purehaven 1600S Diode Laser Hair Removal Machine
Product Information
Specifications
- Model: DIOLASHEER ICE 1600S
- Operating Voltage: 220V (10A) or 110V (15A)
- Ambient Temperature: 10-30°C
- Relative Humidity: 75%
- Atmospheric Pressure: 860-1060hpa
Product Usage Instructions
- Operation Environment
1. Ambient temperature should be maintained between 10-30°C.
2. Relative humidity should be around 75%.
3. Atmospheric pressure should range from 860 to 1060hpa.
-
Electrical Safety
The machine operates at a rated voltage of either 220V (10A) or 110V (15A) with automatic leakage protection. -
Transportation
Ensure the machine is transported using shock-absorbing packaging provided by the manufacturer and empty the water tank before transportation. -
Installation Process
1. Install the handle holder, screen, and handles, add water, and connect the power cable following the provided instructions.
2. Allow the machine to stand still for 24 hours in a normal room temperature environment after transportation before installation.
- Operation Interface
After turning on the machine, follow the on-screen instructions to select the desired handle and proceed with the operation.
FAQ
-
Q: What should I do if the machine encounters leakage?
A: The machine is equipped with automatic leakage protection that will power off the system in case of leakage to ensure user safety. -
Q: How should I transport the machine?
A: The machine must be disassembled for transportation, with the main unit and handle packed separately using shock-absorbing packaging. Remember to empty the water tank before transport.
Warning
Dear user:
Thanks for using our company’s products, to fully make use of the products,
Our sincere suggestions are as below:
- Please contact us if there is any trouble during the operation.
- Please follow the instructions to fit and operate the machine correctly.
- It forbids others to open and remove the mainframe except the authorized people in the company.
- Please read the instructions in detail and keep it well for further reading and consulting.
- It forbids others to change and maintain the machine except professional people.
- Please do not remove or change any accessories of the machine.
Machine introduction
- touch screen
- handpiece
- key switch
- emergency stop button
- handle support frame
- filter cover
- fuse
- Leakage protection
- water inlet
- vent
- water outfall
- power connector
Operation environment
- Ambient temperature: 10~30℃;
- Relative humidity: ≤75%;
- Atmospheric pressure: 860~1060hpa;
Electrical safety
To ensure use safety, the instrument implements the national Standards GB9706.1-2007. The operating system’s rated voltage is 220V with a maximum input current is 10A or 110V with a maximum input current is 15A. This machine is equipped with automatic leakage protection, when leakage occurs, the machine will be automatically powered off to protect the system.
Transportation
This machine is a precision instrument, and the whole machine does not allow users to move and use it at a long distance. Because this machine is modular in design, the whole machine must be disassembled during transportation, and the main unit and handle must be packed and transported separately. The shock- absorbing packaging provided by the original manufacturer must be used during transportation. Please empty the water from the water tank before transportation.
Accessories list
- handle holder
- funnel
- laser glasses
- power cable
- goggle
- handle support
- exhaust pipe
- hex screwdriver
- screen
- filter
- fuse
- keys
- rubber rings
- screws
- handle
- handle
Installation process
After the machine is transported to the place of use, please take the machine out of the box first, and then install it after standing still for 24 hours in a normal room-temperature environment.
Step 1 Install the handle holder
Find the handle support, handle holder, screws, and screwdriver in the accessories bag and install them on the machine as the photo shows below
Step 2 Install the screen
Insert the female connector on the back of the screen into the male connector
on the top of the machine, and screw it to make it tight.
Step 3 Install the handles
Take out the handle, and align the connector of the handle plug to the machine connector, tighten the knob in the direction indicated by the arrow.
Step 4 Add water
- Unscrew the water inlet
- Unscrew the vent
- Connect the funnel to the water inlet
- Add distilled water or pure water
- Keep adding water until water comes out from the vent
- Screw the vent and water inlet
Step 5 Install power cable
- Plug in the power cable and fasten it as the picture shows
- Switch on the leakage protector
- Release the red emergency stop button, insert the key, and switch it to turn on the machine
Operation interface
The interface of the main screen
After turning on the machine, you will see the following operation interfaces.
Click the button of the welcome interface (Pic1) to enter the handle selection interface (pic2), Select the handle you need to use and click or enter the next interface.
- Water flow display: monitor the water flow speed of the machine to ensure the normal operation of the water circulation system.
- Water temperature display: real-time monitoring of the water temperature in the water tank to ensure that the machine works at normal water temperature.
- Single count: record the number of times of laser is emitted by a single treatment handle.
- Total count: Record the total number of lasers emitted by the handle.
- Handle refrigeration intensity adjustment.
- Save the current treatment parameters, the next treatment will automatically use the current treatment parameters.
- Restore factory setting parameters
After setting all treatment parameters, click to be ready for treatment.
Interface of handle
For the convenience of users, our machine is specially equipped with a touch
screen on the handle, the treatment parameters can be adjusted by the screen
on the handle.
Treatment steps
Step 1
Before treatment, ask the client whether he/she has been exposed to the sun within two weeks and whether he/she has done other types of hair removal projects.
Step 2 Remove hair from the treatment area
Step 3 Treatment Parameter Setting
Turn on the machine, and select the corresponding skin color and treatment area. After the parameters are set, click the work button ( ) to turn on the cooling system of the handle. (Notice: Turning on the cooling system of the handle in advance can make the handle surface temperature reach a low temperature before treatment to ensure the comfort of treatment.)
Step 4 Apply cold gel (ultrasound gel) to the treatment area
The thickness of the cold gel is about 1mm to ensure that the handle slides normally on the skin surface. Too much cold gel may affect the treatment result.
Step 5 Wear laser glasses and goggles
Step 6 Start treatment
- During the treatment process, the handle should be kept close to the skin at 90° at all times, and there should be no gaps to avoid burns to the skin. The handle should be kept sliding at a constant speed, and the sliding speed of the handle should be controlled according to the selected frequency (Hz).
- The therapist should keep asking about the feelings of the client and adjust the energy, pulse width, and frequency according to the actual feelings of the client. It is normal if the client feels warm, slight burning, or slight pain.
Step 8
Clean the treatment area after the treatment, and observe whether there is any
abnormal reaction on the skin of the client. Then cold compress the treatment
area.
Step 9
Wipe the probe to make it clean and put it back. Record the current use
parameters and turn off the machine.
Precautions after treatment
- Please do not take a hot bath on the day of treatment, you can wipe your body gently with warm water
- Do not soak in hot springs and have a sauna within one week after treatment
- Do not massage the treatment area vigorously within one week after treatment
- Maintain a daily drinking volume of more than 3 liters to accelerate metabolism and promote fat excretion
- No need to diet, maintain a normal diet, eat more vegetables and protein, and do not overeat
- Appropriate exercise can accelerate fat excretion, promote therapeutic effects, and is beneficial to health
Indications
Hair removal and skin rejuvenation
Contraindications
- People with heart disease or high blood pressure, or configured cardiac pacemaker.
- Patients with acute inflammation, Kidney disease, asthma, deep vein thrombosis, thrombus, and cancer.
- People with hemorrhagic disease, trauma, or who are bleeding.
- Pregnant women and children.
- Patient with skin inflammation or edema.
- People with an abnormal immune system.
- People who have recently taken photosensitivity drugs and those who are allergic to light.
- People who recently used hair removal cream, wax paper, and other hair removal methods, should do laser hair removal treatment after one month.
Maintenance & Troubleshooting
Maintenance
- After each treatment, please wipe the treatment handle with alcohol in time to clean up the cold gel and other stains remaining on the handle
- To ensure the service life of the machine, please change the water for the machine once a month. Please use distilled or purified water. Do not use mineral water or tap water to avoid damage to the machine.
- Please replace the filters every 3 month
- If the machine is left unused for a long time, please turn it on and run it twice a week, not less than ten minutes each time, and change the water once a month to ensure the normal operation of the machine.
Troubleshooting
- The machine cannot be turned on
- Please confirm again whether the keys of the machine and the emergency stop switch are both turned on
- Please check if the power line of the machine is properly connected
- Please check whether the leakage protector is in the ON state
- Please check whether the fuse of the machine is burned out, if it is, please find a spare fuse in the ingredient package and replace it
- Water flow is too low
- Please check if the water tank is full. If the water tank is not full, please fill it up. If the water tank is full of water, please open the water pump vent at the rear of the machine, turn the machine on, let the water flow out for 3 seconds, and then close the water pump vent
- The handle is not installed well or the handle is loose
- Please check if the handle is plugged in
- Handle recognition error
- Please contact our engineer to check whether the connection of the temperature control sensor is normal
- The water temperature is too high
- Please make sure that the temperature in the treatment room is below 25 degrees Celsius. If the temperature in the treatment room is too high, please wait for the room temperature to drop before using the machine. If you are in a hurry, you can add cold water to the water tank
- The water temperature is too low
- Please make sure that the temperature in the treatment room is higher than 16 degrees Celsius. If the temperature in the treatment room is too low, please wait for the room temperature to rise before using the machine. If you are in a hurry, add warm water to the water tank
- If your problem cannot be solved by the above methods or you still encounter other problems, please contact our after-sales engineers or sales personnel in time, please do not disassemble the machine by yourself.
Email for service: service@bjnubway.com.
Beijing Nubway S & T Co., Ltd.
- address: West Zone Building No.5 Maohua Industry Park, No.1 Caida 3rd Street Shunyi District Beijing 101300 China.
- e-mail: info@bjnubway.com
- phone: +86 1060418533
- website: www.nubway.com.
References
- Beijing Nubway S&T Co., Ltd. - Manufacturing Corporation of Laser Beauty Machine & Aesthetic Machine
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>