citronic SilentPAR-216 RGBWA Plus UV Silent PAR Can User Manual
- September 20, 2024
- citronic
Table of Contents
citronic SilentPAR-216 RGBWA Plus UV Silent PAR Can
USER MANUAL
SilentPAR-216
RGBWA+UV Silent PAR Can
Item ref: 154.065UK
Please read through this manual thoroughly before use, any damage Caused by misuse of product will not be covered by warranty.
Premium build quality and cutting-edge design combine to provide a wide range of brilliant colours from this Citronic SilentPAR light effect. The whisper quiet fan ensures the near to silent operation of 18 x 12W RGBWA+UV CREE SMD LEDs with minimal heat emission. Easily control the unit’s internal auto, sound activated and static programs via the control panel on the back or by using 6, 8 or 11 channel DMX connection if preferred. The heavy-duty metal chassis and stand/bracket offer strength and solidity and the twist and lock power connections on the back, finish off the SilentPARs professional appearance and performance.
In the box:
Your SilentPAR should arrive with you in a single carton in good condition. The carton should contain
- 1 x main unit,
- 1x stand/mounting bracket and thumbscrews,
- 1 x UK twist and lock mains lead and
- 1 x user guide.
Warning:
To prevent risk of fire or electric shock, do not expose the unit to rain or damp environments. In the event of a spillage, disconnect the mains and allow the unit to dry out naturally. Qualified personnel should then check the unit before continuing use.
Please do not open cover, contains high voltage. This product is not serviceable or repairable by the end user. Please refer to qualified personnel for service and repair.
Placement:
- Keep away from damp or dusty environments.
- Ensure adequate airflow around the fixture housings.
- Ensure adequate access to controls and connections.
Cleaning:
- Use a soft cloth with a neutral detergent to clean the casing as required.
- Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups.
- Do not use strong solvents for cleaning the unit.
Side panel controls:
1. LCD display
2. Manual control buttons
3. Power input (twist and lock)
4. Power output (twist and lock)
5. DMX input
6. DMX output
Manual control menu:
Press the “MENU” button to enter the settings menu.
Press “UP” and “DOWN” buttons to navigate through various setting functions.
Press “ENTER” button to save the desired setting.
Mode | Programming | Description |
---|---|---|
Auto mode | Auto | SP 01-20 |
of all effects
St 00-19| Strobe0-19 (slow->fast)
DMX mode| Addr| 6 CH| A001-A507
8 CH| A001-A505
11 CH| A001-A502
Show| Shou| Sh 01-12| Program show 1-12 (built in effects)
SP 01-20| Program speed 1-20 (slow->fast)
St 00-19| Program strobe 0-19 (slow->fast)
Sound Mode| Soud| Sou1-3| 3 Sound-activated
Modes| Sound-activated mode can adjust sensitivity
Sen1-9| Sound-activated
sensitivity adjustment
Slave| SLAV| Slave| Slave (Slave, automatic recognition Master)
Edit color| Colo| r000-r255| Red (0-100%)
g000-g255| Green (0-100%)
b000-b255| Blue (0-100%)
U000-U255| White (0-100%)
A000-A255| Amber (0-100%)
P000-P255| UV (0-100%)
St 00-19| Strobe (slow->fast)
Static colors| StAt| CL01-CL28| Static colours 1-28
Product Set| Set| dis| 10s| Set the backlight time of the display board to 10
seconds until it stays on continuously, with a factory default of 10 seconds
20s
30s
60s
on
temp| 50-65 C| Set the protection temperature within the range of 50-65℃, the
lamp will then begin to reduce power if it exceeds the set
temperature
Send| yes| One click to set the channel mode of all
lighting fixtures to the current master’s channel mode
Send
Information| Info| ver| VVxx| Soft version
temp| XX C| Current light panel temperature(℃)
DMX mode:
The SilentPAR can be controlled by DMX signal, simply connect the DMX signal
source to the DMX input on the unit via a balanced XLR lead. Extra fixtures
can be controlled by the same DMX signal by looping through the DMX out on the
unit. To enter DMX mode, select Addr from the menu and confirm the correct
start address by using the “UP” and “DOWN” buttons and “ENTER” to confirm.
This unit has 6, 8 or 11 DMX channels as indicated in the table below:
6 Channel mode:
Channel | Value | Function and description |
---|---|---|
CH1 | 0-255 | Red dimming (0-100%) |
CH2 | 0-255 | Green dimming (0-100%) |
CH3 | 0-255 | Blue dimming (0-100%) |
CH4 | 0-255 | White dimming (0-100%) |
CH5 | 0-255 | Amber dimming (0-100%) |
CH6 | 0-255 | UV dimming (0-100%) |
8 Channel mode:
Channel | Value | Function and description |
---|---|---|
CH1 | 0-255 | Master dimmer |
CH2 | 0-9 | No Function |
10-255 | Slow->Fast | |
CH3 | 0-255 | Red dimming (0-100%) |
CH4 | 0-255 | Green dimming (0-100%) |
CH5 | 0-255 | Blue dimming (0-100%) |
CH6 | 0-255 | White dimming (0-100%) |
CH7 | 0-255 | Amber dimming (0-100%) |
CH8 | 0-255 | UV dimming (0-100%) |
11. Channel mode:
Channel | Value | Function and description |
---|---|---|
CH1 | 0-255 | Master dimmer |
CH2 | 0-9 | No function |
10-255 | Slow->Fast | |
CH3 | 0-14 | CH11 CCT |
15-29 | Static colour (CH4 select) | |
30-44 | Built in effect1 | |
45-59 | Built in effect 2 | |
60-74 | Built in effect 3 | |
75-89 | Built in effect 4 | |
90-104 | Built in effect 5 | |
105-129 | Built in effect 6 | |
120-134 | Built in effect 7 | |
135-149 | Built in effect 8 | |
150-164 | Built in effect 9 | |
165-179 | Built in effect 10 | |
180-194 | Built in effect 11 | |
195-209 | Built in effect 12 | |
210-224 | DMX auto, recycle running built-in effect 1~12 | |
225-239 | DMX sound 1 | |
240-254 | DMX sound 2 | |
255 | DMX sound 3 | |
CH4 | 0-255 | DMX program speed (Slow->fast) |
CH5 | 0-255 | Red dimming (0-100%) |
CH6 | 0-255 | Green dimming (0-100%) |
CH7 | 0-255 | Blue dimming (0-100%) |
CH8 | 0-255 | White dimming (0-100%) |
CH9 | 0-255 | Amber dimming (0-100%) |
CH10 | 0-255 | UV dimming (0-100%) |
CH11 | 0-7 | CH5-CH10 Dimmer |
8-255 | CCT (When CH3<15 is active) |
Specifications:
Power | 100 – 240Vac, 50/60Hz |
---|---|
Power consumption | 300W |
LED power | 18 x 12W RGBWA+UV CREE SMD LEDs |
DMX channels | 6, 8 or 11CH |
Beam angle | 28° |
Connections | Power in/out (twist and lock), DMX in/out (3pin XLR) |
Dimensions | 118 x 220 x 220mm |
Weight | 2.75kg |
Troubleshooting:
No power (mains)| Check mains lead and fuse (if fuse continually blows, refer
to your dealer)
---|---
No light output| Check control panel mode settings
Check DMX settings from controller (dimmer levels, blackout etc.)
Unresponsive to DMX| Check that unit is in DMX mode and ensure DMX address
remains lit to confirm receiving DMX signal
Check DMX controller is not set to black out
Check DMX controller is on correct fixture/page
Check master dimmer value
Check correct DMX address is set
Check DMX connection and leads
Overheating/cutting out| Ensure adequate ventilation and unit is not too close
to a heat source
Errors and omissions excepted.
Copyright© 2024 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
AVSL (Europe) Ltd, Unit 3D North Point House,
North Point Bus. Park, New Mallow Road, Cork, Ireland.
154.065UK User Manual
Frequently Asked Questions (FAQ)
Q: Can I service or repair the product myself?
A: No, this product contains high voltage and should only be serviced or repaired by qualified personnel.
Q: How do I adjust sensitivity in Sound-activated mode?
A: You can adjust sensitivity in Sound-activated mode by using the sensitivity adjustment feature.
Q: What is the default display board backlight time?
A: The default display board backlight time is set to 10 seconds.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>