IRISBOND 2024 Hiru Eye Tracking System User Manual
- September 17, 2024
- IRISBOND
Table of Contents
- 2024 Hiru Eye Tracking System
- Specifications
- Product Usage Instructions
- Hiru First Steps Overview
- Using with Different Operating Systems
- USB Connection and Mounting
- Assembly Options
- Q: Can the Hiru eye tracker work with both Windows and
- Q: What are the minimum system requirements for using the Hiru
- Q: How do I calibrate the Hiru eye tracker for optimal
2024 Hiru Eye Tracking System
“`html
Specifications
-
Compatibility: Windows and iPadOS
-
Minimum Requirements:
- CPU: 1.33 GHz
- RAM: 8GB
- Storage: 128GB
- USB: 3.0 -C
- Graphics: Intel, Nvidia, and others with OpenGL 2.0
support
-
Multiplatform: Works with Windows and iOS
(iPad) -
Positioning: Optimum working distance of 55
cm
Product Usage Instructions
Hiru First Steps Overview
-
Install Systray program for required drivers and updates.
-
Download and install eye gaze communication software (e.g.,
Easyclick, Grid 3). -
Connect Hiru using the provided cables.
-
Calibrate in your Eye Gaze Software for optimal
experience.
Using with Different Operating Systems
The same eye tracker can be used with Windows and iPadOS. Follow
the specific connection instructions for each operating system.
USB Connection and Mounting
Depending on the device being used:
- For Windows devices, use the provided long C-A cable.
- For iPad Pro, an A-C adaptor is needed along with the long
cable.
Assembly Options
The Hiru system is adaptable for use with laptops, Desktop PCs,
and tablets:
-
Laptop: Fix the Hiru under the laptop or PC
onto the holder using the provided screws. -
Watch the Set Up video for IRISBOND Hiru
FAQ
Q: Can the Hiru eye tracker work with both Windows and
iPadOS?
A: Yes, the Hiru eye tracker is compatible with both Windows and
iPadOS.
Q: What are the minimum system requirements for using the Hiru
eye tracker?
A: The minimum requirements include a CPU of 1.33 GHz, 8GB RAM,
128GB storage, and USB 3.0 support.
Q: How do I calibrate the Hiru eye tracker for optimal
performance?
A: Calibrate the Hiru in your Eye Gaze Software to adapt it to
your eyes for the best experience.
“`
Hiru The only eye-tracker that works in Windows and iPadOS, indistinguishably
User Manual | Quick Start Guide: Windows
August 2024
User manual IRISBOND Quick Start Guide: Windows
User Manual IRISBOND Hiru Eye Tracking System
IRISBOND CROWDBONDING, S.L. All rights reserved.
This document, including all supporting materials, is proprietary to IRISBOND
CROWDBONDING, S.L.
As this document may contain information that is confidential, proprietary, or
otherwise legally protected, it must not be further copied, distributed, or
displayed without the express written permission of IRISBOND CROWDBONDING,
S.L.
Products that are referred to in this document may be either trademarks and/or
registered trademarks of the respective owners. The publisher and the author
make no claim to these trademarks.
Contact Information IRISBOND CROWDBONDING, S.L Tolosa Avenue 75, 2nd floor
20018 Donostia-San Sebastián, Gipuzkoa, Spain +34 943 496 622
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
What are you looking for?
IRISBOND Hiru Eye tracker
Hiru First Steps Overview
1
Compatibility
2
Multiplatform
2
Positioning
2
USB Connection and mounting
3
Assembly Options
4
How to mount Oskol
7
Use with different Operating Systems: Overview
8
How to update Hiru in Windows
9
Compliance Information: CE and MDR Declaration of conformity (MDR) Technical Specifications
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
1
Hiru First Steps Overview
Install Systray This program includes the Drivers and updates needed for Hiru.
Download and install eye gaze communication software (examples: Easyclick, Grid 3).
Connect Hiru Use the provided cables.
Calibrate in your Eye Gaze Software! Calibrating lets the Hiru adapt to your eyes so you have the best experience.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
2
If you want to use the eye tracker with larger screens, you can do so by changing the position of the camera and placing it further away from the screen.
Compatibility
Minimum requirements CPU 1,33 GHz RAM 8GB Storage: 128GB USB 3.0 -C
Intel Graphics Nvidia and others with OpenGL 2.0
Multiplatform
Hiru eye tracker can be used both with Windows and iOS (iPad). The same eye
tracker works with both operating systems.
We recommend iPad Pro / Surface Windows Pro
iPadOS
Windows
iPad Pro 12.9″ 5th and 6th generation Windows 7-11 Pro iPad Pro 11″ 3rd and 4th generation
Positioning
Optimum working distance 55 cm.
Optimum screen size 10″ 20″ inches
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
3
USB Connection and mounting
Depending on the device that you may be using, an adaptor might be needed:
For Windows devices, just use the long C-A cable. The C male connects to the
Hiru and the A male connects to the device.
For iPad PRO, the A-C adaptor is needed. Connect the adaptor to the iPad Pro,
and the long cable to the Hiru.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
4
Assembly Options
The IRISBOND Hiru system is designed to be fully adaptable for use with
laptops, Desktop PCs, and tablets:
Laptop Under the laptop or PC, fix the Hiru onto the holder with the provided
screws.
Click here to watch Set Up video for IRISBOND Hiru.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
5
Assembly Options
Desktop Computer / Monitor
Place the holder on a screen with the provided magnets and screw the Hiru to
the holder.
Click here to watch Set Up video for IRISBOND Hiru.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
6
Assembly Options
Tablets
1. Attached to a tablet: Rehadapt’s GA IRISBOND Hiru bracket (#16.1239).
2. Every Oskol casing comes by default with the Rehadapt’s GA Universal adapter (#16.1224) mounted.
Click here to watch Set Up video for IRISBOND Hiru.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
7
How to mount Oskol
Oskol has a space dedicated for a Surface Pro tablet and another for Hiru. To
mount the tablet in the Oskol follow these steps:
1 Remove the mounting plate and 3 screws. The screws and plate are included in
the box.
2 Separate the top and bottom pieces of the casing. Push up on each side
joint, until the top piece slides up.
3 Place the tablet in the bottom piece of the casing. The bottom corners of
the tablet should sit tightly in the casing.
4 Place the top piece over the the tablet. Slide the top piece down until it
is in place. The side joints and middle piece should fit together.
5 Place the screws in the back of the mounting plate. Use an allen wrench to
tighten.
6 Place the Hiru in the slot below and Connect the cable.
2 4 6
5 1 3
3 6
2
4 6
6
See it Possible
Click here to watch How to insert and remove a tablet and Hiru from Oskol.
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
8
Use with different Operating Systems: Overview
Hiru eye tracker can be used with both: Windows and iOS (iPad Pro). The same
eye tracker works with both operating systems.
Keep in mind
When using third party apps, the following Windows message may appear:
If this is the case, please allow both private and public networks.
Do this when installing Systray by clicking both check boxes.
To change these settings after installing, enter “Windows Defender Firewall
and select “allow an app of feature through Windows Defender Firewall”, and
enable the checkboxes accordingly.
Windows Overview EasyClick: Our computer access software. EasyClick is now
compatible with Duo and Hiru in the same app. Download this new version of
EasyClick here and a course of how to use it here.
Grid 3: From version 61 on, Grid 3 is integrated with Hiru. Select “Irisbond”
from the available eye gaze cameras.
Mind Express 5: Hiru is integrated with MindExpress 5. Select “Irisbond” from
the available eye gaze cameras. Microsoft HID: It is possible to use Windows
Eye Control with Hiru using HiruSystray app. For more information, please read
the following document.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
9
How to update Hiru in Windows
Hiru has continuous updates and new versions of firmware are released
regularly. Update Hiru in Windows using our Systray app.
Download the latest version of Systray app (below).
Updating Hiru: Step by step Install Systray from this link:
https://downloads.irisbond.com/systray
Video tutorial Update your Hiru in Windows.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
10
How to update Hiru in Windows
The Systray icon will open in the Windows Toolbar (see image below).
If the Hiru is connected to the PC, the Systray will periodically check if
there is a firmware update available. It is also possible to check for the
updates by clicking in Check Updates.
Keep in mind
IRISBOND’s Systray App should always be installed.
If an update is available, a notification will show up, please, DO NOT
disconnect the Hiru during this process.
If no notification is shown, please check that your device that the Focus
Assistant is OFF and Notifications for Systray are ON.
Ensure the focus assistant is turned off, and notifications for Systray are turned on in Windows Settings in Notifications and Actions and be sure your WiFi is connected.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
11
To ease the access of the update with eyegaze, set the notifications to appear
for more time.
Go to: Settings > Ease of Access > Display. Set Notifications to show for 5
minutes.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
12
How to update Hiru in Windows
These are the notifications that you will receive once the process is started:
See it Possible
Updating…
Updated, do not remove the Hiru. Now, the Hiru is ready to be used!
Click here to check our Youtube channel and find out more about Hiru!
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
CE & MDR | Technical Specifications
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
Compliance Information: CE and MDR
DECLARATION OF CONFORMITY
The device model has been designed and manufactured in conformity with the
Directive. San Sebastián, a 30th of April 2021
Eduardo Jauregui / Technical Director
MANUFACTURER
APPLICABLE DIRECTIVE HARMONIZED STANDARDS PRODUCT REFERENCE TEST CERTIFICATES
IRISBOND CROWDBONDING, SL VAT: ES-B75091058 ADDRESS:
AVENIDA DE TOLOSA, 75 – 2º San Sebastián CP: 20018 Guipúzcoa, País Vasco
COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993 concerning medical devices
EN 55032 (2015) / AC (2016) / A11 (2020) EN 55035 (2017): UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6 (2016)
Sistema de control del ordenador con la mirada HIRU/ Eye tracking system HIRU
IRISBOND HIRU
65321IEM.001 65321REM.001 65321REM.002 2251989-PHO-21-018A
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
Declaration of conformity (MDR)
We, Irisbond Crowdbonding Ltd, declare that the product listed below has been
designed and manufactured in conformity with the Directive (UE) 2017/745:
MANUFACTURER
IRISBOND CROWDBONDING, SL ES-B75091058 AVENIDA DE TOLOSA, 75 – 2º San Sebastián, 20018 Guipúzcoa, Spain +34 9434 96 622 http://www.irisbond.com
REFERENCE
IRISBOND HIRU
PRODUCT
Eye tracking system HIRU
The aim of this declaration is a Class I Medical Device and is in conformity with the following harmonised legislation:
APPLICABLE DIRECTIVE
· Directive (UE) 2017/745 concerning medical devices, MDR. · EMC Directive, 2004/108/EC. · RoHS Directive, 2011/65/EU. · FCC Rules and Regulations.
The following harmonized standards and technical specifications have been applied:
HARMONIZED LEGISLATION
EN 55032 (2015) / AC (2016) / A11 (2020) EN 55035 (2017) UNE-EN 62471-1:2009 FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6 (2016)
TEST CERTIFICATES
65321IEM.001
65321REM.001 65321REM.002 2251989-PHO-21-018A
This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
Declaration of conformity (MDR)
We, Irisbond Crowdbonding Ltd, declare that the product listed below has been
designed and manufactured in conformity with the Directive (UE) 2017/745:
MANUFACTURER REFERENCE PRODUCT
IRISBOND CROWDBONDING, SL ES-B75091058 AVENIDA DE TOLOSA, 75 – 2º San
Sebastián, 20018 Guipúzcoa, Spain +34 9434 96 622 http://www.irisbond.com
OSKOL WINDOWS
This product is composed by the following elements: · Medical device; Eye
tracking system HIRU. · Case to bundle the Irisbond HIRU eye tracker and the
Surface Pro tablet (TPU material has PASSED skin sensitization
and cytotoxicity tests in accordance with ISO 10993-5 and 10993-10).
The aim of this declaration is a Class I Medical Device and is in conformity with the following directives:
APPLICABLE DIRECTIVE
REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 on medical devices, MRD, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directive 90/385/EEC.
The following harmonized standards and technical specifications have been applied:
HARMONIZED LEGISLATION TEST CERTIFICATES
HIRU: EN 55032: 2015 / AC: 2016 / A11: 2020 EN 55035: 2017 UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6: 2016 OSKOL
Windows: ISO 10993-5 ISO 10993-10
65321IEM.001
65321REM.001 65321REM.002 2251989-PHO-21-018A
This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: Windows
Declaration of conformity (MDR)
We, Irisbond Crowdbonding Ltd, declare that the product listed below has been
designed and manufactured in conformity with the Directive (UE) 2017/745:
MANUFACTURER REFERENCE PRODUCT
IRISBOND CROWDBONDING, SL ES-B75091058 AVENIDA DE TOLOSA, 75 – 2º San
Sebastián, 20018 Guipúzcoa, Spain +34 9434 96 622 http://www.irisbond.com
OSKOL iPad
This product is composed by the following elements: · Eye tracking system
HIRU, medical device class I. · Case to bundle the Irisbond HIRU eye tracker
and the iPad Pro tablet (TPU material has PASSED skin sensitization
and cytotoxicity tests in accordance with ISO 10993-5 and 10993-10)
The aim of this declaration is a Class I Medical Device and is in conformity with the following harmonised legislation:
APPLICABLE DIRECTIVE
REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 concerning medical devices, MDR, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directive 90/385/EEC.
The following harmonized and/or unharmonized standards and technical specifications have been applied:
HARMONIZED LEGISLATION TEST CERTIFICATES
HIRU: EN 55032: 2015 / AC: 2016 / A11: 2020 EN 55035: 2017 UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6: 2016 OSKOL
iPad: ISO 10993-5 ISO 10993-10
65321IEM.001
65321REM.001 65321REM.002 2251989-PHO-21-018A
This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO.
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: iOS
Technical Specifications
Optimum screen size Recommended working distance Calibration Selection mode
Headbox Eye tracking Accuracy Sampling rate (Frequency) Mounting Operating
system Eye Tracking processing Windows minimum system requirements (laptop,
PC, tablet, hub)
Windows recommended system requirements iPadOS minimum system requirements
(laptop, PC, tablet, hub)
10-20″
37-75 cm.
5, 9, 16 points. 1 point fine-tuning
Dwell, Blink, Switch
20 x 18 cm. at 50 cm.
Monocular and binocular
0.4º
30-60 Hz
Holder, magnets, or specific adaptor for consumer device
Microsoft Windows 10 Pro. Apple iPadOS 17.5. Others: Please get in touch with
us
Hiru device-powered proprietary on-chip eye-tracking technology
Eye-tracking processing is done at Hiru itself. System requirements related to
the computer used with Hiru:
USB3.0-Ctypeconnection 1,33GHzCPU 8GBRAM Storage:128GB
IntelGraphics,Nvidia,andotherswithOpenGL2.0 WindowsSurfacePro7
HavethelatestversionoftheHiruappandfirmware.
System requirements related to the tablet used with Hiru: iPadPro12,9″(6thgen)
8GBRAM Storage:128GB For IPadOS operation MFi certified hub suchas Satechi.
Same as minimum and iPadOS 17.5
See it Possible
www.irisbond.com
User manual IRISBOND Quick Start Guide: iOS
Technical Specifications
requirements Weight Dimensions Eye tracking technology USB connector
Have the latest version of the Hiru app and firmware. 115g 259 x 25 x 28 mm Dark pupil and proprietary algorithms USB-C Cable insertion and removal should be handled with care.
See it Possible
www.irisbond.com
See it Possible
Avenida de Tolosa, 75. Floor 2 Donostia – San Sebastián. 20018 Gipuzkoa Spain
+34 943 49 66 22
www.irisbond.com
info@irisbond.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>