276-8463 RS PRO 4G IOT Router User Manual
- September 7, 2024
- RS PRO
Table of Contents
- 276-8463 RS PRO 4G IOT Router
- 276-8463
- Regulatory and Type Approval Information
- Radio Specifications
- FCC& IC Radiation Exposure Statement
- Simplified EU & UK Declaration of Conformity
- Safety Information
- Document History
- Overview
- Package Checklist
- Panel Layout(May vary on difference models)
- Interface Descriptions
- 3. Reset Button
- Hardware Installation
- Login to the Device
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
276-8463 RS PRO 4G IOT Router
RS PRO 276-8463 Hardware Manual
276-8463
Hardware Manual
Version: 1.0.2
Date: July 14, 2023
RS PRO 276-8463 Hardware Manual
Regulatory and Type Approval Information
Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits
Name of the Part
|
Hazardous Substances
---|---
(Pb)
|
(Hg)
|
(Cd)
|
(Cr(VI))
|
(PBB)
|
(PBDE)
|
(DEHP)
|
(BBP)
|
(DBP)
|
(DIBP)
Metal parts
|
o
|
o
|
o
|
o
|
–
|
–
|
–
|
–
|
–
|
–
Circuit modules
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
Cables and cable assemblie s
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
Plastic and polymeric parts
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
o: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in RoHS2.0.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in RoHS2.0.
-: Indicates that it does not contain the toxic or hazardous substance.
Radio Specifications
RF technologies
|
2G, 3G, 4G, Wi-Fi
---|---
Cellular Frequency*
|
2G: GSM: B3/B8
3G: WCDMA: B1/B8
4G: LTE FDD: B1/B3/B7/B8/B20/B28A
Max RF power
|
33 dBm±2dB@2G, 24 dBm+1/-3dB@WCDMA, 23 dBm±2 dBm@LTE, 18 dBm@Wi-Fi
- May vary on difference models.
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
RS PRO 276-8463 Hardware Manual
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
FCC& IC Radiation Exposure Statement
This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Simplified EU & UK Declaration of Conformity
This radio equipment complies with EU Radio Equipment Directive (RED) 2014/53/EU, Low Voltage Directive (LVD) 2014/35/EU, EMC Directive 2014/30/EU, UK Radio Equipment Regulations 2017, EMC Regulations 2016, Electrical Equipment (Safety) Regulations 2016.
RS PRO 276-8463 Hardware Manual
Safety Information
General
– The router generates radio frequency (RF) power. When using the router, care must be taken on safety issues related to RF interference as well as regulations of RF equipment.
– Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is prohibited.
– Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the router should be away from computers, office equipment, home appliance, etc.
– An external antenna must be connected to the router for proper operation. Only uses approved antenna with the router. Please contact authorized distributor on finding an approved antenna. RF Exposure
– This device meets the official requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies.
– The device must be used with a minimum separation of 20 cm from a person’s body to ensure compliance with RF exposure guidelines. Failure to observe these instructions could result in your RF exposure exceeding the applicable limits.
Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open. Router may be used at this time.
The symbol indicates that the product should not be mixed with general household waste but must be sent to separate collection facilities for recovery and recycling.
The symbol indicates that the product meets the requirements of the applicable EU directives.
The symbol indicates that the product meets the requirements of the relevant UK legislation.
RS PRO 276-8463 Hardware Manual
Document History
Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.
Date
|
Firmware Version
|
Document
Version
|
Change Description
---|---|---|---
July 6, 2022
|
5.0.0
|
1.0.0
|
Initial release.
Nov. 23, 2022
|
5.0.0
|
1.0.1
|
Added declaration for product.
July 14, 2023
|
5.0.0
|
1.0.2
|
Modified declaration for product.
|
|
|
|
|
|
RS PRO 276-8463 Hardware Manual
Overview
Router is a Dual Ethernet port (LAN + WAN) 3G/4G router with advanced software functions at a very competitive price point.
Package Checklist
Before commencing installation ensure your package has the following components:
Note: The accessories could be different on specific order.
Panel Layout(May vary on difference models)
Interface Descriptions
1. Power Supply. 2PIN 3.5mm pitch terminal block.
DI &DO Internal Diagram
2. LED Indicator
Name | Color | Status | Description |
---|
RUN
|
Green
| On, solid|
Router is powered on (System is initializing)
On, blinking|
Router starts operating
Off|
Router is powered off
MDM
|
Green
| On, solid|
Link connection is working
On, blinking|
Data is sent and received.
Off|
Link connection is not working
USR
|
USR-OpenVPN
|
Green
| On, solid|
OpenVPN connection is established
Off|
OpenVPN connection is not established
USR-IPsec
|
Green
| On, solid|
IPsec connection is established
Off|
IPsec connection is not established
RS PRO 276-8463 Hardware Manual
RSSI
|
Green
|
On, solid
---|---|---
On, slow blinking (1s)
On, fast blinking
Off
WLAN
|
Green
|
On, solid
Green
|
Off
Signal Level: Best Signal Level
Wireless module: 21-31dB (signal strength) Signal Level: Average Signal Level
Wireless module: 11-20dB (signal moderate) Signal Level: Abnormal Signal Level Wireless module: 21-31dB (signal weak) No signal
WLAN is enabled and working properly WLAN is disabled or not working properly
Note: You can choose the display type of USR LED. For more details, please refer to
RT123_SM_RobustOS Software Manual, Services > Advanced > System >System Settings > User LED Type.
3. Reset Button
Function
|
Operation
---|---
Reboot
|
Press and hold the RST button for 2~ 5 seconds under the operating status.
Restore to default
configuration
|
Press and hold the RST button for 5~10 seconds, the RUN LED starts blinking quickly, the router will restore to default configuration.
Restore to factory
default settings
|
Once the operation of restoring default configuration is performed twice within one minute, the router will restore to factory default settings.
Note: The more details please refer to RT123_SM_RobustOS Software Manual, 2.3 Factory Reset.
4. Ethernet Ports. There are two Ethernet ports on R1510, including ETH0 (WAN/LAN), and ETH1. Each has two LED indicators. The green one is a link indicator but the yellow one doesn’t mean anything. For details about status, see the table below.
Ethernet LED Indicator
|
Status
|
Description
---|---|---
Link indicator
(Green)
|
On, solid
|
Connection is established
On, blinking
|
Data is being transferred
Off
|
Connection is not established
Hardware Installation
1. SIM Card Installation. Insert the SIM cards into the device, then stick the sticker.
2. Antenna Installation. Rotate the antenna into the antenna connector accordingly.
3. Terminal Block Installation. Insert the 2PIN, 3PIN terminal blocks into the interfaces connector.
4. Mounting Kit installation.
-Wall mounting
RS PRO 276-8463 Hardware Manual
-DIN rail mounting
5. Connect the Router to a Computer
6. Power Supply installation. There are two cables associated with the power adapter. Following to the color of the head, connect the cable marked red to the positive pole through a terminal block, and connect the yellow one to the negative in the same way.
Note: The range of power voltage is 9 to 36V DC.
RS PRO 276-8463 Hardware Manual
Login to the Device
1. Connect the router’s Ethernet port to a PC with a standard Ethernet cable.
2. Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure “Use the following IP address”.
3. To enter the gateway’s web interface, type http://192.168.0.1 into the URL field of your Internet browser.
4. Use login information shown in the product label when prompted for authentication.
5. After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device.
6. The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting.
7. The more configuration details please refer to RT123_SM_RobustOS Software Manual.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>