PHILIPS CertaFlux LEDFlex Light Installation Guide
- September 23, 2024
- Philips
Table of Contents
PHILIPS CertaFlux LEDFlex Light
Product Specifications
- Connector: IEC60838-2-2 compliant
- Usage: Indoor use only
- Bending Radius: Not less than 30mm
- Cleaning: Soft dry cotton cloth recommended, no chemical solvents
Product Usage Instructions
Installation
- Clean the installation surface
- Remove release paper from the lighting strip
- Stick the lighting strip onto the surface
- Fix the strip in place using clips or screws, adding a group of clips per meter for fixation
Connector Installation
- Cut the light strip neatly and keep the whole pad intact
- Remove release paper and tape from the connector
Wire Soldering
- Cut the light strip neatly and pre-treat bare wire of connecting wire for soldering
- Solder the wires together
Maintenance
To ensure optimum performance, clean the product regularly with a soft dry
cotton cloth (recommended twice a year). Avoid using chemical solvents.
Attention: Always shut off the power supply before mounting or
maintaining the lighting strip. The lighting strip must be installed by a
qualified electrician and wired according to IEE electrical regulations or
national requirements. Do not cover the strip with thermal insulation.
Thermal Design
For proper thermal design and cooling, refer to the product datasheet and
follow the recommended guidelines for ambient operating temperature and Tc
life values.
Frequently Asked Questions (FAQ)
-
Can I use chemical solvents to clean the lighting strip?
No, using chemical solvents can damage the surface of the lighting strip. It is recommended to clean it with a soft dry cotton cloth only. -
What should I do in case of operation failure?
In case of operation failure, switch off the power and contact your nearest Philips dealer for assistance. -
Can I cover the lighting strip with thermal insulation?
No, the lighting strip should not be covered with thermal insulation or similar material under any circumstance.
Please read this manual carefully before using the product
The manufacturer will not be held responsible for improper usage or
modifications of the product,
Connector must in accordance with IEC60838-2-2.
Indoor use only.
Operation instruction
- Please take anti-static measure during installation and maintenance.
- In case of operation failure, please switch off the power and contact your nearest Philips dealer.
Maintenance
-
In order to ensure optimum performance, please clean the product regularly (recommended twice a year). When cleaning the product, please use soft dry cottoncloth only.
-
Do not use chemical solvents to clean the lighting strip, it might damage the surface.
Attention- Please shut off the power supply before mountIng and maintaining lighting strip!
- The lighting strip shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
SAFETY INSTRUCTION
LEDFlex Installation
Connector Installation
Connector Disassembly
Wire Soldering
Thermal design
Cooling
The LEDFlex modules have a relatively small footprint in relation to their
electrical and thermal power. A good thermal contact via the 3M™ tape to an
adequate heat sink, is a necessity for a good luminaire. To make good contact
a certain pressure should be applied during installation. When applying
pressure to the LEDFlex take care not to damage the electronics by exerting
force on them and avoid ESD of more than 2kV. The heat sink surface must be
smooth and free of burrs to obtain optimal contact. The heat sink should not
be locked up in a confined space. It should be in contact with the ambient air
for optimal heat transfer to the ambient.
Drivers
- If placed in the luminaire drivers are preferably placed as far away as possible from the modules to prevent heating interaction. If placed in a separate driver compartment they are preferably mounted on the inner surface of the compartment. Do not place the driver on a heat sink that is used for cooling the modules. If so, it will be heated by the thermal losses of the LED –modules.
- To warrant the lifetime of the driver, two parameters are key:
- Ambient operating temperature. The ambient operating temperature is given in the product datasheet.
- Tc life: The temperature measured at the Tcase point of the LEDFlex module is located on the top side. Please refer to the datasheet for the exact Driver Tcase point location and Tc life value.
Self cooling
- In many cases the LEDFlex is self cooling, meaning it does not require a heatsink. Below you find an indicative table of self cooling LEDFlex products when mounted as can be seen in picture 3.
- The self cooling values are an indication only and should alway be verified by a Tc measurement. The self cooling indication is given for a setup indicated in the below picture (picture 3). Where the optical efficiency of the cover is 85%.
Self cooling table