Eeese-Aircare 2590 Dehumidifier Felix User Manual
- September 18, 2024
- Eeese-Aircare
Table of Contents
User manual
Dehumidifier Felix
Art. 2590
2590 Dehumidifier Felix
Thank you for choosing this product.
Please read this instruction manual before using it.
Read the user manual before use, refer to the corresponding section of these
user instructions.
Recycle unwanted materials instead of disposing of them. All appliances and
packages must be sorted and delivered to a regional recycling centre and
processed in an environmentally friendly manner.
The product complies with the applicable EU directives and other provisions.
This unit uses a flammable refrigerant.
If the refrigerant leaks and comes into contact with fire or heating elements,
it will produce harmful gas and pose a fire risk
Safety instructions
Warning
The refrigerant circuit is sealed. Only a qualified technician should attempt
to service the unit!.
Safety Guidelines
Intended Use : This appliance is designed for use by experts or trained
individuals in shops, light industries, farms, or for general commercial use.
It is not suitable for aggressive environments such as pigsties, pool rooms,
etc.
It can also be operated by children aged 8 and above, and by persons with
limited physical, sensory, or mental capabilities, provided they are
supervised and have been instructed on safe use and understand the risks.
Child Safety : Children should not play with the appliance. Do not allow
children to perform cleaning or maintenance without adult supervision.
Refrigerant: This unit must only be operated with R-290 (propane) gas.
The refrigeration system is sealed and should only be serviced by a qualified
technician. Do not release the refrigerant into the atmosphere.
Propane Safety: R-290 is flammable and heavier than air. It tends to
accumulate at low levels and can be dispersed by fans. If you suspect that
propane gas is present, do not allow anyone without proper training to
investigate the cause of the leak. The propane used in this unit is odorless;
absence of smell does not mean absence of gas.
Leak Procedure: If a leak is suspected, evacuate the area immediately,
ventilate the room, and contact the local fire department. It is not safe to
return until a qualified technician has resolved the issue and confirmed that
it is safe.
Ignition Sources: Avoid open flames, smoking, or any potential ignition
sources near the appliance.
Component Safety: Parts of this unit are specifically designed to be non-
incendiary and non-sparking for use with propane. Always replace parts with
identical spare parts specified by the manufacturer.
Precautions Before Use
Power Cord Safety: If the power cord is damaged, it must be replaced by
the manufacturer, a service agent, or a similarly qualified person to prevent
hazards.
Power Disconnection: Disconnect the appliance from the power source
during maintenance.
Appropriate Power Supply: Use only a power source with the voltage,
frequency, and classification specified on the product’s identification plate.
Grounded Outlets: Always use a grounded outlet.
Unplugging: Unplug the appliance from the outlet when cleaning or when
not in use.
Handling: Do not operate the appliance with wet hands or allow water to
spill on it. Avoid exposing the unit to rain, moisture, or any liquids.
Monitoring and Placement: Never leave the appliance turned on unattended.
Do not tilt or turn over the appliance.
Connecting and Disconnecting: Do not unplug the appliance while it is in
use, and always pull on the plug, not the cord.
Extension Cords and Adapter Plugs: Do not use extension cords or adapter
plugs.
Surface and Contact: Avoid placing objects on top of the appliance and do
not climb or sit on it. Keep fingers and other objects away from the air
outlet, and do not touch the air inlet or aluminum fins.
Damage and Malfunction: Do not use the appliance if it has fallen, is
damaged, or is functioning improperly.
Cleaning: Only clean the appliance with recommended products and avoid
harsh chemicals.
Placement: Place the unit away from sources of fire, flammable materials,
or explosives and ensure it is installed in accordance with national
installation regulations.
Defrosting and Maintenance: Use only the manufacturer’s recommended
methods for defrosting and cleaning the appliance.
Storage: Store the appliance in a well-ventilated area away from
continuous heat sources such as open flames or active heaters. Ensure it is
protected from mechanical damage.
Ventilation: Keep all necessary ventilation openings clear of
obstructions and store in a room where the size corresponds to the specified
operating area.
Refrigerants and Safety: Be aware that refrigerants may not have any
odor. Protect piping from physical damage, and do not install it in an
unventilated space that is smaller than 6 m².
Important
If the unit has been lying horizontally, wait one hour before using it.
Overview of the Unit
Features
- The Hot Gas Valve system enhances performance in low temperature situations.
- Includes a timer: 1-24 hours.
- Equipped with a foldable handle for easy operation.
- Fitted with sturdy wheels suitable for moving up and down stairs.
- Stackable for storage, saving space.
- The rear air outlet allows for connection to an air duct system.
- Features a humidity setting function: from 20% to 90%.
- Designed with a continuous drain outlet.
Parts list
Components
-
Foldable handle
-
Control panel
-
Air intake with filter
-
Wheels
-
Access to pump
-
Water hose
-
Latch for handle
-
Air outlet
-
Cable holder
-
Nameplate
-
Water hose connection
-
Basket
Control Panel -
Up button
-
Water full indicator
-
Water pump button
-
Power on/off button
-
Timer button
-
Defrost indicator
-
Down button
Display on the Control Panel -
Operating time in hours
-
Humidity setting / timer
-
Incoming air temperature °F/°C
-
Incoming humidity
-
Outgoing air temperature °F/°C
-
Outgoing humidity
Continuous Draining
-
Before turning on the dehumidifier, connect the included water hose. The hose is equipped with a coupling that fits the dehumidifier’s water hose connection.
-
Locate the nearest drain.
The dehumidifier’s pump can handle a height of up to 5 meters, which is convenient when water needs to be pumped out of a basement. -
Turn on the dehumidifier. The unit will now dehumidify until the tank is full, after which it will automatically pump out the water for 30 seconds.
Operating Instructions
Powering the unit on/off Press the ‘POWER’ button to turn on the unit.
Press the ‘POWER’ button again to turn off the unit; it will shut down after
one minute. The unit will then go into standby mode.
Timer Function Turning off the unit
When the unit is on, you can press the timer button to set when the unit
should turn off. Using the “UP” and “DOWN” buttons, the timer can be set
between 1 and 24 hours. A dot (A) next to the time indicates if the timer is
active. The timer is reset by setting the time to 00.
Turning on the unit
When the unit is off, you can press the timer button to set when the unit
should turn on. A dot (A) next to the time indicates if the timer is active.
The timer is reset by setting the time to 00.
Humidity Setting Function Setting
The unit can be set to a humidity level between 20% and 90% (A). Press the
‘UP’ and ‘DOWN’ buttons to set the desired humidity level in the room. When
the desired humidity level is reached, the unit will automatically stop
dehumidifying. It will restart automatically if the room humidity exceeds the
set value.
When the built-in tank is full, the water pump starts and operates for 30
seconds until the tank is emptied.
Automatic Dehumidification
When the humidity at the air intake is equal to or higher than the set
humidity threshold +3%, and the compressor is not in a 3-minute delayed start
protection period, the fan will start immediately, and the compressor will
start 3 seconds later.
When the humidity at the air intake is equal to or lower than the set humidity
threshold -3%, the compressor will stop immediately, and the fan will stop 1
minute later.
Water Pump Function Always make sure to press the ‘PURGE’ button before
turning off the dehumidifier when you know that the unit will no longer be
used and needs to be packed away. This function activates the water pump,
which empties the water tank in the unit and prevents potential water damage.
IMPORTANT!
After completing the dehumidification, make sure to empty the unit’s water
tank by pressing the ’PURGE’ button.
Defrosting The defrost indicator lights up when the unit begins to
defrost. This typically happens because the ambient air temperature is low. In
the defrost mode, the dehumidifier stops dehumidifying. The unit will
automatically continue dehumidifying once it has finished defrosting.
Full Water Tank When the integrated water tank is full, the ‘FULL’
indicator lights up. Three seconds later, the water pump automatically starts
running.
Temperature Display The temperature displayed is in Fahrenheit (°F)(A) by
default. Switch to Celsius (°C) by holding down the ‘POWER’ button for five
seconds while the unit is on.
Operating Time The unit displays the operating time in hours. The time
cannot be reset.
Memory
If a power outage occurs, or the device turns off, it will automatically
restart with the same settings as before.
Cleaning
Ensure that the appliance is turned off and disconnected before maintenance
and cleaning.
The dehumidifier should not be submerged in water or any liquid. Do not use
abrasive, corrosive, or flammable cleaning agents (such as bleach or alcohol)
to clean any part of the appliance.
- Ensure that the dehumidifier is turned off and disconnected.
- Use a soft cloth with a neutral cleaning agent to remove dust or dirt from the surface of the unit and the air intake/outlet. Avoid getting water into the unit when cleaning the air outlet.
- If the filter is blocked by dust, the dehumidifying effect will be reduced. Clean it twice a week.
a. Remove the filter. It can easily be pushed out to the side from the right with one finger (A). b. Clean the filter with a vacuum cleaner or with water (max 40°C). Avoid exposing the filter to high temperatures or placing it in direct sunlight to dry.
c. After drying, reinstall the filter.
Storage
- Press the purge button to empty the water before storing the unit.
- Ensure that the unit is turned off and disconnected.
- Use a soft cloth with a neutral cleaning agent to remove dust or dirt from the surface of the air intake/outlet.
- Once the dehumidifier is completely dry, move the unit and store it upright in a dry and cool place with good ventilation.
- If there are multiple units, they can be stacked on top of each other.
Troubleshooting
Check the following before contacting technical support:
Error Code | Cause | Solution |
---|---|---|
El | Fault in the copper head sensor | Needs to be replaced |
E2 | Fault in the air intake temperature and humidity sensor | Needs to be |
replaced
E3| Fault in the air outlet temperature and humidity sensor| Needs to be
replaced
FL| Fault in the water pump, or the water tank for the pump is full.| Press
‘PURGE” if it doesn’t work, con-tact customer service
IMPORTANT!
Do not attempt to repair the dehumidifier yourself as it may pose a risk.
Technical Specifications
Model Felix, Rem No. | 2590 |
---|---|
Max. Working Area, m2 | 170 |
Capacity at 30°C/RF 80% I/day | 70 |
Capacity at 27°C/RF 60% I/day | 40.5 |
Power (in operation) W | 720 |
Power Supply V/Hz | 220-240/50 |
Air Flow Volume, m3/h | 390 |
Timer hours | 1 – 24 |
Noise Level dB (A) | 555 |
Refrigerant | R290 / 0.250 kg |
Drainage Method | Water pump /Continuous drainage |
Water Tank, I | 11 |
Operating Temperature °C | 5 – 35 |
Filter | Washable |
Pump Height Capacity Hmax, m | 5 |
Drain Hose Included | Yes |
Drain Hose Length, m | 6 |
Cable Length, m | 7.6 |
Net Weight, kg | 46 |
Gross Weight, kg | 53 |
Cable Length, cm | 175 |
Product Dimensions (WxDxH) mm | 481 x 547 x 813 |
Packaging Dimensions (WxDxH) mm | 576 x 602 x 875 |
The above technical data is for reference only. We reserve the right to change them without notice.
Service
If you require service or it is a matter of a warranty claim, please create a
case directly in our support system. Visit the SUPPORT section on our website.
https://eeese-aircare.com/support
IMPORTANT!
If you need technical assistance, contact our customer service: https
://eeese-aircare.com/support/
We have specialized knowledge about our products and the field, so you can
receive help easily and quickly.
Warranty
Limited Warranty
We guarantee that all parts are free from manufacturing defects in
materials and workmanship for a period of one year from the date of purchase.
The warranty covers only material and manufacturing defects that prevent the
product from being installed or functioning normally.
Defective parts will be replaced or repaired.
The warranty does not cover transport damage, use of the product other than as
intended, damages caused by improper assembly or misuse, damages caused by
impacts, shocks or other faults, damages due to frost cracks or accidents, or
damages caused by improper storage.
The warranty will be void if the user makes modifications to the product.
The warranty does not cover consequential damages, property damage, or loss of
operation otherwise.
The manufacturer’s liability shall not exceed the repair or replacement of
defective parts and does not include labor costs to remove and reinstall the
defective part, transportation costs to and from the service workshop, or any
other materials necessary for the repair.
This warranty does not cover operational failures or defects resulting from:
- If the unit is not installed, operated, or maintained in accordance with the instructions provided with the unit.
- The craftsmanship of any installation of the unit.
- Abuse, modification, accident, fire, flood, lightning, rodents, insects, negligence, or un- foreseen actions.
- The use of non-factory authorized parts or accessories in connection with the product.
- Components subject to normal wear and tear, such as the air filter, are not covered by the warranty.
Limitation of Liability
This is the only warranty provided by the manufacturer. No one is authorized
to issue any other warranties on our behalf.
This warranty supersedes all other warranties, expressed or implied,
including, but not limited to, any implied warranty of fitness for a
particular purpose and merchantability. We expressly disclaim any liability
for consequential, incidental, indirect, or punitive damages resulting from
the breach of express or implied warranties. This warranty gives you specific
legal rights, which may vary by country.
Claims
In the event of a claim, a valid purchase receipt must be presented. Read
about how to make a warranty claim in the SERVICE section.
IMPORTANT!
If you need technical assistance, contact our customer service: <https
://eeese-aircare.com/support/>
We have specialized knowledge about our products and the field, so you can
receive help easily and quickly.
Responsible Disposal
This symbol indicates that this product should not be disposed of with general household waste. This applies throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed of in a responsible manner. When recycling your product, take it to your local collection facility or contact the place of purchase. They will ensure that the product is disposed of in an environmentally sound manner.
Warning on Refrigerant R290
The machine is designed only for use with R290(propane) gas as the designated
refrigerant.
Note: The refrigerant loop is sealed. Only a qualified technician should
attempt to service.
The lack of smell does not indicate a lack of escaped gas. No open flames,
cigarettes or other possible sources of ignition should be used in the
vicinity of the machine. Component parts are designed for propane and non-
incentive and non-sparking. Component parts shall only be replaced with
identical repair parts.
Note: The machine may only be installed in a room with a minimum floor
area of 4m2.
R290 is a flammable gas that is heavier than air. On this basis, if the gas
leaks from the unit, the concentration will be the highest at ground level.
However, the gas can be lifted (e.g. by draught, fan, etc) to higher levels.
The R290(propane) used in this unit has no odour. Do not use the machine in a
room with an open flame, other high-level heat sources (e.g. cigarettes,
candles, etc.) or electrical discharges. Install the machine in a room which
can be ventilated when necessary and where gas accumulation is not possible.
If R290(propane) is detected in the room, or a leak is suspected, do not allow
unauthorized persons to search for the source of the leak. In such cases,
evacuate all people from the room, open the windows, leave the room and notify
your local fire department to advise them that a propane leak has occurred. Do
not allow any person to return to the room until the commanding officer of the
fire department or a certified service engineer decides that the risk has
ceased to exist.
Thank you for choosing this product.
Please read this instruction manual before using it.
eeese air care . info@eeese-aircare.com
Web: eeese-aircare.com
MV-2590-07-2024
Documents / Resources
|
Eeese-Aircare 2590 Dehumidifier
Felix
[pdf] User Manual
2590 Dehumidifier Felix, 2590, Dehumidifier Felix, Felix
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>