CURRENTBODY MZ-07M Plus L Skin LED Hair Regrowth User Manual

September 2, 2024
CurrentBody

CURRENTBODY MZ-07M Plus L Skin LED Hair Regrowth User Manual

Includes important safety information.
Read all instructions prior to use.

PLEASE KEEP THESE INSTRUCTIONS SAFE

Welcome to CurrentBody Skin™ LED Hair Regrowth

Established in 2009, Current Body is the world’s only online retailer dedicated to home-use beauty devices. As the first company to recognise devices as one of the fastest growing trends in the world of beauty, we have unrivalled expertise in selecting at-home devices that are science-backed and clinically proven. We offer our customers the ultimate choice of devices that treat a wide range of concerns, including anti -ageing, cleansing and hair removal.

Underpinning our range of innovative beauty technology is expert education to help our customers choose the right device for them and excellent customer service.

Our highly trained beauty device experts are on hand to offer impartial advice and answer your questions in person, as well as how-to videos and top tips available throughout our website and social media channels.

WHAT IS IN THE BOX

  1. Current Body Skin™ LED Hair Regrowth device
  2. User Manual
  3. USB charging cord
  4. Device base

ADVERSE REACTION

If you have any adverse reaction, such as discomfort, skin discoloration, skin irritation or other concerns from using this device, stop using it immediately and consult your Healthcare Provider.

Skin irritation, bruising, contact burns, dizziness, nausea and headaches are rare but possible side effects. Immediately stop using the device and contact your Healthcare Provider.

IMPORTANT SAFETY INFORMATION

  • Do not operate the device where it could come in contact with water.
  • Do not use or charge the device with a power adapter that is damaged or faulty. Do not harshly bend or abuse the USB charging cord.
  • Do not attempt to take the device apart. The device is not serviceable by the user. This will void the warranty.
  • Stop using the device immediately if you think it is defective.

CUSTOMER CARE

Please email sales@currentbody.com if you have any questions or you need any advice.

WARNINGS

  • This device is designed for use on adults over 18 years of age and not recommended for use on infants or children.
  • Please consult your doctor prior to use if you are or suspect you are pregnant or breastfeeding.
  • Please consult your doctor prior to use if you have or suspect you have cancer.
  • Do not use on wet hair.
  • Do not use the device if it is wet. If the device has fallen into water, you must unplug it first before you touch it.
  • Do not look directly into the lights as this may cause temporary discomfort.
  • Do not use if your skin is red or swollen from a previous treatment.
  • Do not use the device to treat skin that is painful to touch, raised (higher than surrounding skin), crusting, or bleeding.This may be a sign of a more serious condition and should be checked by your doctor.
  • No modification of this equipment is allowed.
  • This device contains a Lithium lon Battery. Before disposal of this device, please review your local laws and requirements surrounding Lithium lon Battery disposal. The preferred method of disposal is through recycling.
  • Use the device only on dry and clean hair. Use in combination with serums, any gel or other hair supplement could damage the product and will void warranty.
  • STOP using the device and consult your Healthcare Provider if you experience an adverse reaction from using the device.
  • STOP using the device if you experience symptoms of hypotension (dizziness or light-headedness) while using the device.
  • STOP your treatment if it feels hot or your skin feels uncomfortably warm.
  • DO NOT let children play with the device. Cleaning and charging the device must not be done by children.
  • DO NOT use the device to treat rosacea, moles, warts, open sores, cancerous lesions or any skin condition.
  • DO NOT use the device on spots without pigmentation or areas on the skin that have vitiligo.
  • DO NOT use the device if you have any open wounds.
  • DO NOT use the device outdoors to prevent damage to the product.
  • DO NOT drop or insert any object into any openings of the device.
  • DO NOT use or store the device near hot surfaces or in direct sunlight.
  • DO NOT use the device with non-manufacturer-approved accessories.
  • DO NOT use solvents or abrasive cleaners on the device.
  • DO NOT use the device in any other way then specified in this manual.
  • DO NOT use the device if you have had a recent surgery or other surgical procedures.
  • DO NOT use the device over a bacterial infection as this may result in the worsening of symptoms.
  • Close supervision is necessary when this device is used, cleaned or stored near children or those with reduced physical or mental abilities.
  • DO NOT use the device with any other USB-C cable than provided by CURRENTBODY.
  • DO NOT scratch the light emitting surface.
  • DO NOT use the Device to treat any other conditions apart from the conditions that are indicated in that are indicated in the chapter “Potential benefits”.
  • DO NOT use the device over areas with phlebitis, thrombophlebitis, and varicose veins.
  • DO NOT use the device if you have a medical history of seizures or epilepsy that was triggered by light.

Note: The device should only be supplied with 5V DC low voltage. If any part of the main adapter or cable is damaged, discontinue use. Contact CURRENTBODY customer support for help and advice.

CAUTIONS

  • Discontinue use if the device overheats or becomes uncomfortably hot.
  • Always unplug the device from the outlet after charging is complete.
  • Do not store the device in a location with temperatures over 100 Fahrenheit as this may cause damage to the plastic coating.
  • Do not attempt to open or repair the device or power supply.
  • Do not drop the device on hard surfaces, as this could damage it. Using a damaged device could result in injury.
  • If you have any concerns about the skin you are treating, you should cease use and check with your doctor.
  • Contact your doctor if you have any medical questions regarding use of this device.

CONTRAINDICATIONS

Ask your doctor prior to using if you:

  1. Are taking prescription or over-the-counter drugs known to cause light sensitivity. You can find more information and a list of  drugs that can cause light sensitivity at: https://www.currentbody.com/pages/led-contraindications
  2. Have any suspicious or cancerous lesions.
  3. Have any photosensitive disorders or any genetic conditions of the eye.

RISKS AND BENEFITS

Potential risks
Immediately after treatment skin may appear red. Skin should return to normal within 1-2 hours.
Temporary headaches may immediately follow the light treatment. Headaches can be treated with an appropriate pain killer and rehydration.

Potential benefits

CurrentBody Skin LED Hair Regrowth is indicated to treat androgenetic alopecia and promote hair growth in males who have Norwood-Hamilton Classifications of IIa to V patterns of hair loss; and to treat androgenetic alopecia and promote hair growth in females who have Ludwig-Savin Scale I-1 to I-4, II-1,
II-2, or frontal patterns of hair loss, both with Fitzpatrick Skin Types I – IV.

Test yourself for light sensitivity prior to using on your head:

  1. Power on your device.
  2. Place the device on your elbow for 3 minutes.
  3. After 3 minutes, visually check the area. If the area has turned red and this lasts for more than one hour, your skin has a sensitivity to light. Return the device to CurrentBody within 14 days for a full refund.

DEVICE OVERVIEW

CURRENTBODY Skin™ LED Hair Regrowth is a Light Emitting Diode (LED) device that harnesses energy to help stimulate hair regrowth. The device incorporates natural light energy in the 660 nm wavelength to help thicken hair and stimulate new growth.

How it works
Your hair can lose its lustre for many reasons.
Healthy follicles can become damaged and weaken over time resulting in thinning, weak hair.

The light in this device can penetrate deep within the layers of your skin to increase circulation and stimulate the body to grow hair faster, helping to give not only thicker, more lustrous hair but a healthier scalp too.

CURRENTBODY Skin™ LED Hair Regrowth is programmed to automatically switch off after the recommended 10 minutes treatment so it is very easy to use. With daily treatments you can achieve professional results in the comfort of your own home.

HOW TO USE

Set up:

  1. Unpack your CURRENTBODY Skin™ LED Hair Regrowth.
  2. Plug USB charging cord into the USB port connector on the device.
  3. Plug USB charging cord into a Universal USB Power Adapter (not included) and then into a mains outlet.
  4. The power indicator light will flash while charging.
  5. Charge your device for 2.5-3 hours. The device is fully charged when the power indicator light is solid (not flashing).
  6. Ensure you unplug the device from the USB charger before using. For your safety, this device will not work when it is charging.

To connect the speakers to your phone via bluetooth:

  1. Switch on the LED Hair Regrowth device.
  2. Switch bluetooth ON on your phone.
  3. The LED Hair Regrowth device will be discoverable as CurrentBody.com.

Before your first use:

  1. Take a photo of the area you wish to treat, ensuring that you can clearly see your hair and scalp.
  2. We recommend you take a photo every 4 weeks to see the difference the device is making to your hair.

Instructions for Use:

  1. You must conduct a sensitivity test before use.
  2. Ensure your hair and scalp are clean and dry prior to use.
  3. Place the device on your head and adjust the head fit by pushing the headphones upwards or downwards.
  4. Switch on the device by pressing the ON button underneath the digital display.
  5. There is a timer on the side of the device so you can see how long you have left of your 10 minutes treatment.
  6. The device features an automatic shut-off function after completion of a 10 minutes treatment.
  7. Remove device from your head and wipe clean (see cleaning instructions).
  8. Place the device on the protective base when not in use.
  9. When the charge is low the indicator light will flash. To recharge the device, follow the instructions above.
  10. Once recharged, do not leave it plugged in. Leaving the device on charge when not needed can shorten the life of the battery.

For best results:

  1. Use daily for a minimum of 16 weeks.
  2. Use the device on clean, dry scalp.
  3. Do not use more than 10 minutes a day.

Maintenance:

  1. This device has no serviceable parts. The battery is not accessible and not serviceable. Users should not attempt to access or service the battery as this will damage the device and void the warranty.
  2. Device includes only an ON/OFF button. All settings are set to the factory setting.
  3. Charge the device only with the supplied USB power charging cord and adapter (not included). Compatible with power supply: 100V / 240V.

Cleaning:

  1. Turn device off and unplug from any power source.
  2. Wipe the tops of the LEDs with alcohol wipes or damp cloth to remove any residue after each use.
  3. Clean the device body by using damp or microfibre cloth. Do not use chemical or alcohol based cleaners on the exterior as harsh chemicals may discolour the discolour the device.
  4. Allow the device to dry completely prior to use.

Storage:
The lifetime of the Lithium battery can be maximized by allowing it to fully charge and then fully discharge during regular use.
Store the device at room temperature in dry conditions.
Store the device on the base or in the packaging. Make sure the device will not bend, stretch or crush while being stored or when travelled with.
Avoid storing the device in dusty storing the device in damp, dusty or humid conditions.

Troubleshooting:

System is not turning on:
a. Is the device fully charged? (power indicator light is on and solid)
b. Is the power indicator light illuminated?
System is not charging:
a. Is USB power cord firmly inserted into the device?(does power indicator light turn on?)
b. Try a different wall outlet to determine if there is power to the outlet.
System shuts off abruptly, prior to completion of 10 minutes treatment:
a. System is designed to shut off automatically after 10 minutes.
b. System may shut off after multiple repeated uses if the device exceeds desired temperature. Allow the device to cool for several minutes and try again.

WARRANTY

Under normal use this product is guaranteed for 2 years after its original purchase date against manufacturing defects in materials or workmanship. This warranty extends only to the original purchaser. If the product should become faulty within the warranty period, contact CurrentBody.

  • CURRENTBODY reserves the right to repair a defective product.
  • CURRENTBODY reserves the right to replace a defective product with the most compatible product currently available.
  • This warranty does not cover damage caused by the following:
    • Accident, misuse, abuse or alteration
    • Servicing by unauthorised persons
    • Connection to incorrect power sources
    • Use with unauthorised accessories

CurrentBody shall not be responsible for any incidental, special or consequential damages resulting from the use of this product.
All implied warranties, including but not limited to implied warranties of fitness and merchantability are limited in duration to two years from date of original purchase. This warranty gives you specific legal rights, and you may also have other rights that vary from country to country. Some countries do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so some of the above limitations and exclusions may not apply to you. This warranty is given in lieu of all other warranties, written or oral, whether expressed by affirmation, promise, description, drawing, model or sample. Any and all warranties other than this one, whether expressed or implied, including implied warranties of merchantability and fitness for a particular purpose are hereby disclaimed. If the product is defective within the warranty period please contact CurrentBody.

PRODUCT STANDARDS THAT APPLY

The Device has been tested to or complies with the following standards:
IEC/EN 60601-1:2006/A12:2014. Medical electrical equipment.
General requirements for basic safety and essential performance.
IEC/EN 60601-1-2:2015 Medical electrical equipment. General requirements for basic safety and essential performance.
Collateral standard. Electromagnetic compatibility. Requirements and tests.
IEC/EN 60601-1-6:2010 AMD12013 Medical Electrical
Equipment – Part 1General Requirements for Basic Safety and Essential Performance –Collateral Standard: Usability.
etc …

SPECIFICATION

Specification

Produce name| LED Hair Regrowth
Model| MZ-07
**** Power source| Adapter:Input: 100-240V~50/60Hz, 0.25AOutput: 5.0V 1.0A
Weight| 1600g±10g
Dimensions| 205 x249 x220 (W x L x H)
Wavelengths| Red 660nm
Energy Source| LEDs
Power Density| LED Irradiance: 30mw/cm2 Average Irradiance: < 5mw/cm2
Treatment time| 10 minutes everyday
Location for Use| Head
Environment of Use| OTC
Safety and EMC| IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6, IE C60601-1-11, IEC 60601-2-57
Biocompatibility| ISO 10993-1, ISO 10993-5, ISO 10993-10
Operating Environment| Temperature: 14~95℉ Humidity: 30-80%RH
Storage Environment| Temperature: -4~140℉ Humidity: 30-90%RH

THE SYMBOLS AND DESCRIPTION

No. Symbols Description
**** 1 **** **** Manufacturer.
**** 2 **** “WEEE (Waste Electrical and Electronic Equipment)”. This means

that the battery should not be disposed of in the household waste.
**3| **| Consult instructions for use.
**4| **| The date of manufacture.
**5| IP 22| Protection against ingress of solids, it means the volume of the solids should less than 12 mm.
Protection against ingress of water, it means the device could protected against vertical falling water drop 15°.
****
6| **| Type BF Applied Part.
7| |
**8| **|
**9| **| Batch code.
**10| **| Symbol for “SERIAL NUMBER”. This symbol shall be accompanied by the manufacturer’s serial number.
**11| **| Temperature limit.
**12| **| Humidity limit.
**13| **| This symbol means keep dry.
**14| **| This symbol means keep the device away from direct sunlight.

SAFETY AND EMC

  1. It complies with Medical Electrical Safety Standards (IEC 60601-1, IEC 60601-1-11, IEC 60601-2-57).
  2. This device also complies with Medical EMC Standard (IEC 60601-1-2).

Guidance and manufacturer’s declaration – electromagnetic emissions

LED Hair Regrowth is intended for use in the electromagnetic environment specified below. The customer or the user of LED Hair Regrowth should ansure that it is used in such an environment.
Emissions| Compliance| Electromagnetic environment– guidance
RF emissions CISPR 11| Group 1| LED Hair Regrowth uses LED energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11| Class B| LED Hair Regrowth is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies

Guidance and manufacturer’s declaration electromagnetic immunity


LED Hair Regrowth is intended for use in the electromagnetic environment specified below. The customer or the user of LED Hair Regrowth should ansure that it is used in such an environment.
Immunity test| IEC 60601 test level| Compliance level| Electromagnetic environment –guidance
Electrostatic discharge (ESD) IEC 61000-4-2| ±8 kV contact ±2KV, ±4KV,

±8KV, ±15KV air

| ±8 kV contact ±2KV, ±4KV,

±8KV, ±15KV air

| Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
Electrical fast transient/burst IEC 61000-4-4| ±2 kV 100 kHz repetition frequency| ±2 kV 100 kHz repetition

frequency

| Mains power quality should be that of a HOME HEALTHCARE ENVIRONMENT
Surge

IEC 61000-4-5

| ± 0,5 kV, ± 1 kV Line-to-line| ± 0,5 kV, ± 1 kV Line-to-line| Mains power quality should be that of a HOME HEALTHCARE ENVIRONMENT
Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11| 0% UT; 0,5 cycle (At 0″, 45°, 90°, 135″, 180°, 225″, 270° and 315)

0% UT; 1 cycle and 70% UT; 25/30 cycles (Single phase: at 0°)

0% UT; 250/ 300 cycle

| 0% UT; 0,5 cycle (At 0°, 45″, 90°, 135″, 180, 225″, 270° and 315°)

0% UT; 1 cycle and 70% UT; 25/30 cycles (Single phase: at 0″)

0% UT; 250/300 cycle

| Mains power quality should be a HOME HEALTHCARE ENVIRONMENT. If the user of LED Hair Regrowth requires continued operation during power mains interruptions, it is recommended that LED Hair Regrowth be powered from an uninterruptible power supply or a battery.
Power frequency (50/60 Hz) magnetic field IEC 61000-4-8| 30 A/m| 30 A/m| Power frequency magnetic fields should be at levels characteristic of a HOME HEALTHCARE ENVIRONMENT
NOTE : UT is the a.c. mains voltage prior to application of the test level
Guidance and manufacturer’s declaration – electromagnetic immunity

LED Hair Regrowth is intended for use in the electromagnetic environment specified below. The customer or the user of LED Hair Regrowth should ensure that it is used in such an environment.
Conducted RF IEC61000-4-6| 3 Vrms
0,15 MHz and
80 MHz
6 Vrms in ISM and amateur radio bands between 0,15 MHz and 80 MHz| 3 Vrms
0,15 MHz and 80 MHz6 Vrms in ISM and amateur radio bands between 0,15 MHz and 80 MHz| Portable and mobile RF communica- tions equipment should be used no closer to any part of LED Hair Regrowth, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance

d=1,2 P
d=1,2 P 80 MHz to 800 MHz
d=1,2 P
800 MHz to 2.7 GHz

Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation Distance in meters (m).

Radiated RF IEC 61000-4-3| 10V/m 80 MHz to 2.7GHz 80% AM at 1 kHz| 10V/m 80 MHz to 2.7GHz 80% AM at 1 kHz| Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of Equipment marked with the following symbol

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which LED Hair Regrowth is used exceeds the applicable RF compliance level above, LED Hair Regrowth should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating LED Hair Regrowth.b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m
Rocommended separation distances betwoen portable and mobile RF communications equipment and the LED Hair Regrowth

LED Hair Regrowth s Intended fo us n an electromagnetc anironment n which radiated FF- d@sturbancesare ontrol RGB The customer o the user of LED Hair Regrowthcan help prevent electromaqneticnteference by maintaining a minmu cistance betveen portable and mobie communications equipment (zansittes) and LED Halt Regronth as recommended below, according o the maximum output power o the communications equipment.
Rated maximum output power of transmitter (W)| Separation distance according to frequency of transmitter (m)
150 kHz to 80 MHz d = 1,2, P| 80 MHz to 800 MHz d = 1,2, P| 800 MHz to 2.7 GHz
d = 2,3, P
0.01| 0.12| 0.12| 0.23
0.1| 0.38| 0.38| 0.73
1| 1.2| 1.2| 2.3
10| 3.8| 3.8| 7.3
100| 12| 12| 23

MANUFACTURER INFORMATION

CurrentBody.comLtd
Q17, Crossley Road, Stockport, Greater Manchester, SK45B8
Currentbody BV, Naritaweg 2, 1437EL Rozenburg, Netherlands

CURRENTBODY skin LED Hair Regrowth is manufactured for CurrentBody.com Ltd. Q17, Crossley Road, Stockport, Greater Manchester, SK4 588, United Kingdom. CurrentBody BV, Naritaweg 2, 1437EL Rozenburg, Netherlands
currentbody.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals