BITMAIN HK3V6 BTC Miner Instruction Manual

September 18, 2024
BITMAIN

BITMAIN-Logo

BITMAIN HK3V6 BTC Miner

Product Information

The ANTSPACE AZ (Antifreeze) is designed to help maintain the proper operating temperature of equipment. It is essential to follow the guidelines provided in the product manual to ensure safe and effective use.

Specifications:

  • Product Name: ANTSPACE AZ (Antifreeze)
  • Version: V1 Sept. 2024
  • Manufacturer: BITMAIN TECHNOLOGIES INC.
  • Website: www.bitmain.com.

Product Usage Instructions

  1. Pre-Installation:
    Before using the antifreeze, ensure all product components are present. Contact BITMAIN if any parts are missing. Carefully inspect the product before installation.

  2. Installation:
    Follow the installation instructions provided in the product manual. Ensure correct installation to prevent damage and ensure optimal performance.

  3. Usage:
    Operate the product within the specified environmental conditions outlined in the manual. Avoid exceeding the recommended scope of use and adhere to international standards and regulations.

  4. Maintenance:
    Regular maintenance is essential for product longevity. Follow maintenance guidelines provided in the manual to keep the product functioning efficiently.

Frequently Asked Questions

Q: What should I do if I purchased the product from a non-BITMAIN official sales channel?

A: In such cases, BITMAIN does not guarantee full transmission of the product manual. It is recommended that the seller provides training and services related to installation, use, and maintenance.

Q: Is repair covered under warranty?

A: Repair services may be provided at a cost if the damage is not covered by the warranty, such as exceeding the free warranty period or incorrect product usage.

Q: Can I use software not provided by BITMAIN with this product?

A: It is advised to use only the software provided or recommended by BITMAIN to ensure compatibility and optimal performance of the product.

Declaration

The purpose of the Product Use and Maintenance Manual (hereinafter referred to as the product manual) is only to provide guidance information to help you correctly use the antifreeze. Before installing and using this product for the first time, you are obligated to carefully read all the materials delivered, especially the precautions mentioned in the product manual, which will help you better and safely use this product. Please keep the product manual properly for future reference. Before using this product, please check if the product components are complete. If there are any missing parts, please contact BITMAIN promptly and carefully inspect the product before installation and use.

When the following situations cause property damage to you or third-party personnel, BITMAIN will not be responsible, and the product damage caused is not covered by the warranty. If the user requests repair services, after being determined by the BITMAIN service organization, paid repair services can be provided.

  • The entire equipment and components of this product have exceeded the free warranty period, or have been damaged due to abnormal use or natural environment.
  • Incorrect or failure to install, use, and store this product according to the instructions and requirements of the product manual.
  • Operate this product under operating environmental conditions that exceed the requirements specified in the product manual.
  • Exceeding the installation and use scope specified in international standards or local laws, regulations, and industry regulations.
  • Repairs or changes to this product by non-BITMAIN authorized technical personnel;
  • Use the software provided with the product outside of this product, or use other software other than nonrandom software or specialized software on this product.
  • Other scenarios that do not require liability within the legal scope of the country (region) where the operation is carried out.

Special attention:
If the user purchases this product from a non-BITMAIN official sales channel, BITMAIN does not guarantee that the product manual can be fully transmitted. Training and services related to installation, use, maintenance, etc., should be provided by the seller. When using this product, it is assumed that the user is aware of the relevant installation, use, and maintenance content of the product, which also applies to the content of this declaration.

The product manual is not intended to indicate that BITMAIN has made any promises or warranties regarding its products and services, whether express or implied, including but not limited to the warranties of suitability, safety, and suitability for a specific purpose recommended in the product manual. The photos, graphics, charts, and illustrations provided in the product manual are for explanatory and explanatory purposes only, and may differ from the actual product. The actual specifications and configurations of the product may change from time to time as needed, so they may differ from the content of the product manual. Please refer to the actual product purchased.

Due to the continuous iteration of products and the application of new designs, materials, and technologies, BITMAIN will make improvements or modifications to the software and hardware described in the product manual and the content of the product manual at any time based on factors including but not limited to product characteristics, product performance, and usage environment, without prior notice. If you find any inconsistencies between the actual situation of this product and the product manual during use, or if you want the latest information or have any questions or ideas, please feel free to call us or log in to the service website for inquiries.

Change History

Versio n| Change items| Before changing| After changing| Change time| Change by
---|---|---|---|---|---
V1.0.0| Initial version|  |  |  |

Copyright © BITMAIN TECHNOLOGIES INC. All rights reserved.
Without the authorization of BITMAIN, the relevant contents of this manual shall not be spread, copied or forwarded to a third party, nor uploaded to a third-party platform such as the public network.

Trademark

  • As well as other BITMAIN and ANTSPACE trademarks used in this manual, they belong to BITMAIN TECHNOLOGIES INC.
  • All other trademarks or registered trademarks mentioned in this manual belong to their respective owners.

Software Authorization

  • It is prohibited to use part or all of the data in the firmware or software developed by our company for commercial purposes in any way.
  • Prohibit decompilation, decryption, or other operations that disrupt the original program design of the software developed by our company.

BITMAIN TECHNOLOGIES INC.

About This Document
This manual mainly introduces the working principle, fault handling, and maintenance methods of the ANTSPACE AZ V1 antifreeze.

Application Scope
This manual applies to the ANTSPACE AZ V1 model.

Intended Audience
This manual applies to professional technical personnel who need to install, operate, and maintain the product. Professional technical personnel must meet the following requirements:

  • Possess certain professional knowledge in electronics, electrical wiring, and machinery, and be familiar with electrical and mechanical schematic diagrams.
  • Familiar with the composition and working principles of liquid cooling systems and related products.
  • It should have received professional training related to the installation and trial operation of electrical products.
  • It should have the ability to respond urgently to hazards or unexpected situations that occur during installation or trial operation.
  • Familiar with the relevant standards and specifications of the country/region where the project is located.

Use of Manual
Please read the manual carefully before using the product. The content of the manual will continue to be updated and corrected, but there may inevitably be slight discrepancies or errors with the actual product. Users should refer to the actual product they purchased and can download or obtain the latest version of the manual materials through www.bitmain.com or sales channels.

Symbol Conventions
To ensure the personal and property safety of users when using the product, and to use the product more efficiently and optimally, the manual provides relevant information and highlights it with the following symbols.
The following are the symbols that may be used in this manual. Please read carefully to better use this manual.

  • Danger
    Indicates a high potential danger that, if not avoided, could result in serious accidents such as personal injury, equipment damage, etc.

  • Warning
    Indicates a moderate potential hazard, which, if not avoided, could result in serious accidents such as equipment damage.

  • Caution
    Indicates a potential danger that, if not avoided, may result in the equipment not functioning properly.

Safety Description

General Safety Instructions

DISCLAIMER:
The equipment company is not responsible for any of the following situations.

  • Operation beyond the conditions specified in this document.
  • Usage under installation and operating environments which are not specified in related international specifications.
  • Failure to follow the operation instructions and safety precautions on the product and in the document.
  • Damage caused by abnormal natural environments.
  • All Safety Instructions
    To ensure the safety of humans and the equipment, pay attention to the safety symbols on the equipment and all the safety instructions in this document.
    The “CAUTION”, “WARNING” and “DANGER” marks in this document do not represent all the safety instructions. They are only supplements to the safety instructions.
  1. Local Safety Regulations
    When operating the equipment, you must follow the local laws and regulations. The safety instructions in this document are only supplements to the local laws and regulations.

  2. Personal Requirements

    • Only trained and qualified personnel are allowed to install, operate, and maintain BITMAIN equipment, and they must understand basic safety precautions to avoid hazards.
    • Only trained and qualified personnel are allowed to install, operate, and maintain BITMAIN equipment.
    • Only personnel certified or authorized by the equipment provider are allowed to replace or change the equipment or components (including software).
    • Any fault or error that might cause safety problems must be reported immediately to a supervisor.
  3. Grounding Requirements
    Equipment to be grounded must meet the following requirements:

    • When installing the device, always make the ground connection first and disconnect it at the end.
    • Do not damage the ground conductor.
    • Do not operate the equipment in the absence of a properly installed ground conductor.
    • Ensure that the equipment is connected permanently to the protective ground.
  4. Personal Safety

    • Keep irrelevant people away from the equipment. Only operators are allowed to access the equipment.
    • Before operating a device, wear insulated shoes and insulated gloves, and pay attention to eye protection. Remove conductive objects such as jewelry and watches to avoid electric shocks or burns.
    • Ensure that tool handles are insulated.
  5. Equipment Safety

    • Put away the keys to the device when installation, operation, and maintenance.
    • Before operations, ensure that the equipment is firmly secured to the floor or other solid objects, such as a wall or an installation rack.
    • Do not block the ventilation while the device is operating.
    • Tighten the screws by using a tool after initial installation and subsequent access to the panel.
    • After the installation, remove packing materials from the equipment area.

Electrical Safety

  1. High Voltage
    Danger
    The high-voltage power supply provides power for the operation of the equipment. Direct contact or indirect contact with the high-voltage power supply through wet objects (or conductors) is fatal. Irregular and incorrect high-voltage operations may cause accidents such as fire or electric shock. Signal wires should be tied separately from high-current wires or high-voltage wires.

  2. High Electrical Leakage
    Danger

  3. Before timing on se postal all component safety willie endanger the general grounding wire must

  4. If a “large leakage current” sign is pasted near the power terminal of the equipment, the protective grounding terminal of the equipment chassis must be grounded before connecting to the AC input power supply to prevent the equipment’s leakage current from causing electric shock to the human body.

  5. Exposed cables in the equipment should be insulated immediately.

  6. Power Cable
    Danger
    It is prohibited to install or remove the power cord while the power is on. The moment the power cord core comes into contact with a conductor, arcs or sparks will occur.

    • Before installing or removing a power cable, turn off the power switch.
    • Before connecting a power cable, check that the label on the power cable is correct.
    • If the power cable is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
    • The appliance should fit with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions, and these means must be incorporated in the fixed wiring under the wiring rules.

Mechanical Safety

  1. Drilling Holes
    Warning
    It is prohibited to drill holes in the cabinet by yourself. Drilling holes that do not meet the requirements will damage the internal components or pipelines of the equipment and damage the internal cables.

  2. Sharp Objects
    The fins of the heat exchanger of dry tower are extremely sharp. Please wear protective gloves when operating close to the fins.
    Warning
    When carrying the equipment by hand, you should wear protective gloves to prevent your hands from being cut by the sharp corners of the equipment.

  3. Fan

    • When replacing a component, place the component, screws, and tools in a safe place. Otherwise, if any of them fall into the operating fans, the fans may be damaged.
    • When replacing a component near fans, do not insert your fingers or boards into the operating fans until the fans are switched off and stops running.
  4. Moving Heavy Objects
    Warning

  5. Please wear protective gloves when carrying heavy objects to avoid scratching your hands.

  6. When carrying heavy objects, be prepared to bear the weight to avoid being crushed or sprained by heavy objects.

  7. When pulling the equipment out of the cabinet, be careful because the equipment installed on the cabinet may be unstable or heavy to avoid being crushed or hit.

  8. It is prohibited for one person to carry heavy equipment alone. When transporting the device, do not tilt the device more than 15° (relative to vertical).

  9. When moving or lifting the equipment, please protect the equipment to avoid scratches or bumps.

  10. When transporting, it is strictly prohibited to use the components as a supporting point to prevent damage to the components.

Operation Safety

  1. High Temperature and Pressure
    Misoperations may occur over high pressure, which may result in an eruption of coolant. Pay attention to high-pressure parts: exhaust valves and drain valves.

  2. High-Speed Running
    Pay attention to the high-speed running part: fan.

Others

  1. Binding Signal Cables
    Caution
    Bundling signal wires should be bundled separately from high-current wires or high-voltage wires.

  2. Laying Out Power Cables

  3. When the temperature is very low, a violent strike or vibration may damage the power cable sheathing. To ensure safety, comply with the following requirements:

  4. Power cables can be laid or installed only when the temperature is higher than 0˚C.

  5. Before laying out power cables that have been stored at a temperature lower than 0˚C, move the power cables to an environment of the ambient temperature and store them at the ambient temperature for at least 24 hours.

  6. Handle power cables with caution, especially at a low temperature. Do not drop the power cables directly from the vehicle.

  7. Storage

    • Do not store devices near a heat source or under direct sunshine.
    • Keep devices away from fire or high-temperature objects, especially devices injected with pressurized nitrogen or refrigerant; otherwise, explosion or refrigerant leakage may occur, causing personal injury.
  8. Recovery and Disposal
    The sign indicates that the product cannot be disposed of with other wastes that have a shell in European Union (EU) areas. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.

Antifreeze Product Introduction

Appearance of Antifreeze
The following is the appearance of the antifreeze product packaging.

BITMAIN-HK3V6-BTC-Miner-Fig-1

Antifreeze Product Parameters

Table 3.1 Antifreeze product parameters

Indicators Parameter Unit
Color Blue/Red clear liquid /
Odor Asexual odor /
pH 8.0~9.0 /
Conductivity 2400-4000 µS/cm
Reserve alkalinity >2.5 mL
Turbidity <1 NTU
Freezing point -40
Glycol volume concentration 53% /
Density 1.070-1.078 kg/L
Thermal conductivity@20℃ 0.352-0.406 W/m.K
Specific heat capacity@20℃ 3.190~3.229 kJ/kg.K

Correspondence Between Antifreeze Concentration and Freezing Point
When the product is used in an environment where the lowest freezing point temperature is high, to avoid heat dissipation, the antifreeze can be diluted according to the following table. To ensure the long-term reliability of the antifreeze, the minimum dilution volume concentration cannot be less than 10%.

Table 3.2 Relationship between antifreeze glycol concentration and freezing point

Glycol volume concentration% Freezing point ˚C
0 0
5 -1.6
10 -3.7
15 -6.1
20 -8.9
25 -12
30 -15.4
35 -20.3
40 -25.3
45 -31.1
50 -36.4
55 -44.2
60 -54

Antifreeze Concentration Dilution Instructions
If the antifreeze needs to be diluted, please refer to the following steps:

In the field, a container (a ton of barrels that can be used to store antifreeze) should be prepared for dilution. After the antifreeze is injected into the container according to the dilution ratio, the deionized water is added in proportion to mix evenly, and the freezing point of the diluted antifreeze is sampled and detected. Refer to Table 3.2 Relationship between antifreeze glycol concentration and freezing point. For example, if it needs to be diluted 5 times, 1 portion of antifreeze and 4 portions of deionized water are added to the container respectively, and the freezing point is tested after mixing evenly.

Caution

  1. To ensure that the environment is clean and tidy during dilution, the equipment must be cleaned with deionized water ;
  2. We must strictly control the dilution ratio;
  3. During the dilution process, wear gloves and pay attention to personnel safety.

Please refer to the following table for the quality of deionized water used to dilute antifreeze.

Table 3.3 Recommended standards for deionized water

Index

| Deionized water| Reference standards|

Remarks

---|---|---|---
pH| 5.0-7.5| GB/T6682-2008|
Conductivity| ≤5μS/cm| GB/T6682-2008|
Turbidity| <1NTU|  |
Sulfide| <1ppm| TC9.9/Intel 632983|
Sulfate| <1ppm|  |
Chloride| <1ppm|  |
Total hardness (as

CaCO3)

| <1ppm|  |
Bacterial community| <100CFU/mL| TC9.9/Intel 632983|
Residues after

evaporation

| ≤2.0mg/L| GB/T6682-2008|
Iron content| <1ppm| Industry standards|
Copper content| <1ppm| Industry standards|
Carbon steel corrosion

rate

| 3mpy(0.075mm/a)| GB/T 50050-2017|
Corrosion rate of copper

or stainless steel

| 0.2mpy(0.005mm/a)| GB/T 50050-2017|

Test Report and Certificate

Basic physical and chemical performance test report、metal compatibility test report non-metal compatibility test report, safety data sheet (SDS), marine cargo transportation conditions appraisal, coating and coating compatibility test report.

BITMAIN-HK3V6-BTC-Miner-Fig-2

Instructions for Use

Storage Condition
Closure of packaging containers. Store in a cool and ventilated area to avoid direct sunlight.

Caution
Store in a cool and ventilated area to avoid direct sunlight.

Packing Specification
The product has one packaging size: 1000L.

Table 5.1 Parameters of 1000L Specification

Specifications Parameter
length 1200±10 mm
width 1000±10 mm
Belt tray height 1160±10 mm
rough weight 1131±0.5 kg

Shelf Life
Hold for 3 years when unopened.

Instructions for Use

  • Please ensure that the air tightness of the liquid cooling system is in good condition before liquid injection;
  • Injecting antifreeze, please refer to the water cooling container product manual for operation methods.;
  • Periodically sampling and testing the parameters (such as pH, concentration, etc.) of circulating coolant in a liquid cooling system;
  • Pay attention to the liquid level in the rehydration tank. If the liquid level is insufficient, please replenish the long-life coolant in time and check whether the liquid cooling system leaks to ensure the safe operation of the liquid cooling system.

Warning

  • Do not drink and swallow, which may be harmful. Immediately induce vomiting and seek medical examination in time;
  • When accidentally touching your eyes, immediately rinse with plenty of water and seek a medical examination in time.

Service Life
When used with BITMAIN’s container products, the service life can be guaranteed to be 3 years. During the service life, the physical and chemical properties of the long-lasting liquid cooling medium remain stable and will not cause serious corrosion to the container components.

Waste Disposal
Dispose of contents/containers by local/regional/national/international regulations.

Sampling Detection

  • It is recommended to carry out the first sampling test within 24 ~ 72 hours after the system starts up and runs.
  • Sampling and testing are recommended every 6 months in operation.

Table 6.1 Reference Indicators for Long-term Operation of Antifreeze

Metric

| Parameter|

Unit

---|---|---
pigment| Significant color| /
smell| Asexual odor| /
pH| 7~9| /
turbidity| <10| NTU
total numbers of colony| <1000| CFU/mL
copper| <50| mg/L
silicon| <20| mg/L
aluminum| <50| mg/L
iron| <50| mg/L
boron| <20| mg/L
Phosphorus| <20| mg/L
Molybdenum| <20| mg/L
Calcium| <20| mg/L
chloridion| <50| mg/L
sulfate radical| <100| mg/L
total hardness| <120| mg/L

BITMAIN TECHNOLOGIES INC.
www.bitmain.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals