- Product Specifications
- Product Usage Instructions
- Cooling Capacity Guidelines:
- Installation Requirements:
- Maintenance:
- Q: What refrigerant does this air conditioner use?
- Q: How often should I clean the filters?
- Q: Can this air conditioner be used for heating as well?
GLXS3B Energy Efficient Classic Split System Air Conditioner
“`html
Product Specifications
Model: GLXS3BN
Cooling Capacity:
- 18,000 BTU/h
- 24,000 BTU/h
- 30,000 BTU/h
- 36,000 BTU/h
- 42,000 BTU/h
- 48,000 BTU/h
- 60,000 BTU/h
Decibels (dBA) Compressor:
- 73.0 dB
- 74.0 dB
- 69.0 dB
- 71.0 dB
RLA (Rated Load Amps):
- 8.2 A
- 11.2 A
- 13.4 A
- 14.4 A
- 19.4 A
- 23.9 A
LRA (Locked Rotor Amps):
- 41.2 A
- 52.5 A
- 83.3 A
- 112.2 A
- 127.7 A
- 148.0 A
Product Usage Instructions
Cooling Capacity Guidelines:
This air conditioner is suitable for spaces up to the specified
square footage based on the cooling capacity provided in the
specifications.
Installation Requirements:
Ensure proper electrical supply with voltage and phase as per
specifications. Refer to wiring diagrams for correct
installation.
Maintenance:
Regularly clean filters and ensure proper airflow for optimal
performance. Schedule professional maintenance at least once a
year.
FAQs (Frequently Asked Questions)
Q: What refrigerant does this air conditioner use?
A: The air conditioner uses R-32 refrigerant.
Q: How often should I clean the filters?
A: Filters should be cleaned at least once a month or more
frequently in dusty environments.
Q: Can this air conditioner be used for heating as well?
A: This model is a cooling-only air conditioner and does not
provide heating functionality.
“`
GLXS3B
Energy-Efficient Classic R-32 Split System Air Conditioner
Up to 15 SEER2 1½ To 5 Tons
Contents Nomenclature…………………………………. 2 Product Specifications……………………… 3
Expanded Cooling Data ……………………. 4 Performance Data …………………………. 18 Dimensions
…………………………………… 20 Wiring Diagrams …………………………… 21 Accessories …………………………………… 23
Standard Features
· Energy-efficient compressor · Fully charged for 15′ of tubing length ·
Copper tube/ enhanced aluminum
fin coil-5mm diameter · Factory-installed filter drier · Sweat connection
service valves
with easy access to gauge ports · Enclosed contactor · High-pressure switch ·
Ground lug connection · Capacitors with extended life · AHRI Certified · ETL
Listed
Cabinet Features
· Removable grille-style top design compliant with UL 60335-2-40
· Venturi for increased velocity of airflow
· Attractive Architectural Gray powder-paint finish with 500-hour salt-spray
approval
· Wire fan discharge grille
· Steel louver coil guard
· Top and side maintenance access
· Single-panel access to controls with space provided for field-installed
accessories
· When properly anchored, meets the 2023 Florida Building Code unit integrity
requirements for hurricane-type winds (Anchor bracket kits available.)
SS-GLXS4B-R32
- Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. TThe duration of warranty coverage in Texas and Florida differs in some cases.
www.goodmanmfg.com
07/24
Nomenclature
G L X S 3 B N 36 1
0
A
A
1 2 3 4 5 6 7 8,9 10 11 12 13
Brand G – Goodman® Brand
Type L R-32 Splits System
Minor Rev A
Major Revision A
Variation
Outdoor Type X Condenser Z Heat Pump
Compressor Type S Single-Stage T Two-Stage
Efficiency (SEER2) Nominal
13.4 – 13.7 = 3 13.8 – 14.5 = 4 14.6 – 15.9 = 5
16.0-16.9 = 6 17.0-17.9 = 7 18.0-18.9 = 8 19.0+ = 9
Electrical 1 208/230 V, 1 Phase, 60 Hz
18 – 1½ Tons 24 – 2 Tons 30 – 2 Tons 36 – 3 Tons
Nominal Capacity 42 – 3½ Tons 48 – 4 Tons 60 – 5 Tons
Region
N North S Southeast & North
A All Regions
Feature/Application B – Standard
M – Multi-Family C – Communicating (Top Flow)
2
www.goodmanmfg.com
SS-GLXS3B-R32
Product Specifications
GLXS3BN 1810A*
GLXS3BN 2410A*
GLXS3BN 3010A*
GLXS3BN 3610A*
GLXS3BN 4210A*
GLXS3BN 4810A*
GLXS3BN 6010A*
Cooling Capacity
Nominal Cooling (BTU/h)
18,000
24,000
30,000
36,000
42,000
48,000
60,000
Decibels (dBA) Compressor
73.0
74.0
74.0
69.0
73.0
71.0
74.0
RLA
8.2
8.2
11.2
13.4
14.4
19.4
23.9
LRA
41.2
41.2
52.5
83.3
112.2
127.7
148.0
Stage Type Condenser Fan Motor
Single Rotary
Single Rotary
Single Rotary
Single Scroll
Single Scroll
Single Scroll
Single Scroll
Motor Type Horsepower (RPM)
PSC
PSC
PSC
PSC
PSC
PSC
PSC
1/8
1/8
1/8
1/8
1/4
1/4
1/4
FLA Refrigeration System
0.70
0.70
0.70
0.70
1.4
1.4
1.3
Refrigerant Line Size1
Liquid Line Size (“O.D.)
”
”
”
”
”
”
”
Suction Line Size (“O.D.)
¾”
¾”
¾”
”
1″
1″
1″
Refrigerant Connection Size
Liquid Valve Size (“O.D.)
”
”
”
”
”
”
”
Suction Valve Size (“O.D.) 2
¾”
¾”
¾”
”
”
”
”
Valve Connection Type Refrigerant Charge 3 Electrical Data
Sweat 53
Sweat 53
Sweat 60
Sweat 60
Sweat 74
Sweat 84
Sweat 91
Voltage-Phase
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
Minimum Circuit Ampacity 4 Max. Overcurrent Protection 5 Min / Max Volts
10.9 15.0 197/253
10.9 15.0 197/253
14.7 25.0 197/253
17.5 30.0 197/253
19.4 30.0 197/253
25.6 40.0 197/253
31.1 50.0 197/253
Electrical Conduit Size
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
Equipment Weight (lbs) Ship Weight (lbs)
114
114
134
136
180
188
229
129
129
149
151
195
203
244
1 Line sizes denoted for 25′ line sets, tested and rated in accordance with
AHRI Standard 210/240. For other line set lengths or sizes, refer to the
Installation Instructions and/or the Long Line Set Applications guide.
2 Any suction line adapter will need to be supplied by the field.
3 Unit is factory charged with refrigerant for 15′ of ” liquid line. System
charge must be adjusted per the Final Charge Adjustment procedure found in the
Installation Instructions.
4 Wire size should be determined in accordance with National Electrical Codes;
extensive wire runs will require larger wire sizes
5 Must use time-delay fuses or HACR-type circuit breakers of the same size as
noted.
Notes · Always check the S&R plate for electrical data on the unit being installed.
SS-GLXS3B-R32
www.goodmanmfg.com
3
Expanded Cooling Data — GLXS3BN1810A+ CAPTA2422A
4
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 18.3 18.5 19.1 – 18.1 18.3 18.9 – 17.6 17.9 18.4 – 16.8 17.0 17.6 – 15.8 16.0 16.6 – 14.9 15.1 15.7 –
S/T 0.53 0.46 0.34 – 0.54 0.47 0.34 – 0.56 0.49 0.37 – 0.58 0.51 0.38 – 0.60 0.53 0.40 – 0.64 0.57 0.45 –
525 T 23 21 17
–
23 21 17
–
24 22 18
–
23 21 17
–
23 21 17
–
24 22 18
–
kW 1.19 1.19 1.18 – 1.32 1.31 1.31 – 1.46 1.46 1.46 – 1.61 1.61 1.61 – 1.79 1.79 1.78 – 1.99 1.99 1.99 –
Amps 4.2 4.2 4.2 – 4.8 4.8 4.8 – 5.4 5.4 5.4 – 6.1 6.1 6.1 – 6.9 6.9 6.9 – 7.9 7.9 7.8 –
MBh 18.6 18.8 19.4 – 18.4 18.6 19.2 – 17.9 18.2 18.7 – 17.1 17.3 17.9 – 16.1 16.3 16.9 – 15.2 15.4 16.0 –
S/T 0.61 0.54 0.41 – 0.61 0.54 0.42 – 0.63 0.56 0.44 – 0.65 0.58 0.46 – 0.67 0.60 0.48 – 0.72 0.65 0.53 –
70 625 T 22 20 16
–
22 20 16
–
22 20 16
–
22 20 16
–
21 19 15
–
23 21 17
–
kW 1.20 1.20 1.19 – 1.32 1.32 1.32 – 1.47 1.47 1.46 – 1.62 1.62 1.62 – 1.80 1.79 1.79 – 2.00 2.00 1.99 –
Amps 4.2 4.2 4.2 – 4.8 4.8 4.8 – 5.5 5.5 5.5 – 6.2 6.2 6.2 – 7.0 7.0 7.0 – 7.9 7.9 7.9 –
MBh 18.7 19.0 19.5 – 18.6 18.8 19.4 – 18.1 18.3 18.9 – 17.3 17.5 18.1 – 16.3 16.5 17.1 – 15.3 15.6 16.1 –
S/T 0.63 0.56 0.44 – 0.63 0.56 0.44 – 0.66 0.59 0.46 – 0.67 0.60 0.48 – 0.69 0.62 0.50 – 0.74 0.67 0.55 –
675 T 21 19 15
–
21 19 15
–
21 19 15
–
21 19 15
–
21 19 15
–
22 20 16
–
kW 1.20 1.20 1.20 – 1.33 1.33 1.32 – 1.47 1.47 1.47 – 1.63 1.62 1.62 – 1.80 1.80 1.80 – 2.00 2.00 2.00 –
Amps 4.2 4.2 4.2 – 4.8 4.8 4.8 – 5.5 5.5 5.5 – 6.2 6.2 6.2 – 7.0 7.0 7.0 – 7.9 7.9 7.9 –
www.goodmanmfg.com
MBh 18.3 18.5 19.1 19.9 18.1 18.4 18.9 19.7 17.6 17.9 18.4 19.3 16.8 17.1 17.6 18.4 15.8 16.1 16.6 17.4 14.9 15.1 15.7 16.5
S/T 0.65 0.58 0.46 0.3 0.65 0.58 0.46 0.3 0.68 0.61 0.48 0.4 0.69 0.62 0.50 0.4 0.71 0.64 0.52 0.4 1.00 0.69 0.57 0.4
525 T 28 26 22 18 28 26 22 18 28 26 22 18 28 26 22 18 28 26 22 18 29 27 23 19
kW 1.19 1.19 1.18 1.2 1.31 1.31 1.31 1.3 1.46 1.46 1.45 1.5 1.61 1.61 1.61 1.6 1.79 1.78 1.78 1.8 1.99 1.99 1.99 2.0
Amps 4.2 4.2 4.2 4.2 4.8 4.8 4.8 4.8 5.4 5.4 5.4 5.5 6.1 6.1 6.1 6.2 6.9 6.9 6.9 7.0 7.9 7.9 7.8 7.9
MBh 18.6 18.8 19.4 20.2 18.4 18.7 19.2 20.0 17.9 18.2 18.7 19.6 17.1 17.4 17.9 18.7 16.1 16.4 16.9 17.7 15.2 15.4 16.0 16.8
S/T 0.72 0.65 0.53 0.4 0.73 0.66 0.54 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.4 1.00 0.72 0.60 0.5 1.00 0.77 0.64 0.5
75 625 T 26 24 20 16 26 24 20 16 27 25 21 16 26 24 20 16 26 24 20 16 27 25 21 17
kW 1.20 1.19 1.19 1.20 1.32 1.32 1.32 1.33 1.47 1.47 1.46 1.47 1.62 1.62 1.62 1.63 1.79 1.79 1.79 1.80 2.00 2.00 1.99 2.00
Amps 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.8 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9
MBh 18.7 19.0 19.5 20.4 18.6 18.8 19.4 20.2 18.1 18.4 18.9 19.7 17.3 17.5 18.1 18.9 16.3 16.5 17.1 17.9 15.4 15.6 16.2 17.0
S/T 0.74 0.68 0.55 0.4 0.75 0.68 0.56 0.4 0.77 0.70 0.58 0.5 0.79 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.79 0.67 0.5
675 T 26 24 20 16 26 24 20 15 26 24 20 16 26 24 20 15 25 23 19 15 27 25 21 16
kW 1.20 1.20 1.20 1.2 1.33 1.33 1.32 1.3 1.47 1.47 1.47 1.5 1.62 1.62 1.62 1.6 1.80 1.80 1.79 1.8 2.00 2.00 2.00 2.0
Amps 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 18.4 18.6 19.2 20.0 18.2 18.5 19.0 19.8 17.7 18.0 18.5 19.4 16.9 17.2 17.7 18.5 15.9 16.1 16.7 17.5 15.0 15.2 15.8 16.6
S/T 0.76 0.69 0.57 0.4 0.77 0.70 0.58 0.4 0.79 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.76 0.64 0.5 1.00 0.81 0.68 0.6
525 T 33 31 27 23 33 31 27 23 33 31 27 23 33 31 27 23 33 30 26 22 34 32 28 24 kW 1.19 1.19 1.18 1.2 1.32 1.31 1.31 1.3 1.46 1.46 1.46 1.5 1.61 1.61 1.61 1.6 1.79 1.79 1.78 1.8 1.99 1.99 1.99 2.0
Amps 4.2 4.2 4.2 4.2 4.8 4.8 4.8 4.8 5.4 5.4 5.4 5.5 6.1 6.1 6.1 6.2 6.9 6.9 6.9 7.0 7.9 7.9 7.8 7.9
MBh 18.7 18.9 19.5 20.3 18.5 18.8 19.3 20.1 18.0 18.3 18.8 19.7 17.2 17.5 18.0 18.8 16.2 16.4 17.0 17.8 15.3 15.5 16.1 16.9
S/T 0.84 0.77 0.64 0.5 0.84 0.77 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.88 0.76 0.6
80 625 T 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 32 30 26 22 kW 1.20 1.19 1.19 1.20 1.32 1.32 1.32 1.33 1.47 1.47 1.46 1.47 1.62 1.62 1.62 1.63 1.79 1.79 1.79 1.80 2.00 2.00 1.99 2.00
Amps 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.8 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9
MBh 18.8 19.1 19.6 20.5 18.7 18.9 19.5 20.3 18.2 18.5 19.0 19.8 17.4 17.6 18.2 19.0 16.4 16.6 17.2 18.0 15.4 15.7 16.3 17.1
S/T 0.86 0.79 0.67 0.5 0.86 0.80 0.67 0.5 1.00 0.82 0.69 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 0.90 0.78 0.6
675 T 30 28 24 20 30 28 24 20 31 29 25 20 30 28 24 20 30 28 24 20 31 29 25 21
kW 1.20 1.20 1.20 1.2 1.33 1.33 1.32 1.3 1.47 1.47 1.47 1.5 1.63 1.62 1.62 1.6 1.80 1.80 1.80 1.8 2.00 2.00 2.00 2.0
Amps 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9
Expanded Cooling Data — GLXS3BN1810A+ CAPTA2422A (cont.)
www.goodmanmfg.com
MBh 18.7 18.9 19.5 20.3 18.5 18.8 19.3 20.1 18.0 18.3 18.8 19.7 17.2 17.5 18.0 18.8 16.2 16.5 17.0 17.8 15.3 15.5 16.1 16.9
S/T 1.00 0.78 0.66 0.5 1.00 0.79 0.67 0.5 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.85 0.73 0.6 1.00 1.00 0.77 0.6
525 T 37 35 31 27 37 35 31 27 37 35 31 27 37 35 31 27 37 35 31 26 38 36 32 28
kW 1.19 1.19 1.19 1.2 1.32 1.32 1.31 1.3 1.46 1.46 1.46 1.5 1.62 1.61 1.61 1.6 1.79 1.79 1.79 1.8 1.99 1.99 1.99 2.0
Amps 4.2 4.2 4.2 4.2 4.8 4.8 4.8 4.8 5.4 5.4 5.4 5.5 6.2 6.1 6.1 6.2 6.9 6.9 6.9 7.0 7.9 7.9 7.9 7.9
MBh 19.0 19.2 19.8 20.6 18.8 19.1 19.6 20.4 18.3 18.6 19.1 20.0 17.5 17.8 18.3 19.1 16.5 16.8 17.3 18.1 15.6 15.8 16.4 17.2
S/T 1.00 0.86 0.74 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.85 0.7
85 625 T 35 33 29 25 35 33 29 25 36 34 30 25 35 33 29 25 35 33 29 25 36 34 30 26
kW 1.20 1.20 1.20 1.20 1.33 1.33 1.32 1.33 1.47 1.47 1.47 1.48 1.62 1.62 1.62 1.63 1.80 1.80 1.79 1.80 2.00 2.00 2.00 2.01
Amps 4.2 4.2 4.2 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 7.9
MBh 19.1 19.4 20.0 20.8 19.0 19.2 19.8 20.6 18.5 18.8 19.3 20.1 17.7 17.9 18.5 19.3 16.7 16.9 17.5 18.3 15.8 16.0 16.6 17.4
S/T 1.00 0.88 0.76 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7
675 T 35 33 29 24 35 32 29 24 35 33 29 25 35 32 28 24 34 32 28 24 36 34 30 25
kW 1.20 1.20 1.20 1.2 1.33 1.33 1.33 1.3 1.47 1.47 1.47 1.5 1.63 1.63 1.62 1.6 1.80 1.80 1.80 1.8 2.00 2.00 2.00 2.0
Amps 4.3 4.3 4.2 4.3 4.8 4.8 4.8 4.9 5.5 5.5 5.5 5.5 6.2 6.2 6.2 6.2 7.0 7.0 7.0 7.0 7.9 7.9 7.9 8.0
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
5
Expanded Cooling Data — GLXS3BN2410A+ CAPTA2422A
6
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 23.7 24.0 24.7 – 23.5 23.8 24.5 – 22.9 23.2 23.9 – 21.8 22.2 22.9 – 20.6 20.9 21.6 – 19.4 19.7 20.4 –
S/T 0.63 0.56 0.43 – 0.64 0.57 0.44 – 0.66 0.59 0.46 – 0.68 0.61 0.48 – 0.70 0.63 0.50 – 0.75 0.68 0.55 –
700 T 21 19 15
–
21 19 15
–
21 19 15
–
21 19 15
–
20 18 15
–
22 20 16
–
kW 1.50 1.50 1.50 – 1.67 1.67 1.67 – 1.87 1.86 1.86 – 2.07 2.07 2.07 – 2.31 2.30 2.30 – 2.58 2.58 2.57 –
Amps 5.5 5.5 5.4 – 6.2 6.2 6.2 – 7.1 7.1 7.1 – 8.1 8.1 8.1 – 9.1 9.1 9.1 – 10.4 10.4 10.4 –
MBh 24.1 24.5 25.2 – 23.9 24.3 25.0 – 23.3 23.6 24.3 – 22.3 22.6 23.3 – 21.0 21.3 22.0 – 19.8 20.1 20.8 –
S/T 0.67 0.59 0.47 – 0.67 0.60 0.47 – 0.70 0.62 0.50 – 0.71 0.64 0.51 – 0.74 0.66 0.53 – 1.00 0.71 0.58 –
70 800 T 20 18 14
–
20 17 14
–
20 18 14
–
20 17 14
–
19 17 13
–
21 18 15
–
kW 1.51 1.51 1.51 – 1.68 1.68 1.68 – 1.87 1.87 1.87 – 2.08 2.08 2.08 – 2.31 2.31 2.31 – 2.59 2.59 2.58 –
Amps 5.5 5.5 5.5 – 6.3 6.3 6.3 – 7.2 7.2 7.1 – 8.1 8.1 8.1 – 9.2 9.2 9.2 – 10.4 10.4 10.4 –
MBh 24.7 25.0 25.7 – 24.5 24.8 25.5 – 23.8 24.2 24.9 – 22.8 23.1 23.8 – 21.5 21.8 22.5 – 20.3 20.7 21.4 –
S/T 0.67 0.60 0.47 – 0.68 0.61 0.48 – 0.70 0.63 0.50 – 0.72 0.65 0.52 – 0.74 0.67 0.54 – 1.00 0.72 0.59 –
900 T 19 17 13
–
18 16 13
–
19 17 13
–
18 16 13
–
18 16 12
–
19 17 14
–
kW 1.52 1.52 1.51 – 1.69 1.69 1.69 – 1.88 1.88 1.88 – 2.09 2.09 2.09 – 2.32 2.32 2.32 – 2.59 2.59 2.59 –
Amps 5.5 5.5 5.5 – 6.3 6.3 6.3 – 7.2 7.2 7.2 – 8.1 8.1 8.1 – 9.2 9.2 9.2 – 10.5 10.5 10.4 –
www.goodmanmfg.com
MBh 23.7 24.1 24.8 25.8 23.5 23.8 24.5 25.6 22.9 23.2 23.9 25.0 21.8 22.2 22.9 23.9 20.6 20.9 21.6 22.7 19.4 19.7 20.4 21.5
S/T 0.75 0.68 0.55 0.4 0.76 0.69 0.56 0.4 0.78 0.71 0.58 0.4 0.80 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.80 0.67 0.5
700 T 25 23 19 15 25 23 19 15 25 23 20 16 25 23 19 15 25 23 19 15 26 24 20 16
kW 1.50 1.50 1.50 1.5 1.67 1.67 1.67 1.7 1.86 1.86 1.86 1.9 2.07 2.07 2.07 2.1 2.30 2.30 2.30 2.3 2.58 2.58 2.57 2.6
Amps 5.5 5.4 5.4 5.5 6.2 6.2 6.2 6.3 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.1 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.4
MBh 24.1 24.5 25.2 26.2 23.9 24.3 25.0 26.0 23.3 23.7 24.4 25.4 22.3 22.6 23.3 24.4 21.0 21.3 22.0 23.1 19.8 20.1 20.8 21.9
S/T 0.79 0.72 0.59 0.5 0.79 0.72 0.59 0.5 0.82 0.75 0.62 0.5 1.00 0.76 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.83 0.71 0.6
75 800 T 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 24 22 18 14 25 23 19 15
kW 1.51 1.51 1.50 1.52 1.68 1.68 1.68 1.69 1.87 1.87 1.87 1.88 2.08 2.08 2.08 2.09 2.31 2.31 2.31 2.32 2.59 2.58 2.58 2.59
Amps 5.5 5.5 5.5 5.5 6.3 6.3 6.3 6.3 7.2 7.2 7.1 7.2 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 10.4 10.4 10.4 10.5
MBh 24.7 25.0 25.7 26.8 24.5 24.8 25.5 26.6 23.9 24.2 24.9 26.0 22.8 23.1 23.8 24.9 21.5 21.8 22.5 23.6 20.3 20.7 21.4 22.4
S/T 0.80 0.72 0.60 0.5 0.80 0.73 0.60 0.5 0.83 0.75 0.63 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.84 0.71 0.6
900 T 23 21 17 13 23 21 17 13 23 21 17 13 23 21 17 13 23 21 17 13 24 22 18 14
kW 1.52 1.52 1.51 1.5 1.69 1.69 1.68 1.7 1.88 1.88 1.88 1.9 2.09 2.09 2.08 2.1 2.32 2.32 2.32 2.3 2.59 2.59 2.59 2.6
Amps 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 10.5 10.4 10.4 10.5
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 23.8 24.2 24.9 25.9 23.6 24.0 24.7 25.7 23.0 23.4 24.1 25.1 22.0 22.3 23.0 24.1 20.7 21.0 21.7 22.8 19.5 19.8 20.5 21.6
S/T 0.87 0.80 0.67 0.5 0.88 0.81 0.68 0.5 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.92 0.79 0.7
700 T 30 28 24 20 30 28 24 20 30 28 24 20 30 28 24 20 29 27 24 20 31 29 25 21 kW 1.50 1.50 1.50 1.5 1.67 1.67 1.67 1.7 1.87 1.86 1.86 1.9 2.07 2.07 2.07 2.1 2.31 2.30 2.30 2.3 2.58 2.58 2.57 2.6
Amps 5.5 5.5 5.4 5.5 6.2 6.2 6.2 6.3 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.1 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.4
MBh 24.3 24.6 25.3 26.4 24.1 24.4 25.1 26.2 23.4 23.8 24.5 25.5 22.4 22.7 23.4 24.5 21.1 21.4 22.1 23.2 19.9 20.3 21.0 22.0
S/T 0.91 0.84 0.71 0.6 1.00 0.84 0.71 0.6 1.00 0.87 0.74 0.6 1.00 0.88 0.76 0.6 1.00 0.90 0.78 0.6 1.00 1.00 0.82 0.7
80 800 T 29 27 23 19 28 26 23 19 29 27 23 19 28 26 23 19 28 26 22 18 29 27 24 20 kW 1.51 1.51 1.51 1.52 1.68 1.68 1.68 1.69 1.87 1.87 1.87 1.88 2.08 2.08 2.08 2.09 2.31 2.31 2.31 2.32 2.59 2.59 2.58 2.60
Amps 5.5 5.5 5.5 5.5 6.3 6.3 6.3 6.3 7.2 7.2 7.1 7.2 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 10.4 10.4 10.4 10.5
MBh 24.8 25.1 25.8 26.9 24.6 24.9 25.6 26.7 24.0 24.3 25.0 26.1 22.9 23.3 24.0 25.0 21.6 22.0 22.7 23.7 20.5 20.8 21.5 22.6
S/T 0.92 0.84 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.83 0.7
900 T 28 25 22 18 27 25 22 18 28 26 22 18 27 25 22 18 27 25 21 17 28 26 23 19
kW 1.52 1.52 1.51 1.5 1.69 1.69 1.69 1.7 1.88 1.88 1.88 1.9 2.09 2.09 2.08 2.1 2.32 2.32 2.32 2.3 2.59 2.59 2.59 2.6
Amps 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.3 10.5 10.5 10.4 10.5
Expanded Cooling Data — GLXS3BN2410A+ CAPTA2422A (cont.)
www.goodmanmfg.com
MBh 24.2 24.6 25.3 26.3 24.0 24.4 25.1 26.1 23.4 23.7 24.4 25.5 22.4 22.7 23.4 24.5 21.1 21.4 22.1 23.2 19.9 20.2 20.9 22.0
S/T 1.00 0.90 0.77 0.6 1.00 0.90 0.77 0.6 1.00 0.93 0.80 0.7 1.00 0.94 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8
700 T 34 32 28 24 34 32 28 24 34 32 28 24 34 32 28 24 33 31 28 24 35 33 29 25
kW 1.50 1.50 1.50 1.5 1.68 1.68 1.67 1.7 1.87 1.87 1.86 1.9 2.08 2.08 2.07 2.1 2.31 2.31 2.30 2.3 2.58 2.58 2.58 2.6
Amps 5.5 5.5 5.5 5.5 6.3 6.3 6.2 6.3 7.1 7.1 7.1 7.2 8.1 8.1 8.1 8.1 9.2 9.1 9.1 9.2 10.4 10.4 10.4 10.4
MBh 24.7 25.0 25.7 26.8 24.5 24.8 25.5 26.6 23.8 24.2 24.9 25.9 22.8 23.1 23.8 24.9 21.5 21.8 22.5 23.6 20.3 20.7 21.4 22.4
S/T 1.00 0.93 0.80 0.7 1.00 0.94 0.81 0.7 1.00 0.96 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.92 0.8
85 800 T 33 31 27 23 32 30 27 23 33 31 27 23 32 30 27 23 32 30 26 22 33 31 28 24
kW 1.51 1.51 1.51 1.52 1.69 1.68 1.68 1.69 1.88 1.88 1.87 1.89 2.09 2.08 2.08 2.09 2.32 2.32 2.31 2.33 2.59 2.59 2.59 2.60
Amps 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.3 7.2 7.2 7.2 7.2 8.1 8.1 8.1 8.2 9.2 9.2 9.2 9.2 10.4 10.4 10.4 10.5
MBh 25.2 25.5 26.2 27.3 25.0 25.3 26.0 27.1 24.4 24.7 25.4 26.5 23.3 23.6 24.3 25.4 22.0 22.4 23.1 24.1 20.9 21.2 21.9 23.0
S/T 1.00 0.94 0.81 0.7 1.00 0.94 0.82 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.93 0.8
900 T 32 29 26 22 31 29 26 22 32 30 26 22 31 29 26 22 31 29 25 21 32 30 27 23
kW 1.52 1.52 1.52 1.5 1.69 1.69 1.69 1.7 1.88 1.88 1.88 1.9 2.09 2.09 2.09 2.1 2.32 2.32 2.32 2.3 2.60 2.60 2.59 2.6
Amps 5.5 5.5 5.5 5.6 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.3 8.2 8.2 8.1 8.2 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.5
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
7
Expanded Cooling Data — GLXS3BN3010A+ CAPTA3026A
8
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 29.2 29.6 30.5 – 29.0 29.4 30.2 – 28.2 28.6 29.5 – 26.9 27.3 28.2 – 25.3 25.7 26.6 – 23.8 24.3 25.1 –
S/T 0.62 0.54 0.41 – 0.62 0.55 0.42 – 0.65 0.57 0.44 – 0.67 0.59 0.46 – 0.69 0.61 0.48 – 0.74 0.66 0.53 –
875 T 20 19 15
–
20 19 15
–
21 19 15
–
20 18 15
–
20 18 15
–
21 19 16
–
kW 1.82 1.82 1.82 – 2.05 2.05 2.04 – 2.30 2.30 2.29 – 2.57 2.57 2.57 – 2.88 2.88 2.87 – 3.23 3.23 3.23 –
Amps 6.9 6.9 6.9 – 8.0 8.0 7.9 – 9.1 9.1 9.1 – 10.4 10.4 10.3 – 11.8 11.7 11.7 – 13.4 13.4 13.4 –
MBh 29.5 29.9 30.8 – 29.2 29.6 30.5 – 28.5 28.9 29.7 – 27.2 27.6 28.4 – 25.6 26.0 26.8 – 24.1 24.5 25.4 –
S/T 0.65 0.58 0.44 – 0.66 0.58 0.45 – 0.68 0.61 0.47 – 0.70 0.62 0.49 – 0.72 0.65 0.51 – 0.77 0.70 0.56 –
70 950 T 20 18 14
–
20 18 14
–
20 18 14
–
20 18 14
–
19 18 14
–
21 19 15
–
kW 1.83 1.83 1.82 – 2.06 2.05 2.05 – 2.31 2.31 2.30 – 2.58 2.58 2.57 – 2.88 2.88 2.88 – 3.24 3.24 3.24 –
Amps 7.0 7.0 6.9 – 8.0 8.0 8.0 – 9.1 9.1 9.1 – 10.4 10.4 10.4 – 11.8 11.8 11.8 – 13.4 13.4 13.4 –
MBh 30.2 30.6 31.5 – 29.9 30.3 31.2 – 29.2 29.6 30.4 – 27.9 28.3 29.1 – 26.3 26.7 27.5 – 24.8 25.2 26.1 –
S/T 0.69 0.62 0.48 – 0.70 0.62 0.49 – 0.72 0.65 0.51 – 0.74 0.67 0.53 – 0.76 0.69 0.55 – 1.00 0.74 0.60 –
1125 T 18 16 13
–
18 16 13
–
19 17 13
–
18 16 13
–
18 16 12
–
19 17 14
–
kW 1.84 1.84 1.84 – 2.07 2.07 2.06 – 2.32 2.32 2.32 – 2.59 2.59 2.59 – 2.90 2.90 2.89 – 3.26 3.25 3.25 –
Amps 7.0 7.0 7.0 – 8.1 8.1 8.0 – 9.2 9.2 9.2 – 10.5 10.4 10.4 – 11.8 11.8 11.8 – 13.5 13.5 13.5 –
www.goodmanmfg.com
MBh 29.2 29.7 30.5 31.9 29.0 29.4 30.3 31.6 28.2 28.6 29.5 30.8 26.9 27.3 28.2 29.5 25.3 25.7 26.6 27.9 23.9 24.3 25.1 26.5
S/T 0.74 0.67 0.54 0.4 0.75 0.67 0.54 0.4 0.77 0.70 0.57 0.4 0.79 0.72 0.58 0.4 1.00 0.74 0.61 0.5 1.00 0.79 0.66 0.5
875 T 25 23 19 15 25 23 19 15 25 23 19 16 25 23 19 15 24 22 19 15 26 24 20 16
kW 1.82 1.82 1.82 1.8 2.05 2.05 2.04 2.1 2.30 2.30 2.29 2.3 2.57 2.57 2.57 2.6 2.88 2.87 2.87 2.9 3.23 3.23 3.23 3.2
Amps 6.9 6.9 6.9 7.0 8.0 7.9 7.9 8.0 9.1 9.1 9.1 9.2 10.4 10.3 10.3 10.4 11.7 11.7 11.7 11.8 13.4 13.4 13.4 13.4
MBh 29.5 29.9 30.8 32.1 29.2 29.6 30.5 31.8 28.5 28.9 29.8 31.1 27.2 27.6 28.4 29.8 25.6 26.0 26.9 28.2 24.1 24.5 25.4 26.7
S/T 0.78 0.70 0.57 0.4 0.78 0.71 0.57 0.4 0.81 0.73 0.60 0.5 0.82 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.82 0.69 0.6
75 950 T 24 22 18 15 24 22 18 15 24 22 19 15 24 22 18 15 24 22 18 14 25 23 19 16
kW 1.83 1.83 1.82 1.84 2.05 2.05 2.05 2.07 2.31 2.30 2.30 2.32 2.58 2.58 2.57 2.59 2.88 2.88 2.88 2.89 3.24 3.24 3.23 3.25
Amps 7.0 6.9 6.9 7.0 8.0 8.0 8.0 8.0 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.4 11.8 11.8 11.8 11.8 13.4 13.4 13.4 13.5
MBh 30.2 30.6 31.5 32.8 29.9 30.4 31.2 32.6 29.2 29.6 30.5 31.8 27.9 28.3 29.2 30.5 26.3 26.7 27.6 28.9 24.8 25.2 26.1 27.4
S/T 0.82 0.74 0.61 0.5 0.82 0.75 0.62 0.5 0.85 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.81 0.68 0.5 1.00 0.86 0.73 0.6
1125 T 23 21 17 13 23 21 17 13 23 21 17 14 23 21 17 13 22 20 17 13 24 22 18 14
kW 1.84 1.84 1.84 1.9 2.07 2.07 2.06 2.1 2.32 2.32 2.31 2.3 2.59 2.59 2.59 2.6 2.90 2.89 2.89 2.9 3.25 3.25 3.25 3.3
Amps 7.0 7.0 7.0 7.1 8.1 8.0 8.0 8.1 9.2 9.2 9.2 9.3 10.5 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.5
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 29.4 29.8 30.7 32.0 29.1 29.5 30.4 31.7 28.4 28.8 29.7 31.0 27.1 27.5 28.4 29.7 25.5 25.9 26.8 28.1 24.0 24.4 25.3 26.6
S/T 0.86 0.79 0.66 0.5 0.87 0.80 0.66 0.5 1.00 0.82 0.69 0.5 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 0.91 0.78 0.6
875 T 29 27 23 20 29 27 23 20 29 27 24 20 29 27 23 20 29 27 23 19 30 28 24 21 kW 1.82 1.82 1.82 1.8 2.05 2.05 2.04 2.1 2.30 2.30 2.29 2.3 2.57 2.57 2.57 2.6 2.88 2.87 2.87 2.9 3.23 3.23 3.23 3.2
Amps 6.9 6.9 6.9 7.0 8.0 8.0 7.9 8.0 9.1 9.1 9.1 9.2 10.4 10.4 10.3 10.4 11.8 11.7 11.7 11.8 13.4 13.4 13.4 13.4
MBh 29.6 30.1 30.9 32.3 29.4 29.8 30.7 32.0 28.6 29.0 29.9 31.2 27.3 27.7 28.6 29.9 25.7 26.1 27.0 28.3 24.3 24.7 25.5 26.9
S/T 0.90 0.82 0.69 0.6 0.90 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.94 0.81 0.7
80 950 T 28 26 23 19 28 26 23 19 29 27 23 19 28 26 23 19 28 26 22 19 29 27 24 20 kW 1.83 1.83 1.82 1.84 2.06 2.05 2.05 2.07 2.31 2.31 2.30 2.32 2.58 2.58 2.57 2.59 2.88 2.88 2.88 2.90 3.24 3.24 3.24 3.25
Amps 7.0 7.0 6.9 7.0 8.0 8.0 8.0 8.0 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.4 11.8 11.8 11.8 11.8 13.4 13.4 13.4 13.5
MBh 30.4 30.8 31.6 33.0 30.1 30.5 31.4 32.7 29.3 29.7 30.6 31.9 28.0 28.4 29.3 30.6 26.4 26.8 27.7 29.0 25.0 25.4 26.3 27.6
S/T 0.94 0.86 0.73 0.6 1.00 0.87 0.74 0.6 1.00 0.89 0.76 0.6 1.00 0.91 0.78 0.6 1.00 0.94 0.80 0.7 1.00 1.00 0.85 0.7
1125 T 27 25 21 18 27 25 21 18 27 25 22 18 27 25 21 18 27 25 21 17 28 26 22 19
kW 1.84 1.84 1.84 1.9 2.07 2.07 2.06 2.1 2.32 2.32 2.32 2.3 2.59 2.59 2.59 2.6 2.90 2.90 2.89 2.9 3.25 3.25 3.25 3.3
Amps 7.0 7.0 7.0 7.1 8.1 8.0 8.0 8.1 9.2 9.2 9.2 9.3 10.5 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.5
Expanded Cooling Data — GLXS3BN3010A+ CAPTA3026A (cont.)
www.goodmanmfg.com
MBh 29.9 30.3 31.2 32.5 29.6 30.0 30.9 32.2 28.9 29.3 30.1 31.5 27.6 28.0 28.8 30.2 26.0 26.4 27.2 28.6 24.5 24.9 25.8 27.1
S/T 1.00 0.89 0.76 0.6 1.00 0.89 0.76 0.6 1.00 0.92 0.79 0.6 1.00 0.94 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.88 0.7
875 T 33 31 27 24 33 31 27 23 33 31 28 24 33 31 27 23 33 31 27 23 34 32 28 24
kW 1.83 1.83 1.82 1.8 2.05 2.05 2.05 2.1 2.30 2.30 2.30 2.3 2.58 2.57 2.57 2.6 2.88 2.88 2.88 2.9 3.24 3.24 3.23 3.2
Amps 6.9 6.9 6.9 7.0 8.0 8.0 8.0 8.0 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.4 11.8 11.8 11.7 11.8 13.4 13.4 13.4 13.5
MBh 30.1 30.5 31.4 32.7 29.9 30.3 31.2 32.5 29.1 29.5 30.4 31.7 27.8 28.2 29.1 30.4 26.2 26.6 27.5 28.8 24.8 25.2 26.0 27.4
S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 0.95 0.82 0.7 1.00 0.97 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8
85 950 T 32 30 27 23 32 30 27 23 32 30 27 23 32 30 27 23 32 30 26 23 33 31 27 24
kW 1.83 1.83 1.83 1.85 2.06 2.06 2.05 2.07 2.31 2.31 2.31 2.32 2.58 2.58 2.58 2.60 2.89 2.89 2.88 2.90 3.25 3.24 3.24 3.26
Amps 7.0 7.0 7.0 7.0 8.0 8.0 8.0 8.1 9.2 9.2 9.1 9.2 10.4 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.4 13.4 13.4 13.5
MBh 30.8 31.3 32.1 33.5 30.6 31.0 31.9 33.2 29.8 30.2 31.1 32.4 28.5 28.9 29.8 31.1 26.9 27.3 28.2 29.5 25.5 25.9 26.7 28.1
S/T 1.00 0.96 0.83 0.7 1.00 0.97 0.84 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8
1125 T 31 29 25 21 31 29 25 21 31 29 25 22 31 29 25 21 30 28 25 21 32 30 26 22
kW 1.85 1.85 1.84 1.9 2.07 2.07 2.07 2.1 2.33 2.32 2.32 2.3 2.60 2.60 2.59 2.6 2.90 2.90 2.90 2.9 3.26 3.26 3.25 3.3
Amps 7.0 7.0 7.0 7.1 8.1 8.1 8.1 8.1 9.2 9.2 9.2 9.3 10.5 10.5 10.4 10.5 11.9 11.9 11.8 11.9 13.5 13.5 13.5 13.6
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
9
Expanded Cooling Data — GLXS3BN3610A+ CAPTA3626A
10
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 34.9 35.4 36.5 – 34.6 35.1 36.1 – 33.7 34.2 35.2 – 32.1 32.6 33.7 – 30.2 30.7 31.8 – 28.5 29.0 30.0 –
S/T 0.63 0.55 0.42 – 0.64 0.56 0.42 – 0.66 0.58 0.45 – 1.00 0.60 0.47 – 1.00 0.63 0.49 – 1.00 0.68 0.54 –
1050 T 20 18 15
–
20 18 15
–
20 18 15
–
20 18 15
–
20 18 14
–
21 19 15
–
kW 2.19 2.19 2.19 – 2.46 2.46 2.45 – 2.75 2.75 2.75 – 3.08 3.07 3.07 – 3.43 3.43 3.43 – 3.85 3.85 3.85 –
Amps 8.0 8.0 8.0 – 9.2 9.2 9.2 – 10.6 10.6 10.6 – 12.1 12.0 12.0 – 13.7 13.7 13.7 – 15.6 15.6 15.6 –
MBh 35.3 35.7 36.8 – 34.9 35.4 36.5 – 34.0 34.5 35.6 – 32.5 33.0 34.0 – 30.6 31.0 32.1 – 28.8 29.3 30.3 –
S/T 0.67 0.59 0.46 – 0.67 0.60 0.46 – 1.00 0.62 0.49 – 1.00 0.64 0.51 – 1.00 0.66 0.53 – 1.00 0.72 0.58 –
70 1150 T 19 17 14
–
19 17 14
–
19 18 14
–
19 17 14
–
19 17 14
–
20 18 15
–
kW 2.20 2.20 2.20 – 2.47 2.47 2.46 – 2.76 2.76 2.76 – 3.08 3.08 3.08 – 3.44 3.44 3.44 – 3.86 3.86 3.86 –
Amps 8.1 8.1 8.0 – 9.3 9.3 9.2 – 10.6 10.6 10.6 – 12.1 12.1 12.1 – 13.7 13.7 13.7 – 15.7 15.6 15.6 –
MBh 36.0 36.5 37.6 – 35.7 36.2 37.3 – 34.8 35.3 36.4 – 33.3 33.8 34.8 – 31.4 31.8 32.9 – 29.6 30.1 31.1 –
S/T 0.71 0.63 0.50 – 0.72 0.64 0.50 – 1.00 0.66 0.53 – 1.00 0.68 0.55 – 1.00 0.71 0.57 – 1.00 1.00 0.62 –
1350 T 18 16 13
–
18 16 12
–
18 16 13
–
18 16 12
–
18 16 12
–
19 17 13
–
kW 2.22 2.22 2.21 – 2.48 2.48 2.48 – 2.78 2.78 2.77 – 3.10 3.10 3.09 – 3.46 3.46 3.45 – 3.88 3.88 3.87 –
Amps 8.1 8.1 8.1 – 9.4 9.3 9.3 – 10.7 10.7 10.7 – 12.2 12.2 12.1 – 13.8 13.8 13.8 – 15.7 15.7 15.7 –
www.goodmanmfg.com
MBh 34.9 35.4 36.5 38.1 34.6 35.1 36.2 37.8 33.7 34.2 35.3 36.8 32.2 32.7 33.7 35.3 30.3 30.7 31.8 33.4 28.5 29.0 30.0 31.6
S/T 0.76 0.68 0.55 0.4 1.00 0.69 0.55 0.4 1.00 0.71 0.58 0.4 1.00 0.73 0.60 0.5 1.00 1.00 0.62 0.5 1.00 1.00 0.67 0.5
1050 T 24 22 19 15 24 22 19 15 24 23 19 15 24 22 19 15 24 22 18 15 25 23 20 16
kW 2.19 2.19 2.19 2.2 2.46 2.46 2.45 2.5 2.75 2.75 2.75 2.8 3.07 3.07 3.07 3.1 3.43 3.43 3.42 3.4 3.85 3.85 3.84 3.9
Amps 8.0 8.0 8.0 8.1 9.2 9.2 9.2 9.3 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 13.7 13.7 13.7 13.7 15.6 15.6 15.6 15.7
MBh 35.3 35.8 36.8 38.4 35.0 35.5 36.5 38.1 34.1 34.5 35.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.8 29.3 30.4 32.0
S/T 0.80 0.72 0.58 0.4 1.00 0.73 0.59 0.4 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 1.00 0.66 0.5 1.00 1.00 0.71 0.6
75 1150 T 23 22 18 14 23 21 18 14 24 22 18 15 23 21 18 14 23 21 18 14 24 22 19 15
kW 2.20 2.20 2.20 2.22 2.47 2.46 2.46 2.48 2.76 2.76 2.76 2.78 3.08 3.08 3.08 3.10 3.44 3.44 3.43 3.45 3.86 3.86 3.85 3.87
Amps 8.1 8.0 8.0 8.1 9.3 9.3 9.2 9.3 10.6 10.6 10.6 10.7 12.1 12.1 12.1 12.2 13.7 13.7 13.7 13.8 15.6 15.6 15.6 15.7
MBh 36.1 36.6 37.6 39.2 35.8 36.2 37.3 38.9 34.8 35.3 36.4 38.0 33.3 33.8 34.8 36.4 31.4 31.9 32.9 34.5 29.6 30.1 31.2 32.7
S/T 0.84 0.76 0.63 0.5 1.00 0.77 0.63 0.5 1.00 0.79 0.66 0.5 1.00 0.81 0.68 0.5 1.00 1.00 0.70 0.6 1.00 1.00 0.75 0.6
1350 T 22 20 17 13 22 20 17 13 22 20 17 13 22 20 17 13 22 20 16 13 23 21 18 14
kW 2.22 2.22 2.21 2.2 2.48 2.48 2.48 2.5 2.78 2.78 2.77 2.8 3.10 3.10 3.09 3.1 3.46 3.45 3.45 3.5 3.88 3.87 3.87 3.9
Amps 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.1 12.2 13.8 13.8 13.8 13.9 15.7 15.7 15.7 15.8
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 35.1 35.6 36.7 38.2 34.8 35.3 36.3 37.9 33.9 34.4 35.4 37.0 32.3 32.8 33.9 35.5 30.4 30.9 32.0 33.6 28.7 29.2 30.2 31.8
S/T 1.00 0.81 0.67 0.5 1.00 0.81 0.68 0.5 1.00 0.84 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.80 0.7
1050 T 28 26 23 19 28 26 23 19 29 27 23 20 28 26 23 19 28 26 23 19 29 27 24 20 kW 2.19 2.19 2.19 2.2 2.46 2.46 2.45 2.5 2.75 2.75 2.75 2.8 3.07 3.07 3.07 3.1 3.43 3.43 3.43 3.4 3.85 3.85 3.85 3.9
Amps 8.0 8.0 8.0 8.1 9.2 9.2 9.2 9.3 10.6 10.6 10.6 10.7 12.1 12.0 12.0 12.1 13.7 13.7 13.7 13.8 15.6 15.6 15.6 15.7
MBh 35.5 35.9 37.0 38.6 35.1 35.6 36.7 38.3 34.2 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.2 32.3 33.9 29.0 29.5 30.5 32.1
S/T 1.00 0.85 0.71 0.6 1.00 0.85 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 1.00 0.7
80 1150 T 28 26 22 19 28 26 22 18 28 26 22 19 28 26 22 18 27 25 22 18 28 27 23 19 kW 2.20 2.20 2.20 2.22 2.47 2.47 2.46 2.48 2.76 2.76 2.76 2.78 3.08 3.08 3.08 3.10 3.44 3.44 3.44 3.46 3.86 3.86 3.85 3.88
Amps 8.1 8.1 8.0 8.1 9.3 9.3 9.2 9.3 10.6 10.6 10.6 10.7 12.1 12.1 12.1 12.2 13.7 13.7 13.7 13.8 15.7 15.6 15.6 15.7
MBh 36.2 36.7 37.8 39.4 35.9 36.4 37.5 39.1 35.0 35.5 36.6 38.1 33.5 34.0 35.0 36.6 31.6 32.0 33.1 34.7 29.8 30.3 31.3 32.9
S/T 1.00 0.89 0.75 0.6 1.00 0.89 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7
1350 T 26 24 21 17 26 24 21 17 27 25 21 17 26 24 21 17 26 24 21 17 27 25 22 18
kW 2.22 2.22 2.21 2.2 2.48 2.48 2.48 2.5 2.78 2.78 2.77 2.8 3.10 3.10 3.09 3.1 3.46 3.46 3.45 3.5 3.88 3.88 3.87 3.9
Amps 8.1 8.1 8.1 8.2 9.3 9.3 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.1 12.2 13.8 13.8 13.8 13.9 15.7 15.7 15.7 15.8
Expanded Cooling Data — GLXS3BN3610A+ CAPTA3626A (cont.)
www.goodmanmfg.com
MBh 35.7 36.2 37.2 38.8 35.4 35.9 36.9 38.5 34.5 35.0 36.0 37.6 32.9 33.4 34.5 36.0 31.0 31.5 32.5 34.1 29.3 29.8 30.8 32.4
S/T 1.00 0.91 0.77 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8
1050 T 32 30 27 23 32 30 27 23 32 30 27 23 32 30 27 23 32 30 26 23 33 31 28 24
kW 2.20 2.20 2.19 2.2 2.46 2.46 2.46 2.5 2.76 2.76 2.75 2.8 3.08 3.08 3.07 3.1 3.44 3.44 3.43 3.5 3.86 3.86 3.85 3.9
Amps 8.0 8.0 8.0 8.1 9.3 9.2 9.2 9.3 10.6 10.6 10.6 10.7 12.1 12.1 12.0 12.1 13.7 13.7 13.7 13.8 15.6 15.6 15.6 15.7
MBh 36.0 36.5 37.6 39.2 35.7 36.2 37.3 38.8 34.8 35.3 36.3 37.9 33.3 33.7 34.8 36.4 31.3 31.8 32.9 34.5 29.6 30.1 31.1 32.7
S/T 1.00 0.95 0.81 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8
85 1150 T 31 29 26 22 31 29 26 22 32 30 26 22 31 29 26 22 31 29 26 22 32 30 27 23
kW 2.21 2.21 2.20 2.22 2.47 2.47 2.47 2.49 2.77 2.77 2.76 2.78 3.09 3.09 3.08 3.10 3.45 3.44 3.44 3.46 3.87 3.86 3.86 3.88
Amps 8.1 8.1 8.1 8.1 9.3 9.3 9.3 9.4 10.7 10.6 10.6 10.7 12.1 12.1 12.1 12.2 13.8 13.7 13.7 13.8 15.7 15.7 15.6 15.7
MBh 36.8 37.3 38.4 39.9 36.5 37.0 38.1 39.6 35.6 36.1 37.1 38.7 34.0 34.5 35.6 37.2 32.1 32.6 33.7 35.3 30.4 30.9 31.9 33.5
S/T 1.00 1.00 0.85 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8
1350 T 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 31 29 25 22
kW 2.22 2.22 2.22 2.2 2.49 2.49 2.48 2.5 2.78 2.78 2.78 2.8 3.10 3.10 3.10 3.1 3.46 3.46 3.46 3.5 3.88 3.88 3.88 3.9
Amps 8.2 8.1 8.1 8.2 9.4 9.4 9.3 9.4 10.7 10.7 10.7 10.8 12.2 12.2 12.2 12.3 13.8 13.8 13.8 13.9 15.7 15.7 15.7 15.8
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
11
Expanded Cooling Data — GLXS3BN4210A+ CAPTA4230A
12
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 40.3 40.8 42.0 – 39.9 40.5 41.7 – 38.9 39.4 40.6 – 37.1 37.6 38.8 – 34.9 35.4 36.6 – 32.8 33.4 34.6 –
S/T 0.62 0.54 0.41 – 0.62 0.55 0.41 – 0.65 0.57 0.44 – 0.67 0.59 0.46 – 1.00 0.61 0.48 – 1.00 0.67 0.53 –
1225 T 20 18 15
–
20 18 14
–
20 18 15
–
20 18 14
–
20 18 14
–
21 19 15
–
kW 2.61 2.61 2.61 – 2.89 2.89 2.89 – 3.21 3.21 3.20 – 3.55 3.55 3.54 – 3.93 3.92 3.92 – 4.37 4.37 4.37 –
Amps 9.2 9.2 9.2 – 10.5 10.5 10.5 – 11.9 11.9 11.9 – 13.5 13.5 13.5 – 15.2 15.2 15.2 – 17.3 17.2 17.2 –
MBh 40.7 41.3 42.5 – 40.4 40.9 42.1 – 39.3 39.9 41.1 – 37.5 38.1 39.3 – 35.3 35.9 37.1 – 33.3 33.8 35.0 –
S/T 0.67 0.59 0.45 – 0.67 0.60 0.46 – 0.70 0.62 0.48 – 1.00 0.64 0.50 – 1.00 0.66 0.53 – 1.00 0.71 0.58 –
70 1365 T 19 17 14
–
19 17 14
–
19 17 14
–
19 17 14
–
19 17 13
–
20 18 14
–
kW 2.63 2.62 2.62 – 2.91 2.90 2.90 – 3.22 3.22 3.21 – 3.56 3.56 3.55 – 3.94 3.94 3.93 – 4.38 4.38 4.38 –
Amps 9.3 9.2 9.2 – 10.5 10.5 10.5 – 12.0 12.0 11.9 – 13.5 13.5 13.5 – 15.3 15.3 15.2 – 17.3 17.3 17.3 –
MBh 41.5 42.1 43.3 – 41.2 41.7 42.9 – 40.1 40.7 41.9 – 38.3 38.9 40.1 – 36.1 36.7 37.9 – 34.1 34.6 35.8 –
S/T 0.70 0.63 0.49 – 0.71 0.63 0.50 – 0.73 0.66 0.52 – 1.00 0.68 0.54 – 1.00 0.70 0.56 – 1.00 0.75 0.62 –
1575 T 18 16 12
–
18 16 12
–
18 16 13
–
18 16 12
–
17 16 12
–
19 17 13
–
kW 2.64 2.64 2.63 – 2.92 2.92 2.91 – 3.23 3.23 3.23 – 3.57 3.57 3.57 – 3.95 3.95 3.95 – 4.40 4.40 4.39 –
Amps 9.3 9.3 9.3 – 10.6 10.6 10.6 – 12.0 12.0 12.0 – 13.6 13.6 13.6 – 15.3 15.3 15.3 – 17.4 17.4 17.3 –
www.goodmanmfg.com
MBh 40.3 40.9 42.1 43.9 39.9 40.5 41.7 43.5 38.9 39.5 40.7 42.5 37.1 37.7 38.9 40.7 34.9 35.4 36.6 38.5 32.9 33.4 34.6 36.5
S/T 0.75 0.67 0.54 0.4 0.75 0.68 0.54 0.4 1.00 0.70 0.57 0.4 1.00 0.72 0.59 0.4 1.00 0.74 0.61 0.5 1.00 1.00 0.66 0.5
1225 T 24 22 19 15 24 22 19 15 24 22 19 15 24 22 19 15 24 22 18 15 25 23 19 16
kW 2.61 2.61 2.60 2.6 2.89 2.89 2.89 2.9 3.21 3.20 3.20 3.2 3.55 3.54 3.54 3.6 3.93 3.92 3.92 3.9 4.37 4.37 4.36 4.4
Amps 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 12.0 13.5 13.5 13.4 13.5 15.2 15.2 15.2 15.3 17.2 17.2 17.2 17.3
MBh 40.7 41.3 42.5 44.3 40.4 40.9 42.1 44.0 39.3 39.9 41.1 42.9 37.5 38.1 39.3 41.1 35.3 35.9 37.1 38.9 33.3 33.9 35.1 36.9
S/T 0.79 0.72 0.58 0.4 0.80 0.72 0.59 0.4 1.00 0.75 0.61 0.5 1.00 0.77 0.63 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6
75 1365 T 23 21 18 14 23 21 18 14 23 21 18 14 23 21 18 14 23 21 17 14 24 22 19 15
kW 2.62 2.62 2.62 2.64 2.90 2.90 2.90 2.92 3.22 3.22 3.21 3.23 3.56 3.56 3.55 3.57 3.94 3.93 3.93 3.95 4.38 4.38 4.38 4.40
Amps 9.3 9.2 9.2 9.3 10.5 10.5 10.5 10.6 12.0 12.0 11.9 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.2 15.3 17.3 17.3 17.3 17.4
MBh 41.5 42.1 43.3 45.1 41.2 41.7 42.9 44.8 40.1 40.7 41.9 43.7 38.3 38.9 40.1 41.9 36.1 36.7 37.9 39.7 34.1 34.7 35.9 37.7
S/T 0.83 0.76 0.62 0.5 1.00 0.76 0.63 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.69 0.6 1.00 1.00 0.75 0.6
1575 T 22 20 17 13 22 20 17 13 22 20 17 13 22 20 17 13 22 20 16 13 23 21 17 14
kW 2.64 2.64 2.63 2.7 2.92 2.92 2.91 2.9 3.23 3.23 3.23 3.2 3.57 3.57 3.57 3.6 3.95 3.95 3.94 4.0 4.40 4.39 4.39 4.4
Amps 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.0 12.0 12.0 12.1 13.6 13.6 13.6 13.7 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 40.5 41.1 42.3 44.1 40.1 40.7 41.9 43.7 39.1 39.7 40.9 42.7 37.3 37.9 39.1 40.9 35.1 35.7 36.9 38.7 33.1 33.6 34.8 36.7
S/T 1.00 0.80 0.66 0.5 1.00 0.80 0.67 0.5 1.00 0.83 0.69 0.5 1.00 0.85 0.71 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.79 0.6
1225 T 28 26 23 19 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 29 27 24 20 kW 2.61 2.61 2.61 2.6 2.89 2.89 2.89 2.9 3.21 3.21 3.20 3.2 3.55 3.55 3.54 3.6 3.93 3.92 3.92 3.9 4.37 4.37 4.36 4.4
Amps 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.6 11.9 11.9 11.9 12.0 13.5 13.5 13.4 13.5 15.2 15.2 15.2 15.3 17.3 17.2 17.2 17.3
MBh 40.9 41.5 42.7 44.5 40.6 41.2 42.4 44.2 39.5 40.1 41.3 43.1 37.7 38.3 39.5 41.3 35.5 36.1 37.3 39.1 33.5 34.1 35.3 37.1
S/T 1.00 0.84 0.71 0.6 1.00 0.85 0.71 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7
80 1365 T 27 25 22 18 27 25 22 18 27 26 22 18 27 25 22 18 27 25 22 18 28 26 23 19 kW 2.62 2.62 2.62 2.64 2.91 2.90 2.90 2.92 3.22 3.22 3.21 3.23 3.56 3.56 3.55 3.57 3.94 3.94 3.93 3.95 4.38 4.38 4.38 4.40
Amps 9.3 9.2 9.2 9.3 10.5 10.5 10.5 10.6 12.0 12.0 11.9 12.0 13.5 13.5 13.5 13.6 15.3 15.3 15.2 15.3 17.3 17.3 17.3 17.4
MBh 41.7 42.3 43.5 45.3 41.4 42.0 43.2 45.0 40.3 40.9 42.1 43.9 38.5 39.1 40.3 42.1 36.3 36.9 38.1 39.9 34.3 34.9 36.1 37.9
S/T 1.00 0.88 0.75 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7
1575 T 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 26 24 20 17 27 25 22 18
kW 2.64 2.64 2.63 2.7 2.92 2.92 2.91 2.9 3.23 3.23 3.23 3.2 3.57 3.57 3.57 3.6 3.95 3.95 3.95 4.0 4.40 4.40 4.39 4.4
Amps 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.0 12.0 12.0 12.1 13.6 13.6 13.6 13.7 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4
Expanded Cooling Data — GLXS3BN4210A+ CAPTA4230A (cont.)
www.goodmanmfg.com
MBh 41.2 41.8 43.0 44.8 40.8 41.4 42.6 44.4 39.8 40.3 41.5 43.4 38.0 38.5 39.7 41.6 35.8 36.3 37.5 39.4 33.7 34.3 35.5 37.3
S/T 1.00 0.90 0.76 0.6 1.00 0.90 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 1.00 0.7
1225 T 32 30 26 23 32 30 26 23 32 30 27 23 32 30 26 23 31 30 26 22 33 31 27 24
kW 2.62 2.62 2.61 2.6 2.90 2.90 2.89 2.9 3.21 3.21 3.21 3.2 3.55 3.55 3.55 3.6 3.93 3.93 3.93 3.9 4.38 4.38 4.37 4.4
Amps 9.2 9.2 9.2 9.3 10.5 10.5 10.5 10.6 12.0 11.9 11.9 12.0 13.5 13.5 13.5 13.6 15.2 15.2 15.2 15.3 17.3 17.3 17.2 17.3
MBh 41.6 42.2 43.4 45.2 41.3 41.8 43.0 44.9 40.2 40.8 42.0 43.8 38.4 39.0 40.2 42.0 36.2 36.8 38.0 39.8 34.2 34.8 36.0 37.8
S/T 1.00 0.94 0.81 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8
85 1365 T 31 29 25 22 31 29 25 22 31 29 26 22 31 29 25 22 30 29 25 22 32 30 26 23
kW 2.63 2.63 2.62 2.64 2.91 2.91 2.90 2.93 3.22 3.22 3.22 3.24 3.56 3.56 3.56 3.58 3.94 3.94 3.94 3.96 4.39 4.39 4.38 4.40
Amps 9.3 9.3 9.3 9.3 10.6 10.6 10.5 10.6 12.0 12.0 12.0 12.1 13.6 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4
MBh 42.4 43.0 44.2 46.0 42.1 42.6 43.8 45.7 41.0 41.6 42.8 44.6 39.2 39.8 41.0 42.8 37.0 37.6 38.8 40.6 35.0 35.6 36.8 38.6
S/T 1.00 0.98 0.85 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8
1575 T 30 28 24 21 30 28 24 21 30 28 25 21 30 28 24 21 29 27 24 20 31 29 25 22
kW 2.64 2.64 2.64 2.7 2.93 2.92 2.92 2.9 3.24 3.24 3.23 3.3 3.58 3.58 3.57 3.6 3.96 3.96 3.95 4.0 4.40 4.40 4.40 4.4
Amps 9.4 9.3 9.3 9.4 10.6 10.6 10.6 10.7 12.1 12.1 12.0 12.1 13.6 13.6 13.6 13.7 15.4 15.4 15.3 15.4 17.4 17.4 17.4 17.5
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
13
Expanded Cooling Data — GLXS3BN4810A+ CAPTA6030A
14
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 46.9 47.6 48.9 – 46.5 47.1 48.5 – 45.3 45.9 47.3 – 43.2 43.9 45.2 – 40.7 41.3 42.7 – 38.3 39.0 40.4 –
S/T 0.64 0.56 0.43 – 0.64 0.57 0.44 – 0.67 0.59 0.46 – 1.00 0.61 0.48 – 1.00 0.63 0.50 – 1.00 0.68 0.55 –
1400 T 20 18 15
–
20 18 14
–
20 18 15
–
20 18 14
–
20 18 14
–
21 19 15
–
kW 3.03 3.03 3.02 – 3.37 3.37 3.37 – 3.76 3.76 3.75 – 4.18 4.17 4.17 – 4.64 4.64 4.63 – 5.19 5.19 5.18 –
Amps 11.0 11.0 11.0 – 12.6 12.6 12.6 – 14.4 14.4 14.3 – 16.3 16.3 16.3 – 18.4 18.4 18.4 – 20.9 20.9 20.9 –
MBh 47.7 48.4 49.8 – 47.3 48.0 49.4 – 46.1 46.8 48.2 – 44.0 44.7 46.1 – 41.5 42.2 43.5 – 39.2 39.8 41.2 –
S/T 0.67 0.60 0.47 – 0.68 0.60 0.48 – 0.70 0.63 0.50 – 1.00 0.65 0.52 – 1.00 0.67 0.54 – 1.00 0.72 0.59 –
70 1600 T 19 17 13
–
19 17 13
–
19 17 14
–
19 17 13
–
19 17 13
–
20 18 14
–
kW 3.05 3.04 3.04 – 3.39 3.39 3.38 – 3.78 3.77 3.77 – 4.19 4.19 4.18 – 4.66 4.66 4.65 – 5.21 5.20 5.20 –
Amps 11.1 11.1 11.1 – 12.7 12.7 12.7 – 14.5 14.4 14.4 – 16.4 16.4 16.3 – 18.5 18.5 18.5 – 21.0 21.0 21.0 –
MBh 48.8 49.4 50.8 – 48.4 49.0 50.4 – 47.2 47.8 49.2 – 45.1 45.7 47.1 – 42.5 43.2 44.6 – 40.2 40.9 42.3 –
S/T 0.68 0.61 0.48 – 0.68 0.61 0.48 – 1.00 0.64 0.51 – 1.00 0.65 0.53 – 1.00 0.68 0.55 – 1.00 0.72 0.60 –
1800 T 18 16 12
–
18 16 12
–
18 16 13
–
18 16 12
–
18 16 12
–
19 17 13
–
kW 3.06 3.06 3.05 – 3.41 3.40 3.40 – 3.79 3.79 3.78 – 4.21 4.21 4.20 – 4.67 4.67 4.67 – 5.22 5.22 5.21 –
Amps 11.2 11.2 11.1 – 12.8 12.8 12.7 – 14.5 14.5 14.5 – 16.4 16.4 16.4 – 18.6 18.6 18.5 – 21.1 21.1 21.0 –
www.goodmanmfg.com
MBh 46.9 47.6 49.0 51.1 46.5 47.2 48.5 50.7 45.3 46.0 47.3 49.5 43.2 43.9 45.3 47.4 40.7 41.3 42.7 44.8 38.4 39.0 40.4 42.5
S/T 0.76 0.69 0.56 0.4 0.77 0.69 0.56 0.4 1.00 0.72 0.59 0.5 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 1.00 0.68 0.5
1400 T 25 23 19 15 24 23 19 15 25 23 19 15 24 22 19 15 24 22 19 15 25 23 20 16
kW 3.03 3.02 3.02 3.0 3.37 3.37 3.36 3.4 3.76 3.75 3.75 3.8 4.17 4.17 4.17 4.2 4.64 4.64 4.63 4.7 5.19 5.18 5.18 5.2
Amps 11.0 11.0 11.0 11.1 12.6 12.6 12.6 12.7 14.4 14.4 14.3 14.5 16.3 16.3 16.2 16.4 18.4 18.4 18.4 18.5 20.9 20.9 20.9 21.0
MBh 47.8 48.4 49.8 51.9 47.4 48.0 49.4 51.5 46.1 46.8 48.2 50.3 44.1 44.7 46.1 48.2 41.5 42.2 43.6 45.7 39.2 39.9 41.2 43.4
S/T 0.79 0.72 0.59 0.5 1.00 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6
75 1600 T 23 21 18 14 23 21 18 14 24 22 18 14 23 21 18 14 23 21 17 14 24 22 19 15
kW 3.04 3.04 3.03 3.06 3.39 3.39 3.38 3.41 3.77 3.77 3.77 3.79 4.19 4.19 4.18 4.21 4.66 4.65 4.65 4.68 5.20 5.20 5.20 5.22
Amps 11.1 11.1 11.1 11.2 12.7 12.7 12.6 12.8 14.4 14.4 14.4 14.5 16.4 16.3 16.3 16.4 18.5 18.5 18.5 18.6 21.0 21.0 21.0 21.1
MBh 48.8 49.5 50.9 53.0 48.4 49.1 50.4 52.5 47.2 47.8 49.2 51.3 45.1 45.8 47.1 49.3 42.6 43.2 44.6 46.7 40.2 40.9 42.3 44.4
S/T 0.80 0.73 0.60 0.5 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 1.00 0.67 0.5 1.00 1.00 0.72 0.6
1800 T 22 20 17 13 22 20 17 13 23 21 17 13 22 20 17 13 22 20 16 13 23 21 18 14
kW 3.06 3.06 3.05 3.1 3.40 3.40 3.39 3.4 3.79 3.79 3.78 3.8 4.21 4.20 4.20 4.2 4.67 4.67 4.66 4.7 5.22 5.22 5.21 5.2
Amps 11.2 11.2 11.1 11.3 12.8 12.7 12.7 12.8 14.5 14.5 14.5 14.6 16.4 16.4 16.4 16.5 18.6 18.5 18.5 18.6 21.1 21.0 21.0 21.1
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 47.2 47.8 49.2 51.3 46.8 47.4 48.8 50.9 45.5 46.2 47.6 49.7 43.5 44.1 45.5 47.6 40.9 41.6 43.0 45.1 38.6 39.3 40.6 42.8
S/T 1.00 0.81 0.68 0.5 1.00 0.81 0.68 0.5 1.00 0.84 0.71 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.80 0.7
1400 T 29 27 23 19 29 27 23 19 29 27 23 20 29 27 23 19 29 27 23 19 30 28 24 20 kW 3.03 3.03 3.02 3.0 3.37 3.37 3.36 3.4 3.76 3.76 3.75 3.8 4.18 4.17 4.17 4.2 4.64 4.64 4.63 4.7 5.19 5.19 5.18 5.2
Amps 11.0 11.0 11.0 11.1 12.6 12.6 12.6 12.7 14.4 14.4 14.3 14.5 16.3 16.3 16.2 16.4 18.4 18.4 18.4 18.5 20.9 20.9 20.9 21.0
MBh 48.0 48.7 50.0 52.2 47.6 48.3 49.6 51.7 46.4 47.0 48.4 50.5 44.3 45.0 46.3 48.5 41.8 42.4 43.8 45.9 39.4 40.1 41.5 43.6
S/T 1.00 0.84 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.83 0.7
80 1600 T 28 26 22 18 28 26 22 18 28 26 22 19 28 26 22 18 27 25 22 18 29 27 23 19 kW 3.05 3.04 3.04 3.06 3.39 3.39 3.38 3.41 3.78 3.77 3.77 3.79 4.19 4.19 4.18 4.21 4.66 4.66 4.65 4.68 5.21 5.20 5.20 5.22
Amps 11.1 11.1 11.1 11.2 12.7 12.7 12.7 12.8 14.5 14.4 14.4 14.5 16.4 16.4 16.3 16.4 18.5 18.5 18.5 18.6 21.0 21.0 21.0 21.1
MBh 49.1 49.7 51.1 53.2 48.6 49.3 50.7 52.8 47.4 48.1 49.5 51.6 45.4 46.0 47.4 49.5 42.8 43.5 44.8 47.0 40.5 41.1 42.5 44.6
S/T 1.00 0.85 0.72 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.84 0.7
1800 T 27 25 21 17 27 25 21 17 27 25 21 18 27 25 21 17 26 24 21 17 28 26 22 18
kW 3.06 3.06 3.05 3.1 3.41 3.40 3.40 3.4 3.79 3.79 3.78 3.8 4.21 4.21 4.20 4.2 4.67 4.67 4.67 4.7 5.22 5.22 5.21 5.2
Amps 11.2 11.2 11.1 11.3 12.8 12.7 12.7 12.8 14.5 14.5 14.5 14.6 16.4 16.4 16.4 16.5 18.6 18.6 18.5 18.6 21.1 21.1 21.0 21.2
Expanded Cooling Data — GLXS3BN4810A+ CAPTA6030A (cont.)
www.goodmanmfg.com
MBh 47.9 48.6 50.0 52.1 47.5 48.2 49.6 51.7 46.3 47.0 48.4 50.5 44.2 44.9 46.3 48.4 41.7 42.4 43.7 45.9 39.4 40.0 41.4 43.5
S/T 1.00 0.90 0.77 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 1.00 0.8
1400 T 33 31 27 23 33 31 27 23 33 31 27 24 33 31 27 23 32 30 27 23 34 32 28 24
kW 3.03 3.03 3.03 3.1 3.38 3.38 3.37 3.4 3.77 3.76 3.76 3.8 4.18 4.18 4.17 4.2 4.65 4.65 4.64 4.7 5.20 5.19 5.19 5.2
Amps 11.1 11.1 11.0 11.1 12.6 12.6 12.6 12.7 14.4 14.4 14.4 14.5 16.3 16.3 16.3 16.4 18.5 18.4 18.4 18.5 21.0 20.9 20.9 21.0
MBh 48.8 49.4 50.8 52.9 48.4 49.0 50.4 52.5 47.2 47.8 49.2 51.3 45.1 45.7 47.1 49.2 42.5 43.2 44.6 46.7 40.2 40.9 42.3 44.4
S/T 1.00 0.94 0.81 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8
85 1600 T 32 30 26 22 32 30 26 22 32 30 26 22 32 30 26 22 31 29 26 22 33 31 27 23
kW 3.05 3.05 3.04 3.07 3.40 3.39 3.39 3.41 3.78 3.78 3.77 3.80 4.20 4.20 4.19 4.22 4.67 4.66 4.66 4.68 5.21 5.21 5.20 5.23
Amps 11.1 11.1 11.1 11.2 12.7 12.7 12.7 12.8 14.5 14.5 14.4 14.6 16.4 16.4 16.4 16.5 18.5 18.5 18.5 18.6 21.0 21.0 21.0 21.1
MBh 49.8 50.5 51.9 54.0 49.4 50.1 51.5 53.6 48.2 48.9 50.2 52.4 46.1 46.8 48.2 50.3 43.6 44.2 45.6 47.7 41.3 41.9 43.3 45.4
S/T 1.00 0.95 0.82 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8
1800 T 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 30 28 25 21 32 30 26 22
kW 3.07 3.06 3.06 3.1 3.41 3.41 3.40 3.4 3.80 3.79 3.79 3.8 4.21 4.21 4.21 4.2 4.68 4.68 4.67 4.7 5.23 5.22 5.22 5.2
Amps 11.2 11.2 11.2 11.3 12.8 12.8 12.8 12.9 14.6 14.5 14.5 14.6 16.5 16.5 16.4 16.5 18.6 18.6 18.6 18.7 21.1 21.1 21.1 21.2
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
15
Expanded Cooling Data — GLXS3BN6010A+ CAPTA6030A
16
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 56.7 57.5 59.2 – 56.2 57.0 58.7 – 54.7 55.5 57.2 – 52.2 53.0 54.7 – 49.1 49.9 51.6 – 46.3 47.1 48.8 –
S/T 0.60 0.53 0.41 – 0.60 0.53 0.41 – 0.62 0.56 0.43 – 0.64 0.57 0.45 – 0.66 0.59 0.47 – 1.00 0.64 0.52 –
1490 T 22 20 16
–
22 19 16
–
22 20 16
–
22 19 15
–
21 19 15
–
23 21 17
–
kW 3.59 3.59 3.58 – 4.03 4.03 4.02 – 4.52 4.52 4.51 – 5.05 5.05 5.04 – 5.64 5.64 5.63 – 6.34 6.33 6.33 –
Amps 13.4 13.4 13.4 – 15.4 15.4 15.4 – 17.7 17.6 17.6 – 20.1 20.1 20.0 – 22.8 22.8 22.7 – 26.0 26.0 25.9 –
MBh 59.5 60.3 62.0 – 59.0 59.8 61.5 – 57.6 58.4 60.0 – 55.1 55.9 57.5 – 52.0 52.8 54.5 – 49.2 50.0 51.7 –
S/T 0.63 0.56 0.44 – 0.64 0.57 0.45 – 0.66 0.59 0.47 – 0.68 0.61 0.49 – 1.00 0.63 0.51 – 1.00 0.67 0.55 –
70 2000 T 19 17 13
–
19 17 13
–
19 17 13
–
19 17 13
–
19 16 13
–
20 18 14
–
kW 3.64 3.64 3.63 – 4.08 4.08 4.07 – 4.57 4.57 4.56 – 5.10 5.09 5.09 – 5.69 5.69 5.68 – 6.38 6.38 6.37 –
Amps 13.6 13.6 13.6 – 15.6 15.6 15.6 – 17.9 17.9 17.8 – 20.3 20.3 20.3 – 23.0 23.0 23.0 – 26.2 26.2 26.1 –
MBh 61.5 62.3 64.0 – 61.0 61.8 63.5 – 59.6 60.4 62.0 – 57.0 57.8 59.5 – 54.0 54.8 56.4 – 51.2 52.0 53.6 –
S/T 0.60 0.53 0.41 – 0.60 0.54 0.41 – 0.63 0.56 0.44 – 1.00 0.58 0.45 – 1.00 0.60 0.47 – 1.00 0.64 0.52 –
2250 T 18 16 12
–
18 16 12
–
18 16 12
–
18 16 12
–
17 15 11
–
19 17 13
–
kW 3.66 3.66 3.65 – 4.10 4.10 4.09 – 4.59 4.59 4.58 – 5.12 5.12 5.11 – 5.71 5.71 5.70 – 6.40 6.40 6.39 –
Amps 13.7 13.7 13.7 – 15.7 15.7 15.7 – 18.0 18.0 17.9 – 20.4 20.4 20.3 – 23.1 23.1 23.1 – 26.3 26.3 26.2 –
www.goodmanmfg.com
MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.8 55.6 57.2 59.8 52.2 53.0 54.7 57.3 49.2 50.0 51.6 54.2 46.4 47.2 48.8 51.4
S/T 0.71 0.64 0.52 0.4 0.72 0.65 0.53 0.4 0.74 0.67 0.55 0.4 1.00 0.69 0.57 0.4 1.00 0.71 0.59 0.5 1.00 0.75 0.63 0.5
1490 T 26 24 20 16 26 24 20 16 27 24 20 16 26 24 20 16 26 24 20 16 27 25 21 17
kW 3.59 3.59 3.58 3.6 4.03 4.03 4.02 4.1 4.52 4.52 4.51 4.5 5.05 5.04 5.04 5.1 5.64 5.64 5.63 5.7 6.33 6.33 6.32 6.4
Amps 13.4 13.4 13.4 13.5 15.4 15.4 15.4 15.5 17.7 17.6 17.6 17.8 20.1 20.1 20.0 20.2 22.8 22.8 22.7 22.9 26.0 25.9 25.9 26.1
MBh 59.6 60.4 62.0 64.6 59.1 59.9 61.5 64.1 57.6 58.4 60.1 62.6 55.1 55.9 57.6 60.1 52.0 52.8 54.5 57.0 49.2 50.0 51.7 54.2
S/T 0.75 0.68 0.56 0.4 0.75 0.68 0.56 0.4 1.00 0.71 0.59 0.5 1.00 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 1.00 0.67 0.5
75 2000 T 24 22 18 13 24 21 17 13 24 22 18 14 24 21 17 13 23 21 17 13 25 22 19 14
kW 3.64 3.64 3.63 3.66 4.08 4.07 4.07 4.10 4.57 4.56 4.56 4.59 5.10 5.09 5.08 5.12 5.69 5.68 5.68 5.71 6.38 6.38 6.37 6.40
Amps 13.6 13.6 13.6 13.7 15.6 15.6 15.6 15.7 17.9 17.9 17.8 18.0 20.3 20.3 20.2 20.4 23.0 23.0 22.9 23.1 26.2 26.2 26.1 26.3
MBh 61.6 62.3 64.0 66.6 61.1 61.8 63.5 66.1 59.6 60.4 62.1 64.6 57.1 57.9 59.5 62.1 54.0 54.8 56.5 59.0 51.2 52.0 53.7 56.2
S/T 0.71 0.65 0.52 0.4 1.00 0.65 0.53 0.4 1.00 0.67 0.55 0.4 1.00 0.69 0.57 0.4 1.00 0.71 0.59 0.5 1.00 1.00 0.64 0.5
2250 T 22 20 16 12 22 20 16 12 23 21 17 13 22 20 16 12 22 20 16 12 23 21 17 13
kW 3.66 3.66 3.65 3.7 4.10 4.09 4.09 4.1 4.59 4.58 4.58 4.6 5.12 5.11 5.10 5.1 5.71 5.70 5.70 5.7 6.40 6.40 6.39 6.4
Amps 13.7 13.7 13.7 13.8 15.7 15.7 15.7 15.8 18.0 17.9 17.9 18.1 20.4 20.4 20.3 20.5 23.1 23.1 23.0 23.2 26.3 26.2 26.2 26.4
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects ACCA (TVA) conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
SS-GLXS3B-R32
SS-GLXS3B-R32
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.5 49.1 51.7
S/T 0.82 0.76 0.63 0.5 1.00 0.76 0.64 0.5 1.00 0.78 0.66 0.5 1.00 0.80 0.68 0.6 1.00 0.82 0.70 0.6 1.00 1.00 0.75 0.6
1490 T 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 20 32 30 26 22 kW 3.59 3.59 3.58 3.6 4.03 4.03 4.02 4.1 4.52 4.52 4.51 4.5 5.05 5.05 5.04 5.1 5.64 5.64 5.63 5.7 6.34 6.33 6.32 6.4
Amps 13.4 13.4 13.4 13.5 15.4 15.4 15.4 15.5 17.7 17.6 17.6 17.8 20.1 20.1 20.0 20.2 22.8 22.8 22.7 22.9 26.0 26.0 25.9 26.1
MBh 59.9 60.7 62.3 64.9 59.4 60.2 61.8 64.4 57.9 58.7 60.4 62.9 55.4 56.2 57.9 60.4 52.3 53.1 54.8 57.3 49.5 50.3 52.0 54.5
S/T 1.00 0.79 0.67 0.5 1.00 0.80 0.68 0.5 1.00 0.82 0.70 0.6 1.00 0.84 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.78 0.7
80 2000 T 28 26 22 18 28 26 22 18 29 26 22 18 28 26 22 18 28 26 22 18 29 27 23 19 kW 3.64 3.64 3.63 3.66 4.08 4.08 4.07 4.10 4.57 4.57 4.56 4.59 5.10 5.09 5.09 5.12 5.69 5.69 5.68 5.71 6.38 6.38 6.37 6.41
Amps 13.6 13.6 13.6 13.7 15.6 15.6 15.6 15.7 17.9 17.9 17.8 18.0 20.3 20.3 20.3 20.4 23.0 23.0 23.0 23.1 26.2 26.2 26.1 26.3
MBh 61.8 62.6 64.3 66.9 61.3 62.1 63.8 66.4 59.9 60.7 62.3 64.9 57.4 58.2 59.8 62.4 54.3 55.1 56.8 59.3 51.5 52.3 54.0 56.5
S/T 1.00 0.76 0.64 0.5 1.00 0.76 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.68 0.6 1.00 1.00 0.70 0.6 1.00 1.00 0.75 0.6
2250 T 27 25 21 17 27 25 21 17 27 25 21 17 27 25 21 17 27 25 21 17 28 26 22 18
kW 3.66 3.66 3.65 3.7 4.10 4.10 4.09 4.1 4.59 4.59 4.58 4.6 5.12 5.11 5.11 5.1 5.71 5.71 5.70 5.7 6.40 6.40 6.39 6.4
Amps 13.7 13.7 13.7 13.8 15.7 15.7 15.7 15.8 18.0 18.0 17.9 18.1 20.4 20.4 20.3 20.5 23.1 23.1 23.0 23.2 26.3 26.3 26.2 26.4
Expanded Cooling Data — GLXS3BN6010A+ CAPTA6030A (cont.)
www.goodmanmfg.com
MBh 58.0 58.7 60.4 63.0 57.5 58.2 59.9 62.5 56.0 56.8 58.5 61.0 53.5 54.3 55.9 58.5 50.4 51.2 52.9 55.4 47.6 48.4 50.1 52.6
S/T 1.00 0.85 0.72 0.6 1.00 0.85 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.84 0.7
1490 T 35 33 29 25 35 33 29 25 35 33 29 25 35 33 29 25 35 33 29 25 36 34 30 26
kW 3.60 3.60 3.59 3.6 4.04 4.04 4.03 4.1 4.53 4.53 4.52 4.6 5.06 5.06 5.05 5.1 5.65 5.65 5.64 5.7 6.34 6.34 6.33 6.4
Amps 13.5 13.4 13.4 13.6 15.5 15.4 15.4 15.6 17.7 17.7 17.7 17.8 20.1 20.1 20.1 20.2 22.8 22.8 22.8 22.9 26.0 26.0 26.0 26.1
MBh 60.8 61.6 63.3 65.8 60.3 61.1 62.8 65.3 58.9 59.6 61.3 63.9 56.3 57.1 58.8 61.4 53.3 54.1 55.7 58.3 50.5 51.2 52.9 55.5
S/T 1.00 0.88 0.76 0.6 1.00 0.89 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 1.00 0.7
85 2000 T 32 30 26 22 32 30 26 22 33 31 27 23 32 30 26 22 32 30 26 22 33 31 27 23
kW 3.65 3.65 3.64 3.67 4.09 4.08 4.08 4.11 4.58 4.57 4.57 4.60 5.11 5.10 5.10 5.13 5.70 5.69 5.69 5.72 6.39 6.39 6.38 6.41
Amps 13.7 13.7 13.6 13.8 15.7 15.7 15.6 15.8 17.9 17.9 17.9 18.0 20.3 20.3 20.3 20.4 23.0 23.0 23.0 23.1 26.2 26.2 26.2 26.3
MBh 62.8 63.6 65.3 67.8 62.3 63.1 64.8 67.3 60.8 61.6 63.3 65.8 58.3 59.1 60.8 63.3 55.2 56.0 57.7 60.3 52.4 53.2 54.9 57.5
S/T 1.00 0.85 0.73 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.77 0.6 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.7
2250 T 31 29 25 21 31 29 25 21 32 29 25 21 31 29 25 21 31 29 25 21 32 30 26 22
kW 3.67 3.67 3.66 3.7 4.11 4.10 4.10 4.1 4.60 4.59 4.59 4.6 5.13 5.12 5.12 5.1 5.72 5.71 5.71 5.7 6.41 6.41 6.40 6.4
Amps 13.8 13.8 13.7 13.9 15.8 15.8 15.7 15.9 18.0 18.0 18.0 18.1 20.4 20.4 20.4 20.5 23.1 23.1 23.1 23.2 26.3 26.3 26.3 26.4
IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves.
Shaded area reflects AHRI conditions
kW = Total system power Amps = outdoor unit amps (comp.+fan)
17
Performance Data
GLXS3BN1810/CAPTA2422
Conditions: 80 °F IBD, 67 °F IWB @ 625 CFM
Outdoor
Total
Sensible
Latent
Total
Tem. ° F.
BTU/h
BTU/h
BTU/h
Watts
75
19,300
12,540
6,760
1,320
80
19,060
12,600
6,460
1,390
85
18,820
12,660
6,160
1,460
90
18,410
12,540
5,870
1,540
95
18,000
12,420
5,580
1,620
100
17,495
12,245
5,250
1,705
105
16,990
12,070
4,920
1,790
110
16,535
12,120
4,415
1,890
115
16,080
12,170
3,910
1,990
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
17,360
12,140
5,220
1,620
GLXS3BN3010/CAPTA3026
Conditions: 80 °F IBD, 67 °F IWB @ 950 CFM
Outdoor
Total
Sensible
Latent
Total
Tem. ° F.
BTU/h
BTU/h
BTU/h
Watts
75
30,670
21,380
9,290
2,050
80
30,290
21,480
8,810
2,175
85
29,910
21,580
8,330
2,300
90
29,255
21,380
7,875
2,435
95
28,600
21,180
7,420
2,570
100
27,800
20,880
6,920
2,725
105
27,000
20,580
6,420
2,880
110
26,270
20,665
5,605
3,060
115
25,540
20,750
4,790
3,240
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
27,580
20,700
6,880
2,580
GLXS3BN2410/CAPTA2422
Conditions: 80 °F IBD, 67 °F IWB @ 700 CFM
Outdoor
Total
Sensible
Latent
Tem. ° F.
BTU/h
BTU/h
BTU/h
75
24,660
16,720
7,940
80
24,355
16,800
7,555
85
24,050
16,880
7,170
90
23,525
16,725
6,800
95
23,000
16,570
6,430
100
22,360
16,335
6,025
105
21,720
16,100
5,620
110
21,130
16,165
4,965
115
20,540
16,230
4,310
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
22,180
16,190
5,990
Total Watts 1,670 1,765 1,860 1,965 2,070 2,185 2,300 2,435 2,570
2,070
GLXS3BN3610/CAPTA3626
Conditions: 80 °F IBD, 67 °F IWB @ 1150 CFM
Outdoor
Total
Sensible
Latent
Total
Tem. ° F.
BTU/h
BTU/h
BTU/h
Watts
75
36,670
26,290
10,380
2,460
80
36,215
26,415
9,800
2,610
85
35,760
26,540
9,220
2,760
90
34,980
26,295
8,685
2,920
95
34,200
26,050
8,150
3,080
100
33,245
25,680
7,565
3,260
105
32,290
25,310
6,980
3,440
110
31,420
27,930
3,490
3,645
115
30,550
30,550
0
3,850
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
32,980
25,450
7,530
3,080
18
www.goodmanmfg.com
SS-GLXS3B-R32
GLXS3BN4210/CAPTA4230
Conditions: 80 °F IBD, 67 °F IWB @ 1365 CFM
Outdoor
Total
Sensible
Latent
Total
Tem. ° F.
BTU/h
BTU/h
BTU/h
Watts
75
42,350
30,250
12,100
2,900
80
41,830
30,390
11,440
3,055
85
41,310
30,530
10,780
3,210
90
40,405
30,245
10,160
3,380
95
39,500
29,960
9,540
3,550
100
38,395
29,535
8,860
3,740
105
37,290
29,110
8,180
3,930
110
36,285
29,235
7,050
4,155
115
35,280
29,360
5,920
4,380
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
38,090
29,280
8,810
3,560
GLXS3BN6010/CAPTA6030
Conditions: 80 °F IBD, 67 °F IWB @ 1490 CFM
Outdoor Tem. ° F.
75
Total BTU/h 58,970
Sensible BTU/h 37,730
Latent BTU/h 21,240
Total Watts 4,020
80
58,240
37,905
20,335
4,265
85
57,510
38,080
19,430
4,510
90
56,255
37,730
18,525
4,775
95
55,000
37,380
17,620
5,040
100
53,465
36,850
16,615
5,335
105
51,930
36,320
15,610
5,630
110
50,525
36,470
14,055
5,975
115
49,120
36,620
12,500
6,320
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
53,040
36,530
16,510
5,040
Performance Data
GLXS3BN4810/CAPT6030
Conditions: 80 °F IBD, 67 °F IWB @ 1400 CFM
Outdoor
Total
Sensible
Latent
Total
Tem. ° F.
BTU/h
BTU/h
BTU/h
Watts
75
48,790
33,330
15,460
3,360
80
48,185
33,490
14,695
3,555
85
47,580
33,650
13,930
3,750
90
46,540
33,335
13,205
3,960
95
45,500
33,020
12,480
4,170
100
44,230
32,550
11,680
4,400
105
42,960
32,080
10,880
4,630
110
41,800
32,215
9,585
4,905
115
40,640
32,350
8,290
5,180
TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB
95°
43,880
32,270
11,610
4,170
NOTE: no factory installed crankcase heater
SS-GLXS3B-R32
www.goodmanmfg.com
19
Dimensions
W H
Model
Dimensions
W”
D”
H”
GLXS3BN1810A GLXS3BN2410A
GLXS3BN3010A
GLXS3BN3610A GLXS3BN4210A GLXS3BN4810A GLXS3BN6010A*
26
26
27½
26
26
27½
26
26
32½
26
26
32½
29
29
35¾
29
29
39½
35½
35½
39½
*Note: All the Dimensions (W, D, H) are for reference only.
D
20
www.goodmanmfg.com
SS-GLXS3B-R32
SS-GLXS3B-R32
Wiring Diagram — GLXS3BN1810A, GLXS3BN2410A, GLXS3BN3010A*
www.goodmanmfg.com
CONTROL BOX BL/PK
LVJB
BL/PK BL
Y
SEE NOTE 1
C
SEE NOTE 3
BK
SR
5
1
2
RD
YL
T1 T2 L1 L2
ALTERNATE DOUBLE POLE CONTACTOR
MAIN PU
AUX BR
IO BK
CM
SC
BL
BK
RD BK BK
RD
RD
T1 T2 RD RD
L1 L2 C
COLOR CODE
BK ————— BLACK BL ————— BLUE BL/PK ———- BLUE/PINK STRIPE BR ————— BROWN OR
————— ORANGE PU ————— PURPLE RD ————— RED WH ————– WHITE YL —————- YELLOW
BL/PK BL/PK
RD
PU C
RD BR
YL
HERM F
RCCF
YL YL
YL
SA (IF USED) NOTE 2
RD
WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE
RD BK
YL IO
COMP MAIN
AUX
C
S
R
EQUIPMENT GROUND SEE NOTE 3
HPS
COMPONENT CODE C ————— CONTACTOR CM ———— OUTDOOR FAN MOTOR COMP ——– COMPRESSOR
HPS ———– HIGH PRESSURE SWITCH IO ————– INTERNAL OVERLOAD LVJB ———- LOW VOLTAGE
JUNCTION BOX RCCF ——— RUN CAPACITOR FOR COMPRESSOR & FAN SA ————- START ASSIST
SC ————- START CAPACITOR FOR COMPRESSOR SR ————- START RELAY FOR COMPRESSOR
CONTROLS SHOWN WITH THERMOSTAT IN ‘OFF’ POSITION.
OUTDOOR POWER SUPPLY SEE RATING PLATE SEE NOTE 3
T1 L1
IO C
5 SR 2
AUX
S
COMP
MAIN
R
1 SC
H
C
RCCF
F
T2 L2
C
IO AUX CM MAIN
SA (IF USED)
ALTERNATE DOUBLE POLE CONTACTOR ONLY
C HPS
Y
C
SEE NOTE 1
SEE NOTE 3
NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND
INDOOR THERMOSTAT.USE N.E.C. CLASS 2 WIRE. 2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY.
0140R00617-A
Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.
WARNING
High Voltage: Disconnect all power before servicing or installing this unit.
Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury, or death.
21
Wiring Diagram — GLXS3BN3610A, GLXS3BN4210A, GLXS3BN4810A, GLXS3BN6010A
22
www.goodmanmfg.com
CONTROL BOX
BK SR 5
1
2
RD
YL
T1 T2 L1 L2
ALTERNATE DOUBLE POLE CONTACTOR
MAIN PU
AUX BR
IO BK
CM
BL/PK BL
Y SEE NOTE 1 C SEE NOTE 3
SC
LVJB
BL BL/PK
BK BK BK RD
T2 RD T1
RD L1 L2
C
RD RD
BL/PK BL/PK
RD
YL
PU
C HERM
YL
RD BR
F YL YL
RCCF
SA (IF USED) NOTE 2
RD
COLOR CODE BK————- BLACK BL————- BLUE BL/PK——– BLUE/PINK STRIPE BR————- BROW N
OR———— ORANGE PU————- PURPLE RD————-RED W H———— W HITE YL————- YELLOW
WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE
SWITCH (PRESS.) SWITCH (TEMP)
ALTERNATE DOUBLE POLE CONTACTOR ONLY
AUX AUX
OUTDOOR POWER SUPPLY SEE RATING PLATE SEE NOTE 3
T1 L1
5 SR 2
H
C T2
1 SC
L2 C
IO C
S
COMP
MAIN
R
H
C
RCCF
F
IO CM MAIN
C
SA (IF USED)
HPS
RD BK
COMP MAIN
AUX
YL
IO
C
S
R
EQUIPMENT GROUND SEE NOTE 3
HPS
COMPONENT CODE C ————– CONTACTOR CM ———— OUTDOOR FAN MOTOR COMP ——- COMPRESSOR
HPS ———- HIGH PRESSURE SWITCH IO ————- INTERNAL OVERLOAD LVJB ——— LOW VOLTAGE
JUNCTION BOX RCCF ——– RUN CAPACITOR FOR COMPRESSOR & FAN SA ———— START ASSIST
SC ———— START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ———— START RELAY FOR
COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN ‘OFF’ POSITION.
Y
C
SEE NOTE 1
SEE NOTE 3
NOTES:
- TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT. USE N.E.C. CLASS 2 WIRE.
- START ASSIST FACTORY EQUIPPED WHEN REQUIRED.
- USE COPPER CONDUCTORS ONLY.
0140R00603-B
SS-GLXS3B-R32
Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.
WARNING
High Voltage: Disconnect all power before servicing or installing this unit.
Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury, or death.
Model
Description
0161R00128
Neutral Circular Cap
ABK-20
Anchor Bracket Kit ^
ASC01A
Anti-Short Cycle Kit
Factory Installed Hard Start Kit
CSR-U-1
Hard-start Kit
CSR-U-2
Hard-start Kit
CSR-U-3
Hard-start Kit
FSK01A¹
Freeze Protection Kit
LSK02A²
Liquid Line Solenoid Kit
LAKT01
Low-Ambient Kit
0130R00000S Low-Pressure Switch Kit
GLXS3BN GLXS3BN GLXS3BN GLXS3BN GLXS3BN GLXS3BN4 GLXS3BN 1810A 2410A 3010A 3610A 4210A 810A 6010A*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
^ Contains 20 brackets; four brackets needed to anchor unit to pad
¹ Installed on indoor coil
2 Condensing units and heat pumps with reciprocating or rotary compressors
require the use of start-assist components when used in conjunction with an
indoor coil using a non-bleed thermal expansion valve refrigerant metering
device or liquid line solenoid kit. The TXV should always be sized based on
the tonnage of the outdoor unit.
Accessories
All AHRI system ratings are accessible in the System Configurator tool via PartnerLink.
SS-GLXS3B-R32
www.goodmanmfg.com
23
Notes
Our continuing commitment to quality products may mean a change in specifications without notice.
©2024
· Houston, Texas · Printed in the USA.
24
www.goodmanmfg.com
SS-GLXS3B-R32
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>