Shelly 2PM Pro Dimmer Instruction Manual
- September 3, 2024
- Shelly
Table of Contents
Shelly 2PM Pro Dimmer
Legend
Device terminals
- SW1 and SW2 Switch input terminals controlling O1
- SW3 and SW4 Switch input terminals controlling O2
- O1: Load circuit 1 output terminal
- O2: Load circuit 2 output terminal
- L: Live (110-240 V) terminals
- N: Neutral terminal
- LAN: Local Area Network RJ 45 connector
Wires
- L: Live (110-240 V) wire
- N: Neutral wire
Shelly Pro Dimmer 2PM
DIN-rail mountable, two-channel smart dimmer
Safety information
For safe and proper use, read this guide, and any other documents accompanying this product. Keep them for future reference. Failure to follow the installation procedures can lead to malfunction, danger to health and life, violation of law, and/or refusal of legal and commercial guarantees (if any). Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this device due to failure to follow the user and safety instructions in this guide.
- This sign indicates safety information
- This sign indicates important note.
- WARNING! Risk of electric shock. Installation of the Device to the power grid must be performed carefully by a qualified electrician.
- WARNING! Before making any changes to the connections, ensure there is no voltage present at the Device terminals.
- CAUTION! Plug in or unplug the LAN cable only when the Device is powered off. The parts of the LAN cable that may be touched when plugging in or unplugging it, must not be metallic.
- CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
- CAUTION! Connect the Device only to a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device can cause fire, property damage, and electric shock.
- CAUTION! The Device and the appliances connected to it, must be secured by a cable protection switch in accordance with EN60898-1 (tripping characteristic B or C, max. 10A rated current, min. 6 kA interrupting rating, energy limiting class 3).
- CAUTION! Before installing the Device, turn the circuit breakers off. Use a suitable test device to make sure there is no voltage on the wires you want to connect. When you are sure that there is no voltage, proceed to the installation.
- CAUTION! Do not use the Device if it shows any sign of damage or defect.
- CAUTION! The Device may be connected to and control only electric circuits and appliances that comply with the applicable standards and safety norms.
- CAUTION! Plug in or unplug the LAN cable only when the Device is powered off. The parts of the LAN cable that may be touched when plugging in or unplugging it, must not be metallic.
- CAUTION! The Device is intended only for indoor use.
- CAUTION! Keep the Device away from dirt and moisture.
Product Description
Shelly Pro Dimmer 2PM (the Device) is a DIN-rail mountable, two-channel smart
dimmer.
The Device can be accessed, controlled, and monitored remotely from any place
where the User has internet connectivity, as long as the device is connected
to a Wi-Fi router and the Internet.
The Device has an embedded web interface used to monitor, control, and adjust the Device. The web interface is accessible at http://192.168.33.1 when connected directly to the Device access point or at its IP address when you and the Device are connected to the same network.
The Device can access and interact with other smart devices or automation
systems if they are in the same network infrastructure.
Shelly Europe Ltd. provides APIs for the devices, their integration, and cloud
control. For more information, visit https://shelly-api-docs.shelly.cloud
The Device comes with factory-installed firmware. To keep it updated and secure, Shelly Europe Ltd. provides the latest firmware updates free of charge. Access the updates through either the embedded web interface or the Shelly Smart Control mobile application. Installation of firmware updates is the user’s responsibility.
Shelly Europe Ltd. shall not be liable for any lack of conformity of the Device caused by the failure of the user to install the available updates in a timely manner.
Installation instructions
- To connect the Device, we recommend using solid single-core wires or stranded wires with ferrules. The wires should have insulation with increased heat resistance, not less than PVC T105°C (221°F).
- When connecting wires to the Device terminals, consider the specified conductor cross section and stripped length. Do not connect multiple wires into a single terminal.
- For security reasons, after you successfully connect the Device to the local Wi-Fi network, we recommend that you disable or password-protect the Device AP (Access Point).
- To perform a factory reset of the Device, press and hold the Con-trol button for 10 seconds.
- To enable the access point and the Bluetooth connection of the Device, press and hold the Control button for 5 seconds.
Connect the first load to the O1 terminal of the Device and the Neutral wire
as shown in the wiring diagram.
Connect the second load to the O2 terminal of the Device and the Neutral wire
as shown in the wiring diagram.
Connect the Live wire to the L terminal.
If you want to control the dimming with a single button (per channel), connect
buttons to the SW1 and SW3 terminals and to the Live wire as shown in Fig. 1
b).
If you want to control the dimming with two buttons (per channel), connect
buttons to the SW1, SW2, SW3, and SW4 terminals, and to the Live wire as shown
in Fig. 1 a).
If you want to just turn the lights on or off, connect the switches to the SW1
and SW3 terminals and the Live wire as shown in Fig. 1 c).
Specifications
- Size (HxWxD): 94x19x69 mm / 3.70×0.75×2.71 in
- Weight: 75 g / 2.7 oz
- Screw terminals max torque: 0.4 Nm / 3.5 lbin
- Conductor cross section:
- 0.5 to 2.5 mm² / 20 to 14 AWG (green connectors)
- 0.5 to 1.5 mm² / 20 to 16 AWG (blue connector) (solid, stranded, and bootlace ferrules)
- Conductor stripped length:
- 6 to 7 mm / 0.24 to 0.28 in (green connectors)
- 5 to 6 mm / 0.20 to 0.24 in (blue connector)
- Mounting: DIN-rail
- Shell material: Plastic
- Shell color: Lime
- Ambient working temperature: -20°C to 40°C / -5°F to 105°F
- Humidity: 30% to 70% RH
- Max. altitude: 2000 m / 6562 ft
- Power supply: 110 – 240 VAC ~ 50/60 Hz
- Power consumption: < 2 W
- External protection: Max. 10 A, tripping characteristic B or C, 6 kA interrupting rating, energy limiting class 3
- Dimming type: Trailing edge
- Max. output power: 200 W per channel
- Voltmeter (AC): Yes
- Ammeter (AC): Yes
- Power and energy meters: Yes
- Internal-temperature sensor: Yes
- Supported loads:
- Incandescent
- Dimmable LED
- Dimmable electronic transformers
- Iron-core transformers with low-voltage incandescent lamps
Wi-Fi
- Protocol: 802.11 b/g/n
- RF band: 2400-2483 MHz
- Max. RF power: < 20 dBm
- Range: Up to 30 m / 100 ft indoors and up to 50 m / 160 ft outdoors (depending on local conditions)
Bluetooth
- Protocol: 4.2
- RF band: 2400-2483.5 MHz
- Max. RF power: < 4 dBm
- Range: Up to 30 m / 100 ft outdoors, up to 10 m / 33 ft indoors (depending on local conditions)
- CPU: ESP32-D0WDQ6
- Flash: 8MB
- Schedules: 20
- Webhooks (URL actions): 20 with 5 URLs per hook
- Scripting: Yes
- MQTT: Yes
Shelly Cloud inclusion
The Device can be monitored, controlled, and set up through our Shelly Cloud
home automation service. You can use the service through either our Android,
iOS, or Harmony OS mobile application or through any internet browser at
https://control.shelly.cloud/
If you choose to use the Device with the application and Shelly Cloud service,
you can find instructions on how to connect the Device to the Cloud and
control it from the Shelly app in the application guide: https://shelly.link
/app-guide
The Shelly mobile application and Shelly Cloud service are not conditions for
the Device to function properly. This Device can be used standalone or with
various other home automation platforms.
Troubleshooting
In case you encounter problems with the installation or operation of the Device, check its knowledge base page: https://shelly.link/pro_dimmer_2PM
Declaration of Conformity
Hereby, Shelly Europe Ltd. declares that the radio equipment type Shelly Pro
Dimmer 2 PM is in compliance with Directive 2014/53/EU, 2014/35/EU,
2014/30/EU, 2011/65/EU. The full text of the EU declaration of conformity is
available at the fol-lowing internet address:
https://shelly.link/pro_dimmer_2PM_DoC
Manufacturer : Shelly Europe Ltd.
Address : 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail : support@shelly.cloud
Official website : https://www.shelly.com
Changes in contact information are published by the Manufac-turer on the
official website.
All rights to the trademark Shelly® and other intellectual rights associated
with this Device belong to Shelly Europe Ltd.
References
- Shelly Control
- Welcome to Shelly Technical Documentation | Shelly Technical Documentation
- Shelly Smart Control Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>