Hiru
The first multi-platform eye tracker in the world
User Manual | Quick Start Guide: Windows
User Manual IRISBOND Hiru Eye Tracking System
IRISBOND CROWDBONDING, S.L. All rights reserved.
This document, including all supporting materials, is proprietary to IRISBOND
CROWDBONDING, S.L.
As this document may contain information that is confidential, proprietary, or
otherwise legally protected, it must not be further copied, distributed, or
displayed without the express written permission of IRISBOND
CROWDBONDING, S.L.
Products that are referred to in this document may be either trademarks and/or
registered trademarks of the respective owners. The publisher and the author
make no claim to these trademarks.
Contact Information
IRISBOND CROWDBONDING, S.L
Tolosa Avenue 75, 2nd floor
20018 Donostia-San Sebastián, Gipuzkoa, Spain
+34 943 496 622
Hiru First Steps Overview
Install Systray
This program includes the Drivers and updates needed for Hiru.
Download and install eye gaze communication software
(examples: Easy click, Grid 3).
Connect Hiru
Use the provided cables.
Calibrate in your Eye Gaze Software!
Calibrating lets the Hiru adapt to your eyes so you have the best experience.
If you want to use the eye tracker with a larger screen, you can do so by changing the position of the camera and placing it further away from the screen.
Compatibility
Minimum requirements | Intel Graphics |
---|---|
CPU 1.33GHz RAM 2GB Hard Disk 3GB + HDD USB 3.0 | Nvidia and others with OpenGL |
2.0
Multiplatform
Hiru eye tracker can be used both with Windows and iOS (iPad).
The same eye tracker works with both operating systems.
We recommend iPad Pro / Surface Windows 10
iPadOS | Windows |
---|---|
iPads with a USB-C port. 15.2 and later | Windows 7-11 |
Positioning
Optimum working distance | Optimum screen size |
---|---|
55 cm. | 10” – 20” inches |
USB Connection and mounting
Depending on the device that you may be using, an adaptor might be needed:
For Windows devices, just use the long C-A cable. The C male connects to
the Hiru and the A male connects to the device.
For iPad PRO, the A-C adaptor is needed. Connect the adaptor to the iPad
Pro, and the long cable to the Hiru.
Assembly Options
The IRISBOND Hiru system is designed to be fully adaptable for use with
laptops, Desktop PCs, and tablets:
Laptop
Under the laptop or PC, fix the Hiru onto the holder with the provided
screws.
Desktop Computer / Monitor
Place the holder on a screen with the provided magnets and screw the Hiru to
the holder.
Click here to watch the Set-Up video for IRISBOND Hiru.
Tablets
-
Attached to a tablet:
Rehadapt’s GA IRISBOND Hiru bracket (#16.1239). -
Every Oskol casing comes by default with the Rehadapt’s GA Universal adapter (#16.1224) mounted.
How to mount Oskol
Oskol has a space dedicated to a tablet and another for Hiru. To mount the tablet or iPad in the Oskol follow these steps:
‘Click here to watch How to insert and remove a tablet and Hiru from Oskol.
- Separate the flexible tabs and the front casing on the top of the Oskol.
- Insert the device straight down into the slot, with the tabs behind the device.
- Once the tablet is in place, fold the tabs over the top of the device.
- Place the Hiru in the bottom slot.
- Connect the Hiru to the iPad or tablet using the USB cables, and in the case of the iPad, the adapter, or hub provided. If you’re using one, place the Hub between the back of the iPad and the section on the back of Oskol.
Keep in mind
When using the third-party apps, the following
Windows message may appear:
If this is the case, please allow both private and public networks.
- Do this when installing Systray by clicking both checkboxes.
- To change these settings after installing, enter “Windows Defender Firewall and select “Allow an app or feature through Windows Defender Firewall”, and enable the checkboxes accordingly.
Use with different Operating Systems: Overview
Hiru eye tracker can be used with both: Windows and iOS (iPad Pro). The same eye tracker works with both operating systems.
Windows Overview
EasyClick: Our computer access software. EasyClick is now compatible with
Duo and Hiru in the same app. Download this new version of EasyClick here and
a course on how to use it here.
Grid 3: From version 61 on, Grid 3 is integrated with Hiru. Select
“Irisbond” from the available eye gaze cameras.
Mind Express 5 : Hiru is integrated with MindExpress 5. Select “Irisbond”
from the available eye gaze cameras.
Microsoft HID : It is possible to use Windows Eye Control with Hiru using
the HiruSystray app. For more information, please read the following document.
How to update Hiru in Windows
Hiru has continuous updates and new versions of firmware are released
regularly. Update Hiru in Windows using our Systray app.
Download the latest version of the Systray app (below).
Updating Hiru: Step by step
Install Systray from this link:
https://downloads.irisbond.com/systray
Video tutorial Update your Hiru in Windows.
Keep in mind
- IRISBOND’s Systray App should always be installed.
- If an update is available, a notification will show up, please, DO NOT disconnect the Hiru during this process.
- If no notification is shown, please check that your device that the Focus Assistant is OFF and Notifications for Systray are ON.
The Systray icon will open in the Windows Toolbar (see image below).
If the Hiru is connected to the PC, the Systray will periodically check if
there is a firmware update available. It is also possible to check for the
updates by clicking on Check Updates.
Ensure the focus assistant is turned off, notifications for Systray are turned
on in Windows Settings in Notifications and Actions, and be sure your WiFi is
connected.
These are the notifications that you will receive once the process is started:
Updating…
Updated, do not remove the Hiru.
Now, the Hiru is ready to be used!
Click here to check our Youtube channel and find out more about Hiru!
CE & MDR | Technical Specifications
Compliance Information: CE and MDR
Compliance Information: CE and MDR
MANUFACTURER| IRISBOND CROWDBONDING, SL VAT: ES-B75091058
ADDRESS:
AVENIDA DE TOLOSA, 75 – 2º
---|---
APPLICABLE DIRECTIVE| COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993 concerning
medical devices
HARMONIZED STANDARDS| EN 55032 (2015) / AC (2016) / A11 (2020) EN 55035
(2017):
UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition)
ICES-003 Issue 6 (2016)
PRODUCT| Sistema de control del ordenador con la mirada HIRU/ Eye tracking
system HIRU
REFERENCE| IRISBOND HIRU
TEST CERTIFICATES| 65321IEM.001
65321REM.001
65321REM.002
2251989-PHO-21-018A
The device model has been designed and manufactured in conformity with the Directive.
Eduardo Jauregui / Technical Director
Declaration of conformity (MDR)
We, Irisbond Crowdbonding Ltd, declare that the product listed below has been
designed and manufactured in conformity with the Directive (UE) 2017/745:
MANUFACTURER| IRISBOND CROWDBONDING, SL
ES-B75091058
AVENIDA DE TOLOSA, 75 – 2º
+34 9434 96 622
http://www.irisbond.com
---|---
REFERENCE| IRISBOND HIRU
PRODUCT| Eye-tracking system HIRU
The aim of this declaration is a Class I Medical Device and is in conformity with the following harmonized legislation:
APPLICABLE DIRECTIVE| • Directive (UE) 2017/745 concerning medical devices,
MDR.
• EMC Directive, 2004/108/EC.
• RoHS Directive, 2011/65/EU.
• FCC Rules and Regulations.
---|---
The following harmonized standards and technical specifications have been applied:
HARMONIZED LEGISLATION| EN 55032 (2015) / AC (2016) / A11 (2020)
EN 55035 (2017)
UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition)
ICES-003 Issue 6 (2016)
---|---
TEST CERTIFICATES| 65321IEM.001
65321REM.001
65321REM.002
2251989-PHO-21-018A
This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO.
Declaration of conformity (MDR)
We, Irisbond Crowdbonding Ltd, declare that the product listed below has been
designed and manufactured in conformity with the Directive (UE) 2017/745:
MANUFACTURER| IRISBOND CROWDBONDING, SL
ES-B75091058
AVENIDA DE TOLOSA, 75 – 2
+34 9434 96 622
http://www.irisbond.com
---|---
REFERENCE| OSKOL WINDOWS
PRODUCT| This product is composed of the following elements:
• Medical device; Eye-tracking system HIRU.
• Case to bundle the Irisbond HIRU eye tracker and the Surface Pro tablet
(TPU material has PASSED skin sensitization and cytotoxicity tests in
accordance with ISO 10993-5 and 10993-10).
The aim of this declaration is a Class I Medical Device and is in conformity with the following directives:
APPLICABLE DIRECTIVE| REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND
OF THE COUNCIL of 5 April 2017 on medical devices, MRD, amending Directive
2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and
repealing Council Directive 90/385/EEC.
---|---
The following harmonized standards and technical specifications have been applied:
HARMONIZED LEGISLATION| HIRU:
EN 55032: 2015 / AC: 2016 / A11: 2020
EN 55035: 2017
UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition)
ICES-003 Issue 6: 2016
OSKOL Windows:
ISO 10993-5
ISO 10993-10
---|---
TEST CERTIFICATES| 65321IEM.001
65321REM.001
65321REM.002
2251989-PHO-21-018A
This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO.
Declaration of conformity (MDR)
We, Irisbond Crowdbonding Ltd, declare that the product listed below has been
designed and manufactured in conformity with the Directive (UE) 2017/745:
MANUFACTURER| IRISBOND CROWDBONDING, SL
ES-B75091058
AVENIDA DE TOLOSA, 75 – 2º
San Sebastián, 20018 Guipúzcoa, Spain
+34 9434 96 622
http://www.irisbond.com
---|---
REFERENCE| OSKOL iPad
PRODUCT
| This product is composed of the following elements:
• Eye tracking system HIRU, medical device class I.
• Case to bundle the Irisbond HIRU eye tracker and the iPad Pro tablet (TPU
material has PASSED skin sensitization and cytotoxicity tests in accordance
with ISO 10993-5 and 10993-10)
The aim of this declaration is a Class I Medical Device and is in conformity with the following harmonized legislation:
APPLICABLE DIRECTIVE| REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND
OF THE COUNCIL of 5 April 2017 concerning medical devices, MDR, amending
Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No
1223/2009 and repealing Council Directive 90/385/EEC.
---|---
The following harmonized and/or unharmonized standards and technical specifications have been applied:
HARMONIZED LEGISLATION
| HIRU:
EN 55032: 2015 / AC: 2016 / A11: 2020
EN 55035: 2017
UNE-EN 62471-1:2009
FCC CFR 47, Part 15, Subpart B (10-1-15 Edition)
ICES-003 Issue 6: 2016
OSKOL iPad:
ISO 10993-5
ISO 10993-10
---|---
TEST CERTIFICATES| 65321IEM.001
65321REM.001
65321REM.002
2251989-PHO-21-018A
This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO.
Technical Specifications
Optimum screen size | 10-20” |
---|---|
Recommended working distance | 35-80 cm. |
Calibration | 0, 1, 5, 9, 16 points |
Selection mode | Dwell, Blink, Switch |
Headbox | 20 x 18 cm. at 50 cm. |
Eye-tracking | Monocular and binocular |
Accuracy | 0.4º |
Sampling rate (Frequency) | 60 Hz. |
Mounting | Holder, magnets, or specific adaptor for a consumer device |
Operating system | Windows: 7-10 iPadOS: 13 or above Others: Please get in |
touch with us
Eye Tracking processing| Hiru on-chip eye-tracking technology
Minimum system requirements (laptop, PC, tablet)| Eye-tracking processing is
done at HIRU itself. System requirements related to the applications used with
HIRU. Typically:
• USB 3.0 -C
• 1,33 GHz CPU
• 2 GB RAM
• 3GB + HDD Hard Disk
• Intel Graphics, Nvidia, and others with OpenGL 2.0
• iOS: iPad Pro
Weight| 115 g.
Dimensions| 259 x 25 x 28 mm.
Eye-tracking technology| Dark pupil
USB connector| USB-C
See it Possible
Avenida de Tolosa, 75. Floor 2
Donostia San-Sebastián. 20018 Gipuzkoa
Spain +34 943 49 66 22
www.irisbond.com
info@irisbond.com
References
Read User Manual Online (PDF format)