that supports route planning, flight mission settings,
flight information synchronizing, media files uploading and downloading for
live viewing, and remote debugging. The S200 series docking station kit can
make flight operation management efficient and visualized, realizing
unattended operation.
Highlights
Lightweight deployment and convenient operation and maintenance The docking
station has been optimized for miniaturization and high integration, and it
weighs about 115kg and occupies an area of no more than 1m2. It can enter the
elevator and be easily deployed to the roof. Industrial protection, wind and
rain-proof The docking station supports all-weather safe operation, resistant
to wind and rain erosion. It reaches IP55 protection level when closed.
Autonomous battery replacement, rapid response The docking station has an
automatic battery replacement module, supporting continuous operation without
interruption. In case of emergency, it can quickly replace the battery and
take off. Remote control, easy replacement During the autonomous flight
operation, users can switch to manual flight mode in the low-altitude flight
management center, or Tapfly, and Point of Interest, Quickfly. Empower the
industry with open API The docking station system supports open Cloud API,
which can be called by developers, greatly empowering application scenarios in
various industries.
2
Docking Station
List of items
RD D
P
WRDSIE LP
3
Debug box
Debug box’s component names and functions
SLCoigrcchkutenitinswg iatrcrhester
Debug box button name Door Return to center
Battery installation
Reset Power supply
Forced start
Release
Component function Button to control the door switch Button to control the position Short press once, the robot arm rises; short press again, put the battery into the battery compartment The robot arm returns to the initial zero position Button to control the docking station power switch The docking station can be started only with UPS power supply when there is no mains power supply When the release button is pressed, the hatch can be opened manually
Emergency stop
The docking station has an emergency stop button. When performing equipment
maintenance and debugging, in case of emergency, press the emergency stop
button to stop the docking station movement mechanism from running to ensure
personal safety. If the aircraft motor is not started and the emergency stop
button is pressed, the aircraft in the docking station will not be able to
perform the flight mission. After the aircraft takes off, press the emergency
stop button, the aircraft will complete the flight operation and then land at
the alternate landing point.
· When the emergency stop button is pressed, you need to pull it out or rotate
it clockwise to release the emergency stop button before continuing other
operations (such as controlling the hatch, etc.).
Emergency stop button
4
Hatch cover
The hatch cover joint has a built-in heating wire, which automatically starts
heating at low temperatures to assist in deicing the hatch cover joints.
Built-in heating wire
Docking station LED indicator
LED indicator
Description
Green light solid on
Docking station status normal
Red light solid on
Docking station status abnormal
Red light flashes
Aircraft abnormal alarm
Green light flashes
Aircraft is performing a mission
Red, blue and green flash alternately
lights
During the takeoff mission, prompt the user to stay away
Red, blue and green flash alternately
lights
During the precise landing, prompt the user to stay away
Blue light flashes
Aircraft battery is charging
Docking station environment perception
The docking station integrates a variety of environmental sensors to obtain
environmental information such as wind speed, rainfall, temperature and
humidity, light, and water immersion to ensure safe operation.
5
Monitoring camera and fill light
The docking station is equipped with 2 monitoring cameras and 1 fill light 1.
Monitoring camera: it is used to monitor the docking station site conditions
in real time. Users can view the environment inside and outside the docking
station in real time on the UVER interface, and it can assist operators to
remotely observe weather conditions, site environment and aircraft take-off
and landing performance, etc. 2. Camera fill light: it automatically turns on
at night or in low light to assist the aircraft in visual identification.
Monitoring camera Fill light
Monitoring camera
Anemometer
The anemometer is used to monitor the wind conditions around the docking
station, with a heating function to adapt to low temperature environments.
Users can view real-time wind speed on UVER. To ensure flight safety, flight
operations are forbidden when the wind speed exceeds the threshold.
· The anemometer can only measure the environmental wind conditions at the
docking station installation location, which is different from the information
of the local meteorological department. The wind speed and direction may
change suddenly after the aircraft flies to high altitude. Be careful when
flying in strong winds.
Rain gauge
The rain gauge is used to monitor the rainfall information at the docking
station location. Users can view the rainfall information on the UVER
interface. To ensure flight safety, flight operations are forbidden when the
rainfall is too heavy.
6
· The rain gauge has a built-in pressure sensor. Do not hit the surface of the
rain gauge hard to avoid damaging the pressure sensor.
· Clean and maintain the surface of the rain gauge regularly. If there are
pits or deformations, repair them in time.
· If there is a vibration source near the docking station (such as near the
railway, it may cause the rain gauge to falsely report rainfall. When
selecting a site, avoid strong vibration sources and noisy areas.)
Anemometer
Rain gauge
Temperature and humidity sensor
The docking station is equipped with an ambient temperature sensor to detect
the air temperature and humidity of the docking station environment; the cabin
has a built-in temperature and humidity sensor, and the location is shown in
the figure below. The temperature and humidity information can be viewed on
the UVER interface.
To ensure flight safety, flight operations are forbidden when the ambient
temperature outside the cabin is below -20°C. The aircraft can resume
operation after the ambient temperature outside the cabin restores.
Water immersion sensor
The docking station is equipped with a water immersion sensor to detect
whether the docking station is flooded. If the UVER interface shows a water
immersion alarm, the docking station will be prohibited from performing tasks.
In addition, a professional needs to go to the site to disconnect the docking
station power supply, clean up the water, and then close the power supply
after checking that it is normal. If there is still a problem at the docking
station, make sure to disconnect the power switch and contact technical
support.
Temperature sensor Water immersion sensor
Light sensor
7
The docking station is equipped with a light sensor to detect the lighting
environment of the docking station site. In a low-light environment, the fill
light will be turned on to assist in precise landing.
Light sensor
Landing platform
1. Air conditioning inlet and outlet: Wipe and clean the air conditioning
outlet and inlet regularly to avoid dust blockage. 2. Nose direction mark:
When placing the aircraft on the apron, the nose direction must be consistent
with the arrow on the apron, otherwise the aircraft will be damaged. 3. Visual
identification mark: There is a visual identification mark on the apron, which
can help the aircraft identify the docking station location for landing.
Please ensure that the identification mark is not blocked or dirty.
Flight platform Nose direction
Cooling vents
Air conditioning system
The docking station has a built-in air conditioning system that can
automatically adjust the temperature and humidity inside to provide a suitable
storage environment for the aircraft and batteries. When the highest
temperature in the battery compartment is higher than 40°C, the cooling system
will be turned on, and when the highest battery temperature is lower than
35°C, it will be
8
turned off. When the lowest battery temperature is lower than 8°C, the heating
system will be turned on until the lowest temperature is higher than 15°C.
Users can Check and turn on/off the air conditioner through the UVER
interface.
Docking station RTK
The docking station RTK base station can achieve centimeter-level positioning
accuracy. To ensure accurate flight along the set route, make sure that the
docking station RTK has been calibrated before performing flight missions.
When installing and configuring the docking station, calibrate the docking
station RTK parameters through the embedded web page. After successful
calibration, there is no need to re-calibrate again unless the docking station
position changes.
· During the operation of docking station RTK (such as setting an alternate
landing point or the aircraft performing a high-precision RTK mission), do not
move the docking station position, restart the docking station, or recalibrate
the docking station position.
· During the active or flickering ionosphere, the RTK positioning accuracy may
be affected. It is not recommended to calibrate the docking station position.
RTK module
Docking station protection level
1. The docking station is used with the aircraft and tested under controlled
laboratory conditions to achieve the IP55 protection level under the IEC60529
standard. The protection level is not permanent and may decrease due to wear
and tear after long-term use. Please perform regular maintenance. 2. The
following conditions may compromise the IP55 protection level: The power
distribution cabinet door is not closed; The anemometer fixing screws are not
tightened, the hatch is not closed; Other possible damage to the fuselage,
such as cracked shell.
9
1. Professional installation must be justified in the filing, and grant condition must state
“This device must be professionally installed.”
Description: Device is DOCKING STATION and must need special trained
professional in configurating and installing the product. More details please refer to
user manual exhibits.
2. Professional installation does not permit use of any antenna with the transmitter;
the permitted types of antenna must be specified.
Description: Below listed of Antennas has been compliance FCC Rules Part 15
requirement, more details please refer to test reports.
Antenna Type
Connector
Antenna Gain (dBi)
2400-2500MHz
5700-5850MHz
Dipole
R-N Type
2.68
3.14
3. The applicant should address the following items when justifying professional
installation.
i)
To qualify for professional installation, the applicant must explain why the
hardware
Description: Due to this product will not be sold directly to the general public
through retail store therefore the hardware is not readily available to average
customer.
ii) Marketing–Device cannot be sold via retail to the general public or by mail
order; it must be sold to authorized dealers or installers only
Description: Due to this product will not be sold directly to the general public
through retail store. It will be sold to authorized declarers or install only.
iii) Filing must show that intended use is not for consumers and general public;
rather device is generally for industrial/commercial use.
Description: Device is for industrial/commercial use.
iv) Explain what is unique, sophisticated, complex, or specialized about the
equipment that REQUIRES it to be installed by a professional installer?
Description: Please be advised that due to the unique Market and function
targeted by this product. this product will need special trained professional
in selecting the proper location, adjusting the antenna anele on the outside
pole or on the wall to satisfy the relevant rule requirements, We hereby
declare that the product will be distributed through controlled distribution
channel which has special trained professional to install this product and will
not be sold directly to the general public through retail store.
4. Other professional installation requirements
(1) Installation must be controlled.
Description: The product will be distributed through controlled distribution
channel which has special trained professional to install this product.
(2) Installed by licensed professionals (e.g., device sold to dealer who hire installers).
Description: Device sold to dealer who hires installers and need special trained
professional in configuring and installing the product.
(3) Installation requires special training (e.g., special programming, access to keypad,
field strength measurements made). Description: The product needs special programming. access to keypad. field strength measurements made, so must need special trained professional in configuring and installing the product.
Automatic Drone Docking Station Management System
System login
Users should use a browser to access the docking station management system,
enter the assigned account password and enterprise number, and then enter the
verification code to log in.
Docking station control
The docking station control interface is the homepage of the UAV automatic
airport management system. The main functions include docking station viewing
and control, aircraft viewing and control, mission execution status and
operation, etc.
12
Docking station list
Click the “Docking Station List” button and the docking station list will pop
up. Users can click on the docking station they want to view and enter the
docking station details page to view the docking station operation status,
docking station monitoring screen or control the docking station.
Aircraft list
Click the “Aircraft List” button and the docking station list will pop up.
Users can click on the aircraft they want to view to view the aircraft’s
current operating status, flight parameters and realtime video.
13
Task list
The task list contains all route tasks. When you need to manually execute a
route, you can go to the manual task to execute it. When you need to check the
execution status of a regular task, you can go to the regular task to check
it.
Aircraft control
When a docking station (aircraft online) or online aircraft is selected, the
user can control the current aircraft. The platform supports the following
functions: one-key takeoff, emergency hovering, Tapfly, precise return, and
control authorization.
14
Route management
The route management module supports functions of planning, managing, storing,
importing and exporting routes. The platform provides users with a variety of
route types to meet different flight operation scenarios. And control, mission
execution status and operation, etc. Add a new route Click the “New Route”
button to enter the page for adding a new route.
When adding a new route, first draw the route on the map, then configure the
route information and waypoint information on the left, and click OK after
completion.
15
View route
Click the route card to view the route planning and route information on the
right map and the information bar below.
Delete route
Click the route card expansion button and the expansion menu will pop up, and
then click the “Delete” button to delete the route.
16
Task management Create a new task a) Click the “Create a new task” button in
the task management interface to enter the task planning
module.
b) In the new mission interface, fill in the mission name, execution docking
station, execution route,
execution method, etc. After all are filled in, you can select the execution
time and add the execution date to the mission calendar.
17
View tasks
The task list supports docking station and route filtering. Click on the task
card to display the route and task execution information of the task execution
on the map.
Delete task
Enter the details page and delete all flights to delete the task.
18
Data center View task results package
The collected results are packaged according to the mission sorties,
supporting the screening of docking station and routes. Click to enter the
next level to view the photos of the mission results package.
Under the results list, click on the details to view the large picture.
Delete mission results package
Users can click “Delete” in the list or in large image mode 19
Appendix
Main parameters of docking station
Appearance
Size
Hatch closed: 1030mm×710mm×860mm (excluding rain gauge, weather
station, antenna)
Hatch open: 1600mm×710mm×860mm (excluding rain gauge, weather station, antenna)
Weight
115kg ± 1kg
Number of controllable drones 1
External fill light
Support
Docking station status indicator Support
Operation capability
Mains power supply
100VAC – 240VAC, 50/60HZ
Power consumption
Peak power consumption 1500W
Deployment scenario
Ground, roof, tower
Emergency battery
5h
Battery replacement time
2min
Operation interval time
3min
Maximum number packs allowed
of
battery 4 groups (3 groups as standard)
Battery compartment function
charging
Support
Precise landing at night
Support
Data storage
Support
RTK Base station
Support
Maximum inspection range
8km under unobstructed and interference-free conditions
Wind resistance
Inspection process: Level 6 (12m/s) Precise landing process: Level 5 (8m/s)
Cloud manual takeover
The cloud of the drone docking station can be manually taken over, so that users can remotely control the drone through the docking station. You can control the drone in the following actions: upward, downward, left rotation, right rotation, forward, backward, left flight, right flight, load control, shooting, start recording, end recording.
20
Power failure protection
After the docking station power supply is cut off, the drone cannot take off. If the drone has taken off, the mission will be interrupted and it will return.
Precise landing
Support
Automatic alternate landing
Support
Jump fly function
The drone can be operated between two or more docking stations
Breakpoint resume
During the inspection process, if the mission is interrupted due to abnormal conditions and the drone returns, it can take off again and continue the inspection mission from the breakpoint.
Precise positioning
Support
Remote upgrade
Support remote upgrade of docking station, drone, and drone battery firmware
Industrial protection
Working environment temperature range
-20 – +50
Maximum working altitude
5000m
External environment relative <95%, it can work normally humidity
Antifreeze
Support hatch heating
Dust and waterproof level
IP55
Lightning protection
Support
Salt spray protection
Support
Drainage
Support
Vibration protection
Support
Proof against small animals and insects
Support
Environmental perception
Outside temperature
Support
Outside humidity
Support
Outside rain monitoring
Support
Outside wind monitoring
Support
Inside temperature monitoring Support
Inside humidity monitoring
Support
21
Light sensor Smoke monitoring Vibration sensor Water immersion monitoring External camera Internal camera Communication method Network port 4G Open interface API
Support Support Support Support Support (1080P, night vision) Support
Support 10/100 Mbps adaptive Ethernet port access Router Support (SIM card
required)
Support
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any inte rference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interferenceto radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
-Reorient or relocate the receiving antenna.
·Increase the separation between the equipment and receiver.
·Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
·Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
22
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>