Nureva HDL300 Sound Location Sata Enable Tracking for Lumens PTZ Cameras User Guide
- September 6, 2024
- nureva
Table of Contents
- HDL300 Sound Location Sata Enable Tracking for Lumens PTZ Cameras
- Specifications
- Product Usage Instructions
- 1. Hardware Connections
- 2. Install Nureva Console Client
- 3. Set up Nureva HDL300 Integration
- 4. Setup Camera Tracking Integration
- 5. Set Angle Positions
- Q: What cables are required for connecting the Nureva HDL300
- Q: What is the IP port used by the Nureva HDL300 device for
HDL300 Sound Location Sata Enable Tracking for Lumens PTZ Cameras
“`html
Specifications
- Product: Nureva HDL300
- Hardware Connections:
- Nureva HDL300 Microphone
- Cables: Cat5e, HDMI, USB 2.0
- HDL300 Connect Module
- CamConnect Processor (AI-BOX1)
- Display
- Meeting Room PC (Windows OS)
- Lumens PTZ Camera
Product Usage Instructions
1. Hardware Connections
Ensure all hardware components are connected as follows:
-
Connect Nureva HDL300 Microphone using the provided
cables. -
Connect HDL300 Connect Module to the CamConnect Processor and
Display. -
Connect Meeting Room PC to the Display.
-
Set up Lumens PTZ Camera for video integration.
2. Install Nureva Console Client
Follow these steps to install and set up the Nureva Console
client:
-
Download the Console Client from
here. -
Install the Console client and launch the app on your PC.
-
Connect the Nureva Connect Module to the PC using a USB
cable.
3. Set up Nureva HDL300 Integration
To integrate the Nureva HDL300 with the Console client:
- Pull down the vertical scroll bar in the Console client.
- Go to ‘Integrations’ and expand ‘Local Integrations’.
4. Setup Camera Tracking Integration
Follow these steps to set up camera tracking integration:
-
Enable ‘Network Integration Settings’.
-
Enter the Nureva device’s IP address and apply the
settings. -
Confirm that port 8931 is allowed to connect with your PC.
5. Set Angle Positions
To adjust the angle positions of the Nureva HDL300:
- The maximum Azimuth Angle range is -70 to +70 degrees.
- 0 degrees represents the center point.
- Refer to the diagram provided for sound source detection in the
0-degree region.
Frequently Asked Questions (FAQ)
Q: What cables are required for connecting the Nureva HDL300
Microphone?
A: The Nureva HDL300 Microphone requires Cat5e, HDMI, and USB
2.0 cables for connection.
Q: What is the IP port used by the Nureva HDL300 device for
integration?
A: The default port used by Nureva HDL300 is 8931. Please ensure
this port is permitted on your PC for connectivity.
“`
Nureva HDL300 Settings Guide
Nureva HDL300 1. Hardware Connections
Copyright © Lumens. All rights reserved.
1.1 Hardware Connections
Nureva HDL300 Microphone
Cable define Cat5e HDMI cable USB 2.0 cable
HDL300 connect module
CamConnect Processor (AI-BOX1)
Display
Meeting Room PC (Windows OS)
Display
Lumens PTZ Camera
Copyright © Lumens. All rights reserved.
Nureva HDL300 2. Install Nureva Console client
Copyright © Lumens. All rights reserved.
2.1 Install Nureva Console client
Download [Console Client] https://support.nureva.com/97341-download/win-mac-
download-
nureva-console-client
Copyright © Lumens. All rights reserved.
2.2 Set up Nureva Console client
Install Nureva Console client then launch the Console client app. Connect the
Nureva connect module to the PC with a USB cable.
Copyright © Lumens. All rights reserved.
2.3 Set up Nureva HDL300 integration
A
B C
A: Pull the vertical scroll bar of the Console client down B: Go to the
‘Integrations’ option and expand [Local integrations] Copyright © Lumens. All
rights reserved.
2.4 Setup camera tracking integration
A B
A: Enable [Network integration settings] B: Copy the IP address (C)
C
Copyright © Lumens. All rights reserved.
2.5 Setup camera tracking integration
A B
A: Enter the Nureva device’s IP
B: Press [Apply] and the toggle [connect] bar to enable Nureva’s default port
is 8931. Please confirm the port is permitted to connect with your PC.
Copyright © Lumens. All rights reserved.
3. Set angle positions
Copyright © Lumens. All rights reserved.
3.1 Set angle positions
70
-70
0
Note: The maximum “Azimuth Angle” range is -70 to +70 degrees. 0-degrees is
the center point. The diagram above shows a sound source detected in the
0-degree region.
Copyright © Lumens. All rights reserved.