iGuzzini MJ50 Initial Module Owner’s Manual
- September 15, 2024
- iGuzzini
Table of Contents
iN30
Design iGuzzini iGuzzini
Last information update: September 2024
Product configuration: MJ50
MJ50: initial module L 1197 – Low Contrast – direct emission – LED – warm white integrated DALI dimmable control gear
Product code
MJ50: initial module L 1197 – Low Contrast – direct emission – LED – warm white integrated DALI dimmable control gear
Technical description
direct emission modular lighting system with LED lamps. Initial module for general lighting (Low Contrast); can be used independently or in a continuous line. Minimal (frameless) version extruded aluminium single length profile; methacrylate opal screen set up for connection to end caps on both sides. Installation can be recessed, surface-mounted (ceiling/wall), or pendant. The module must be completed with the accessories kit needed for the selected type of installation. DALI dimmable electronic control gear integrated in the luminaire. Warm white high efficiency LED.
Installation
pendant: complete with power supply unit with cable (MWG5) and suspension cables (MWG6); surface-mounted: complete with supports (MWG7); recessed: after making the preparation slot, use the special supports to install in the false ceiling (MWG8).
Colour
White (01) | Black (04) | Aluminium (12)
Weight (Kg)
2.1
Mounting
ceiling recessed|ceiling surface|ceiling pendant
Wiring
the module is fitted with 5-pin terminal blocks for pass-through wiring at the ends; the accessory power supply unit code MWG5 has a fixing plate with 5-pin terminal block for connection to the main power supply. DALI dimmable control gear integrated in the module.
Notes
initial modules may be completed with accessory end caps (MX80) and used
independently in the various applications. To make continuous lines of
lighting, use the intermediate modules. To correctly complete a continuous
line, always use an initial module at the start or end of the structure.
Complies with EN60598-1 and pertinent regulations
Technical data
lm system: | 1879 |
---|---|
W system: | 19 |
lm source: | 2450 |
W source: | 16 |
Luminous efficiency (lm/W, real value): | 98.9 |
lm in emergency mode: | – |
Total light flux at or above an angle of 90° [Lm]: | 0 |
Light Output Ratio (L.O.R.) [%]: | 77 |
CRI (minimum): | 80 |
Colour temperature [K]: | 3000 |
MacAdam Step: | 3 |
Life Time LED 1: | 50,000h – L80 – B10 (Ta 25°C) |
Lamp code: | LED |
Number of lamps for optical assembly: | 1 |
ZVEI Code: | LED |
Number of optical assemblies: | 1 |
Power factor: | See installation instructions |
Inrush current: | 13.6 A / 304 µs |
Overvoltage protection: | 2kV Common mode & 1kV Differential mode |
Control: | DALI-2 |
Polar
Utilisation factors
Luminance curve limit