B METERS ISMA-B-8U-IP MINI I/O Modules Installation Guide

September 3, 2024
B METERS

ISMA-B-8U-IP MINI I/O Modules

“`html

Product Specifications:

  • Ingress Protection Rating: IP40 – for indoor
    installation

  • Universal Inputs: Voltage measurement, Current
    measurement, Temperature measurement, Dry contact

  • Power Supply: Follow specifications for power
    supply considerations

  • Interface: Address, Baudrate

  • Temperature: Operating temperature

  • Relative Humidity: Operating humidity

  • Connectors: Detailed connectors
    information

  • Dimension: Product dimensions

  • Mounting: Mounting instructions

  • Housing Material: Material used for
    housing

Product Usage Instructions:

Installation Guidelines:

Please read the instruction before use or operating the device.
In case of any questions after reading this document, please
contact the iSMA CONTROLLI Support Team
(support@ismacontrolli.com).

Electrical installation of this product must be done in
accordance with national wiring codes and conform to local
regulations.

Power Supply Considerations:

Follow the EN 60730-1 specifications for power supply
considerations. Ensure correct wiring before turning the power on
to prevent hazards.

Wiring Instructions:

Ensure wiring is done as close to the coil as possible to
prevent interference and hazards.

Frequently Asked Questions (FAQ):

Q: What should I do if the device causes interference?

A: If the device causes interference, try to correct it by
ensuring proper wiring and following the installation guidelines.
Contact support for further assistance.

Q: How should I handle power supply connections?

A: Make sure the product has been correctly wired before turning
the power on to avoid electric shock. Follow the specified power
supply considerations for safe operation.

“`

ISMA-B-8U-IP Installation Instructions

Follow us on:

/bmetersuk

B METERS UK | www.bmetersuk.com | iSMA

iSMA-B-8U-IP

Power supply Universal inputs
Interface
Address Baudrate Ingress protection rating
Temperature
Relative humidity Connectors Dimension Mounting Housing material

SPECIFICATION
DC: 24 V ± 20%, 1.5 W; AC: 24 V ± 20%, 2.3 VA 8x voltage, current and resistance measurement, dry contact RS485 half-duplex: Modbus RTU/ASCII, up to 128 devices on the bus Ethernet: Modbus TCP/IP or BACnet/IP Set by switch in range from 0 to 99 Set by switch in range from 4800 to 115200 bps
IP40 – for indoor installation
Operating: -10°C to +50°C (14°F to 122°F) Storage: -40°C to +85°C (-40°F to 185°F) 5 to 95% RH (without condensation) Separable, max 2.5 mm2 (18 ­ 12 AWG) 37x110x62 mm (1.45×4.33×2.44 in) DIN rail mounting (DIN EN 50022 norm) Plastic, self-extinguishing PC/ABS

TOP PANEL

Voltage measurement

UNIVERSAL INPUTS

Current measurement

Temperature measurement

Dry contact

COMMUNICATION

POWER SUPPLY

Follow us on:

/bmetersuk

B METERS UK | www.bmetersuk.com | iSMA

WARNING

TERMINALS OF THE DEVICE

· Note, an incorrect wiring of this product can damage it and lead

to other hazards. Make sure the product has been correctly wired

before turning the power ON.

· Before wiring, or removing/mounting the product, be sure to turn

the power OFF. Failure to do so might cause electric shock.

· Do not touch electrically charged parts such as the power

terminals. Doing so might cause electric shock.

· Do not disassemble the product. Doing so might cause electric shock or faulty operation.

· Use the product within the operating ranges recommended in the

specification (temperature, humidity, voltage, shock, mounting

direction, atmosphere etc.). Failure to do so might cause fire or

faulty operation.

· Firmly tighten the wires to the terminal. Insufficient tightening of

the wires to the terminal might cause fire.

EN 60730-1 POWER SUPPLY CONSIDERATIONS

· Electrical safety in the building automation and control systems is essentially based on the use of extra low voltage which is strictly separated

from the mains voltage. This low voltage is either SELV or PELV according to EN 60730-1.

· Protection against electric shock is ensured by the following measures:

o limitation of voltage (low voltage AC/DC 24V supply, either SELV or PELV) o protective-separation of the SELV-system from all circuits other than SELV and PELV

o simple-separation of the SELV-system from other SELV-systems, from PELV- systems and earth

· Field devices such as sensors, status contacts and actuators connected to the low-voltage inputs and outputs of I/O modules must comply with

the requirements for SELV or PELV. The interfaces of field devices and other systems must also satisfy SELV or PELV requirements.

· When the supply of SELV or PELV circuits is obtained from supply mains of higher voltages it shall be provided by safety transformer or a

converter designed for continuous operation to supply SELV or PELV circuits.

FCC COMPLIANCE NOTE

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and

can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct

the interference by one or more of the following measures:

· Reorient or relocate the receiving antenna.

· Increase the separation between the equipment and receiver.

· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

· Consult the dealer or an experienced radio/TV technician for help.

WIRING

· Line power cables must be routed with spatial separation from signal and data transmission cables.

· Analogue and digital signal cables should also be separated.

· It is recommended to use shielded cables for analogue signals, cable shields should not be interrupted by intermediate terminals.

· The shielding should be earthed directly after the cable enters the cabinet.

· It is recommended to install interference suppressors when switching inductive loads (e.g. coils of contactors, relays, solenoid valves). RC snubbers or varistors are suitable for AC voltage and freewheeling diodes for DC voltage loads. The suppressing elements must be connected as

close to the coil as possible

Follow us on:

/bmetersuk

B METERS UK | www.bmetersuk.com | iSMA

INSTALLATION GUIDELINE
Please read the instruction before use or operating the device. In case of any questions after reading this document, please contact the iSMA CONTROLLI Support Team (support@ismacontrolli.com).
· Before wiring or removing/mounting the product, make sure to turn the power off. Failure to do so might cause an electric shock. · Improper wiring of the product can damage it and lead to other hazards. Make sure that the product has been correctly wired before turning the power on. · Do not touch electrically charged parts such as power terminals. Doing so might cause an electric shock. · Do not disassemble the product. Doing so might cause an electric shock or faulty operation. · Use the product only within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere, etc.). Failure to do so might cause a fire or faulty operation. · Firmly tighten the wires to the terminal. Failure to do so might cause a fire. · Avoid installing the product in close proximity to high-power electrical devices and cables, inductive loads, and switching devices. Proximity of such objects may cause an uncontrolled interference, resulting in an instable operation of the product. · Proper arrangement of the power and signal cabling affects the operation of the entire control system. Avoid laying the power and signal wiring in parallel cable trays. It can cause interferences in monitored and control signals. · It is recommended to power controllers/modules with AC/DC power suppliers. They provide better and more stable insulation for devices compared to AC/AC transformer systems, which transmit disturbances and transient phenomena like surges and bursts to devices. They also isolate products from inductive phenomena from other transformers and loads. · Power supply systems for the product should be protected by external devices limiting overvoltage and effects of lightning discharges. · Avoid powering the product and its controlled/monitored devices, especially high power and inductive loads, from a single power source. Powering devices from a single power source causes a risk of introducing disturbances from the loads to the control devices. · If an AC/AC transformer is used to supply control devices, it is strongly recommended to use a maximum 100 VA Class 2 transformer to avoid unwanted inductive effects, which are dangerous for devices. · Long monitoring and control lines may cause loops in connection with the shared power supply, causing disturbances in the operation of devices, including external communication. It is recommended to use galvanic separators. · To protect signal and communication lines against external electromagnetic interferences, use properly grounded shielded cables and ferrite beads. · Switching the digital output relays of large (exceeding specification) inductive loads can cause interference pulses to the electronics installed inside the product. Therefore, it is recommended to use external relays/contactors, etc. to switch such loads. The use of controllers with triac outputs also limits similar overvoltage phenomena. · Many cases of disturbances and overvoltage in control systems are generated by switched, inductive loads supplied by alternating mains voltage (AC 120/230 V). If they do not have appropriate built-in noise reduction circuits, it is recommended to use external circuits such as snubbers, varistors, or protection diodes to limit these effects.
Electrical installation of this product must be done in accordance with national wiring codes and conform to local regulations.