What’s in the Box
Downlight w/ Nightlight
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off circuit breaker before installing this fixture.
- This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended.
- Abide by related regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, relocate, or remove wiring during installation.
- Do not make or alter any open holes in wiring enclosure or electrical components during installation.
- Check for shipping damage before insatalling. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference.
- Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- Use safety precautions and abide by regional and local laws or regulations.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with occupancy sensors.
- This product is not compatible with timing devices.
WARNING:
Cancer & Reproductive Harm- www.P65Warnings.ca.gov
This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
-
Step 1
Use template to cut hole. -
Step 2
Connect supply & junction wires. -
Step 3
Attach fixture to junction box. -
Step 4
Insert fixture into ceiling.
Installation Guide
-
STEP 1
- a. Turn off circuit breaker before installation.
- b. Cut out 6.33” housing size on Installation Template (C), then tape onto ceiling in desired location.
- c. Cut ceiling hole using Installation Template (C) as a guide.
-
STEP 2
- a. Open junction box (B) and remove appropriate knockout.
-
STEP 3
a. Thread cable connector through J-Box knockout, secure wires with screws, then connect cable connector on opposite side.
b. Connect supply wires with junction wires using wire nuts (C): – Black to Black (Live) -White to White (Neutral) – Bare Copper to Bare Copper (Ground)
c. Tuck connected wires inside junction box and close the cover. -
STEP 4
Selectable CCT Models:
Slide CCT switch to select desired color temperature.
Insert junction box through ceiling hole.
New Construction: Secure to studs, joists, or similar fixed structural units.
Remodel: Does not require to secure to studs, joists, or similar fixed units. -
STEP 5
- a. Attach fixture to junction box using connector (1).
- b. Tighten connector by hand (2).
-
STEP 6
a. To toggle between downlight and nightlight mode, toggle wall switch within 2 seconds.
Note: lf using multiple lights and they are not synced, turn off lights for more than 5 seconds. Each light will go into downlight mode and become synchronized.
Product Details
Recommended Dimmers
Brand | Model |
---|---|
LUTRON | P-PKG1WB-WH |
LUTRON | MACL-153M-WH |
LUTRON | PD-6WCL-WH |
LUTRON | AYCL-153P-WH |
LUTRON | DVCL-153P-WH |
LEVITON | D26HD-2RW |
KASA SMART | HS220 |
KASA SMART | HS220P3 |
Scan for the full compatible dimmer list!
Specifications
Voltage | 120V | Average Lifetime | 50,000 Hours |
---|---|---|---|
Wattage | 15W | Lumens | 1500LM |
Wattage Equivalency | 150W | Moisture Rating | Damp Rated |
Beam Angle | 90° | CRI | 90+ |
Weight | 0.87 lbs | Usage | Indoor |
Housing Material | Plastic + Metal | IC Rated | Yes |
Dimmable | Yes | Warranty | 7 Years |
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy- to-follow solutions for any problem.
If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.
Light Distribution Angle
Not a lighting nerd?
No worries, you can skip this page
- Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles:
- A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.
Downlight Mode
AVERAGE BEAM ANGLE (50%): 107.8 DEG
UNIT:cd Luminous Intensity Distribution 1
Nightlight Mode
AVERAGE BEAM ANGLE (50%): 98.3 DEG
UNIT:cd Luminous Intensity Distribution 1
An asymmetric lighting distribution angle, also known as beam angle, creates a
pattern that focuses light in a specific direction. This type of lighting is
ideal for task lighting as it reduces glare and light spill in other areas.
Common applications include task lighting in spaces such as landscape
settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be
affected by other factors such as the reflector design of the light source,
the type of lens used, and the distance between the light source and the
surface being illuminated.