Inovonics EN5061 Surface Mount Locator Instruction Manual
- September 6, 2024
- Inovonics
Table of Contents
EN5061 Surface Mount Locator
“`html
Specifications
-
Product Name: EN5061 Surface Mount Locator
-
Manufacturer: Inovonics
-
Website: www.inovonics.com
-
Power LED Indicator: Solid green when powered on
-
Installation Orientation: Arrow embossed on the inside of the
cover facing up if installed below 5 feet, and facing down if
installed above 5 feet -
Power Input: Power terminal pairs 1 and 2
-
Support: Inovonics technical services
Product Usage Instructions
Installation and Startup
2.1 Installation Notes
Ensure compliance with local building regulations and electrical
codes. Orient the unit correctly based on the installation height
as per the arrow embossed on the unit cover.
2.2 Install the EN5061 Surface Mount Locator
-
Mount the unit securely using the provided mounting
screws. -
Connect power cabling to either power terminal pair following
the provided diagram. -
If daisy-chaining power, use the second pair of screw terminals
for connecting to the next unit. -
Apply power to the unit.
-
Check that the power LED lights solid green to indicate
power.
FAQ
Q: Where can I find product and installation videos?
A: Visit www.inovonics.com/videos or use the QR code provided in
the manual.
Q: How should I orient the unit during installation?
A: Orient the unit with the arrow facing up if installed below 5
feet, and facing down if installed above 5 feet.
Q: What should I do if I encounter issues during
installation?
A: Contact Inovonics technical services for assistance and
training.
“`
EN5061 Surface Mount Locator Installation and Operation Manual 1 Overview
When deployed as part of an Inovonics mobile duress system, EN5061 surface
mount locators help determine the location of mobile duress pendants for
improved emergency response. When a mobile duress pendant is activated, the
alarm is sent through the Inovonics EchoStream system, and a Bluetooth®
message is simultaneously sent to any locators within range. Every locator
that hears the message then delivers the Bluetooth signal strength information
to the Inovonics mobile duress application, which determines location based on
the highest signal strength received, and distributes location notifications
per predefined user parameters.
1.1 Inovonics Contact Information
For product and installation videos visit us at www.inovonics.com/videos or
use the QR code below.
If you have any problems with this procedure, contact Inovonics technical
services:
· E-mail: support@inovonics.com. · Phone:
800-782-2709;
303-939-9336.
1.2 EN5061 Surface Mount Locator
2 Installation and Startup 2.1 Installation Notes
· These products are designed to be maintained by professional security
technicians from Inovonics factory-trained partners.
· Products are tested for indoor use. · All products should be manually tested
weekly.
2.2 Install the EN5061 Surface Mount Locator
NrDeoumrteeos:vsaSlUufrrsfoaemcr
eMpmaacnokuuaangltifnloogrcraaetnogdrissmtrmaotuuiosnnttibninegs.rteRrugecifsteitoernrteosd,tahwneidtIhncotohvneotansicicttesInpMoriovoborinlteoics
technical services if you require training.
Installation of the EN5061 requires a metal 4″ square, 2 1/8″ deep (or
greater) cut-in box be pre-installed in the wall. For EN5061 installation, the
box must have mounting screw-holes at diagonally opposite positions, with one
in the upper left and one in the lower right. Inovonics recommends the
Southwire 4″ square box, part number 52171-3/ 4-1, for new construction, and
the Southwire 4″ old work cut-in, part number 52181-OW, for retrofit
installations. Power cabling for either 12-24VAC 50/60 Hz or 12-24VDC must be
present and routed to the inside of the cut-in box, with stripped pigtails per
local electrical code. Each EN5061 consumes 670mW maximum. 1. Install the cut-
in box per manufacturer’s instructions and local building
and electrical codes.
Note: If installed five feet or lower on the wall, orient the unit with the
arrow embossed on the inside of the cover facing up; if installed above five
feet on the wall, orient the unit with the arrow facing down.
2. Connect power cabling to either power terminal pair.
B
A
Power terminal
–
pair 1
Power terminal
–
pair 2
B
Figure 1 EN5061 surface mount locator A Power LED B Mounting screws
Figure 2 Connect power cabling · If using DC power, make sure to connect
cabling to positive and negative, as indicated above the terminals.
Note: If you are planning to daisy chain the power, you can use the second
pair of screw terminals to attach to the power cable to the next unit.
3. Use the supplied tamper-resistant Torx 8-32-3/4″ flat head screws to mount
the EN5061 in the cut-in box. · Mount the EN5061 with the arrow embedded on
the back side of the cover pointing up. · Be careful not to overtighten screws
or flex cover.
4. Apply power. 5. Ensure the surface mount locator’s power LED lights solid
green.
6.26.23 357-00075-01 Rev A © Inovonics, 2023 – www.inovonics.com
3 Specifications
Faceplate: 5.50″ x 5.50″ x 1.01″ (139.7 mm X 139.7 mm X 25.7 mm). Weight: 4.8
oz. (136 g). Operating environment: 32 to 113°F (0 to 45°C), 90% relative
humidity, non-condensing. Power requirement: 12-24VAC 50/60 Hz or 12-24VDC 670
mW. Operating frequency: 902-928 MHz. Bluetooth frequency: 2.402 GHz to 2.480
GHz. Regulatory: FCC Part 15, Subpart C, RSS-247 Issue 2, RoHS Directive
2015/863. FCC ID: HCQBWA02. IC: 2309A-BWA02. HVIN: 00070-04.
Note: Inovonics supports recycling and reuse whenever possible. Please recycle
these parts using a certified electronics recycler.
4 Regulatory Compliance
4.1 Television and Radio Interference
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
· Increase the separation between the equipment and receiver. · Consult the
dealer or an experienced radio/TV technician for help. Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
4.2 FCC Part 15 and Innovation, Science and Economic Development Canada (ISED)
Compliance
This device complies with part 15 of the FCC Rules, and ISED licenseexempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference that may cause undesired operation of the device. Le présent
appareil est conforme aux CNR Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire
de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
4.3 Radiation Exposure Limits FCC
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. In order to avoid the possibility of exceeding the
FCC radio frequency exposure limits, human proximity to the antenna shall not
be less than 20 cm during normal operation and must not be co-located or
operating in conjunction with any other antenna or transmitter. ISED This
equipment complies with ISED RSS-102 radiation exposure limits set forth for
an uncontrolled environment. This transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter. Cet
équipement est conforme avec ISED RSS-102 des limites d’exposition aux
rayonnements définies pour un environnement non contrôlé. Cet émetteur doit
être installé à au moins 20 cm de toute personne et ne doit pas être
colocalisé ou fonctionner en association avec une autre antenne ou émetteur.
6.26.23 357-00075-01 Rev A © Inovonics, 2023 – www.inovonics.com
2
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>