citronic 154.075UK 7x40W COB LED RGBW PAR Light User Manual

September 6, 2024
citronic

154.075UK 7x40W COB LED RGBW PAR Light

“`html

Specifications:

  • Power Consumption: 40W per LED
  • Fuse Rating: Check manual for specifics
  • LED Power: 7 x 40W COB RGBW LEDs
  • Luminance:
    • Red: Check manual for specifics
    • Green: Check manual for specifics
    • Blue: Check manual for specifics
    • White: Check manual for specifics
    • RGBW: Check manual for specifics
  • Beam Angle: Check manual for specifics
  • DMX Channels: 6, 9, 21, 30 channels
  • Connections: DMX input and output
  • Dimensions: Check manual for specifics
  • Weight: Check manual for specifics

Product Usage Instructions:

Placement:

  1. Place the CosmoPAR on a stable surface.
  2. Avoid placing the unit in damp or wet environments to prevent
    damage.

Cleaning:

  1. Disconnect the mains power before cleaning.
  2. Use a soft, dry cloth to gently clean the unit’s exterior.

Side Panel Controls:

  1. DMX output
  2. DMX input
  3. Microphone
  4. LCD display
  5. Control panel
  6. Fuse
  7. Power output (twist and lock)
  8. Power input (twist and lock)

Manual Control Menu:

To access the settings menu:

  • Press the MENU button.
  • Use the UP and DOWN buttons to navigate settings.
  • Press ENTER to save settings.

DMX Mode:

To control the CosmoPAR via DMX:

  • Connect the DMX source to the unit’s DMX input using a balanced
    XLR lead.

  • To add more fixtures, loop through the DMX out on the
    unit.

  • Select “Addr” from the menu to set the start address using UP
    and DOWN buttons, then ENTER to confirm.

  • The unit supports 6, 9, 21, or 30 DMX channels.

FAQ:

No Power (Mains):

Check mains lead and fuse. If fuse continually blows, contact
your dealer.

No Light Output:

Ensure the unit is charged and the power switch is on. Check
control panel mode settings.

Unresponsive to DMX:

Check DMX settings from the controller. Verify the unit is in
DMX mode and receiving a signal. Check DMX controller settings.

“`

CosmoPAR
7x40W COB LED RGBW PAR Light

Item ref: 154.075UK User Manual

Please read through this manual thoroughly before use, any damage Caused by misuse of product will not be covered by warranty.

A heavy-duty retro-style PAR light, fitted with 7 bright 40W RGBW COB LEDs that produce a vast array of eye-popping colours, patterns and effects. The unit can be controlled by auto, sound-to-light, master/slave programs or via 6/9/21/30 channel DMX if more precise control is required. Produces an amazing wall of brilliant colour when connected to multiple units, ideal for stage backgrounds and larger events.
In the box:
Your CosmoPAR should arrive with you in a single carton in good condition. The carton should contain 1 x main unit, 1 x UK twist and lock mains lead and 1 x user guide. Warning:
To prevent risk of fire or electric shock, do not expose the unit to rain or damp environments. In the event of a spillage, disconnect the mains and allow the unit to dry out naturally. Qualified personnel should then check the unit before continuing use.
Please do not open cover, contains high voltage. This product is not serviceable or repairable by the end user. Please refer to qualified personnel for service and repair.

www.avsl.com

154.075UK User Manual

Placement:
· Keep away from damp or dusty environments. · Ensure adequate airflow around the fixture housings. · Ensure adequate access to controls and connections.
Cleaning:
· Use a soft cloth with a neutral detergent to clean the casing as required. · Use a vacuum cleaner to clear ventilation grilles of any dust or debris build- ups. · Do not use strong solvents for cleaning the unit.

Side panel controls:

1. DMX output 2. DMX input 3. Microphone 4. LCD display

5. Control panel 6. Fuse 7. Power output (twist and lock) 8. Power input (twist and lock)

Manual control menu:

Press the “MENU” button to enter the settings menu. Press “UP” and “DOWN” buttons to navigate through various setting functions. Press “ENTER” button to save the desired setting.

www.avsl.com

154.075UK User Manual

DMX mode:
The CosmoPAR can be controlled by DMX signal, simply connect the DMX signal source to the DMX input on the unit via a balanced XLR lead. Extra fixtures can be controlled by the same DMX signal by looping through the DMX out on the unit. To enter DMX mode, select Addr from the menu and confirm the correct start address by using the “UP” and “DOWN” buttons and “ENTER” to confirm. This unit has 6, 9, 21 or 30 DMX channels as indicated in the table below:

www.avsl.com

154.075UK User Manual

6 Channel

9 Channel

www.avsl.com

154.075UK User Manual

21 Channels www.avsl.com

154.075UK User Manual

www.avsl.com

154.075UK User Manual

www.avsl.com

154.075UK User Manual

www.avsl.com

154.075UK User Manual

30 Channels

www.avsl.com

154.075UK User Manual

Specifications:
Power Power consumption Fuse rating LED power Luminance : red Luminance : green Luminance : blue Luminance : white Luminance : RGBW Beam angle DMX channels Connections Dimensions Weight Troubleshooting:
No power (mains)
No light output
Unresponsive to DMX
www.avsl.com

100 – 240Vac, 50/60Hz 260W F5A 7 x 40W COB RGBW LED 1429 @ 1m 1469 @ 1m 1872 @ 1m 1205 @ 1m 5820 @ 1m 40° 6, 9, 21 or 30CH Power in/out (twist and lock), DMX in/out (3pin XLR) 159 x 215 x 200mm 1.8kg
Check mains lead and fuse (if fuse continually blows, refer to your dealer) Check the unit is charged and the power switch is in the On position Check control panel mode settings Check DMX settings from controller (dimmer levels, blackout etc.) Check that unit is in DMX mode and ensure DMX address remains lit to confirm receiving DMX signal Check DMX controller is not set to black out Check DMX controller is on correct fixture/page
154.075UK User Manual

Overheating/cutting out

Check master dimmer value Check correct DMX address is set Check DMX connection and leads Ensure adequate ventilation and unit is not too close to a heat source

This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines.

Errors and omissions excepted. Copyright© 2024 AVSL Group Ltd, Unit 2 Bridgewater Park, Taylor Road, Trafford Park, Manchester. M41 7JQ.

AVSL (Europe) Ltd, Unit 3D North Point House, North Point Bus. Park, New Mallow Road, Cork, Ireland.

www.avsl.com

154.075UK User Manual

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals