PLANET ICA-x80 series H.265 PoE IP Camera Installation Guide

September 12, 2024
PLANET

ICA-x80 series H.265 PoE IP Camera

“`html

Specifications

  • Models: ICA-3280, ICA-4280, ICA-3480, ICA-4480, ICA-3480F,
    ICA-4480F, ICA-M3580P, ICA-M4580P

  • Resolution: 1080p to 5 Mega-pixel

  • Compression: H.265 and H.265+

  • Features: Smart IR, Full Color, Remote Focus and Zoom

  • Power: IEEE 802.3af/at PoE or AC to DC adapter

Product Usage Instructions

1. Package Contents

Unbox the ICA-x80 series and ensure you have the following
items:

  • IP Camera x 1
  • Quick Start QR Code Sheet x 1
  • Screw Package x 1
  • Waterproof Connector Package x 1
  • Drill Template x 1

If any item is missing or damaged, contact your local reseller
for a replacement.

2. Requirements

For optimal access, use Chrome to configure the ICA-x80 series.
Disable anti-virus software or firewall if web interface is not
accessible.

3. Starting Web Management

Configure the ICA-x80 series through Ethernet:

  1. Power the device using AC to DC adapter or IEEE 802.3af/at PoE
    switch.

  2. The default network type is DHCP Client. Use PLANET Search
    Tools utility to find the IP address.

  3. If no DHCP server, default IP address is 192.168.0.20. Set
    manager PC to 192.168.0.x with subnet mask 255.255.255.0.

4. Logging in to the ICA-x80 Series

Access the device using the default credentials:

  • Default IP Address: DHCP client, fallback IP address
    192.168.0.20

  • Default Username: admin

  • Default Password: admin

FAQ

Q: What should I do if I can’t access the Web interface?

A: Try using Chrome and disable anti-virus software or
firewall.

Q: What is the default IP address of the ICA-x80 series?

A: The default IP address is 192.168.0.20 if DHCP is not
available.

Q: How do I find the current IP address of the camera?

A: Use the PLANET Search Tools utility provided on the PLANET
website.

“`

Quick Installation Guide
H.265 PoE IP Camera ICA-x80 series
Quick Installation Guide
1

Quick Installation Guide
Table of Contents
TABLE OF CONTENTS ………………………………………………………..2 1. INTRODUCTION ………………………………………………………………3 2. PACKAGE CONTENTS …………………………………………………….4 3. REQUIREMENTS……………………………………………………………..4 4. STARTING WEB MANAGEMENT………………………………………5 4.1 LOGGING IN TO THE ICA-X80 SERIES……………………………7 5. RECOVERING BACK TO DEFAULT CONFIGURATION ……. 11 CUSTOMER SUPPORT………………………………………………………13

– 2 –

PLANET Technology Corp.2024 ©

Quick Installation Guide

1. Introduction
Thank you for purchasing PLANET H.265 PoE IP Camera. The “ICA-x80 series” is used for all the models described below in this Quick Installation Guide.

ICA-3280

H.265 1080p Smart IR Bullet IP Camera

ICA-4280

H.265 1080p Smart IR Dome IP Camera

ICA-3480

H.265+ 4MP Smart IR Bullet IP Camera

ICA-4480

H.265+ 4MP Smart IR Dome IP Camera

ICA-3480F H.265+ 4MP Full Color Bullet IP Camera

ICA-4480F H.265+ 4MP Full Color Dome IP Camera

ICA-M3580P

H.265 5 Mega-pixel Smart IR Bullet IP Camera with Remote Focus and Zoom

ICA-M4580P

H.265 5 Mega-pixel Smart IR Dome IP Camera with Remote Focus and Zoom

– 3 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
2. Package Contents
Open the box of the ICA-x80 series and carefully unpack it. The box should contain the following items:
The IP Camera x 1 Quick Start QR Code Sheet x 1 Screw Package x 1 Waterproof Connector Package x 1 Drill Template x 1
If any item is found missing or damaged, please contact your local reseller for replacement.
3. Requirements
· Workstations running Windows 10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
· Workstations are installed with Ethernet NIC (Network Interface Card).
· One IEEE 802.3af/at PoE switch (Supply power to the ICA-x80 series)
· Ethernet Port Connection Network cables — Use standard network (UTP) cables with RJ45 connectors. The above PC is installed with Web browser.

Note:

It is recommended to use Chrome to access the ICA-x80 series. If the Web interface of the ICA-x80 series is not accessible, please turn off the anti- virus software or firewall and then try it again.

– 4 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
4. Starting Web Management
The following shows how to start up the Web Management of the ICA-x80 series. Note the ICA-x80 series is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
Figure 4-1: IP Management Diagram
1. The ICA-x80 series supports IEEE 802.3af/at standard; be reminded to power either from AC to DC adapter or 802.3af/at PoE switch.
2. The AC to DC adapter is not included in the package.
For example, the ICA-x80 series’ default network type is DHCP Client. To search the current IP address of the ICA-x80 series, follow the procedure below: 1. Download the “PLANET Search Tools” utility from the following PLANET website
link: http://www.planet.com.tw/en/support/downloads?method=keyword&keyword=PLANE T+Search+Tools&view=6#list 2. Install the “PLANET Search Tools” utility. 3. After the camera utility is launched, all cameras found in your local area network will be displayed. 4. The existing ICA-x80 series in the local network. 5. Search the ICA-x80 series in the network. 6. Modify the IP parameters of the selected ICA-x80 series. 7. Select the ICA-x80 series you want to configure and double-click on it. 8. You will be connected to the ICA-x80 series via web browser automatically.

– 5 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
Figure 4-2: PLANET Search Tools Utility Screen 9. Without DHCP server, the ICA-x80 series’ default IP address is 192.168.0.20, then
the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 20), and the default subnet mask is 255.255.255.0.

– 6 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
4.1 Logging in to the ICA-x80 Series
1. When the following dialog box appears, please enter the default user name and password “admin”. The login screen in Figure 4-3 appears.
Default IP Address: DHCP client, fallback IP address 192.168.0.20 Default Username: admin Default Password: admin

Figure 4-3: ICA-x80 series Web Login Screen

1. The following web screen based on the ICA-3480F will be the same as that of the ICA-x80 series.
2. The following steps is based on the firmware version before August of 2024.
2. After entering the username and password, the main screen appears as Figure 4-4 and Figure 4-5 show.

– 7 –

PLANET Technology Corp.2024 ©

Quick Installation Guide Figure 4-4: Web Main Screen of the ICA-x80 series

Figure 4-5: Web Main Screen of the ICA-Mx580P series

Figure 4-5 is based on the ICA-M3580P and ICA-M4580P only.

Now, you can use the Web management interface to continue the ICA-x80 series’

management. Please refer to the user’s manual for more.

– 8 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
The following web screen is based on the firmware version of August of 2024 or after.
3. After entering the username and password, the main screen appears as Figure 4-6-1 shows. You will be required to change the password. The length of the password should be at least 8 to 31 digits with two or more combinations of numerals, and lowercase and uppercase letters, and special characters (~!@#$%^&*-_+=|;:,./?). You also need to set a Security Question and Answer, and perform an Export Key to avoid forgetting the password in the future. Please create a new password and log in again.

Figure 4-6-1: Modify User Screen of ICA-Mx580P series

– 9 –

PLANET Technology Corp.2024 ©

Quick Installation Guide

Figure 4-6-2: Modify User Screen of ICA-Mx580P series
If you have already changed the password via console or web login, please use this new password to log in and skip step 3.

– 10 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
5. Recovering Back to Default Configuration
IP Address has been changed or admin password has been forgotten To reset the network type to the default “DHCP Client” with IP address “192.168.0.20” or reset the login password to default value, press the hardware-based reset button for about 10 seconds. After the ICA-x80 series is rebooted, you can log in the management Web interface within the factory default mode.
Reset
Figure 5-1: Reset Button
For ICA-3280, ICA-4280, ICA-3480, ICA-4480, ICA-3480F Note: and ICA-4480F only.

– 11 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
Micro SD card slot Reset
Figure 5-2: Reset Button and Micro SD Card Slot of ICA-M3580P

Micro SD card slot Reset

Figure 5-3: Reset Button and Micro SD Card Slot of ICA-M4580P Note: Only the ICA-M3580P and ICA-M4580P have the SD card slot.

– 12 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource and user’s manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq?method=category&c1=8
Support team mail address: support@planet.com.tw
ICA-x80 Series User’s Manual: https://www.planet.com.tw/en/support/downloads?&method=keyword&keywor d=ICA-x80+series&view=3#list

Android App

IOS App

Copyright PLANET Technology Corp. 2024. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

– 13 –

PLANET Technology Corp.2024 ©

Quick Installation Guide
PLANET Technology Corp.
10F., No. 96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Energy Saving Note of the Device
This power required device does not support Standby mode operation. For energy savings, please remove the DC plug or slide the hardware-based Power Switch to the OFF position to disconnect the device from the power circuit. Without removing the DC plug from or switching off the device, the device will still consume power from the power source. In view of Saving the Energy and reducing the unnecessary power consumption, it is strongly suggested to power off or to remove the DC plug from the device if this device is not intended to be active.
2011-AB8200-007

– 14 –

PLANET Technology Corp.2024 ©

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PLANET User Manuals

Related Manuals