MOTORWERK 103303808 Evse Type 2 11kW
INTRODUCTION
Motor werk EVSE Type 2 11kw light and compact portable charger for home, work trips, cabins etc. Very easy to use because no fixed installation is required. Connects directly to a power socket (CEE 3x16A / 400V) and the device automatically charges with 11kw power. The power is enough to fully charge the car overnight. IP rating 66, so the use of the charger is worry-free even in bad weather.
FEATURES
- Charging power 11 kW (16A), Not adjustable
- Type 2 charging plug, CEE wall plug
- Total length: 6 m
- A smart LED indicator on the charger and plug shows the charging status Type A AC residual current protection + 6 mA DC residual current protection Leakage, overvoltage, under voltage, overheating and lightning protection Material ABS + PC plastic shell
- Power consumption in standby mode less than 3W
- IP66 of the charging unit
- Charging plug IP66
- Operating temperature: -25 to +50 °C
- CE approved
- Color black
- Weight: 3.2 kg
- Warranty: 24 months
PRODUCT IMAGE AND INTERFACE DESCRIPTION
STRUCTURAL COMPOSITION AND ELECTRICAL SCHEMATIC DIAGRAM
The charging box includes the input power supply plug, control panel,
indicator panel, and output electric vehicle charging connector plug.
The charging control panel offers protection against overload, short circuit
and leakage; the output relay controls the on-off of the power supply; the
connector provides the charging interface connected with the electric vehicle,
equipped with locking device and anti misoperation function.
The signal light will show status of “standby”, “in charging” and “fault”;
TECHNICAL PARAMETERS
Specifications | Model | Type2 11kw 5m 6438014378619 |
---|---|---|
Technical Specifications | Certificate | CE\FCC\RoHS |
Appearance material | Product name | Wassenberg EVSE |
Shell material | ABS+PC plastic shell | |
External Dimension | 26110765mm | |
Weight | 3.2kg | |
Electrical indicators | input voltage | 400V AC Three-phase |
input current | 16A | |
input frequency | 50Hz | |
Maximum power | 11kW | |
Output voltage | AC 400V | |
Output current | 16A | |
Standby Power Loss | ≤3W | |
Standard | EN 62752 | |
Warranty | 24 months | |
Environmental indicators | Applicable scene | Outdoor / ln door |
Operating temperature | -25C-+55C | |
Operating humidity | 5%-95% | |
Applicable altitude | <2000m | |
lP Class | lP66 | |
Cooling mode | Natural cooling | |
Safety protection | Over current protection | Yes |
Short circuit protection | Yes | |
Leakage protection | Yes | |
Grounding protection | Yes | |
Over temperature protection | Yes | |
Anti-thunder protection | Yes | |
Human computer interaction | LED light | Yes |
CHARGING STATE INDICATOR
Charging state| Disconnected Mode| Connected Mode| Charging
Mode| Finish Mode| Fault Mode
---|---|---|---|---|---
lndicator Light| Upper green on
| All green on
| Rolling
| All green on
| Flashing red on
Display Status of the LED indicator light
Fault code | Cause of failure | Display mode |
---|---|---|
1 | CP fault | Fault code 1 |
2 | Low voltage | Fault code 2 |
3 | Over voltage | Fault code 3 |
4 | Ungrounded | Fault code 4 |
5 | Over current | Fault code 5 |
6 | Short circuit | Fault code 6 |
7 | Leakage | Fault code 7 |
8 | Board over temperature | Fault code 8 |
About the fault code: when there’s a red light flashing, it means fault in the system, and the fault code number is the same as the times the red light flashes. The red light stays off for a while after flashing.
For example, for fault code 5: the red light flashes five times quickly, then stays off for three seconds, and then flashes 5 times again, then stays off for three seconds, and goes on like this. When there are multiple faults, it’ll only display one fault code.
When there’s a short circuit protection fault or a leakage fault, the charging will not continue, which can be recovered only after the charging plug is unplugged and plugged in again; for other faults, it doesn’t need such operation, and the charging will be resumed automatically after the fault is recovered.
OPERATING INSTRUCTIONS
Quick Operation Guide
- Insert the inlet wire plug into the power supply socket, the ,green light is on (Disconnected), then the start-up is completed;
- Plug in the charging connector, the green indicator1ight (Connected) is on;
- Then it will automatically start charging, and the green indicator light (Charge) will start rolling;
- When you need to end the charging just pull out the charging connector.
- Note: The socket wire harness must be over 2.5 mm2
PRECAUTIONS FOR USE
- Note! The charger must not be used with a CEE -> Shako adapter!
- Failure to follow the instructions may result in danger;
- Please use the charging station when the operational condition is technologically normal and safe;
- Prevent children from touching the charging station;
- Install a charging station away from pyrotechnics , dust and corrosive occasions;
- The output of the charging station is high voltage, so you must keep yourself safe in the process;
- If a fault has occurred, there might be a risk of getting electric shock or even death. Please cut off the power supply under emergency situations;
- Do not remove the plug from the wall outlet while charging is in progress
MAINTENANCE
The product is packed in the factory. Strong impact and collision should be avoided during transportation to avoid damage to the outer packaging of the product. The product should be placed at an ambient temperature of -40Ԩ+ 70Ԩ and a relative humidity of no more than 95%. The ambient air should not contain acids, alkalis or other corrosive gases and explosive gases, and it should be protected from rain, snow, wind and sand.
SAFETY WARNING
- Failure to follow the instructions may result in danger!
- Please regularly check whether the charging station has visible damage. There may be a risk of getting electric shock if operating a damaged charging station.
- Make sure that all safety facilities are available at all times and test regularly to ensure proper operation.
- If a ground fault occurs, it must be assumed that the base’s cable carries the voltage, and after confirming that no high-voltage power is available in the system, check the charging station.
- Installers and users must observe the principles and regulations to guarantee their safety and equipment safety.
- Before powering up the equipment, please make sure that the equipment is properly grounded to avoid unnecessary accidents.
- All the tools that do not require exposed metal parts should be insulated to prevent exposed metal parts from touching the metal frame and causing a short circuit.
- Do not modify, refit, or change any part by yourself under any circumstance.
- Ensure the service life and stable operation of the charging station. The operating environment
- should be kept as clean, homo-thermal and constantly humid as possible. The charging station must not be used in the presence of volatile gas or flammable atmosphere.
- Make sure that the input voltage, frequency, circuit breakers and other conditions have already met the specifications before powering up the equipment.
- The charging device may only be used in a fault current protected socket.
WARRANTY SERVICES
a) Warranty Condition
When the product leaves the factory, the user completely abides by the
storage, installation and use rules specified in this instruction manual yet
still finds quality issues.
After the product leaves the factory, the user opens the package and finds
that the product or supporting parts are damaged due to transportation
problems.
b) Warranty Period
Product warranty lasts for 24 months after the user receives the product.
c) Warranty Method
During the warranty period, the manufacturer is responsible for free
replacement or repair.
Beyond the warranty period, the user shall negotiate with the manufacturer to
replace or repair the product in a paid way.
This manual is subject to any change without notice.
If there’s any inconsistency between the real product and the content
described in this manual, the real product shall prevail.
Customer Support
Suomi Trading Oy
Areenakatu 7, 37570 Lempaala
asiakaspalvelu@suomitrading.fi
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>